I. Francis Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
I. Francis Cheng has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Jeremy May
Department of Chemistry, University of Idaho, 875 Perimeter Dr, MS 2343, Moscow, Idaho 83844, United States
6 shared publications- David. N. McIlroy
Oklahoma State University
5 shared publications Dipak Koirala
Department of Chemistry, University of Idaho, 875 Perimeter Dr, Moscow, Idaho 83844, United States
4 shared publicationsHumayun Kabir
University of Idaho, Department of Chemistry, 875 Perimeter Dr, MS 2343, Moscow, ID, 83844, USA
4 shared publicationsKailash Hamal
Department of Chemistry, University of Idaho, 875 Perimeter Dr, MS 2343, Moscow, Idaho 83844, United States
4 shared publicationsNolan W. Nicholas
ABB Inc. – USCRC, 131 Phoenix Crossing, Bloomfield, CT, 06002, USA
4 shared publications
Latest Publications
- Open Access
- 25 June 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 16
Rapid single-molecule detection of Salmonella DNA based on an electrode surface-based polymerase chain reaction technique
There is a current need for rapid, selective and sensitive specific detection of Salmonella in food matrices. We demonstrate a technique for rapid single-molecule detection of Salmonella DNA based on an electrode surface-based polymerase chain reaction (PCR) based sensing of 48-base target single-stranded DNA (ssDNA) (CP014358.1 GenBank), chicken-juice matrix under 20 minutes. This is based on the covalent attachment of a probe ssDNA to pseudo-graphite. This sensor can be used in two different modes, without and with PCR, for lower limits of detection (LOD). The pseudo-graphite electrode is prepared for ssDNA attachment through the functionalization of its surface with carboxylate groups, which form amide linkages with amine-modified ssDNA. Without PCR, the probe-modified electrode is immersed in a sample complementary target matrix for 10 minutes, removed, and then placed into a solution of the double-stranded DNA (dsDNA) intercalator, cobalt(III) tris-phenanthroline. Detection of dsDNA formation between the probe and target sequences is achieved via the SWV of the surface-bound cobalt complex. The LOD of this method is 2.0 aM for the target within 12 minutes. Lower LOD’s are obtained by conducting PCR on the electrode surface. The on-electrode (oE) PCR process uses a 20-base primer attached to the pseudo-graphite. A chicken-juice sample matrix containing target ssDNA (48 bases of Salmonella typhimurium) was directly added to a PCR master mix with a reverse primer, placed in a standard PCR vial, and thermocycled 5 times. The electrode with surface-bound dsDNA was subjected to the cobalt(III) tris-phenanthroline protocol with a LOD of 35 zM. This is one DNA molecule within 17 minutes in a complex chicken-juice matrix.
- 25 June 2026
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 16
Open AccessRapid single-molecule detection of Salmonella DNA based on an electrode surface-based polymerase chain reaction technique
There is a current need for rapid, selective and sensitive specific detection of Salmonella in food matrices. We demonstrate a technique for rapid single-molecule detection of Salmonella DNA based on an electrode surface-based polymerase chain reaction (PCR) based sensing of 48-base target single-stranded DNA (ssDNA) (CP014358.1 GenBank), chicken-juice matrix under 20 minutes. This is based on the covalent attachment of a probe ssDNA to pseudo-graphite. This sensor can be used in two different modes, without and with PCR, for lower limits of detection (LOD). The pseudo-graphite electrode is prepared for ssDNA attachment through the functionalization of its surface with carboxylate groups, which form amide linkages with amine-modified ssDNA. Without PCR, the probe-modified electrode is immersed in a sample complementary target matrix for 10 minutes, removed, and then placed into a solution of the double-stranded DNA (dsDNA) intercalator, cobalt(III) tris-phenanthroline. Detection of dsDNA formation between the probe and target sequences is achieved via the SWV of the surface-bound cobalt complex. The LOD of this method is 2.0 aM for the target within 12 minutes. Lower LOD’s are obtained by conducting PCR on the electrode surface. The on-electrode (oE) PCR process uses a 20-base primer attached to the pseudo-graphite. A chicken-juice sample matrix containing target ssDNA (48 bases of Salmonella typhimurium) was directly added to a PCR master mix with a reverse primer, placed in a standard PCR vial, and thermocycled 5 times. The electrode with surface-bound dsDNA was subjected to the cobalt(III) tris-phenanthroline protocol with a LOD of 35 zM. This is one DNA molecule within 17 minutes in a complex chicken-juice matrix.
- 30 April 2026
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 2 (6) , 1453-1459
Rapidly Overcoming Inhibition of Taq Polymerase in Wastewater Media: 17-Minute Attomolar Detection of Nitrobacter Based on the On-Electrode PCR Technique
- 30 April 2026
- Published by American Chemical Society (ACS) in ACS Electrochemistry
- Vol. 2 (6) , 1453-1459
Rapidly Overcoming Inhibition of Taq Polymerase in Wastewater Media: 17-Minute Attomolar Detection of Nitrobacter Based on the On-Electrode PCR Technique
- Open Access
- 9 July 2025
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 15 (5) , 2705
Covalent attachment of aminoferrocene to pseudo-graphite for selective sensing of H2O2
Hydrogen peroxide is an important analyte from both the standpoints of in vivo and in vitro analyses. Electrochemical methods offer good prospects, but present sensing methods suffer from inadequate limits of detection (LOD), low sensitivity, poor stability, and numerous interferents. To address these issues, we use the recently recognized peroxidase-like activity of ferrocene for sensing based on the reductive electrocatalysis of H2O2. This route obviates interferences from ascorbate, urea, urate, dopamine and glucose. Immobilization of ferrocene overcomes its low aqueous solubility. This is done by the chemical modification of a pseudo-graphite material rich in sp3 defects. The surface is modified for carboxylate features through a diazonium intermediate formed through 4-aminobenzoic acid. Aminoferrocene is attached to surface carboxylate groups through a N-ethyl-N’-(3-(dimethylamino)propyl) carbodiimide coupling agent. Cyclic voltametric studies indicate that the surface concentration of ferrocene is 1.06 nmol cm-2. Chronoamperometric response at -0.6 V vs. Ag/AgCl, gives a LOD of 0.070 µM with a high sensitivity of 553.2 μA mM-1 cm-2. This is the best sensitivity reported in the literature. Furthermore, the sensor is stable over 50 cyclic voltametric scans, and between the 3 calibration-curve studies.
- 9 July 2025
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 15 (5) , 2705
Open AccessCovalent attachment of aminoferrocene to pseudo-graphite for selective sensing of H2O2
Hydrogen peroxide is an important analyte from both the standpoints of in vivo and in vitro analyses. Electrochemical methods offer good prospects, but present sensing methods suffer from inadequate limits of detection (LOD), low sensitivity, poor stability, and numerous interferents. To address these issues, we use the recently recognized peroxidase-like activity of ferrocene for sensing based on the reductive electrocatalysis of H2O2. This route obviates interferences from ascorbate, urea, urate, dopamine and glucose. Immobilization of ferrocene overcomes its low aqueous solubility. This is done by the chemical modification of a pseudo-graphite material rich in sp3 defects. The surface is modified for carboxylate features through a diazonium intermediate formed through 4-aminobenzoic acid. Aminoferrocene is attached to surface carboxylate groups through a N-ethyl-N’-(3-(dimethylamino)propyl) carbodiimide coupling agent. Cyclic voltametric studies indicate that the surface concentration of ferrocene is 1.06 nmol cm-2. Chronoamperometric response at -0.6 V vs. Ag/AgCl, gives a LOD of 0.070 µM with a high sensitivity of 553.2 μA mM-1 cm-2. This is the best sensitivity reported in the literature. Furthermore, the sensor is stable over 50 cyclic voltametric scans, and between the 3 calibration-curve studies.
- 31 October 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (45) , 16631-16638
Biosensing with Polymerase Chain Reaction-Stable DNA-Functionalized Magnetically Susceptible Carbon–Iron Microparticles
We demonstrate a rapid and sensitive method for DNA detection without the need for fluorescence. This is based on carbon-coated magnetic iron (Fe) microparticles with a covalent surface attachment of DNA. We show that these magnetic microparticles can capture complementary DNA. Significantly, the DNA covalent surface bonds are robust to high temperatures and can be included in a sample during polymerase chain reaction (PCR). This method is employed for the detection of targeted DNA sequences (40-50 bp). Hybridization probes on the surface of the magnetically susceptible Fe microparticle recognize the target DNA sequence-specifically. The double-stranded DNA (dsDNA) microparticles are then quickly captured with a magnet from the sample matrix. This foregoes postpurification processes, such as electrophoresis, which make our technique time- and cost-effective. Captured dsDNA can be detected with intercalating dyes such as ethidium bromide through a loss in the UV absorption signal with a limit of detection (LOD) of 24 nM within 15 min. Likewise, surface-bound DNA can act as a primer in PCR to decrease the LOD to 5 pM within 2 h. This is the first instance of a nucleotide-modified magnetically susceptible carbon substrate that is PCR-compatible. Besides DNA capture, this strategy can eventually be applied to sequence-specific nucleic acid purification and enrichment, PCR cleanup, and single-strand generation. The DNA-coated particles are stable under PCR conditions (unlike commonly used polystyrene or gold particles).
- 31 October 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (45) , 16631-16638
Biosensing with Polymerase Chain Reaction-Stable DNA-Functionalized Magnetically Susceptible Carbon–Iron Microparticles
We demonstrate a rapid and sensitive method for DNA detection without the need for fluorescence. This is based on carbon-coated magnetic iron (Fe) microparticles with a covalent surface attachment of DNA. We show that these magnetic microparticles can capture complementary DNA. Significantly, the DNA covalent surface bonds are robust to high temperatures and can be included in a sample during polymerase chain reaction (PCR). This method is employed for the detection of targeted DNA sequences (40-50 bp). Hybridization probes on the surface of the magnetically susceptible Fe microparticle recognize the target DNA sequence-specifically. The double-stranded DNA (dsDNA) microparticles are then quickly captured with a magnet from the sample matrix. This foregoes postpurification processes, such as electrophoresis, which make our technique time- and cost-effective. Captured dsDNA can be detected with intercalating dyes such as ethidium bromide through a loss in the UV absorption signal with a limit of detection (LOD) of 24 nM within 15 min. Likewise, surface-bound DNA can act as a primer in PCR to decrease the LOD to 5 pM within 2 h. This is the first instance of a nucleotide-modified magnetically susceptible carbon substrate that is PCR-compatible. Besides DNA capture, this strategy can eventually be applied to sequence-specific nucleic acid purification and enrichment, PCR cleanup, and single-strand generation. The DNA-coated particles are stable under PCR conditions (unlike commonly used polystyrene or gold particles).
- Open Access
- 7 September 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (19) , 4905
Correction: Voltammetric pH sensor based on electrochemically modified pseudo-graphite
Correction for ‘Voltammetric pH sensor based on electrochemically modified pseudo-graphite’ by Haoyu Zhu et al. , Analyst , 2020, 145 , 7252–7259, https://doi.org/10.1039/D0AN01405B.
- 7 September 2023
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 148 (19) , 4905
Open AccessCorrection: Voltammetric pH sensor based on electrochemically modified pseudo-graphite
Correction for ‘Voltammetric pH sensor based on electrochemically modified pseudo-graphite’ by Haoyu Zhu et al. , Analyst , 2020, 145 , 7252–7259, https://doi.org/10.1039/D0AN01405B.
- 19 April 2023
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 62 (17) , 6687-6696
Superhydrophilicity and Antifouling Behavior in Electrochemically Oxidized Nanocrystalline Pseudographite
- 19 April 2023
- Published by American Chemical Society (ACS) in Industrial & Engineering Chemistry Research
- Vol. 62 (17) , 6687-6696
Superhydrophilicity and Antifouling Behavior in Electrochemically Oxidized Nanocrystalline Pseudographite
- Open Access
- 5 September 2022
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 12 (5) , 1009-1023
An oxygen reduction reaction electrocatalyst tuned for hydrogen peroxide generation based on a pseudo-graphite doped with graphitic nitrogen
The carbon material, GUITAR (pseudo-graphite from the University of Idaho thermolyzed asphalt reaction) can be doped with nitrogen in two prevalent forms. In a previous study N(py)-GUITAR had a predominance of pyridinic and pyrrolic moieties with no graphitic nitrogen. In this study N(g)-GUITAR contains a 9.7 % N atomic abundance, with that fraction consisting of 72.3 % graphitic, 23.7 % pyridinic, and 0 % pyrrolic nitrogen. The two materials allow for the examination of hypotheses regarding the importance of the three different nitrogen moieties in the oxygen reduction reaction (ORR). In the previous investigation, the lack of graphitic nitrogen of N(py)-GUITAR gave a preferred pathway of 4e- ORR to H2O. In this investigation, N(g)-GUITAR gave a 2e- ORR pathway to H2O2. This was elucidated by current efficiency and hydrodynamic voltammetry studies. The high predominance of graphitic nitrogen confirms the hypothesis regarding 2e- vs. 4e- ORR pathways with N-doped carbon materials. N(g)-GUITAR was also evaluated for parasitic pathways for H2O2 production. At -0.95 V vs. Ag/AgCl the combination of current efficiency for H2O2 is 96 % in 0.05 M Na2SO4 with a production rate of 4.9 mg cm-2 h-1, is the highest reported in the literature. This indicates possibilities for water purification and treatment applications, which require 10 to 250 mg L-1, depending on conditions.
- 5 September 2022
- Published by International Association of Physical Chemists (IAPC) in Journal of Electrochemical Science and Engineering
- Vol. 12 (5) , 1009-1023
Open AccessAn oxygen reduction reaction electrocatalyst tuned for hydrogen peroxide generation based on a pseudo-graphite doped with graphitic nitrogen
The carbon material, GUITAR (pseudo-graphite from the University of Idaho thermolyzed asphalt reaction) can be doped with nitrogen in two prevalent forms. In a previous study N(py)-GUITAR had a predominance of pyridinic and pyrrolic moieties with no graphitic nitrogen. In this study N(g)-GUITAR contains a 9.7 % N atomic abundance, with that fraction consisting of 72.3 % graphitic, 23.7 % pyridinic, and 0 % pyrrolic nitrogen. The two materials allow for the examination of hypotheses regarding the importance of the three different nitrogen moieties in the oxygen reduction reaction (ORR). In the previous investigation, the lack of graphitic nitrogen of N(py)-GUITAR gave a preferred pathway of 4e- ORR to H2O. In this investigation, N(g)-GUITAR gave a 2e- ORR pathway to H2O2. This was elucidated by current efficiency and hydrodynamic voltammetry studies. The high predominance of graphitic nitrogen confirms the hypothesis regarding 2e- vs. 4e- ORR pathways with N-doped carbon materials. N(g)-GUITAR was also evaluated for parasitic pathways for H2O2 production. At -0.95 V vs. Ag/AgCl the combination of current efficiency for H2O2 is 96 % in 0.05 M Na2SO4 with a production rate of 4.9 mg cm-2 h-1, is the highest reported in the literature. This indicates possibilities for water purification and treatment applications, which require 10 to 250 mg L-1, depending on conditions.
- 7 June 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (12) , 10146-10155
Highly Stable, Low-Cost Metal-Free Oxygen Reduction Reaction Electrocatalyst Based on Nitrogen-Doped Pseudo-Graphite
- 7 June 2021
- Published by American Chemical Society (ACS) in Energy & Fuels
- Vol. 35 (12) , 10146-10155
Highly Stable, Low-Cost Metal-Free Oxygen Reduction Reaction Electrocatalyst Based on Nitrogen-Doped Pseudo-Graphite
- Open Access
Electrochemical Aspects of a Nitrogen-Doped Pseudo-Graphitic Carbon Material: Resistance to Electrode Fouling by Air-Aging and Dopamine Electro-Oxidation
The nitrogen-doped form of GUITAR (pseudo-Graphite from the University of Idaho Thermalized Asphalt Reaction) was examined by X-ray photoelectron, Raman, and X-ray diffraction spectroscopies and cyclic voltammetry (CV). Electrochemical studies indicate that N-GUITAR exhibits significant resistance to fouling by adsorption and by passivation. Unlike other carbon materials, it maintains fast heterogenous electron transfer (HET) kinetics with Fe(CN)63−/4− with exposure to air. The CV peak potential separation (ΔEp) of 66 mV increased to 69 mV in 3 h vs. 67 to 221 mV for a highly oriented pyrolytic graphite (HOPG) electrode. Water contact angle measurements indicate that N-GUITAR was able to better maintain a hydrophilic state during the 3-h exposure, going from 55.8 to 70.4° while HOPG increased from 63.8 to 80.1°. This indicates that N-GUITAR better resisted adsorption of volatile organic compounds. CV studies of dopamine also indicate N-GUITAR is resistant to passivation. The ΔEp for the dopamine/o-dopaminoquinone couple is 83 mV indicating fast HET rates. This is reflected in the peak current ratios for the oxidation and reduction processes of 1.3 indicating that o-dopaminoquinone is not lost to passivation processes. This ratio along with the minimal signal attenuation is the best reported in literature.
Open AccessElectrochemical Aspects of a Nitrogen-Doped Pseudo-Graphitic Carbon Material: Resistance to Electrode Fouling by Air-Aging and Dopamine Electro-Oxidation
The nitrogen-doped form of GUITAR (pseudo-Graphite from the University of Idaho Thermalized Asphalt Reaction) was examined by X-ray photoelectron, Raman, and X-ray diffraction spectroscopies and cyclic voltammetry (CV). Electrochemical studies indicate that N-GUITAR exhibits significant resistance to fouling by adsorption and by passivation. Unlike other carbon materials, it maintains fast heterogenous electron transfer (HET) kinetics with Fe(CN)63−/4− with exposure to air. The CV peak potential separation (ΔEp) of 66 mV increased to 69 mV in 3 h vs. 67 to 221 mV for a highly oriented pyrolytic graphite (HOPG) electrode. Water contact angle measurements indicate that N-GUITAR was able to better maintain a hydrophilic state during the 3-h exposure, going from 55.8 to 70.4° while HOPG increased from 63.8 to 80.1°. This indicates that N-GUITAR better resisted adsorption of volatile organic compounds. CV studies of dopamine also indicate N-GUITAR is resistant to passivation. The ΔEp for the dopamine/o-dopaminoquinone couple is 83 mV indicating fast HET rates. This is reflected in the peak current ratios for the oxidation and reduction processes of 1.3 indicating that o-dopaminoquinone is not lost to passivation processes. This ratio along with the minimal signal attenuation is the best reported in literature.
- 19 August 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (22) , 7252-7259
Voltammetric pH sensor based on electrochemically modified pseudo-graphite
A nanocrystalline graphite-like amorphous carbon (graphite from the University of Idaho thermolyzed asphalt reaction, GUITAR) shares morphological features with classical graphites, including basal and edge planes (BP, EP). However, unlike graphites and other sp2-hybridized carbons, GUITAR has fast heterogenous electron transfer (HET) across its basal planes, and resistance to corrosion similar to sp3-C and boron-doped diamond electrodes. In this contribution, quinoid modified BP-GUITAR (q-GUITAR) is examined as a sensor for pH determination. This modification is performed by applying 2.0 V (vs. Ag/AgCl) for 150 seconds followed by 15 cyclic voltammetric scans from −0.7 to 1.0 V at 50 mV s−1 in 1.0 M H2SO4. The quinoid surface coverage of q-GUITAR is 1.35 × 10−9 mol cm−2, as measured by cyclic voltammetry. X-ray photoelectron spectroscopy analysis also confirms the high surface coverage. The quinoid surface concentration ranks highest in literature when compared with other basal plane graphitic materials. This yields a sensor that responds through a square wave voltammetric reduction peak shift of 63.3 mV per pH over a pH range from 0 to 11. The response on q-GUITAR is stable for >20 measurements and no surface re-activation is required between the measurements. The common interferents, Na+, K+ and dissolved oxygen, have no effect on the response of the q-GUITAR-based pH sensor.
- 19 August 2020
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 145 (22) , 7252-7259
Voltammetric pH sensor based on electrochemically modified pseudo-graphite
A nanocrystalline graphite-like amorphous carbon (graphite from the University of Idaho thermolyzed asphalt reaction, GUITAR) shares morphological features with classical graphites, including basal and edge planes (BP, EP). However, unlike graphites and other sp2-hybridized carbons, GUITAR has fast heterogenous electron transfer (HET) across its basal planes, and resistance to corrosion similar to sp3-C and boron-doped diamond electrodes. In this contribution, quinoid modified BP-GUITAR (q-GUITAR) is examined as a sensor for pH determination. This modification is performed by applying 2.0 V (vs. Ag/AgCl) for 150 seconds followed by 15 cyclic voltammetric scans from −0.7 to 1.0 V at 50 mV s−1 in 1.0 M H2SO4. The quinoid surface coverage of q-GUITAR is 1.35 × 10−9 mol cm−2, as measured by cyclic voltammetry. X-ray photoelectron spectroscopy analysis also confirms the high surface coverage. The quinoid surface concentration ranks highest in literature when compared with other basal plane graphitic materials. This yields a sensor that responds through a square wave voltammetric reduction peak shift of 63.3 mV per pH over a pH range from 0 to 11. The response on q-GUITAR is stable for >20 measurements and no surface re-activation is required between the measurements. The common interferents, Na+, K+ and dissolved oxygen, have no effect on the response of the q-GUITAR-based pH sensor.