Evandro Piccin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Evandro Piccin has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
Rodinei Augusti
Universidade Federal de Minas Gerais
3 shared publications- Hebert Vinicius Pereira
Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
2 shared publications - Karen Kenlderi de Lima Augusto
Faculty of Science and Engineering, Manchester Metropolitan University, Dalton Building, Chester Street, M1 5GD, Great Britain, UK
2 shared publications Marcelo Martins Sena
Departamento de Química, Instituto de Ciências Exatas, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
2 shared publicationsPaulo Cardoso Gomes-Junior
Departamento de Química, Universidade Federal de São Carlos, São Carlos, SP, Brazil
2 shared publicationsRenan de Oliveira Gonçalves
Departamento de Química, Universidade Federal de São Carlos, São Carlos, SP, Brazil
2 shared publications
Latest Publications
- 16 September 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (39) , 7948-7958
Green synthesis of a hydrophobic deep eutectic solvent and application as electrode modifier for electrochemical detection of diuron
This study reports, for the first time, the optimisation of the synthesis of a hydrophobic deep eutectic solvent (HDES) composed of decanoic acid and tetrabutylammonium bromide, monitored using in situ infrared spectroscopy. The results show that the preparation can be completed in less than 5 minutes at 80 °C, allowing all molecular interactions between the precursors to occur during HDES formation. This remarkably short preparation time reduces energy consumption and, consequently, aligns with the principles of green chemistry and environmental sustainability. Furthermore, the applicability of the synthesised HDES in electrochemical sensor development was assessed by modifying a carbon paste electrode with HDES, multiwalled carbon nanotubes, and mineral oil for the sensitive detection of Diuron, a widely used herbicide. Voltammetric analysis exhibited excellent reproducibility (RSD < 5 %) and efficient recovery of Diuron from tap water samples, 92 and 97 %, indicating minimal matrix effects. Moreover, the sensor demonstrated a sensitivity of 0.16 µA L·µmol−1 over a concentration ranging from 1.0 to 47.2 µmol L‒1, along with a low limit of detection (LOD) of 0.20 µmol L‒1, highlighting its potential for environmental monitoring. This study highlights the promise of HDES as an environmentally friendly alternative for electrochemical sensor fabrication, advancing the field of sustainable analytical chemistry. In addition, it confirms the viability of employing simple and green materials in sensor design, thereby strengthening the alignment of this work with the core principles of green chemistry.
- 16 September 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 17 (39) , 7948-7958
Green synthesis of a hydrophobic deep eutectic solvent and application as electrode modifier for electrochemical detection of diuron
This study reports, for the first time, the optimisation of the synthesis of a hydrophobic deep eutectic solvent (HDES) composed of decanoic acid and tetrabutylammonium bromide, monitored using in situ infrared spectroscopy. The results show that the preparation can be completed in less than 5 minutes at 80 °C, allowing all molecular interactions between the precursors to occur during HDES formation. This remarkably short preparation time reduces energy consumption and, consequently, aligns with the principles of green chemistry and environmental sustainability. Furthermore, the applicability of the synthesised HDES in electrochemical sensor development was assessed by modifying a carbon paste electrode with HDES, multiwalled carbon nanotubes, and mineral oil for the sensitive detection of Diuron, a widely used herbicide. Voltammetric analysis exhibited excellent reproducibility (RSD < 5 %) and efficient recovery of Diuron from tap water samples, 92 and 97 %, indicating minimal matrix effects. Moreover, the sensor demonstrated a sensitivity of 0.16 µA L·µmol−1 over a concentration ranging from 1.0 to 47.2 µmol L‒1, along with a low limit of detection (LOD) of 0.20 µmol L‒1, highlighting its potential for environmental monitoring. This study highlights the promise of HDES as an environmentally friendly alternative for electrochemical sensor fabrication, advancing the field of sustainable analytical chemistry. In addition, it confirms the viability of employing simple and green materials in sensor design, thereby strengthening the alignment of this work with the core principles of green chemistry.
- 14 February 2024
- Published by Elsevier in Food Chemistry
- Vol. 444, 138677
3D printing of electrochemical cell for voltammetric detection and photodegradation monitoring of folic acid in juice samples
- 14 February 2024
- Published by Elsevier in Food Chemistry
- Vol. 444, 138677
3D printing of electrochemical cell for voltammetric detection and photodegradation monitoring of folic acid in juice samples
- 20 October 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (45) , 6259-6265
A simple, quick and non-destructive approach for sampling drugs of abuse in tablets and blotter for qualitative analysis by paper spray mass spectrometry
This study presents the development of a simple, fast, and inexpensive approach for the direct analysis of new psychoactive substances (NPS) in seized tablets and blotter paper, with improved sample preservation and increased analytical frequency. Paper triangles were gently rubbed against the surface of the samples containing synthetic drugs and then subjected to analysis by paper spray ionization mass spectrometry (PS-MS). Seized samples containing lysergic acid diethylamide (LSD) and several other substances from the classes of amphetamines, N-benzyl-substituted phenethylamines, synthetic cathinones, and synthetic cannabinoids, were analysed. Three types of paper were tested (filter paper, blotter paper, and synthetic paper) and several combinations of spray solvents were studied for the optimization. All samples were weighed and photographed before and after sequences of analysis in order to attest to the sample preservation. The results revealed that the approach is excellent for sample preservation, with less than 5% of mass loss even after 27 consecutive analyses. Moreover, no significant signal decreases were observed in mass spectrometry (MS) even after the experiments. It was possible to unequivocally identify illicit substances from seized samples (pills and blotter paper). By overcoming the solubilization and wet extraction process used for sample preparation, the waste was restricted to a volume of only 10 μL of solvent for the PS-MS analysis. The main advantage of our approach over existing methods is the sample preparation, which is simple and quick since the samples are just rubbed against the PS paper. This brings enormous benefits in terms of analytical frequency, economy of time and low consumption of solvents. Another important point is that the sample can remain intact for further analysis, which is crucial in forensic analysis.
- 20 October 2023
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 15 (45) , 6259-6265
A simple, quick and non-destructive approach for sampling drugs of abuse in tablets and blotter for qualitative analysis by paper spray mass spectrometry
This study presents the development of a simple, fast, and inexpensive approach for the direct analysis of new psychoactive substances (NPS) in seized tablets and blotter paper, with improved sample preservation and increased analytical frequency. Paper triangles were gently rubbed against the surface of the samples containing synthetic drugs and then subjected to analysis by paper spray ionization mass spectrometry (PS-MS). Seized samples containing lysergic acid diethylamide (LSD) and several other substances from the classes of amphetamines, N-benzyl-substituted phenethylamines, synthetic cathinones, and synthetic cannabinoids, were analysed. Three types of paper were tested (filter paper, blotter paper, and synthetic paper) and several combinations of spray solvents were studied for the optimization. All samples were weighed and photographed before and after sequences of analysis in order to attest to the sample preservation. The results revealed that the approach is excellent for sample preservation, with less than 5% of mass loss even after 27 consecutive analyses. Moreover, no significant signal decreases were observed in mass spectrometry (MS) even after the experiments. It was possible to unequivocally identify illicit substances from seized samples (pills and blotter paper). By overcoming the solubilization and wet extraction process used for sample preparation, the waste was restricted to a volume of only 10 μL of solvent for the PS-MS analysis. The main advantage of our approach over existing methods is the sample preparation, which is simple and quick since the samples are just rubbed against the PS paper. This brings enormous benefits in terms of analytical frequency, economy of time and low consumption of solvents. Another important point is that the sample can remain intact for further analysis, which is crucial in forensic analysis.
- 23 November 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 1057-1064
Direct coupling of paper spray mass spectrometry and four-phase electroextraction sample preparation
The first coupling between PS-MS and electroextraction (EE). Sorption is directly performed on the PS paper, with subsequent prompt analysis. No off-line step is required.
- 23 November 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 146 (3) , 1057-1064
Direct coupling of paper spray mass spectrometry and four-phase electroextraction sample preparation
The first coupling between PS-MS and electroextraction (EE). Sorption is directly performed on the PS paper, with subsequent prompt analysis. No off-line step is required.
- 11 November 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (1) , 281-288
Reagent-Pencil and Paper Spray Mass Spectrometry: A Convenient Combination for Selective Analyses in Complex Matrixes
The recent developments on fieldable miniature mass spectrometers require efforts to produce easy-to-use and portable alternative tools to assist in point-of-care analysis. In this paper, the reagent-pencil (RP) technology, which has been used for solvent-free deposition of reagents in paper-based microfluidics, was combined with paper spray ionization mass spectrometry (PS-MS). In this approach, named RP-PS-MS, the PS triangular piece of paper was written with the reagent pencil, consisting of mixtures of graphite and bentonite (used as a support) and a reactive compound, and allowed to react with a given analyte from a sample matrix selectively. We conducted typical applications as proof-of-principles to verify the methodology’s general usefulness in detecting small organic molecules in distinct samples. Hence, various aldehydes (2-furaldehyde, valeraldehyde, and benzaldehyde) in spiked cachaça samples (an alcoholic drink produced from fermentation/distillation of sugarcane juice) were promptly detected using a reagent pencil doped with 4-aminophenol (the reactive compound). Similarly, we recognized typical ginsenosides and triacylglycerols (TAGs) in ginseng aqueous infusions and soybean oil samples, respectively, using lithium chloride as the reactive compound. The results indicate that the reagent-pencil methodology is compatible with PS-MS and provides an easy and fast way to detect target analytes in complex samples. The advantage over the usual solution-based deposition of reagents lies in the lack of preparation or carrying different specific solutions for special applications, which can simplify operation, especially in point-of-care analysis with fieldable mass spectrometers.
- 11 November 2020
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (1) , 281-288
Reagent-Pencil and Paper Spray Mass Spectrometry: A Convenient Combination for Selective Analyses in Complex Matrixes
The recent developments on fieldable miniature mass spectrometers require efforts to produce easy-to-use and portable alternative tools to assist in point-of-care analysis. In this paper, the reagent-pencil (RP) technology, which has been used for solvent-free deposition of reagents in paper-based microfluidics, was combined with paper spray ionization mass spectrometry (PS-MS). In this approach, named RP-PS-MS, the PS triangular piece of paper was written with the reagent pencil, consisting of mixtures of graphite and bentonite (used as a support) and a reactive compound, and allowed to react with a given analyte from a sample matrix selectively. We conducted typical applications as proof-of-principles to verify the methodology’s general usefulness in detecting small organic molecules in distinct samples. Hence, various aldehydes (2-furaldehyde, valeraldehyde, and benzaldehyde) in spiked cachaça samples (an alcoholic drink produced from fermentation/distillation of sugarcane juice) were promptly detected using a reagent pencil doped with 4-aminophenol (the reactive compound). Similarly, we recognized typical ginsenosides and triacylglycerols (TAGs) in ginseng aqueous infusions and soybean oil samples, respectively, using lithium chloride as the reactive compound. The results indicate that the reagent-pencil methodology is compatible with PS-MS and provides an easy and fast way to detect target analytes in complex samples. The advantage over the usual solution-based deposition of reagents lies in the lack of preparation or carrying different specific solutions for special applications, which can simplify operation, especially in point-of-care analysis with fieldable mass spectrometers.
- 5 May 2017
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (9) , 1965-1976
Paper Spray Mass Spectrometry for the Forensic Analysis of Black Ballpoint Pen Inks
This article describes the use of paper spray mass spectrometry (PS-MS) for the direct analysis of black ink writings made with ballpoint pens. The novel approach was developed in a forensic context by first performing the classification of commercially available ballpoint pens according to their brands. Six of the most commonly worldwide utilized brands (Bic, Paper Mate, Faber Castell, Pentel, Compactor, and Pilot) were differentiated according to their characteristic chemical patterns obtained by PS-MS. MS on the negative ion mode at a mass range of m/z 100–1000 allowed prompt discrimination just by visual inspection. On the other hand, the concept of relative ion intensity (RII) and the analysis at other mass ranges were necessary for the differentiation using the positive ion mode. PS-MS combined with partial least squares (PLS) was utilized to monitor changes on the ink chemical composition after light exposure (artificial aging studies). The PLS model was optimized by variable selection, which allowed the identification of the most influencing ions on the degradation process. The feasibility of the method on forensic investigations was also demonstrated in three different applications: (1) analysis of overlapped fresh ink lines, (2) analysis of old inks from archived documents, and (3) detection of alterations (simulated forgeries) performed on archived documents.
- 5 May 2017
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 28 (9) , 1965-1976
Paper Spray Mass Spectrometry for the Forensic Analysis of Black Ballpoint Pen Inks
This article describes the use of paper spray mass spectrometry (PS-MS) for the direct analysis of black ink writings made with ballpoint pens. The novel approach was developed in a forensic context by first performing the classification of commercially available ballpoint pens according to their brands. Six of the most commonly worldwide utilized brands (Bic, Paper Mate, Faber Castell, Pentel, Compactor, and Pilot) were differentiated according to their characteristic chemical patterns obtained by PS-MS. MS on the negative ion mode at a mass range of m/z 100–1000 allowed prompt discrimination just by visual inspection. On the other hand, the concept of relative ion intensity (RII) and the analysis at other mass ranges were necessary for the differentiation using the positive ion mode. PS-MS combined with partial least squares (PLS) was utilized to monitor changes on the ink chemical composition after light exposure (artificial aging studies). The PLS model was optimized by variable selection, which allowed the identification of the most influencing ions on the degradation process. The feasibility of the method on forensic investigations was also demonstrated in three different applications: (1) analysis of overlapped fresh ink lines, (2) analysis of old inks from archived documents, and (3) detection of alterations (simulated forgeries) performed on archived documents.
- 1 October 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 940, 104-112
Paper spray mass spectrometry and PLS-DA improved by variable selection for the forensic discrimination of beers
- 1 October 2016
- Published by Elsevier in Analytica Chimica Acta
- Vol. 940, 104-112
Paper spray mass spectrometry and PLS-DA improved by variable selection for the forensic discrimination of beers