Li Zhu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Li Zhu has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Fan Yang
School of Mechanical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Minhang District, Shanghai 200240, China
1 shared publication - Fan Yang
State Key Laboratory of Power Transmission Equipment Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
1 shared publication - Hanwu Luo
State Grid East Inner Mongolia Electric Power Maintenance Company, Tongliao 028000, China
1 shared publication - Hui Jiang
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, School of Electrical Engineering, Chongqing University, Chongqing 400044, China
1 shared publication - Jianjun Han
State Grid East Inner Mongolia Electric Power Maintenance Company, Tongliao 028000, China
1 shared publication - Jiansheng Li
School of Materials Science and Engineering, Anhui Polytechnic University, Wuhu 241000, China
1 shared publication
Latest Publications
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-16
Research on the Residual Magnetic Flux Density Measurement of Single-Phase Transformer Based on Magnetomotive Force
Accurately measuring the residual magnetism of a transformer is a prerequisite for developing its closing strategy to suppress inrush current. The existing methods mostly establish a function between response and remanence by applying excitation to transformer’s winding. However, when there is less residual magnetic flux in iron core, the response does not change significantly with residual magnetism, resulting in low measurement sensitivity and severely limiting the engineering application of such methods. To solve this issue, this paper proposes a remanence measurement method based on magnetomotive force, by establishing the function between the integral of magnetomotive force and iron core’s remanence under short-term pulse voltage. It can precisely measure residual magnetism throughout transformers’ entire residual magnetization range, especially solving the problem of low measurement sensitivity under small residual flux density. The proposed method was experimentally validated on the ring transformer and the single-phase two-column transformer, and it can effectively improve the measurement sensitivity under low remanence, with an average measurement error of less than 0.05T in the entire remanence range.
- 27 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-16
Research on the Residual Magnetic Flux Density Measurement of Single-Phase Transformer Based on Magnetomotive Force
Accurately measuring the residual magnetism of a transformer is a prerequisite for developing its closing strategy to suppress inrush current. The existing methods mostly establish a function between response and remanence by applying excitation to transformer’s winding. However, when there is less residual magnetic flux in iron core, the response does not change significantly with residual magnetism, resulting in low measurement sensitivity and severely limiting the engineering application of such methods. To solve this issue, this paper proposes a remanence measurement method based on magnetomotive force, by establishing the function between the integral of magnetomotive force and iron core’s remanence under short-term pulse voltage. It can precisely measure residual magnetism throughout transformers’ entire residual magnetization range, especially solving the problem of low measurement sensitivity under small residual flux density. The proposed method was experimentally validated on the ring transformer and the single-phase two-column transformer, and it can effectively improve the measurement sensitivity under low remanence, with an average measurement error of less than 0.05T in the entire remanence range.
- Open Access
- 1 June 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2290 (1) , 012084
Research on dual antenna design of RFID sensor
With the popularization and application of RFID sensors, the energy supply of internal circuits is a key problem. When multiple monitoring quantities are involved, the traditional energy extraction method of RFID sensors often leads to insufficient energy. Therefore, this paper designs an RFID sensor integrating acceleration and temperature sensing parameters, and proposes a cross placed dual antenna scheme. In order to increase the concentration of antenna radiation energy, a metal reflective aluminum plate is added. Through experimental tests, it is proved that the scheme can well optimize the radiation direction and performance of the antenna.
- 1 June 2022
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2290 (1) , 012084
Open AccessResearch on dual antenna design of RFID sensor
With the popularization and application of RFID sensors, the energy supply of internal circuits is a key problem. When multiple monitoring quantities are involved, the traditional energy extraction method of RFID sensors often leads to insufficient energy. Therefore, this paper designs an RFID sensor integrating acceleration and temperature sensing parameters, and proposes a cross placed dual antenna scheme. In order to increase the concentration of antenna radiation energy, a metal reflective aluminum plate is added. Through experimental tests, it is proved that the scheme can well optimize the radiation direction and performance of the antenna.
- Open Access
- 18 November 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (22) , 8151
FEM Analysis and Sensor-Based Measurement Scheme of Current Distribution for Grounding Electrode
The current distribution of the grounding electrode in a high-voltage direct current (HVDC) transmission system affects the state of power equipment in its vicinity, which depends on the soil resistivity and shape of the grounding electrode. In this paper, current distribution in the vicinity of an ±800 kV grounding electrode is investigated by simulation and experiments. Firstly, the model to calculate the current distribution with two typical frozen soils is set up, and simulation models and experimental platforms are established; meanwhile, the finite element method (FEM) is used to calculate the current and potential dispersion of linear, cross-shaped, and ring-shaped grounding electrodes in the simulation models. After obtaining the lab current data from the simulation, an innovative method based on a “drainage wire” with a Hall sensor is proposed to measure the current in an experimental setup. The results show that current and potential distribution characteristics are related to the shape of the grounding electrode and soil resistivity. Meanwhile, the current measurement scheme can measure the current in soil with a lower error. This article concludes that these two typical models can reduce the complexity of frozen soil analysis, and the measurement scheme can accurately monitor the current to reduce the damage to the surrounding power equipment.
- 18 November 2020
- Published by MDPI AG in Applied Sciences
- Vol. 10 (22) , 8151
Open AccessFEM Analysis and Sensor-Based Measurement Scheme of Current Distribution for Grounding Electrode
The current distribution of the grounding electrode in a high-voltage direct current (HVDC) transmission system affects the state of power equipment in its vicinity, which depends on the soil resistivity and shape of the grounding electrode. In this paper, current distribution in the vicinity of an ±800 kV grounding electrode is investigated by simulation and experiments. Firstly, the model to calculate the current distribution with two typical frozen soils is set up, and simulation models and experimental platforms are established; meanwhile, the finite element method (FEM) is used to calculate the current and potential dispersion of linear, cross-shaped, and ring-shaped grounding electrodes in the simulation models. After obtaining the lab current data from the simulation, an innovative method based on a “drainage wire” with a Hall sensor is proposed to measure the current in an experimental setup. The results show that current and potential distribution characteristics are related to the shape of the grounding electrode and soil resistivity. Meanwhile, the current measurement scheme can measure the current in soil with a lower error. This article concludes that these two typical models can reduce the complexity of frozen soil analysis, and the measurement scheme can accurately monitor the current to reduce the damage to the surrounding power equipment.