Sebastiaan Van Nuffel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sebastiaan Van Nuffel has a total of 65 co-authors. Here are the top co-authors by number of shared publications:
- Alain Brunelle
Sorbonne Université, CNRS, Laboratoire d’Archéologie Moléculaire et Structurale, Paris, France
11 shared publications - Caroline Bouvier
Maastricht MultiModal Molecular Imaging Institute (M4i), Maastricht University 1 , Maastricht, 6229ER
8 shared publications - Ian G. M. Anthony
Maastricht University
4 shared publications - Ron M. A. Heeren
The Maastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry (IMS), Maastricht University, Maastricht, The Netherlands
3 shared publications - David Touboul
Laboratoire de Chimie Moléculaire (LCM), CNRS, Ecole Polytechnique, Institut Polytechnique de Paris, Palaiseau, France
2 shared publications - Edith Sandström
EastChem School of Chemistry, University of Edinburgh, Edinburgh EH9 3FJ, UK
2 shared publications
Latest Publications
- 18 November 2025
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 32 (2)
ToF-SIMS reference spectra of perfluorosulfonic acids in both polarities
Perfluorosulfonic acids (PFSAs) are chemical compounds of the formula CnF(2n + 1)SO3H. PFSAs with six or more perfluorinated carbon atoms are referred to as long chain. These chemical compounds belong to the family of per- and polyfluoroalkyl substances, also known as so-called forever chemicals. Reference spectra in both polarities are presented of the potassium salts of one long-chain perfluorosulfonic acid, namely, perfluorooctanesulfonic acid with an eight-carbon fluorocarbon chain, and one short-chain perfluorosulfonic acid, namely, perfluorobutanesulfonic acid with a four-carbon fluorocarbon chain.
- 18 November 2025
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 32 (2)
ToF-SIMS reference spectra of perfluorosulfonic acids in both polarities
Perfluorosulfonic acids (PFSAs) are chemical compounds of the formula CnF(2n + 1)SO3H. PFSAs with six or more perfluorinated carbon atoms are referred to as long chain. These chemical compounds belong to the family of per- and polyfluoroalkyl substances, also known as so-called forever chemicals. Reference spectra in both polarities are presented of the potassium salts of one long-chain perfluorosulfonic acid, namely, perfluorooctanesulfonic acid with an eight-carbon fluorocarbon chain, and one short-chain perfluorosulfonic acid, namely, perfluorobutanesulfonic acid with a four-carbon fluorocarbon chain.
- 5 September 2025
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 32 (2)
ToF-SIMS spectra of typical substrates in both polarities: Si wafer, Au-coated glass, and ITO-coated glass
ToF-SIMS is a surface analysis technique, and as a result, many samples need to be spotted or mounted onto a suitable substrate. Different substrates can be used for ToF-SIMS analysis, and it is essential to properly assign the characteristic chemical signals from the substrate to distinguish them from the sample analyte ions. Here, the authors provide a reference database that provides ToF-SIMS spectra for three widely used substrates in positive and negative polarities. The six spectra were acquired using a 30 keV Bi3+ primary ion beam, with Ar gas cluster ion beam sputter cleaning of the surfaces before analysis.
- 5 September 2025
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 32 (2)
ToF-SIMS spectra of typical substrates in both polarities: Si wafer, Au-coated glass, and ITO-coated glass
ToF-SIMS is a surface analysis technique, and as a result, many samples need to be spotted or mounted onto a suitable substrate. Different substrates can be used for ToF-SIMS analysis, and it is essential to properly assign the characteristic chemical signals from the substrate to distinguish them from the sample analyte ions. Here, the authors provide a reference database that provides ToF-SIMS spectra for three widely used substrates in positive and negative polarities. The six spectra were acquired using a 30 keV Bi3+ primary ion beam, with Ar gas cluster ion beam sputter cleaning of the surfaces before analysis.
- 1 June 2025
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 32 (1)
Tof-SIMS spectra of historical inorganic pigments
- 1 June 2025
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 32 (1)
Tof-SIMS spectra of historical inorganic pigments
- Open Access
- 6 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (2) , 1054-1058
ToF-SIMS Parallel Imaging MS/MS of Lead Soaps in Embedded Paint Cross Sections
In the field of cultural heritage, and more specifically in oil paintings, the ability to unambiguously identify and locate metal soaps is of great interest for a better understanding of painting degradation. Here, we demonstrate the use of a Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) instrument capable of tandem mass spectrometry imaging for the unambiguous identification and localization of lead soaps in cross sections of samples of old oil paintings at high spatial resolution. It is shown that the specific fragmentation pattern of lead soaps is dictated by the loss of the lead ion and that fragmentation occurs on the hydrocarbon chains of the fatty acids. This method offers new opportunities for a better understanding of the chemical changes in aging oil paint samples as well as investigation of organic pigments and binders.
- 6 January 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (2) , 1054-1058
Open AccessToF-SIMS Parallel Imaging MS/MS of Lead Soaps in Embedded Paint Cross Sections
In the field of cultural heritage, and more specifically in oil paintings, the ability to unambiguously identify and locate metal soaps is of great interest for a better understanding of painting degradation. Here, we demonstrate the use of a Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) instrument capable of tandem mass spectrometry imaging for the unambiguous identification and localization of lead soaps in cross sections of samples of old oil paintings at high spatial resolution. It is shown that the specific fragmentation pattern of lead soaps is dictated by the loss of the lead ion and that fragmentation occurs on the hydrocarbon chains of the fatty acids. This method offers new opportunities for a better understanding of the chemical changes in aging oil paint samples as well as investigation of organic pigments and binders.
- Open Access
- 28 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (45) , 18037-18042
Improvements in Fast Mass Microscopy for Large-Area Samples
Mass spectrometry imaging (MSI) is a technique that analyzes the chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, the spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on the high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique that decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time, which enables increased imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system, including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm2 sample area to be imaged at a 1 μm pixel size in n = 3) μm.
- 28 October 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (45) , 18037-18042
Open AccessImprovements in Fast Mass Microscopy for Large-Area Samples
Mass spectrometry imaging (MSI) is a technique that analyzes the chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, the spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on the high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique that decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time, which enables increased imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system, including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm2 sample area to be imaged at a 1 μm pixel size in n = 3) μm.
- Open Access
- 25 October 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (12) , 2801-2814
The Application of a Random Forest Classifier to ToF-SIMS Imaging Data
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging is a potent analytical tool that provides spatially resolved chemical information on surfaces at the microscale. However, the hyperspectral nature of ToF-SIMS datasets can be challenging to analyze and interpret. Both supervised and unsupervised machine learning (ML) approaches are increasingly useful to help analyze ToF-SIMS data. Random Forest (RF) has emerged as a robust and powerful algorithm for processing mass spectrometry data. This machine learning approach offers several advantages, including accommodating nonlinear relationships, robustness to outliers in the data, managing the high-dimensional feature space, and mitigating the risk of overfitting. The application of RF to ToF-SIMS imaging facilitates the classification of complex chemical compositions and the identification of features contributing to these classifications. This tutorial aims to assist nonexperts in either machine learning or ToF-SIMS to apply Random Forest to complex ToF-SIMS datasets.
- 25 October 2024
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 35 (12) , 2801-2814
Open AccessThe Application of a Random Forest Classifier to ToF-SIMS Imaging Data
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging is a potent analytical tool that provides spatially resolved chemical information on surfaces at the microscale. However, the hyperspectral nature of ToF-SIMS datasets can be challenging to analyze and interpret. Both supervised and unsupervised machine learning (ML) approaches are increasingly useful to help analyze ToF-SIMS data. Random Forest (RF) has emerged as a robust and powerful algorithm for processing mass spectrometry data. This machine learning approach offers several advantages, including accommodating nonlinear relationships, robustness to outliers in the data, managing the high-dimensional feature space, and mitigating the risk of overfitting. The application of RF to ToF-SIMS imaging facilitates the classification of complex chemical compositions and the identification of features contributing to these classifications. This tutorial aims to assist nonexperts in either machine learning or ToF-SIMS to apply Random Forest to complex ToF-SIMS datasets.
- Open Access
- 31 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
The Application of a Random Forest Classifier to ToF-SIMS Imaging Data
Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) imaging is a potent analytical tool that provides spatially resolved chemical information of surfaces at the microscale. However, the hyperspectral nature of ToF-SIMS datasets constitutes can be challenging to analyze and interpret. Both supervised and unsupervised Machine Learning (ML) approaches are increasingly useful to help analyze ToF-SIMS data. Random Forest (RF) has emerged as a robust and powerful algorithm for processing mass spectrometry data. This machine learning approach offers several advantages, including the accommodating non-linear relationships, robustness to outliers in the data, managing the high-dimensional feature space, and mitigating the risk of overfitting. The application of RF to ToF-SIMS imaging facilitates the classification of complex chemical compositions and the identification of features contributing to these classifications. This tutorial aims to assist non-experts in either machine learning or ToF-SIMS to apply Random Forest to complex ToF-SIMS datasets.
- 31 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessThe Application of a Random Forest Classifier to ToF-SIMS Imaging Data
Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) imaging is a potent analytical tool that provides spatially resolved chemical information of surfaces at the microscale. However, the hyperspectral nature of ToF-SIMS datasets constitutes can be challenging to analyze and interpret. Both supervised and unsupervised Machine Learning (ML) approaches are increasingly useful to help analyze ToF-SIMS data. Random Forest (RF) has emerged as a robust and powerful algorithm for processing mass spectrometry data. This machine learning approach offers several advantages, including the accommodating non-linear relationships, robustness to outliers in the data, managing the high-dimensional feature space, and mitigating the risk of overfitting. The application of RF to ToF-SIMS imaging facilitates the classification of complex chemical compositions and the identification of features contributing to these classifications. This tutorial aims to assist non-experts in either machine learning or ToF-SIMS to apply Random Forest to complex ToF-SIMS datasets.
- Open Access
- 10 July 2024
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 31 (2)
Tof-SIMS spectra of historical inorganic pigments: Copper-, zinc-, arsenic-, and phosphorus-containing pigments in negative polarity
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is increasingly used to analyze cultural heritage materials because it can simultaneously detect organic and inorganic materials while mapping them on a surface. The precise identification of a pigment in a specific layer of a painting or of remaining color on a statue can inform about the technique used or the time of manufacture as well as expose possible forgeries when anachronistic ingredients are identified. Reference spectra are required to confidently identify a given pigment using ToF-SIMS. This paper focuses on eight pigments containing copper, zinc, arsenic, or phosphate, all manufactured following historical recipes. The negative polarity ToF-SIMS reference spectra using a Bi3+ primary ion species are presented here. Presented together, these spectra and corresponding tables of secondary ions provide a valuable help in differentiating these pigments because copper, zinc, arsenic, or phosphate, combined with oxygen, share many mass interferences.
- 10 July 2024
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 31 (2)
Open AccessTof-SIMS spectra of historical inorganic pigments: Copper-, zinc-, arsenic-, and phosphorus-containing pigments in negative polarity
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is increasingly used to analyze cultural heritage materials because it can simultaneously detect organic and inorganic materials while mapping them on a surface. The precise identification of a pigment in a specific layer of a painting or of remaining color on a statue can inform about the technique used or the time of manufacture as well as expose possible forgeries when anachronistic ingredients are identified. Reference spectra are required to confidently identify a given pigment using ToF-SIMS. This paper focuses on eight pigments containing copper, zinc, arsenic, or phosphate, all manufactured following historical recipes. The negative polarity ToF-SIMS reference spectra using a Bi3+ primary ion species are presented here. Presented together, these spectra and corresponding tables of secondary ions provide a valuable help in differentiating these pigments because copper, zinc, arsenic, or phosphate, combined with oxygen, share many mass interferences.
- Open Access
- 8 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Improvements in fast mass microscopy for large-area samples
Mass spectrometry imaging (MSI) is a technique that analyzes chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe-mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique which decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time which enables increased the imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm2 sample area to be imaged at a 1 µm pixel size in <4.5 min. Linear encoders also enable the alignment of multi-pass images that increase image homogeneity and chemical signal. The applicability of FMM to large area samples has made it important to define the tolerance to height variations of the technique, which was determined to be at least 218 µm.
- 8 July 2024
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessImprovements in fast mass microscopy for large-area samples
Mass spectrometry imaging (MSI) is a technique that analyzes chemical information and spatial distribution of surface analytes. Most MSI studies are conducted in microprobe-mode, in which a mass spectrum is collected for each pixel to create a mass image. Thus, spatial resolution, sample imaging area, and imaging speed are linked. In this mode, halving the pixel size quadruples the analytical time, which presents a practical limit on high spatial resolution MSI throughput. Fast mass microscopy (FMM) is, in contrast, a microscope-mode MSI technique which decouples spatial resolution and imaging speed. FMM circumvents the linear-quadratic relationship of pixel size and analytical time which enables increased the imaging size area and the analytical speed achievable. In this study, we implement instrument modifications to the FMM system including the addition of linear encoders that enable roughly 8.5× faster imaging than was previously achieved, allowing a 42.5 × 26 mm2 sample area to be imaged at a 1 µm pixel size in <4.5 min. Linear encoders also enable the alignment of multi-pass images that increase image homogeneity and chemical signal. The applicability of FMM to large area samples has made it important to define the tolerance to height variations of the technique, which was determined to be at least 218 µm.
- Open Access
- 3 July 2024
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 31 (2)
Tof-SIMS spectra of historical inorganic pigments: Copper-, zinc-, arsenic-, and phosphorus-containing pigments in positive polarity
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is increasingly used to analyze cultural heritage materials because it can simultaneously detect organic and inorganic materials while mapping them on a surface. The precise identification of a pigment in a specific layer of a painting or of remaining color on a statue can inform about the technique used or the time of manufacture as well as expose possible forgeries when anachronistic ingredients are identified. Reference spectra are required to confidently identify a given pigment using ToF-SIMS. This paper focuses on eight pigments containing copper, zinc, arsenic, or phosphate, all manufactured following historical recipes. The positive polarity ToF-SIMS reference spectra using a Bi3 + primary ion species are presented here. Presented together, these spectra and corresponding tables of secondary ions provide a valuable help in differentiating these pigments, because copper, zinc, arsenic, or phosphate, combined with oxygen, share many mass interferences.
- 3 July 2024
- Published by American Vacuum Society in Surface Science Spectra
- Vol. 31 (2)
Open AccessTof-SIMS spectra of historical inorganic pigments: Copper-, zinc-, arsenic-, and phosphorus-containing pigments in positive polarity
Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is increasingly used to analyze cultural heritage materials because it can simultaneously detect organic and inorganic materials while mapping them on a surface. The precise identification of a pigment in a specific layer of a painting or of remaining color on a statue can inform about the technique used or the time of manufacture as well as expose possible forgeries when anachronistic ingredients are identified. Reference spectra are required to confidently identify a given pigment using ToF-SIMS. This paper focuses on eight pigments containing copper, zinc, arsenic, or phosphate, all manufactured following historical recipes. The positive polarity ToF-SIMS reference spectra using a Bi3 + primary ion species are presented here. Presented together, these spectra and corresponding tables of secondary ions provide a valuable help in differentiating these pigments, because copper, zinc, arsenic, or phosphate, combined with oxygen, share many mass interferences.