Yanjie Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yanjie Zheng has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Shaohuang Weng
Department of Pharmaceutical Analysis, School of Pharmacy, Fujian Medical University, Fuzhou, 350122, China
5 shared publications Xinhua Lin
Department of Pharmaceutical Analysis, School of Pharmacy, Fujian Medical University, Fuzhou 350122, China
4 shared publicationsFei Lin
Department of Pharmaceutical Analysis, School of Pharmacy, Fujian Medical University, Fuzhou 350122, China
3 shared publications- Li Chen
Department of Pharmaceutical Analysis, School of Pharmacy, Fujian Medical University, Fuzhou 350122, China
2 shared publications - Xinyang Yin
Department of Chemical Engineering, The Pennsylvania State University, University Park, USA
2 shared publications - Yichun Xu
Hubei Province Engineering Technology Research Center for Construction Quality Testing Equipments
2 shared publications
Latest Publications
- 9 March 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (7)
Ultrasensitive Electrochemical Detection of Myo‑Inositol in Gestational Diabetes Mellitus Urine Using Poly-Eriochrome Black T Modified Glassy Carbon Electrode
A novel and sensitive electrochemical method was developed for the determination of myo-inositol (MI), a key biomarker associated with gestational diabetes mellitus (GDM). The sensor was fabricated by electropolymerizing eriochrome black T (EBT) on a glassy carbon electrode (GCE). The surface morphology and interfacial properties of the resulting poly-EBT film were characterized by scanning electron microscopy and electrochemical impedance spectroscopy, respectively. The electrochemical behavior of MI at the modified electrode was investigated by cyclic voltammetry, and its quantification was carried out using differential pulse voltammetry. The reduction peak current of the poly-EBT film decreased systematically with increasing MI concentration, exhibiting a good linear relationship in the range from 0.4 to 8.8 nM and a limit of detection at 0.15 nM. Compared with the bare GCE, the poly-EBT modified electrode showed excellent selectivity and achieved satisfactory recovery rates (96.0%–102.9%) in spiked urine samples. This proposed method was successfully applied to the analysis of urine samples from patients with GDM, and the MI levels were found to be significantly higher than those in the healthy control group. These results show that this electrochemical strategy can sensitively monitor MI in human urine and help assess metabolic changes related to GDM.
- 9 March 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (7)
Ultrasensitive Electrochemical Detection of Myo‑Inositol in Gestational Diabetes Mellitus Urine Using Poly-Eriochrome Black T Modified Glassy Carbon Electrode
A novel and sensitive electrochemical method was developed for the determination of myo-inositol (MI), a key biomarker associated with gestational diabetes mellitus (GDM). The sensor was fabricated by electropolymerizing eriochrome black T (EBT) on a glassy carbon electrode (GCE). The surface morphology and interfacial properties of the resulting poly-EBT film were characterized by scanning electron microscopy and electrochemical impedance spectroscopy, respectively. The electrochemical behavior of MI at the modified electrode was investigated by cyclic voltammetry, and its quantification was carried out using differential pulse voltammetry. The reduction peak current of the poly-EBT film decreased systematically with increasing MI concentration, exhibiting a good linear relationship in the range from 0.4 to 8.8 nM and a limit of detection at 0.15 nM. Compared with the bare GCE, the poly-EBT modified electrode showed excellent selectivity and achieved satisfactory recovery rates (96.0%–102.9%) in spiked urine samples. This proposed method was successfully applied to the analysis of urine samples from patients with GDM, and the MI levels were found to be significantly higher than those in the healthy control group. These results show that this electrochemical strategy can sensitively monitor MI in human urine and help assess metabolic changes related to GDM.
- 1 June 2021
- Published by Elsevier in Microchemical Journal
- Vol. 165, 106091
Dual-mode biosensor for femtomolar miRNA-155 detection by electrochemiluminescence and adsorptive stripping voltammetry
- 1 June 2021
- Published by Elsevier in Microchemical Journal
- Vol. 165, 106091
Dual-mode biosensor for femtomolar miRNA-155 detection by electrochemiluminescence and adsorptive stripping voltammetry
- 1 March 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1148, 338201
Integration of fluorescent polydopamine nanoparticles on protamine for simple and sensitive trypsin assay
- 1 March 2021
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1148, 338201
Integration of fluorescent polydopamine nanoparticles on protamine for simple and sensitive trypsin assay
- 20 November 2020
- Published by Springer Nature in Analytical Sciences
- Vol. 37 (8) , 1073-1079
Rapid Determination of 7-Hydroxycoumarin Using a Nanogold/ Poly-thionine Modified Glass Carbon Electrode
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 20 November 2020
- Published by Springer Nature in Analytical Sciences
- Vol. 37 (8) , 1073-1079
Rapid Determination of 7-Hydroxycoumarin Using a Nanogold/ Poly-thionine Modified Glass Carbon Electrode
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies
- 11 November 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (16) , 167502
Dual-Modal Biosensor for the Determination of Femtomolar miRNA-126 Based on Electrochemical Impedance Spectroscopy and Electrochemiluminescence with Hybridization Chain Reaction Amplification
In this study, a novel dual-modal electrochemical impedance spectroscopy (EIS) and electrochemiluminescence (ECL) biosensor for sensitive detection of femtomolar miRNA-126 was developed based on hybridization chain reaction (HCR). The capture unit was Fe 3 O 4 @SiO 2 @AuNPs-cDNA, being Fe 3 O 4 @SiO 2 @AuNPs nanoparticles coated by hairpin cDNA which could capture miRNA-126 specifically. The signal unit was HCR-Ru(phen) 3 2+ , which was a long double-stranded DNA obtained through HCR with a great number of ECL signal labels Ru(phen) 3 2+ embedded. In presence of target miRNA-126, stem-loop structure of cDNA in the capture unit was opened and a partial dsDNA was formed, the residue bases of which hybridized with the signal unit to form a capture unit/miRNA-126/signal unit complex on the electrode surface. In this case, dual-modal biosensor was prepared easily by the help of magnet, and EIS and ECL detection was both acquired. In addition, a miRNA-126 molecule corresponded to a long double-stranded DNA and a large amount of Ru(phen) 3 2+ ions embedded, so the electrochemical impedance and the ECL intensity were greatly increased, with a limit of detection (LOD) of 2 fM. And, EIS and ECL results could be checked mutually, improving the detection accuracy and reliability. It offers a simple, fast, sensitive, selective and accurate approach for versatile analysis of microRNAs.
- 11 November 2020
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 167 (16) , 167502
Dual-Modal Biosensor for the Determination of Femtomolar miRNA-126 Based on Electrochemical Impedance Spectroscopy and Electrochemiluminescence with Hybridization Chain Reaction Amplification
In this study, a novel dual-modal electrochemical impedance spectroscopy (EIS) and electrochemiluminescence (ECL) biosensor for sensitive detection of femtomolar miRNA-126 was developed based on hybridization chain reaction (HCR). The capture unit was Fe 3 O 4 @SiO 2 @AuNPs-cDNA, being Fe 3 O 4 @SiO 2 @AuNPs nanoparticles coated by hairpin cDNA which could capture miRNA-126 specifically. The signal unit was HCR-Ru(phen) 3 2+ , which was a long double-stranded DNA obtained through HCR with a great number of ECL signal labels Ru(phen) 3 2+ embedded. In presence of target miRNA-126, stem-loop structure of cDNA in the capture unit was opened and a partial dsDNA was formed, the residue bases of which hybridized with the signal unit to form a capture unit/miRNA-126/signal unit complex on the electrode surface. In this case, dual-modal biosensor was prepared easily by the help of magnet, and EIS and ECL detection was both acquired. In addition, a miRNA-126 molecule corresponded to a long double-stranded DNA and a large amount of Ru(phen) 3 2+ ions embedded, so the electrochemical impedance and the ECL intensity were greatly increased, with a limit of detection (LOD) of 2 fM. And, EIS and ECL results could be checked mutually, improving the detection accuracy and reliability. It offers a simple, fast, sensitive, selective and accurate approach for versatile analysis of microRNAs.
- 9 February 2017
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 38 (3) , 378-383
In Situ Growth of Plasmonic Gold Nanoparticles for the Direct and Sensitive Colorimetric Assay of Glucose
Gold nanoparticles (Au NPs)‐based colorimetric assay for the highly sensitive and selective detection of glucose has been conducted. The sensing, which was based on the in situ growth of Au NPs in the presence of glucose, was developed with the solution changing from colorless to red. This change could be observed with the naked eye or a ultraviolet–visible (UV–vis) spectrophotometer. Moreover, adding trace amounts of Tween‐20 kept Au NPs well spaced. Under the optimal assay conditions, the absorbance of Au NPs at 550 nm was proportional to glucose concentration within 400–1800 μM with a linear regression equation, and the detection limit was 6.28 μM. Some common interfering compounds in beverages, including other sugars, food additives, and amino acids, did not affect glucose sensing. Therefore, the proposed Au NP‐based colorimetric assay could be successfully used to determine glucose in beverages.
- 9 February 2017
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 38 (3) , 378-383
In Situ Growth of Plasmonic Gold Nanoparticles for the Direct and Sensitive Colorimetric Assay of Glucose
Gold nanoparticles (Au NPs)‐based colorimetric assay for the highly sensitive and selective detection of glucose has been conducted. The sensing, which was based on the in situ growth of Au NPs in the presence of glucose, was developed with the solution changing from colorless to red. This change could be observed with the naked eye or a ultraviolet–visible (UV–vis) spectrophotometer. Moreover, adding trace amounts of Tween‐20 kept Au NPs well spaced. Under the optimal assay conditions, the absorbance of Au NPs at 550 nm was proportional to glucose concentration within 400–1800 μM with a linear regression equation, and the detection limit was 6.28 μM. Some common interfering compounds in beverages, including other sugars, food additives, and amino acids, did not affect glucose sensing. Therefore, the proposed Au NP‐based colorimetric assay could be successfully used to determine glucose in beverages.