NTNobuyuki Tanaka

Nobuyuki Tanaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nobuyuki Tanaka has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Akane Miyazaki

    Chemical and biological science, Faculty of science, Japan Women’s University, Tokyo, Japan

    5 shared publications
  • Tatsuji Munaka

    Undergraduate School of Information and Telecommunication Engineering, Tokai University, Tokyo, Japan

    2 shared publications
  • A. Miyazaki

    Faculty of Science, Japan Women's University, Tokyo 112-8681, Japan

    1 shared publication
  • Arika Aizawa

    Faculty of Science Japan Women's University Tokyo Japan

    1 shared publication
  • Ayumi Takahara

    Chemical and biological science, Faculty of science, Japan Women’s University, Tokyo, Japan

    1 shared publication
  • Daiki Tanaka

    Faculty of Advanced Science and Engineering, Waseda University, Tokyo 162-0041, Japan

    1 shared publication

Latest Publications

  • Open Access

    Emissions of volatile organic compounds from a commercial hen shed in Japan

    by Nobuyuki Tanaka, Nanami Hanari, Ayumi Takahara, Akane Miyazaki, Genki Katata, Hisao Kuroda

  • Open Access

    Seasonal variation and temperature-dependent emission of volatile organic compounds from a commercial swine shed in Japan

    by Nobuyuki Tanaka, Kaho Nishimura, Akane Miyazaki, Hiroshi Hayami

    To quantify and characterize the emissions of volatile organic compounds (VOCs) from swine sheds—a major source of atmospheric pollutants—this study investigated VOC concentrations and emission rates in a commercial swine facility in Okinawa, Japan, across four seasons. Average VOC concentrations at the exhaust outlet Ranged from 480 to 750 µg m⁻3 with limited seasonal variation. Volatile fatty acids (VFAs), particularly acetic acid (31–38%), consistently dominated the VOC profile, followed by p-cresol, acetaldehyde, acetone, and ethanol. VFAs also made the largest contributions to both the OH radical reactivity (OHR) and ozone formation potential (OFP), indicating their significance in secondary pollutant formation. VOC emission rates (ERs) Ranged from 1.1 to 2.8 mg h⁻1 kg⁻1 and exhibited an exponential increase with temperature. The derived temperature–ER regression model was consistent with previous findings from other swine facilities, suggesting its broader applicability. Using this model, we estimated that annual VOC emissions from Japanese commercial swine sheds amount to approximately 10,000 tons, equivalent to 1.8% of the nation’s total VOC emissions. These findings highlight the livestock sector as a non-negligible contributor to national VOC inventories and suggest that mitigation strategies should account for animal husbandry emissions. Graphical Abstract


  • Open Access

    Temperature Control in Microfluidic Devices: Approaches, Challenges, and Future Directions

    by Faisal bin Nasser Sarbaland, Masashi Kobayashi, Daiki Tanaka, Risa Fujita, Nobuyuki Tanaka, Masahiro Furuya

    Accurate temperature regulation is essential in microfluidic apparatus, particularly for procedures such as polymerase chain reaction (PCR), cellular analysis, and chemical reactions that rely on stable thermal conditions. However, achieving temperature uniformity at the microscale remains challenging due to rapid heat dissipation, small thermal mass, and intricate flow–heat interactions. This work reviews contemporary methodologies to enhance thermal control in microfluidic systems, including proportional–integral–derivative (PID) and fuzzy PID controllers, liquid metal-based sensing, thermoelectric cooling (TECs), and evaporation or integrated heating elements for precise thermal output management. Emerging fabrication technologies, such as additive manufacturing, enable the direct integration of heating elements and sensors within microchips, improving thermal efficiency and device compactness. Advanced materials, including carbon nanotubes infused with gallium and temperature-sensitive quantum dots, offer innovative, non-contact thermal monitoring capabilities. Furthermore, artificial intelligence-driven feedback systems present opportunities for adaptive, real-time thermal optimization. By consolidating these strategies, this review highlights pathways to develop more dependable, efficient, and application-ready microfluidic devices, with implications for diagnostics, research, and other practical uses.


  • Open Access

    Relationship between human behavior and indoor air quality of private room in a care facility for the elderly in Japan

    by Nobuyuki Tanaka, Tatsuji Munaka, Joao Filipe Papel, Shun-Ichi Hattori, Toshiya Iwamatsu, Teruhisa Miura, Fujio Tsutsumi

    In Japan, the number of elderly people in need of nursing care is increasing while the population of young people is decreasing, and the potential for labor shortages in the field of elder care is of great concern. This study aimed to estimate the behavior of the elderly by using sensors to monitor indoor air quality (IAQ), without placing undue burden on the elderly or their caregivers. Odor and carbon dioxide (CO2) concentrations were monitored in a private room of a nursing home in the Kanto Region of Japan, the behaviors of the resident and staff members were recorded, and the relationship between the two was analyzed. Both odor and CO2 concentrations were higher when the resident was present than when absent, indicating that the resident was one of the main sources of indoor odor and CO2. In addition, after the resident entered the room, the CO2 concentration increased and remained stable, whereas the odor concentration tended to vary after the resident entered the room, first increasing and later decreasing. This suggested that the increase or decrease in odor could be used to monitor the behavior of the resident and staff members. The relationship between the slopes of odor and CO2 in typical behavioral events suggest that if only odor increases and CO2 does not change, the likelihood of the event in which feces were observed during diaper changes is high. In addition, based on the behavior near the sensor, the rate of CO2 and odor emissions differed between the elderly resident and the younger staff members, suggesting that the ratio of odor slope to CO2 slope may be greater in the elderly than in younger people. Furthermore, the repeated number of increases and decreases in odor and CO2 suggested that multiple events could be distinguished. These results suggest that IAQ can be utilized to estimate the behavior of residents and staff in nursing care facilities for the elderly.


  • Effect of farm Hazard Analysis and Critical Control Point (farm HACCP) certification efforts on emissions of volatile organic compounds from livestock sheds in Japan

    by Nobuyuki Tanaka, Arika Aizawa, Akane Miyazaki, Yoshitake Ando

    “Farm HACCP” incorporates the concept of Hazard Analysis and Critical Control Points (HACCP) into farm animal husbandry and sanitation management to ensure the safety of livestock products and improve productivity. Implementing farm HACCP may reduce the emission of volatile organic compounds (VOCs), which are derived from livestock manure and are responsible for odors, PM2.5, and photochemical oxidants. In this study, the effects of implementing farm HACCP on the emissions, composition, and environmental impact of VOCs from sheds were evaluated. VOCs in swine, dairy cattle, and hen sheds were measured before and after implementing farm HACCP. After implementing farm HACCP, the concentrations in the sheds were 55%–80% lower than the concentration in the sheds before. Odor activity values decreased in the cattle and hen sheds, whereas they increased in the swine shed. In addition, OH radical reactivity, an indicator of reactivity with OH radicals, decreased in all sheds. Finally, the emission rates of VOCs from each shed were estimated to be 42%–97% lower. These results suggest that implementing farm HACCP can reduce emissions of VOCs from livestock industries.


  • Open Access

    Investigation of Indoor Air Quality in Residential Buildings by Measuring CO2 Concentration and a Questionnaire Survey

    by Shunichi Hattori, Toshiya Iwamatsu, Teruhisa Miura, Fujio Tsutsumi, Nobuyuki Tanaka

    Indoor air quality (IAQ) in houses is often deteriorated by chemical substances emitted from heating, building materials, or other household goods. Since it is difficult for occupants to recognize air pollution, they rarely understand the actual conditions of the IAQ. An investigation into the actual condition of IAQ in houses was therefore conducted in this study. Carbon dioxide (CO2) concentrations in 24 occupied houses was measured, and the results from our analysis showed that the use of combustion heaters increased the concentration of CO2 and led to indoor air pollution. Results indicate that as outdoor temperature decreased, the frequency of ventilation decreased simultaneously, and CO2 concentration increased. Results of the questionnaire survey revealed that the actual IAQ in each house did not match the level of awareness its occupants had regarding ventilation. Along with this difficulty in perceiving air pollution, the lack of knowledge about ventilation systems and the effects of combustion heating may be additional barriers to IAQ awareness.


  • Open Access

    Influence of Human Behavior on Indoor Air Quality in a Care Facility for the Elderly in Japan

    by Nobuyuki Tanaka, Tatsuji Munaka

    Volatile organic compounds (VOCs), CO2, temperature, and humidity in a private room in a care facility for the elderly were measured and the behavior of a resident and staff were recorded in order to clarify the effects of the resident’s behavior, especially defecation, on indoor air quality. Average indoor concentrations of total VOCs (in μg m−3) in summer, autumn, and winter were 40.9, 16.7, and 18.8, respectively. Average indoor concentrations of CO2 in summer, autumn, and winter were 813, 761, and 1144 ppm, respectively, revealing a tendency for the concentrations of CO2 to be higher in winter, in contrast to the VOC concentration. The concentrations of VOCs and CO2 were 1.1 to 1.5 times higher when the resident was present in the room than when the resident was absent. This result suggests that one of the main sources of VOC and CO2 emissions in indoor air was the resident. Acetic acid, 1-butanol, propanoic acid, hexanoic acid, and phenol, which are contained in human sweat, exhaled air, and excrement, were the predominant VOCs in the air of the room regardless of the season, and these five components accounted for more than 90% of the total VOCs. The concentrations of these components were higher when the resident was present in the room, suggesting that the resident was the main source of these components. Based on the changes in the VOC and CO2 concentrations over time and the records of the resident and the staff, it was noted that VOC concentrations decreased, in some cases, before and after diaper changes. Our research suggests that certain aspects of the behavior of residents can be inferred by monitoring changes in indoor air quality.


  • Open Access

    Real-time Monitoring of Bioaerosol in a Residential Property in Central Tokyo

    by Nobuyuki Tanaka

    Real-time onsite monitoring of indoor airborne microbes in a residential property in central Tokyo was carried out in 2020 and 2021, following the onset of the COVID-19 pandemic. A microbial sensor utilizing fluorescence emitted by microorganisms was used to measure bioaerosol concentrations in the living room and children’s bedroom as well as on the balcony. Indoor PM2.5 was also monitored simultaneously at certain time points using a PM2.5 sensor. The behavior of the residents was also recorded during some monitoring periods. The average number concentration of microbes as fungi in the living room was 15,100, 58,800, and 10,600 counts m−3 in spring, summer, and winter, respectively, increasing in summer when the outside temperature was high. Microbial number concentrations were closely related to human behavior, increasing rapidly during periods of physical activity, but decreasing again within 20–30 min of the activity ending. There was no clear correlation between indoor microbial number concentrations and PM2.5 concentrations, suggesting that indoor microorganisms are concentrated in coarse particles, such as dust, which are quickly removed via gravitational settling. The concentration of indoor airborne microorganisms decreased significantly after ventilation, and although an occasional increase was observed immediately after ventilation, concentrations decreased again rapidly within 10–20 min. These results suggest that even a short period of ventilation can significantly reduce the indoor bioaerosol.


  • Open Access

    Emissions of Volatile Organic Compounds from a Dairy Cattle Shed in Japan

    by Nobuyuki Tanaka, Kaede Moriyama, Megumi Ohtsu, Akane Miyazaki

    To clarify the nature and characteristics of volatile organic compounds (VOCs) emitted from dairy cattle within a cattle shed located in Chiba, Japan, air samples were collected and analyzed for the four seasons in 2017–2018. Thirty-four VOCs were determined by gas chromatography-mass spectrometry and high performance liquid chromatography. In addition, air temperature and relative humidity inside and outside of the shed were monitored during each sampling campaign to estimate the ventilation rate of the shed. The average concentrations of total VOCs (μg m−3) in the shed in each season were 50.5 (spring), 128.4 (summer), 168.8 (autumn), and 199.5 (winter). Ketones were always the most dominant components followed by alcohols and volatile fatty acids (VFAs). The sum of ketones, alcohols, and VFAs accounted for more than 80% of the total VOCs in all seasons. Acetone, 3-pentanone, 1-butanol, and acetic acid were the major components regardless of the season, accounting for more than 60% of the total VOCs. The average emission rates of total VOCs from the shed (μg h−1 kg−1) were calculated to be 623 (spring), 1520 (summer), 585 (autumn) and 469 (winter). The emission rates of almost all the VOCs except alcohols increased exponentially with increase of air temperature in the shed. The ranges of the emission rates for each class of chemical (μg h−1 kg−1) were 39–170 (VFAs), 247–913 (ketones), 65–134 (alcohols), 40–122 (phenols), 10–122 (aldehydes), 4.17–22.3 (sulfur compounds), and 0.0067–0.74 (indoles). Furthermore, the annual emissions of VOCs for a single dairy cattle and for the cattle shed were estimated to be 5.5 kg and 44 kg, respectively.


  • Open Access

    Emissions of Volatile Organic Compounds from a Swine Shed

    by Nao Osaka, Akane Miyazaki, Nobuyuki Tanaka