Priscilla Machado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Priscilla Machado has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Flemming Forsberg
Department of Radiology, Thomas Jefferson University, Philadelphia, PA, 19107, USA
9 shared publications - John R. Eisenbrey
Department of Radiology, Thomas Jefferson University, Philadelphia, PA 19107, USA
5 shared publications - Corinne E. Wessner
Department of Radiology, Thomas Jefferson University, Philadelphia, PA 19107, USA
4 shared publications Flemming Forsberg
Department of Radiology Thomas Jefferson University Philadelphia Pennsylvania USA
4 shared publications- Kirk Wallace
GE Global Research,Niskayuna,NY,USA,12309
3 shared publications Alexander Sevrukov
Department of Radiology, Thomas Jefferson University, 763H Main Building, 132 South 10th Street, Philadelphia, PA 19107
2 shared publications
Latest Publications
- Open Access
- 23 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (6) , 948
Assessment of Early Breast Cancer Response to Chemotherapy with Ultrasound Radiomics
Objective: This prospective study investigated the use of H-scan ultrasound (US) imaging as a novel component of a multiparametric radiomic analysis framework for characterizing human breast cancer response to neoadjuvant chemotherapy (NAC) before and early after treatment initiation. Methods: Thirty breast cancer patients scheduled for NAC were scanned using a clinical US system (Logiq E9, GE HealthCare) equipped with a 9L-D linear array transducer. Radiofrequency (RF) data was obtained at baseline (pre-NAC) and after 10% and 30% of the complete dose of chemotherapy. The RF data was analyzed by a bank of 256 frequency-shifted bandpass filters to form H-scan US frequency images. Grayscale texture features were extracted from both B-scan and H-scan US images. In addition, US attenuation coefficient and speckle statistics based on the Nakagami and Burr distributions were estimated from the RF data. Data classification of tumor and peri-tumoral regions was performed using a novel three-dimensional (3D) score map based on support vector machine (SVM) modeling. Unlike conventional classifiers that report only a single prediction score, a 3D score map provides a visual representation of the classifier decision space, enabling interpretation of class separation and treatment-induced shifts in multiparametric US measurements. Results: The dataset was split into 10 disjoint partitions (90% training, 10% testing) to compute area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy measures. Actual patient response to NAC was assessed at surgery and categorized as either pathologic complete response (pCR) or non-pCR. Multiparametric US and data classification results at pre-NAC found AUC values of 0.78 after using only tumor information (p < 0.01), which increased to 0.81 with inclusion of peri-tumoral information (p < 0.01). Significant differences in multiparametric US measures from both cancer response types was found after integration of patient data collected at 10% completion of the NAC regimen (i.e., first NAC cycle), yielding an improved AUC of 0.86 (p < 0.001). Conclusions: Multiparametric US imaging with radiomic features from both the tumor and peri-tumoral regions is a promising noninvasive approach for monitoring early breast cancer response to NAC.
- 23 March 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (6) , 948
Open AccessAssessment of Early Breast Cancer Response to Chemotherapy with Ultrasound Radiomics
Objective: This prospective study investigated the use of H-scan ultrasound (US) imaging as a novel component of a multiparametric radiomic analysis framework for characterizing human breast cancer response to neoadjuvant chemotherapy (NAC) before and early after treatment initiation. Methods: Thirty breast cancer patients scheduled for NAC were scanned using a clinical US system (Logiq E9, GE HealthCare) equipped with a 9L-D linear array transducer. Radiofrequency (RF) data was obtained at baseline (pre-NAC) and after 10% and 30% of the complete dose of chemotherapy. The RF data was analyzed by a bank of 256 frequency-shifted bandpass filters to form H-scan US frequency images. Grayscale texture features were extracted from both B-scan and H-scan US images. In addition, US attenuation coefficient and speckle statistics based on the Nakagami and Burr distributions were estimated from the RF data. Data classification of tumor and peri-tumoral regions was performed using a novel three-dimensional (3D) score map based on support vector machine (SVM) modeling. Unlike conventional classifiers that report only a single prediction score, a 3D score map provides a visual representation of the classifier decision space, enabling interpretation of class separation and treatment-induced shifts in multiparametric US measurements. Results: The dataset was split into 10 disjoint partitions (90% training, 10% testing) to compute area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and accuracy measures. Actual patient response to NAC was assessed at surgery and categorized as either pathologic complete response (pCR) or non-pCR. Multiparametric US and data classification results at pre-NAC found AUC values of 0.78 after using only tumor information (p < 0.01), which increased to 0.81 with inclusion of peri-tumoral information (p < 0.01). Significant differences in multiparametric US measures from both cancer response types was found after integration of patient data collected at 10% completion of the NAC regimen (i.e., first NAC cycle), yielding an improved AUC of 0.86 (p < 0.001). Conclusions: Multiparametric US imaging with radiomic features from both the tumor and peri-tumoral regions is a promising noninvasive approach for monitoring early breast cancer response to NAC.
- Open Access
- 9 June 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 53 (9) , 2159-2164
Initial Evaluation of Lymphosonography to Identify Sentinel Lymph Nodes in Cervical and Vulvar Cancer Patients
The objective of this pilot study was to identify sentinel lymph nodes (SLN) in cervical or vulvar cancer subjects scheduled for surgery using lymphosonography, comparing the findings with pathology. The contrast agent Sonazoid was administered subcutaneously around the tumor, and real‐time contrast‐enhanced ultrasound was performed to identify SLNs. Eleven SLNs were surgically excised, while lymphosonography identified 17 SLNs in 5 subjects. Comparing surgically excised SLNs and those identified by lymphosonography showed that 10 out of 11 SLNs (or 91%) were identified by lymphosonography. Lymphosonography identified all the benign SLNs and 2 out of the 3 malignant SLNs.
- 9 June 2025
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 53 (9) , 2159-2164
Open AccessInitial Evaluation of Lymphosonography to Identify Sentinel Lymph Nodes in Cervical and Vulvar Cancer Patients
The objective of this pilot study was to identify sentinel lymph nodes (SLN) in cervical or vulvar cancer subjects scheduled for surgery using lymphosonography, comparing the findings with pathology. The contrast agent Sonazoid was administered subcutaneously around the tumor, and real‐time contrast‐enhanced ultrasound was performed to identify SLNs. Eleven SLNs were surgically excised, while lymphosonography identified 17 SLNs in 5 subjects. Comparing surgically excised SLNs and those identified by lymphosonography showed that 10 out of 11 SLNs (or 91%) were identified by lymphosonography. Lymphosonography identified all the benign SLNs and 2 out of the 3 malignant SLNs.
- Open Access
- 22 January 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 44 (5) , 927-933
Evaluating Bone Fracture Healing in a Rabbit Model Using Doppler Imaging Modes, Shear Wave Elastography, X‐Ray, and Dual‐Energy X‐Ray Absorptiometry
Objective: This study investigated methods of evaluating the bone fracture healing process using superb microvascular imaging (SMI; two modes color SMI [cSMI] and monochromeSMI [mSMI]), and shear wave elastography (SWE), relative to X‐ray, dual‐energy X‐ray absorptiometry (DXA), and platelet endothelial cell adhesion molecule 1 (PECAM‐1) also know as cluster of differentiation 31 (CD‐31) staining in a rabbit model.Methods: This IACUC‐approved study involved eight rabbits that underwent a bilateral fibula osteotomy and were followed for 7 or 21 days (Groups 1 and 2 with 4 rabbits in each). Ultrasound examinations using cSMI, mSMI, and SWE were performed on Days 0, 4, 7, 14, and 21 post‐surgery. At the final time point, rabbits had X‐ray imaging followed by euthanasia and DXA scan. Finally, the fracture areas underwent decalcification, and specimens were stained with CD‐31 for pathological analysis. Ultrasound and X‐ray findings were compared using ANOVAs or paired t‐tests with CD‐31 stains and DXA was used as a reference.Results: Comparing SMI ultrasound images between the last time points for Group 1 (Day 7) and Group 2 (Day 21) showed no statistical significance difference for cSMI (P = .14) and mSMI (P = .06), similarly when compared with CD‐31 stains there was no statistical significance difference for cSMI in Group 2 (P = .13). The SWE ultrasound images from the last time points in Groups 1 and showed no statistical significance difference (P = .33), the same results were then compared with DXA and also showed no statistical significance difference (P = .14). When comparing results of the X‐ray images from the last time points for Groups 1 and 2 a statistical significance difference was found (P = .01), and when X‐ray images were compared with DXA there was a statistical significance difference (P < .001).Conclusion: Compared with CD‐31 stains cSMI on Day 21 was not statistically significant (P = .13). Results comparing SWE with DXA were also not statistically significant (P = .14). These results indicate the potential of using certain ultrasound imaging techniques to monitor the bone fracture healing process.
- 22 January 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 44 (5) , 927-933
Open AccessEvaluating Bone Fracture Healing in a Rabbit Model Using Doppler Imaging Modes, Shear Wave Elastography, X‐Ray, and Dual‐Energy X‐Ray Absorptiometry
Objective: This study investigated methods of evaluating the bone fracture healing process using superb microvascular imaging (SMI; two modes color SMI [cSMI] and monochromeSMI [mSMI]), and shear wave elastography (SWE), relative to X‐ray, dual‐energy X‐ray absorptiometry (DXA), and platelet endothelial cell adhesion molecule 1 (PECAM‐1) also know as cluster of differentiation 31 (CD‐31) staining in a rabbit model.Methods: This IACUC‐approved study involved eight rabbits that underwent a bilateral fibula osteotomy and were followed for 7 or 21 days (Groups 1 and 2 with 4 rabbits in each). Ultrasound examinations using cSMI, mSMI, and SWE were performed on Days 0, 4, 7, 14, and 21 post‐surgery. At the final time point, rabbits had X‐ray imaging followed by euthanasia and DXA scan. Finally, the fracture areas underwent decalcification, and specimens were stained with CD‐31 for pathological analysis. Ultrasound and X‐ray findings were compared using ANOVAs or paired t‐tests with CD‐31 stains and DXA was used as a reference.Results: Comparing SMI ultrasound images between the last time points for Group 1 (Day 7) and Group 2 (Day 21) showed no statistical significance difference for cSMI (P = .14) and mSMI (P = .06), similarly when compared with CD‐31 stains there was no statistical significance difference for cSMI in Group 2 (P = .13). The SWE ultrasound images from the last time points in Groups 1 and showed no statistical significance difference (P = .33), the same results were then compared with DXA and also showed no statistical significance difference (P = .14). When comparing results of the X‐ray images from the last time points for Groups 1 and 2 a statistical significance difference was found (P = .01), and when X‐ray images were compared with DXA there was a statistical significance difference (P < .001).Conclusion: Compared with CD‐31 stains cSMI on Day 21 was not statistically significant (P = .13). Results comparing SWE with DXA were also not statistically significant (P = .14). These results indicate the potential of using certain ultrasound imaging techniques to monitor the bone fracture healing process.
- 3 July 2024
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 40 (3)
Characterizing Sentinel Lymph Node Status in Breast Cancer Patients Using a Deep-Learning Model Compared With Radiologists' Analysis of Grayscale Ultrasound and Lymphosonography
The objective of the study was to use a deep learning model to differentiate between benign and malignant sentinel lymph nodes (SLNs) in patients with breast cancer compared to radiologists' assessments. Seventy-nine women with breast cancer were enrolled and underwent lymphosonography and contrast-enhanced ultrasound (CEUS) examination after subcutaneous injection of ultrasound contrast agent around their tumor to identify SLNs. Google AutoML was used to develop image classification model. Grayscale and CEUS images acquired during the ultrasound examination were uploaded with a data distribution of 80% for training/20% for testing. The performance metric used was area under precision/recall curve (AuPRC). In addition, 3 radiologists assessed SLNs as normal or abnormal based on a clinical established classification. Two-hundred seventeen SLNs were divided in 2 for model development; model 1 included all SLNs and model 2 had an equal number of benign and malignant SLNs. Validation results model 1 AuPRC 0.84 (grayscale)/0.91 (CEUS) and model 2 AuPRC 0.91 (grayscale)/0.87 (CEUS). The comparison between artificial intelligence (AI) and readers' showed statistical significant differences between all models and ultrasound modes; model 1 grayscale AI versus readers, P = 0.047, and model 1 CEUS AI versus readers, P < 0.001. Model 2 r grayscale AI versus readers, P = 0.032, and model 2 CEUS AI versus readers, P = 0.041. The interreader agreement overall result showed κ values of 0.20 for grayscale and 0.17 for CEUS. In conclusion, AutoML showed improved diagnostic performance in balance volume datasets. Radiologist performance was not influenced by the dataset’s distribution.
- 3 July 2024
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 40 (3)
Characterizing Sentinel Lymph Node Status in Breast Cancer Patients Using a Deep-Learning Model Compared With Radiologists' Analysis of Grayscale Ultrasound and Lymphosonography
The objective of the study was to use a deep learning model to differentiate between benign and malignant sentinel lymph nodes (SLNs) in patients with breast cancer compared to radiologists' assessments. Seventy-nine women with breast cancer were enrolled and underwent lymphosonography and contrast-enhanced ultrasound (CEUS) examination after subcutaneous injection of ultrasound contrast agent around their tumor to identify SLNs. Google AutoML was used to develop image classification model. Grayscale and CEUS images acquired during the ultrasound examination were uploaded with a data distribution of 80% for training/20% for testing. The performance metric used was area under precision/recall curve (AuPRC). In addition, 3 radiologists assessed SLNs as normal or abnormal based on a clinical established classification. Two-hundred seventeen SLNs were divided in 2 for model development; model 1 included all SLNs and model 2 had an equal number of benign and malignant SLNs. Validation results model 1 AuPRC 0.84 (grayscale)/0.91 (CEUS) and model 2 AuPRC 0.91 (grayscale)/0.87 (CEUS). The comparison between artificial intelligence (AI) and readers' showed statistical significant differences between all models and ultrasound modes; model 1 grayscale AI versus readers, P = 0.047, and model 1 CEUS AI versus readers, P < 0.001. Model 2 r grayscale AI versus readers, P = 0.032, and model 2 CEUS AI versus readers, P = 0.041. The interreader agreement overall result showed κ values of 0.20 for grayscale and 0.17 for CEUS. In conclusion, AutoML showed improved diagnostic performance in balance volume datasets. Radiologist performance was not influenced by the dataset’s distribution.
- 1 February 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 6 (1) , e230153
Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles
Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.
- 1 February 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 6 (1) , e230153
Evaluation of Intracardiac Pressures Using Subharmonic-aided Pressure Estimation with Sonazoid Microbubbles
Purpose To investigate if the right ventricular (RV) systolic and left ventricular (LV) diastolic pressures can be obtained noninvasively using the subharmonic-aided pressure estimation (SHAPE) technique with Sonazoid microbubbles. Materials and Methods Individuals scheduled for a left and/or right heart catheterization were prospectively enrolled in this institutional review board-approved clinical trial from 2017 to 2020. A standard-of-care catheterization procedure was performed by advancing fluid-filled pressure catheters into the LV and aorta (n = 25) or RV (n = 22), and solid-state high-fidelity pressure catheters into the LV and aorta in a subset of participants (n = 18). Study participants received an infusion of Sonazoid microbubbles (GE HealthCare), and SHAPE data were acquired using a validated interface developed on a SonixTablet (BK Medical) US scanner, synchronously with the pressure catheter data. A conversion factor, derived using cuff-based pressure measurements with a SphygmoCor XCEL PWA (ATCOR) and subharmonic signal from the aorta, was used to convert the subharmonic signal into pressure values. Errors between the pressure measurements obtained using the SHAPE technique and pressure catheter were compared. Results The mean errors in pressure measurements obtained with the SHAPE technique relative to those of the fluid-filled pressure catheter were 1.6 mm Hg ± 1.5 [SD] (P = .85), 8.4 mm Hg ± 6.2 (P = .04), and 7.4 mm Hg ± 5.7 (P = .09) for RV systolic, LV minimum diastolic, and LV end-diastolic pressures, respectively. Relative to the measurements with the solid-state high-fidelity pressure catheter, the mean errors in LV minimum diastolic and LV end-diastolic pressures were 7.2 mm Hg ± 4.5 and 6.8 mm Hg ± 3.3 (P ≥ .44), respectively. Conclusion These results indicate that SHAPE with Sonazoid may have the potential to provide clinically relevant RV systolic and LV diastolic pressures. Keywords: Ultrasound-Contrast, Cardiac, Aorta, Left Ventricle, Right Ventricle ClinicalTrials.gov registration no.: NCT03245255 © RSNA, 2024.
- 19 December 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (3) , 394-398
Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
- 19 December 2023
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (3) , 394-398
Evaluation of Uterine Fibroid Vascularity Using Contrast-Enhanced Ultrasound in Comparison with Contrast-Enhanced Magnetic Resonance Imaging
- Open Access
- 1 July 2023
- Published by Wolters Kluwer Health in Endoscopic Ultrasound
- Vol. 12 (4) , 362-368
Identification of sentinel lymph nodes in esophageal cancer patients using contrast-enhanced EUS with peritumoral injections
Objectives: The objective of this pilot study was to compare the performance of contrast-enhanced EUS (CE-EUS)–guided fine-needle aspiration (FNA) with EUS-FNA for lymph node (LN) staging in esophageal cancer. Methods: Thirty-seven subjects with esophageal cancer undergoing EUS staging were enrolled, and 30 completed this institutional review board–approved study. A Prosound F75 US system (Hitachi Medical Systems, Tokyo, Japan) with harmonic contrast imaging software and GF-UCT180 curvilinear endoscope (Olympus, Tokyo, Japan) was utilized. All LNs identified by standard EUS were first noted. Sonazoid (dose: 1 mL; GE Healthcare, Oslo, Norway) was administered peritumorally, and all enhanced LNs were recorded. Fine-needle aspiration was performed on LNs considered suspicious by EUS alone, as well as LNs enhanced on CE-EUS. Performance of each modality was compared using FNA cytology as reference standard. Results: A total of 132 LNs were detected with EUS, of which 59 showed enhancement on CE-EUS. Fifty-three LNs underwent FNA, and 22 LNs were determined to be malignant. Among the latter, 10 were considered suspicious by EUS, whereas the other 12 LNs underwent FNA only because of CE-EUS enhancement. Contrast-enhanced EUS showed enhancement in 19 of the 22 malignant LNs. The rate of metastatic node identification from EUS was 45% (10/22), and it was 86% (19/22; P = 0.008) for CE-EUS. Eight subjects (8/30 [27% of study total]) had nodal status upgraded by the addition of CE-EUS, which influenced LN staging and clinical management. Conclusions: Fine-needle aspiration of LNs identified by CE-EUS may increase metastasis positive rate by ruling out LNs not associated with the tumor drainage pattern. In addition, CE-EUS seems to identify more metastatic LNs that would not be biopsied under the standard EUS criteria.
- 1 July 2023
- Published by Wolters Kluwer Health in Endoscopic Ultrasound
- Vol. 12 (4) , 362-368
Open AccessIdentification of sentinel lymph nodes in esophageal cancer patients using contrast-enhanced EUS with peritumoral injections
Objectives: The objective of this pilot study was to compare the performance of contrast-enhanced EUS (CE-EUS)–guided fine-needle aspiration (FNA) with EUS-FNA for lymph node (LN) staging in esophageal cancer. Methods: Thirty-seven subjects with esophageal cancer undergoing EUS staging were enrolled, and 30 completed this institutional review board–approved study. A Prosound F75 US system (Hitachi Medical Systems, Tokyo, Japan) with harmonic contrast imaging software and GF-UCT180 curvilinear endoscope (Olympus, Tokyo, Japan) was utilized. All LNs identified by standard EUS were first noted. Sonazoid (dose: 1 mL; GE Healthcare, Oslo, Norway) was administered peritumorally, and all enhanced LNs were recorded. Fine-needle aspiration was performed on LNs considered suspicious by EUS alone, as well as LNs enhanced on CE-EUS. Performance of each modality was compared using FNA cytology as reference standard. Results: A total of 132 LNs were detected with EUS, of which 59 showed enhancement on CE-EUS. Fifty-three LNs underwent FNA, and 22 LNs were determined to be malignant. Among the latter, 10 were considered suspicious by EUS, whereas the other 12 LNs underwent FNA only because of CE-EUS enhancement. Contrast-enhanced EUS showed enhancement in 19 of the 22 malignant LNs. The rate of metastatic node identification from EUS was 45% (10/22), and it was 86% (19/22; P = 0.008) for CE-EUS. Eight subjects (8/30 [27% of study total]) had nodal status upgraded by the addition of CE-EUS, which influenced LN staging and clinical management. Conclusions: Fine-needle aspiration of LNs identified by CE-EUS may increase metastasis positive rate by ruling out LNs not associated with the tumor drainage pattern. In addition, CE-EUS seems to identify more metastatic LNs that would not be biopsied under the standard EUS criteria.
- 16 June 2023
- Published by Elsevier in Academic Radiology
- Vol. 30 (Suppl 2) , S211-S219
Contrast-Enhanced Ultrasound and High Sensitive Doppler for Monitoring Outcomes of Uterine Artery Embolization
- 16 June 2023
- Published by Elsevier in Academic Radiology
- Vol. 30 (Suppl 2) , S211-S219
Contrast-Enhanced Ultrasound and High Sensitive Doppler for Monitoring Outcomes of Uterine Artery Embolization
- Open Access
- 31 March 2023
- Published by XMLink in Journal of Breast Cancer
- Vol. 26 (3) , 286-291
Anatomy Versus Physiology: Is Breast Lymphatic Drainage to the Internal Thoracic (Internal Mammary) Lymphatic System Clinically Relevant?
Machado P, et al. J Breast Cancer. 2023 Mar;26:e16. https://doi.org/10.4048/jbc.2023.26.e16
- 31 March 2023
- Published by XMLink in Journal of Breast Cancer
- Vol. 26 (3) , 286-291
Open AccessAnatomy Versus Physiology: Is Breast Lymphatic Drainage to the Internal Thoracic (Internal Mammary) Lymphatic System Clinically Relevant?
Machado P, et al. J Breast Cancer. 2023 Mar;26:e16. https://doi.org/10.4048/jbc.2023.26.e16
- 9 March 2023
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 51 (3) , 452-453
Pediatric lung ultrasound imaging: Getting radiation out of the equation
- 9 March 2023
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 51 (3) , 452-453
Pediatric lung ultrasound imaging: Getting radiation out of the equation