Zaihua Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zaihua Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Guohui Cao
School of Civil Engineering, Hunan City University, Yiyang 413000, China
3 shared publications - Guangfei Chen
Key Laboratory of Dynamics and Reliability of Engineering Structures of College of Hunan Province, Xiangtan University, Xiangtan 411105, China
2 shared publications Ran He
Civil Engineering College, Hunan City University, Yiyang, Hunan, China
2 shared publications- Ran He
College of Civil Engineering, Hunan City University, Yiyang 413000, China
2 shared publications - Rongguo Zhao
Key Laboratory of Dynamics and Reliability of Engineering Structures of College of Hunan Province, Xiangtan University, Xiangtan, China
2 shared publications - Wei Luo
Key Laboratory of Dynamics and Reliability of Engineering Structures of College of Hunan Province, Xiangtan University, Xiangtan 411105, China
2 shared publications
Latest Publications
- 5 December 2025
- Published by Springer Nature in Materials and Structures
- Vol. 59 (1) , 6
Research on the creep characteristics and predictive modeling of all-light shale ceramsite concrete
- 5 December 2025
- Published by Springer Nature in Materials and Structures
- Vol. 59 (1) , 6
Research on the creep characteristics and predictive modeling of all-light shale ceramsite concrete
- Open Access
Study on Shear Resistance of Composite Interface of Steel Truss Ceramsite Concrete and Finite Element Simulation
This study investigates the shear behavior of steel truss ceramsite concrete composite interfaces through double-sided direct shear tests and finite element simulations. The results reveal three distinct shear response phases: elastic deformation, plastic softening, and full yielding. The interfacial shear capacity arises from synergistic contributions of bond strength, friction, and truss reinforcement action. Comparative analysis of design codes identifies Eurocode 2 as providing an optimal alignment with the experimental data. An ABAQUS-based finite element model incorporating a cohesive spring composite interface mechanism confirms the model’s reliability. The findings validate Eurocode 2 for ceramsite concrete interface design and propose single-row truss configurations as economically efficient solutions for lightweight high-strength composite structures. The research results are aimed at providing a theoretical basis for the design optimization and code revision of ceramsite concrete composite structures, and promoting the wide application of lightweight high-strength concrete in sustainable buildings.
Open AccessStudy on Shear Resistance of Composite Interface of Steel Truss Ceramsite Concrete and Finite Element Simulation
This study investigates the shear behavior of steel truss ceramsite concrete composite interfaces through double-sided direct shear tests and finite element simulations. The results reveal three distinct shear response phases: elastic deformation, plastic softening, and full yielding. The interfacial shear capacity arises from synergistic contributions of bond strength, friction, and truss reinforcement action. Comparative analysis of design codes identifies Eurocode 2 as providing an optimal alignment with the experimental data. An ABAQUS-based finite element model incorporating a cohesive spring composite interface mechanism confirms the model’s reliability. The findings validate Eurocode 2 for ceramsite concrete interface design and propose single-row truss configurations as economically efficient solutions for lightweight high-strength composite structures. The research results are aimed at providing a theoretical basis for the design optimization and code revision of ceramsite concrete composite structures, and promoting the wide application of lightweight high-strength concrete in sustainable buildings.
- Open Access
Mechanical Properties and Chloride Salt Corrosion Resistance of All-Lightweight Shale Ceramsite Concrete
In investigating the mechanical properties and chloride corrosion resistance of all-light shale ceramsite concrete (ALSCC), samples of ALSCC20–ALSCC45 with a compressive strength of C20–C45 were individually prepared. The compressive strength, split tensile strength, and elastic modulus of ALSCC were analyzed. Additionally, the chloride salt corrosion resistance of ALSCC was assessed by examining chloride ion penetration depth, steel corrosion rate, and compressive strength after ALSCC30 corrosion. Furthermore, the microstructure of ALSCC hydration products was observed using scanning electron microscopy (SEM). Results indicate that as the strength grade increases, the water–cement ratio decreases, and the internal structure becomes denser, thereby improving the mechanical and corrosion resistance properties of ALSCC. Notably, the chloride corrosion resistance of ALSCC surpasses that of ordinary concrete. SEM images reveal that the hydration of ceramsite with Ca(OH)2 in concrete generates Ca[Al(OH)4]2 precipitation and C–S–H gel, which enhances internal filling and improves chloride corrosion resistance. Furthermore, based on the results of the ALSCC30 corrosion test, a calculation model for predicting compressive strength in a chloride environment was proposed. This model effectively predicts the compressive strength of ALSCC under chloride exposure conditions.
Open AccessMechanical Properties and Chloride Salt Corrosion Resistance of All-Lightweight Shale Ceramsite Concrete
In investigating the mechanical properties and chloride corrosion resistance of all-light shale ceramsite concrete (ALSCC), samples of ALSCC20–ALSCC45 with a compressive strength of C20–C45 were individually prepared. The compressive strength, split tensile strength, and elastic modulus of ALSCC were analyzed. Additionally, the chloride salt corrosion resistance of ALSCC was assessed by examining chloride ion penetration depth, steel corrosion rate, and compressive strength after ALSCC30 corrosion. Furthermore, the microstructure of ALSCC hydration products was observed using scanning electron microscopy (SEM). Results indicate that as the strength grade increases, the water–cement ratio decreases, and the internal structure becomes denser, thereby improving the mechanical and corrosion resistance properties of ALSCC. Notably, the chloride corrosion resistance of ALSCC surpasses that of ordinary concrete. SEM images reveal that the hydration of ceramsite with Ca(OH)2 in concrete generates Ca[Al(OH)4]2 precipitation and C–S–H gel, which enhances internal filling and improves chloride corrosion resistance. Furthermore, based on the results of the ALSCC30 corrosion test, a calculation model for predicting compressive strength in a chloride environment was proposed. This model effectively predicts the compressive strength of ALSCC under chloride exposure conditions.
- 25 March 2024
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- p. 1-21
Experimental and numerical investigation of the hysteretic behavior of reinforced concrete column-steel beam interior joints under low seismic intensity levels
1. The reinforced concrete column-steel beam (RCS) composite structure, which gives full play to the advantages of its materials, is a new type of assembly with excellent structural performance. Na...
- 25 March 2024
- Published by Taylor & Francis in Structure and Infrastructure Engineering
- p. 1-21
Experimental and numerical investigation of the hysteretic behavior of reinforced concrete column-steel beam interior joints under low seismic intensity levels
1. The reinforced concrete column-steel beam (RCS) composite structure, which gives full play to the advantages of its materials, is a new type of assembly with excellent structural performance. Na...
- Open Access
Progressive Collapse Resistance Assessment of a Multi-Column Frame Tube Structure with an Assembled Truss Beam Composite Floor under Different Column Removal Conditions
To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with an assembled truss beam composite floor (ATBCF), pushdown analysis and nonlinear dynamic analysis are conducted for such a structure using the alternate load path (ALP) method. The bearing capacities of the remaining structures under three different work conditions, which are the side middle column removal, the edge middle column removal, and the corner column removal, are individually studied, and the collapse mechanism of the remaining structures is analyzed based on the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient is discussed. The results indicate that the residual bearing capacity of the remaining structure following the bottom corner column removal is higher than that of the one following the side or edge middle column removal, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times the period of the first-order vertical vibration mode of the remaining structure, and it is suitable to set the dynamic amplification coefficient as 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.
Open AccessProgressive Collapse Resistance Assessment of a Multi-Column Frame Tube Structure with an Assembled Truss Beam Composite Floor under Different Column Removal Conditions
To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with an assembled truss beam composite floor (ATBCF), pushdown analysis and nonlinear dynamic analysis are conducted for such a structure using the alternate load path (ALP) method. The bearing capacities of the remaining structures under three different work conditions, which are the side middle column removal, the edge middle column removal, and the corner column removal, are individually studied, and the collapse mechanism of the remaining structures is analyzed based on the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient is discussed. The results indicate that the residual bearing capacity of the remaining structure following the bottom corner column removal is higher than that of the one following the side or edge middle column removal, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times the period of the first-order vertical vibration mode of the remaining structure, and it is suitable to set the dynamic amplification coefficient as 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.
- Open Access
- 27 November 2023
- Published by MDPI AG in Preprints.org
Progressive Collapse Resistance Assessment of Multi-Column Frame Tube Structure with Assembled Truss Beam Composite Floor under Different Column Demolition Conditions
To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with the assembled truss beam composite floor (ATBCF), the pushdown analysis, and the nonlinear dynamic analysis as well, are conducted for such a structure by using the alternate load path (ALP) method. The bearing capacities of the remaining structures at three different work conditions, which are the side middle column failure, the edge middle column failure, and the corner column failure, are individually studied, and the collapse mechanism for the remaining structures is analyzed from the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient are discussed. The results show that the residual bearing capacity of the remaining structure with the bottom corner column failure is higher than that of the one with the side or edge middle column failure, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times of the first-order vertical vibration period of the remaining structure, and it is suitable to set the dynamic amplification coefficient as of 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.
- 27 November 2023
- Published by MDPI AG in Preprints.org
Open AccessProgressive Collapse Resistance Assessment of Multi-Column Frame Tube Structure with Assembled Truss Beam Composite Floor under Different Column Demolition Conditions
To estimate the progressive collapse resistance capacity of a multi-column frame tube structure with the assembled truss beam composite floor (ATBCF), the pushdown analysis, and the nonlinear dynamic analysis as well, are conducted for such a structure by using the alternate load path (ALP) method. The bearing capacities of the remaining structures at three different work conditions, which are the side middle column failure, the edge middle column failure, and the corner column failure, are individually studied, and the collapse mechanism for the remaining structures is analyzed from the aspects of the internal force redistribution and the failure mode of the second defense line. Simultaneously, the influence of the column failure time on the dynamic response of the remaining structure and the dynamic amplification coefficient are discussed. The results show that the residual bearing capacity of the remaining structure with the bottom corner column failure is higher than that of the one with the side or edge middle column failure, while the latter has a stronger plastic deformation capacity. When the ALP method is adopted to operate the progressive collapse analysis, it is reasonable to take the column failure time as 0.1 times of the first-order vertical vibration period of the remaining structure, and it is suitable to set the dynamic amplification coefficient as of 2.0, which is the ratio of the maximum dynamic displacement to the static displacement of the remaining structure under the transient loading condition.
- Open Access
- 18 April 2021
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 21 (3) , 954-972
Experimental and numerical study on the in-plane behaviour of a new long-span assembly composite floor system under lateral load
A new long-span assembly composite floor system for use in multi-column frame-tube structure is presented. The basic assembly unit consists of steel truss keel and profile sheet concrete composite slab, which of the two parts are combined together through shear stud. By means of standardized assembly connection structure, such a new floor system can realize a rapid assembly of floor and support frame. Based on test research of 1/3 scale model, the paper discusses the in-plane mechanical performance of the new floor system. Through loading at the direction of parallel to the assembly slab seam and perpendicular to the assembly slab seam, respectively, the influence of assembly orientation of floor units on the failure modes, distribution and transmission performance of the horizontal loads, and the in-plane stiffness were identified in detail. A numerical model was developed with its input parameters calibrated from full-scale experimental tests. Based on model analysis, the influence of thickness of concrete slab on the in-plane stiffness was discussed.
- 18 April 2021
- Published by Taylor & Francis in Journal of Asian Architecture and Building Engineering
- Vol. 21 (3) , 954-972
Open AccessExperimental and numerical study on the in-plane behaviour of a new long-span assembly composite floor system under lateral load
A new long-span assembly composite floor system for use in multi-column frame-tube structure is presented. The basic assembly unit consists of steel truss keel and profile sheet concrete composite slab, which of the two parts are combined together through shear stud. By means of standardized assembly connection structure, such a new floor system can realize a rapid assembly of floor and support frame. Based on test research of 1/3 scale model, the paper discusses the in-plane mechanical performance of the new floor system. Through loading at the direction of parallel to the assembly slab seam and perpendicular to the assembly slab seam, respectively, the influence of assembly orientation of floor units on the failure modes, distribution and transmission performance of the horizontal loads, and the in-plane stiffness were identified in detail. A numerical model was developed with its input parameters calibrated from full-scale experimental tests. Based on model analysis, the influence of thickness of concrete slab on the in-plane stiffness was discussed.
- Open Access
- 1 August 2020
- Published by International Hellenic University in Journal of Engineering Science and Technology Review
- Vol. 13 (4) , 198-205
Rebar Truss Stiffened Concrete Composite Beams with U-Shaped Steel Girders under Bending Moments
- 1 August 2020
- Published by International Hellenic University in Journal of Engineering Science and Technology Review
- Vol. 13 (4) , 198-205
Open AccessRebar Truss Stiffened Concrete Composite Beams with U-Shaped Steel Girders under Bending Moments
- Open Access
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Experimental Study on Bolt‐Spliced Prefabricated Steel Frame Beams
The prefabricated steel structural residence is characterized by modularization and standardization, which meets the requirement of industrial development. The steel frame beam needs to be fabricated in segments and assembled in site due to the limitation of transportation. In practical engineering, the steel frame beams need to be spliced along the beam span. A robust connection between the two steel beam segments is necessary as it will influence the load bearing capacity, stiffness, and stability of the steel frame. In total, 12 specimens were tested to investigate the influence of spliced types, loading patterns, and bolt types on the performance of the steel frame. The observed failure modes, load versus displacement curves, and moment versus rotation angle curves are presented. The test results show that the strength and deformability of bolt‐spliced connections are generally good and similar to those of the prototype beam.
- 1 January 2020
- Published by Wiley in Advances in Civil Engineering
- Vol. 2020 (1)
Open AccessExperimental Study on Bolt‐Spliced Prefabricated Steel Frame Beams
The prefabricated steel structural residence is characterized by modularization and standardization, which meets the requirement of industrial development. The steel frame beam needs to be fabricated in segments and assembled in site due to the limitation of transportation. In practical engineering, the steel frame beams need to be spliced along the beam span. A robust connection between the two steel beam segments is necessary as it will influence the load bearing capacity, stiffness, and stability of the steel frame. In total, 12 specimens were tested to investigate the influence of spliced types, loading patterns, and bolt types on the performance of the steel frame. The observed failure modes, load versus displacement curves, and moment versus rotation angle curves are presented. The test results show that the strength and deformability of bolt‐spliced connections are generally good and similar to those of the prototype beam.
- Open Access
- 10 April 2015
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 9 (1) , 82-89
The Collapse Accident Analysis for Steel Structure of Waste-heat Boiler in a Cement Plant
The Collapse Accident Analysis for Steel Structure of Waste-heat Boiler in a Cement Plant
- 10 April 2015
- Published by Bentham Science Publishers Ltd. in The Open Civil Engineering Journal
- Vol. 9 (1) , 82-89
Open AccessThe Collapse Accident Analysis for Steel Structure of Waste-heat Boiler in a Cement Plant
The Collapse Accident Analysis for Steel Structure of Waste-heat Boiler in a Cement Plant