Noriyo Colley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Noriyo Colley has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Shinji Ninomiya
Department of Clinical Engineering, Hiroshima International University
3 shared publications - Shunsuke Komizunai
Faculty of Engineering and Design, Kagawa University, Takamatsu, Japan
3 shared publications Atsushi Konno
Affiliation Division of System Science and Informatics, Graduate School of Information Science and Technology, Hokkaido University, Sapporo, Japan
2 shared publicationsSatoshi Kanai
Affiliation Division of System Science and Informatics, Graduate School of Information Science and Technology, Hokkaido University, Sapporo, Japan
2 shared publicationsShinji Ninomiya
Affiliation Department of Medical Science and Technology, Faculty of Health Sciences, Hiroshima International University, Hiroshima, Japan
2 shared publicationsShunsuke Komizunai
Affiliation Division of System Science and Informatics, Graduate School of Information Science and Technology, Hokkaido University, Sapporo, Japan
2 shared publications
Latest Publications
- Open Access
Experimental Development of XR Enteral Feeding Function for an Endotracheal Suctioning Training Environment Simulator
Background: Existing XR simulators for enteral feeding rely mainly on self-reported learning outcomes and procedural checklists. As a result, they offer limited opportunities to capture objective behavioral data or to present dynamic patient reactions. This two-stage pilot study evaluated an XR-based gastrostomy tube-feeding simulator (ESTE-TF) that integrates sensor-derived performance metrics and two biological-reaction presentation modalities (projection mapping and tablet display). Methods: In Experiment 1, nursing students completed pre- and post-experience questionnaires assessing perceived learning across seven domains, alongside sensor-based measurements of feeding-start timing, dosing-rate characteristics, and total procedure time. Experiment 2 employed a tablet-based version with four learning items assessed for students and post-experience evaluations collected from registered nurses. Participants also compared the two XR presentation methods. Results: Students demonstrated perceived learning gains of small-to-large magnitude across both experiments (Experiment 1: d = 0.455–0.974; Experiment 2: d = 0.014–0.886), with wide 95% confidence intervals reflecting the exploratory nature of this pilot work. Sensor-derived data showed greater dosing-rate variability and longer procedure times among students than nurses. Participants reported that projection mapping offered a more embodied experience, whereas tablet displays provided clearer visibility. Conclusions: These findings indicate the feasibility and preliminary educational potential of integrating sensing technologies with XR-based biological-reaction presentation for gastrostomy-feeding training. Given the small samples and non-validated measures, results should be interpreted as exploratory. Future research will refine sensor accuracy, establish standardized performance metrics, and evaluate learning outcomes using validated instruments and controlled study designs.
Open AccessExperimental Development of XR Enteral Feeding Function for an Endotracheal Suctioning Training Environment Simulator
Background: Existing XR simulators for enteral feeding rely mainly on self-reported learning outcomes and procedural checklists. As a result, they offer limited opportunities to capture objective behavioral data or to present dynamic patient reactions. This two-stage pilot study evaluated an XR-based gastrostomy tube-feeding simulator (ESTE-TF) that integrates sensor-derived performance metrics and two biological-reaction presentation modalities (projection mapping and tablet display). Methods: In Experiment 1, nursing students completed pre- and post-experience questionnaires assessing perceived learning across seven domains, alongside sensor-based measurements of feeding-start timing, dosing-rate characteristics, and total procedure time. Experiment 2 employed a tablet-based version with four learning items assessed for students and post-experience evaluations collected from registered nurses. Participants also compared the two XR presentation methods. Results: Students demonstrated perceived learning gains of small-to-large magnitude across both experiments (Experiment 1: d = 0.455–0.974; Experiment 2: d = 0.014–0.886), with wide 95% confidence intervals reflecting the exploratory nature of this pilot work. Sensor-derived data showed greater dosing-rate variability and longer procedure times among students than nurses. Participants reported that projection mapping offered a more embodied experience, whereas tablet displays provided clearer visibility. Conclusions: These findings indicate the feasibility and preliminary educational potential of integrating sensing technologies with XR-based biological-reaction presentation for gastrostomy-feeding training. Given the small samples and non-validated measures, results should be interpreted as exploratory. Future research will refine sensor accuracy, establish standardized performance metrics, and evaluate learning outcomes using validated instruments and controlled study designs.
- Open Access
A Unified XAI-LLM Approach for EndotrachealSuctioning Activity Recognition
Endotracheal suctioning (ES) is an invasive yet essential clinical procedure that requires a high degree of skill to minimize patient risk - particularly in home care and educational settings, where consistent supervision may be limited. Despite its critical importance, automated recognition and feedback systems for ES training remain underexplored. To address this gap, this study proposes a unified, LLM-centered framework for video-based activity recognition benchmarked against conventional machine learning and deep learning approaches, and a pilot study on feedback generation. Within this framework, the Large Language Model (LLM) serves as the central reasoning module, performing both spatiotemporal activity recognition and explainable decision analysis from video data. Furthermore, the LLM is capable of verbalizing feedback in natural language, thereby translating complex technical insights into accessible, human-understandable guidance for trainees. Experimental results demonstrate that the proposed LLM-based approach outperforms baseline models, achieving an improvement of approximately 15-20\% in both accuracy and F1 score. Beyond recognition, the framework incorporates a pilot student-support module built upon anomaly detection and explainable AI (XAI) principles, which provides automated, interpretable feedback highlighting correct actions and suggesting targeted improvements. Collectively, these contributions establish a scalable, interpretable, and data-driven foundation for advancing nursing education, enhancing training efficiency, and ultimately improving patient safety.
Open AccessA Unified XAI-LLM Approach for EndotrachealSuctioning Activity Recognition
Endotracheal suctioning (ES) is an invasive yet essential clinical procedure that requires a high degree of skill to minimize patient risk - particularly in home care and educational settings, where consistent supervision may be limited. Despite its critical importance, automated recognition and feedback systems for ES training remain underexplored. To address this gap, this study proposes a unified, LLM-centered framework for video-based activity recognition benchmarked against conventional machine learning and deep learning approaches, and a pilot study on feedback generation. Within this framework, the Large Language Model (LLM) serves as the central reasoning module, performing both spatiotemporal activity recognition and explainable decision analysis from video data. Furthermore, the LLM is capable of verbalizing feedback in natural language, thereby translating complex technical insights into accessible, human-understandable guidance for trainees. Experimental results demonstrate that the proposed LLM-based approach outperforms baseline models, achieving an improvement of approximately 15-20\% in both accuracy and F1 score. Beyond recognition, the framework incorporates a pilot student-support module built upon anomaly detection and explainable AI (XAI) principles, which provides automated, interpretable feedback highlighting correct actions and suggesting targeted improvements. Collectively, these contributions establish a scalable, interpretable, and data-driven foundation for advancing nursing education, enhancing training efficiency, and ultimately improving patient safety.
- Open Access
- 1 January 2026
- Published by Elsevier in Teaching and Learning in Nursing
- Vol. 21 (2) , e935-e947
Virtual reality in undergraduate and postgraduate nursing education:A scoping review integrating data mining for topic discovery
- 1 January 2026
- Published by Elsevier in Teaching and Learning in Nursing
- Vol. 21 (2) , e935-e947
Open AccessVirtual reality in undergraduate and postgraduate nursing education:A scoping review integrating data mining for topic discovery
- Open Access
- 21 August 2024
- Published by IntechOpen
Nursing XR Simulator for Diversity, Equity, and Inclusion: A New Purpose of Future Technology Development
XR is a term within the spectrum of virtual reality (VR), mixed reality (MR), and augmented reality (AR). In 2015, Endotracheal Suctioning Training Environment SIMulator (ESTE-SIM) project team was established (PI: Noriyo Colley), which consisted of a wide range of disciplines including nursing science, information science, and healthcare engineering to promote the development of a pedagogical environment for quality care through simulation education. Mutual recognition was found that a digital transformation plays an important role to mitigate the risks of global shortages of nurses and healthcare faculty due to pandemic, ultra-aging society, and technology dependent children such as children with home mechanical ventilators. Nursing XR simulators are being developed for Diversity, Equity & Inclusion, which is a new purpose of future technology development.
- 21 August 2024
- Published by IntechOpen
Open AccessNursing XR Simulator for Diversity, Equity, and Inclusion: A New Purpose of Future Technology Development
XR is a term within the spectrum of virtual reality (VR), mixed reality (MR), and augmented reality (AR). In 2015, Endotracheal Suctioning Training Environment SIMulator (ESTE-SIM) project team was established (PI: Noriyo Colley), which consisted of a wide range of disciplines including nursing science, information science, and healthcare engineering to promote the development of a pedagogical environment for quality care through simulation education. Mutual recognition was found that a digital transformation plays an important role to mitigate the risks of global shortages of nurses and healthcare faculty due to pandemic, ultra-aging society, and technology dependent children such as children with home mechanical ventilators. Nursing XR simulators are being developed for Diversity, Equity & Inclusion, which is a new purpose of future technology development.
- 16 July 2023
- Published by Springer Nature
- p. 431-439
A Mentoring Relationship to Support the Introduction of the Nurse Practitioner Role in Japan
- 16 July 2023
- Published by Springer Nature
- p. 431-439
A Mentoring Relationship to Support the Introduction of the Nurse Practitioner Role in Japan
- Open Access
- 17 February 2023
- Published by Japan Society of Nursing Research in Journal of International Nursing Research
- Vol. 2 (1) , e2021-0016
Proficiency evaluation of simulation education on the entire tracheal suctioning process using a motion capture system and a catheter control sensing device
Objective: We developed a suctioning catheter control sensing device given the increasing demand for skilled home-based healthcare techniques, such as tracheal suctioning. This study evaluated the proficiency of the entire tracheal suctioning process between expert and novice groups via the suctioning catheter control sensing device and a motion capture system. Our hypothesis is that motion capture can measure the proficiency of tracheal suctioning despite the biological reactions of the simulator and the characteristics of participants. Methods: Nine expert nurses, each with more than three years of clinical experience in tracheal suctioning, and 13 nursing students from an urban university nursing department participated. The performance time, pelvic forward bending angle, travel distance, posing time, posing frequency of bilateral dorsum manus, and suctioning catheter control between the two groups with/without simulated biological reactions were analyzed. Results: The two-way analysis of variance demonstrated that the biological reactions (or lack thereof) and the proficiency level did not interact. The main effect of performance time, posing time, and posing frequency was statistically significant; experts performed tracheal suctioning more expeditiously and skillfully. The sensing device could detect hesitance or rough catheter control. Conclusions: Our results indicated that performance time, posing time, and posing frequency could serve as proficiency criteria with/out biological reactions. Additional studies are required to establish a quantitative education evaluation method to determine clinically reliable proficiency levels of tracheal suctioning.
- 17 February 2023
- Published by Japan Society of Nursing Research in Journal of International Nursing Research
- Vol. 2 (1) , e2021-0016
Open AccessProficiency evaluation of simulation education on the entire tracheal suctioning process using a motion capture system and a catheter control sensing device
Objective: We developed a suctioning catheter control sensing device given the increasing demand for skilled home-based healthcare techniques, such as tracheal suctioning. This study evaluated the proficiency of the entire tracheal suctioning process between expert and novice groups via the suctioning catheter control sensing device and a motion capture system. Our hypothesis is that motion capture can measure the proficiency of tracheal suctioning despite the biological reactions of the simulator and the characteristics of participants. Methods: Nine expert nurses, each with more than three years of clinical experience in tracheal suctioning, and 13 nursing students from an urban university nursing department participated. The performance time, pelvic forward bending angle, travel distance, posing time, posing frequency of bilateral dorsum manus, and suctioning catheter control between the two groups with/without simulated biological reactions were analyzed. Results: The two-way analysis of variance demonstrated that the biological reactions (or lack thereof) and the proficiency level did not interact. The main effect of performance time, posing time, and posing frequency was statistically significant; experts performed tracheal suctioning more expeditiously and skillfully. The sensing device could detect hesitance or rough catheter control. Conclusions: Our results indicated that performance time, posing time, and posing frequency could serve as proficiency criteria with/out biological reactions. Additional studies are required to establish a quantitative education evaluation method to determine clinically reliable proficiency levels of tracheal suctioning.
- Open Access
- 29 March 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (3) , e0249010
Construction of a detachable artificial trachea model for three age groups for use in an endotracheal suctioning training environment simulator
Tracheal suctioning is an important procedure to maintain airway patency by removing secretions. Today, suctioning operators include not only medical staff, but also family caregivers. The use of a simulation system has been noted to be the most effective way to learn the tracheal suctioning technique for operators. While the size of the trachea varies across different age groups, the artificial trachea model in the simulation system has only one fixed model. Thus, this study aimed to construct multiple removable trachea models according to different age groups. We enrolled 20 patients who had previously received proton beam therapy in our institution and acquired the treatment planning computed tomography (CT) image data. To construct the artificial trachea model for three age groups (children, adolescents and young adults, and adults), we analyzed the three-dimensional coordinates of the entire trachea, tracheal carina, and the end of the main bronchus. We also analyzed the diameter of the trachea and main bronchus. Finally, we evaluated the accuracy of the model by analyzing the difference between the constructed model and actual measurements. The trachea model was 8 cm long for children and 12 cm for adolescents and young adults, and for adults. The angle between the trachea and bed was about 20 degrees, regardless of age. The mean model accuracy was less than 0.4 cm. We constructed detachable artificial trachea models for three age groups for implementation in the endotracheal suctioning training environment simulator (ESTE-SIM) based on the treatment planning CT image. Our constructed artificial trachea models will be able to provide a simulation environment for various age groups in the ESTE-SIM.
- 29 March 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (3) , e0249010
Open AccessConstruction of a detachable artificial trachea model for three age groups for use in an endotracheal suctioning training environment simulator
Tracheal suctioning is an important procedure to maintain airway patency by removing secretions. Today, suctioning operators include not only medical staff, but also family caregivers. The use of a simulation system has been noted to be the most effective way to learn the tracheal suctioning technique for operators. While the size of the trachea varies across different age groups, the artificial trachea model in the simulation system has only one fixed model. Thus, this study aimed to construct multiple removable trachea models according to different age groups. We enrolled 20 patients who had previously received proton beam therapy in our institution and acquired the treatment planning computed tomography (CT) image data. To construct the artificial trachea model for three age groups (children, adolescents and young adults, and adults), we analyzed the three-dimensional coordinates of the entire trachea, tracheal carina, and the end of the main bronchus. We also analyzed the diameter of the trachea and main bronchus. Finally, we evaluated the accuracy of the model by analyzing the difference between the constructed model and actual measurements. The trachea model was 8 cm long for children and 12 cm for adolescents and young adults, and for adults. The angle between the trachea and bed was about 20 degrees, regardless of age. The mean model accuracy was less than 0.4 cm. We constructed detachable artificial trachea models for three age groups for implementation in the endotracheal suctioning training environment simulator (ESTE-SIM) based on the treatment planning CT image. Our constructed artificial trachea models will be able to provide a simulation environment for various age groups in the ESTE-SIM.
- Open Access
- 24 April 2020
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (3) , 340-347
Effective Catheter Manoeuvre for the Removal of Phlegm by Suctioning: A Biomechanical Analysis of Experts and Novices
Purpose The aim of this study was to determine the effective biomechanical technique for suctioning phlegm. Methods A novel tracheal suctioning simulator combined with a motion capture system was used to calculate the amount of simulated phlegm suctioned and the biomechanical parameters of the associated suctioning manoeuvre. A laboratory study, including 12 nurses with > 3 years of suctioning experience and 12 nursing students without any clinical suctioning experience, was conducted. The amount of phlegm suctioned, the maximum length of catheter insertion, and the biomechanical parameters of hand movement were calculated. Results The mean amount of phlegm suctioned per second was significantly larger in the experienced group than in the non-experienced group. The amount of phlegm suctioned correlated positively with the length of the vertical path of motion of the wrist and forearm, and with the angular velocity of thumb rotation in both the groups. Conclusion Greater vertical motion of the wrist and thumb rotation improved the effectiveness of phlegm suctioning and prevented the need for deep suctioning, which is unsafe.
- 24 April 2020
- Published by Springer Nature in Journal of Medical and Biological Engineering
- Vol. 40 (3) , 340-347
Open AccessEffective Catheter Manoeuvre for the Removal of Phlegm by Suctioning: A Biomechanical Analysis of Experts and Novices
Purpose The aim of this study was to determine the effective biomechanical technique for suctioning phlegm. Methods A novel tracheal suctioning simulator combined with a motion capture system was used to calculate the amount of simulated phlegm suctioned and the biomechanical parameters of the associated suctioning manoeuvre. A laboratory study, including 12 nurses with > 3 years of suctioning experience and 12 nursing students without any clinical suctioning experience, was conducted. The amount of phlegm suctioned, the maximum length of catheter insertion, and the biomechanical parameters of hand movement were calculated. Results The mean amount of phlegm suctioned per second was significantly larger in the experienced group than in the non-experienced group. The amount of phlegm suctioned correlated positively with the length of the vertical path of motion of the wrist and forearm, and with the angular velocity of thumb rotation in both the groups. Conclusion Greater vertical motion of the wrist and thumb rotation improved the effectiveness of phlegm suctioning and prevented the need for deep suctioning, which is unsafe.
- Open Access
- 1 January 2020
- Published by SAGE Publications in SAGE Open Nursing
- Vol. 6
Relationship Between Tracheal Suctioning Catheter Motion and Secretion Amount Based on Viscosity
Background: To provide safe tracheal suctioning, the American Association of Respiratory Care guideline discusses the length of suctioning catheter, but the most effective tracheal suctioning catheter technique is still unknown. Objective: The aim of this study is to compare the amount of simulated secretion produced by five different handlings of a catheter at two different viscosities and in two different models to discover the most effective suctioning maneuver in the various mucus conditions. Design: In vitro experimental design. Methods: The amount of secretion aspirated by our researcher's manipulation of a suctioning catheter was measured. The tip of the catheter was recorded using a high-speed video camera to visualize the secretion motion. Results: The most effective suctioning technique differed depending on the viscosity of the secretion. There were no significant differences between five suctioning methods applied to high-viscosity phlegm in a tracheal membrane model, but the flexion technique was the most efficient for low-viscosity secretion. Conclusions: Our results imply that the flexion technique was reasonably safe and the most effective of these five methods for low-viscosity secretion.
- 1 January 2020
- Published by SAGE Publications in SAGE Open Nursing
- Vol. 6
Open AccessRelationship Between Tracheal Suctioning Catheter Motion and Secretion Amount Based on Viscosity
Background: To provide safe tracheal suctioning, the American Association of Respiratory Care guideline discusses the length of suctioning catheter, but the most effective tracheal suctioning catheter technique is still unknown. Objective: The aim of this study is to compare the amount of simulated secretion produced by five different handlings of a catheter at two different viscosities and in two different models to discover the most effective suctioning maneuver in the various mucus conditions. Design: In vitro experimental design. Methods: The amount of secretion aspirated by our researcher's manipulation of a suctioning catheter was measured. The tip of the catheter was recorded using a high-speed video camera to visualize the secretion motion. Results: The most effective suctioning technique differed depending on the viscosity of the secretion. There were no significant differences between five suctioning methods applied to high-viscosity phlegm in a tracheal membrane model, but the flexion technique was the most efficient for low-viscosity secretion. Conclusions: Our results imply that the flexion technique was reasonably safe and the most effective of these five methods for low-viscosity secretion.