Emma J. Birks
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Emma J. Birks has a total of 195 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Kolodziej
University of Kentucky, Lexington, KY
4 shared publications - Stavros George Drakos
Department of Internal Medicine, Division of Cardiovascular Medicine (O.W.-P., E.D., I.K., T.C.H., E.T., J.S., S.G.D.), University of Utah Health & School of Medicine, Salt Lake City
4 shared publications - Josef Stehlik
Department of Internal Medicine, Division of Cardiovascular Medicine (O.W.-P., E.D., I.K., T.C.H., E.T., J.S., S.G.D.), University of Utah Health & School of Medicine, Salt Lake City
3 shared publications - Mark S. Slaughter
Department of Cardiovascular and Thoracic Surgery, University of Louisville, Louisville, Kentucky
3 shared publications - Palak Shah
Inova Schar Heart and Vascular
3 shared publications Christopher Cunningham
Clinical Trials Unit, University of Louisville, KY (C.C.).
2 shared publications
Latest Publications
- 23 November 2026
- Published by Wolters Kluwer Health in Circulation
VAD Wean Recovery Network: Long-Term Outcomes of LVAD Weaning for Myocardial Recovery
BACKGROUND: Myocardial recovery facilitated by the combination of a left ventricular assist device (LVAD) and guideline-directed medical therapy can lead to sufficient myocardial improvement. This in turn may allow LVAD weaning in appropriately selected patients with chronic advanced heart failure. However, sufficient data on the long-term outcomes of this therapeutic strategy are lacking, thereby hindering widespread adoption of LVAD weaning. We present the primary results from the VAD Wean Myocardial Recovery International Network examining long-term outcomes after LVAD weaning for myocardial recovery. METHODS: We studied 603 patients with chronic advanced heart failure from 60 international centers who underwent LVAD weaning. Preimplantation, LVAD cardiac recovery assessment, and postweaning patient characteristics and outcomes were analyzed. The primary outcome was event-free survival (free of heart transplantation or re-LVAD) in the weaned-for-recovery cohort. RESULTS: The LVAD-weaned cohort had a mean age of 42±15 years; 33% were female; and 9.4% had ischemic cardiomyopathy. At LVAD implantation, 88% had Intermacs (Interagency Registry for Mechanically Assisted Circulatory Support) profiles 1 to 3, and 41.6% required temporary mechanical circulatory support. Median LVAD support duration was 440 days (interquartile range, 261–770) before weaning. At the time of weaning, median left ventricular ejection fraction was 50% (interquartile range, 45%–57.5%), and left ventricular internal diastolic diameter was 48 mm (interquartile range, 43–53 mm). One-year survival after weaning was 91%, with 2.3% requiring re-LVAD and 3.7% requiring heart transplantation. In a secondary exploratory matched analysis against LVAD bridge-to-transplantation recipients from the International Society for Heart and Lung Transplantation registry, long-term survival was similar between groups. CONCLUSIONS: This international, multicenter analysis suggests that in patients with chronic advanced heart failure achieving myocardial recovery with LVAD support, device weaning yields excellent long-term outcomes. These findings may help address the underuse of LVADs as a bridge-to-recovery strategy in select patients.
- 23 November 2026
- Published by Wolters Kluwer Health in Circulation
VAD Wean Recovery Network: Long-Term Outcomes of LVAD Weaning for Myocardial Recovery
BACKGROUND: Myocardial recovery facilitated by the combination of a left ventricular assist device (LVAD) and guideline-directed medical therapy can lead to sufficient myocardial improvement. This in turn may allow LVAD weaning in appropriately selected patients with chronic advanced heart failure. However, sufficient data on the long-term outcomes of this therapeutic strategy are lacking, thereby hindering widespread adoption of LVAD weaning. We present the primary results from the VAD Wean Myocardial Recovery International Network examining long-term outcomes after LVAD weaning for myocardial recovery. METHODS: We studied 603 patients with chronic advanced heart failure from 60 international centers who underwent LVAD weaning. Preimplantation, LVAD cardiac recovery assessment, and postweaning patient characteristics and outcomes were analyzed. The primary outcome was event-free survival (free of heart transplantation or re-LVAD) in the weaned-for-recovery cohort. RESULTS: The LVAD-weaned cohort had a mean age of 42±15 years; 33% were female; and 9.4% had ischemic cardiomyopathy. At LVAD implantation, 88% had Intermacs (Interagency Registry for Mechanically Assisted Circulatory Support) profiles 1 to 3, and 41.6% required temporary mechanical circulatory support. Median LVAD support duration was 440 days (interquartile range, 261–770) before weaning. At the time of weaning, median left ventricular ejection fraction was 50% (interquartile range, 45%–57.5%), and left ventricular internal diastolic diameter was 48 mm (interquartile range, 43–53 mm). One-year survival after weaning was 91%, with 2.3% requiring re-LVAD and 3.7% requiring heart transplantation. In a secondary exploratory matched analysis against LVAD bridge-to-transplantation recipients from the International Society for Heart and Lung Transplantation registry, long-term survival was similar between groups. CONCLUSIONS: This international, multicenter analysis suggests that in patients with chronic advanced heart failure achieving myocardial recovery with LVAD support, device weaning yields excellent long-term outcomes. These findings may help address the underuse of LVADs as a bridge-to-recovery strategy in select patients.
- Open Access
- 17 April 2026
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 45 (10) , 1537-1549
Determining the individualized probability of myocardial recovery: The multicenter RecoverHeart calculator
- 17 April 2026
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 45 (10) , 1537-1549
Open AccessDetermining the individualized probability of myocardial recovery: The multicenter RecoverHeart calculator
- 6 May 2024
- Published by Elsevier in JACC: Heart Failure
- Vol. 12 (5) , 902-904
Reversing Advanced Heart Failure and its Practice?
- 6 May 2024
- Published by Elsevier in JACC: Heart Failure
- Vol. 12 (5) , 902-904
Reversing Advanced Heart Failure and its Practice?
- 7 November 2023
- Published by Wolters Kluwer Health in Circulation
- Vol. 148 (Suppl_1)
Abstract 16203: A Case for Cardiomems Use in Cardiac Amyloidosis to Prevent Hospitalization
- 7 November 2023
- Published by Wolters Kluwer Health in Circulation
- Vol. 148 (Suppl_1)
Abstract 16203: A Case for Cardiomems Use in Cardiac Amyloidosis to Prevent Hospitalization
- Top Cited Papers
- 25 May 2023
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 42 (7) , e1-e222
The 2023 International Society for Heart and Lung Transplantation Guidelines for Mechanical Circulatory Support: A 10- Year Update
- 25 May 2023
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 42 (7) , e1-e222
Top Cited PapersThe 2023 International Society for Heart and Lung Transplantation Guidelines for Mechanical Circulatory Support: A 10- Year Update
- 29 May 2022
- Published by Wiley in Artificial Organs
- Vol. 46 (12) , 2423-2431
Retrospective review of secondary prevention strategies for gastrointestinal bleeding and associated clinical outcomes in left ventricular assist device patients
Background Gastrointestinal bleeding (GIB) is one of the most common bleeding complications associated with left ventricular assist devices (LVAD). Currently, there is no strong evidence or clear guidance for which secondary GIB prophylaxis strategy should be implemented after the discontinuation of aspirin. Methods Our single-center study describes the outcomes of 26 LVAD patients who experienced a total of 49 GIB events: these individuals were either in Group-1 (lower INR target range) or Group-2 (lower INR target plus a hemostatic agent) as the secondary prophylaxis strategy. Each GIB event was considered an independent event. Outcomes assessed were bleeding reoccurrence rates, time to next GIB, acute GIB strategies, GIB-free days, thromboembolic events, survival, coagulation, and hematologic parameters. Results GIB reoccurrence rates were not statistically different: Group-1, 9 (40.9%), versus Group-2, 15 (55.6%); p = 0.308. Danazol was utilized 81.5% of the time as the designated hemostatic agent. Additionally, no significant differences were observed with all of our secondary outcome measures for bleeding, ischemic events, or survival. Conclusion While our study was not powered to assess the clinical outcomes related to survival and thromboembolic events, no discernable increased risk for ischemic events including pump thrombosis were observed. Our data suggest that a lower INR target range plus danazol does not confer any additional benefit over a lower INR target range only approach. The results of this report are hypothesis-generating and additional studies are warranted to elucidate the optimal antithrombotic strategy and role of hemostatic agents in reducing the risk of recurrent GIB events.
- 29 May 2022
- Published by Wiley in Artificial Organs
- Vol. 46 (12) , 2423-2431
Retrospective review of secondary prevention strategies for gastrointestinal bleeding and associated clinical outcomes in left ventricular assist device patients
Background Gastrointestinal bleeding (GIB) is one of the most common bleeding complications associated with left ventricular assist devices (LVAD). Currently, there is no strong evidence or clear guidance for which secondary GIB prophylaxis strategy should be implemented after the discontinuation of aspirin. Methods Our single-center study describes the outcomes of 26 LVAD patients who experienced a total of 49 GIB events: these individuals were either in Group-1 (lower INR target range) or Group-2 (lower INR target plus a hemostatic agent) as the secondary prophylaxis strategy. Each GIB event was considered an independent event. Outcomes assessed were bleeding reoccurrence rates, time to next GIB, acute GIB strategies, GIB-free days, thromboembolic events, survival, coagulation, and hematologic parameters. Results GIB reoccurrence rates were not statistically different: Group-1, 9 (40.9%), versus Group-2, 15 (55.6%); p = 0.308. Danazol was utilized 81.5% of the time as the designated hemostatic agent. Additionally, no significant differences were observed with all of our secondary outcome measures for bleeding, ischemic events, or survival. Conclusion While our study was not powered to assess the clinical outcomes related to survival and thromboembolic events, no discernable increased risk for ischemic events including pump thrombosis were observed. Our data suggest that a lower INR target range plus danazol does not confer any additional benefit over a lower INR target range only approach. The results of this report are hypothesis-generating and additional studies are warranted to elucidate the optimal antithrombotic strategy and role of hemostatic agents in reducing the risk of recurrent GIB events.
- Open Access
- 17 May 2022
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (10) , e023010
Prior Freezing Has Minimal Impact on the Contractile Properties of Permeabilized Human Myocardium
Background: Experiments measuring the contractile properties of human myocardium are important for translational research but complicated by the logistical difficulties of acquiring specimens. Accordingly, many groups perform contractile assays using samples that are acquired from patients at one institution and shipped to another institution for experiments. This necessitates freezing the samples and performing subsequent assays using chemically permeabilized preparations. It is unknown how prior freezing affects the contractile function of these preparations. Methods and Results: To examine the effects of freezing we measured the contractile function of never‐frozen and previously frozen myocardial samples. Samples of left ventricular tissue were obtained from 7 patients who were having a ventricular assist device implanted. Half of each sample was chemically permeabilized and used immediately for contractile assays. The other half of the sample was snap frozen in liquid nitrogen and maintained at –180 °C for at least 6 months before being thawed and tested in a second series of experiments. Maximum isometric force measured in pCa 4.5 solution, passive force measured in pCa 9.0 solution, and Hill coefficients were not influenced by prior freezing ( P =0.07, P =0.14, and P =0.27 respectively). pCa 50 in never‐frozen samples (6.11±0.04) was statistically greater ( P <0.001) than that measured after prior freezing (5.99±0.04) but the magnitude of the effect was only ≈0.1 pCa units. Conclusions: We conclude that prior freezing has minimal impact on the contractile properties that can be measured using chemically permeabilized human myocardium.
- 17 May 2022
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 11 (10) , e023010
Open AccessPrior Freezing Has Minimal Impact on the Contractile Properties of Permeabilized Human Myocardium
Background: Experiments measuring the contractile properties of human myocardium are important for translational research but complicated by the logistical difficulties of acquiring specimens. Accordingly, many groups perform contractile assays using samples that are acquired from patients at one institution and shipped to another institution for experiments. This necessitates freezing the samples and performing subsequent assays using chemically permeabilized preparations. It is unknown how prior freezing affects the contractile function of these preparations. Methods and Results: To examine the effects of freezing we measured the contractile function of never‐frozen and previously frozen myocardial samples. Samples of left ventricular tissue were obtained from 7 patients who were having a ventricular assist device implanted. Half of each sample was chemically permeabilized and used immediately for contractile assays. The other half of the sample was snap frozen in liquid nitrogen and maintained at –180 °C for at least 6 months before being thawed and tested in a second series of experiments. Maximum isometric force measured in pCa 4.5 solution, passive force measured in pCa 9.0 solution, and Hill coefficients were not influenced by prior freezing ( P =0.07, P =0.14, and P =0.27 respectively). pCa 50 in never‐frozen samples (6.11±0.04) was statistically greater ( P <0.001) than that measured after prior freezing (5.99±0.04) but the magnitude of the effect was only ≈0.1 pCa units. Conclusions: We conclude that prior freezing has minimal impact on the contractile properties that can be measured using chemically permeabilized human myocardium.
- 7 April 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (4) , S443
Bedside Ultrasound of Internal Jugular Vein for Right Ventricular Function Assessment
- 7 April 2022
- Published by Elsevier in The Journal of Heart and Lung Transplantation
- Vol. 41 (4) , S443
Bedside Ultrasound of Internal Jugular Vein for Right Ventricular Function Assessment
- 1 June 2021
- Published by Wolters Kluwer Health in Circulation
- Vol. 143 (22) , E1017-E1018
Response by Birks et al to Letters Regarding Article, “Prospective Multicenter Study of Myocardial Recovery Using Left Ventricular Assist Devices (RESTAGE-HF [Remission from Stage D Heart Failure]): Medium-Term and Primary End Point Results”
- 1 June 2021
- Published by Wolters Kluwer Health in Circulation
- Vol. 143 (22) , E1017-E1018
Response by Birks et al to Letters Regarding Article, “Prospective Multicenter Study of Myocardial Recovery Using Left Ventricular Assist Devices (RESTAGE-HF [Remission from Stage D Heart Failure]): Medium-Term and Primary End Point Results”
- Open Access
- 21 April 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (10) , 1159-1162
The Impact of Adverse Events on Functional Capacity and Quality of Life After HeartWare Ventricular Assist Device Implantation
Left ventricular assist devices (LVADs) improve quality of life (QoL) and functional capacity (FC) for patients with advanced heart failure. The association between adverse events (AEs) and changes in QoL and FC are unknown. Patients treated with the HeartWare ventricular assist device (HVAD) with paired 6-minute walk distance (6MWD, n = 263) and Kansas City Cardiomyopathy Questionnaires (KCCQ, n = 272) at baseline and 24 months in the ENDURANCE and ENDURANCE Supplemental Trial databases were included. Patients were stratified based upon occurrence of clinically significant AEs during the first 24 months of support and analyzed for the mean change in 6MWD and KCCQ. The impact of AE frequency on change in 6MWD and KCCQ from baseline to 24 months was evaluated. Of the AEs examined, only sepsis was associated with an improvement in 6MWD (109 m vs. 16 m, p = 0.002). Patients without improvement in 6MWD test from baseline to 24 months had significantly more AEs than those with FC improvement (p = 0.0002). Adverse events did not affect the KCCQ overall summary score. In this analysis, patients with fewer AEs had greater improvement in FC during the 24-month follow up. The frequency of AEs did not have a significant impact on QoL after LVAD implantation.
- 21 April 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 67 (10) , 1159-1162
Open AccessThe Impact of Adverse Events on Functional Capacity and Quality of Life After HeartWare Ventricular Assist Device Implantation
Left ventricular assist devices (LVADs) improve quality of life (QoL) and functional capacity (FC) for patients with advanced heart failure. The association between adverse events (AEs) and changes in QoL and FC are unknown. Patients treated with the HeartWare ventricular assist device (HVAD) with paired 6-minute walk distance (6MWD, n = 263) and Kansas City Cardiomyopathy Questionnaires (KCCQ, n = 272) at baseline and 24 months in the ENDURANCE and ENDURANCE Supplemental Trial databases were included. Patients were stratified based upon occurrence of clinically significant AEs during the first 24 months of support and analyzed for the mean change in 6MWD and KCCQ. The impact of AE frequency on change in 6MWD and KCCQ from baseline to 24 months was evaluated. Of the AEs examined, only sepsis was associated with an improvement in 6MWD (109 m vs. 16 m, p = 0.002). Patients without improvement in 6MWD test from baseline to 24 months had significantly more AEs than those with FC improvement (p = 0.0002). Adverse events did not affect the KCCQ overall summary score. In this analysis, patients with fewer AEs had greater improvement in FC during the 24-month follow up. The frequency of AEs did not have a significant impact on QoL after LVAD implantation.