Muhammad Raza Ul Islam
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Muhammad Raza Ul Islam has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Shaoping Bai
3 shared publicationsAsim Waris
Department of Biomedical Engineering and Sciences, National University of Sciences and Technology, Islamabad, Pakistan
1 shared publicationErnest Nlandu Kamavuako
Department of Informatics, King’s College, London, UK
1 shared publicationKun Xu
Beihang University
1 shared publication- Shaoping Bai
Department of Materials and Production, Aalborg University, 9220 Aalborg, Denmark
1 shared publication
Latest Publications
- Open Access
- 20 November 2022
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 4
A novel approach of FMG sensors distribution leading to subject independent approach for effective and efficient detection of forearm dynamic movements
- 20 November 2022
- Published by Elsevier in Biomedical Engineering Advances
- Vol. 4
Open AccessA novel approach of FMG sensors distribution leading to subject independent approach for effective and efficient detection of forearm dynamic movements
- Open Access
- 1 January 2020
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 7
A comparative study of motion detection with FMG and sEMG methods for assistive applications
Introduction: While surface-electromyography (sEMG) has been widely used in limb motion detection for the control of exoskeleton, there is an increasing interest to use forcemyography (FMG) method to detect motion. In this paper, we review the applications of two types of motion detection methods. Their performances were experimentally compared in day-to-day classification of forearm motions. The objective is to select a detection method suitable for motion assistance on a daily basis. Methods: Comparisons of motion detection with FMG and sEMG were carried out considering classification accuracy (CA), repeatability and training scheme. For both methods, classification of motions was achieved through feed-forward neural network. Repeatability was evaluated on the basis of change in CA between days and also training schemes. Results: The experiments shows that day-to-day CA with FMG can reach 84.9%, compared with a CA of 77.8% with sEMG, when the classifiers were trained only on the first day. Moreover, the CA with FMG can reach to 86.5%, comparable to CA of 84.1% with sEMG, if classifiers were trained daily. Conclusions: Results suggest that data recorded from FMG is more repeatable in day-to-day testing and therefore FMG-based methods can be more useful than sEMG-based methods for motion detection in applications where exoskeletons are used as needed on a daily basis.
- 1 January 2020
- Published by SAGE Publications in Journal of Rehabilitation and Assistive Technologies Engineering
- Vol. 7
Open AccessA comparative study of motion detection with FMG and sEMG methods for assistive applications
Introduction: While surface-electromyography (sEMG) has been widely used in limb motion detection for the control of exoskeleton, there is an increasing interest to use forcemyography (FMG) method to detect motion. In this paper, we review the applications of two types of motion detection methods. Their performances were experimentally compared in day-to-day classification of forearm motions. The objective is to select a detection method suitable for motion assistance on a daily basis. Methods: Comparisons of motion detection with FMG and sEMG were carried out considering classification accuracy (CA), repeatability and training scheme. For both methods, classification of motions was achieved through feed-forward neural network. Repeatability was evaluated on the basis of change in CA between days and also training schemes. Results: The experiments shows that day-to-day CA with FMG can reach 84.9%, compared with a CA of 77.8% with sEMG, when the classifiers were trained only on the first day. Moreover, the CA with FMG can reach to 86.5%, comparable to CA of 84.1% with sEMG, if classifiers were trained daily. Conclusions: Results suggest that data recorded from FMG is more repeatable in day-to-day testing and therefore FMG-based methods can be more useful than sEMG-based methods for motion detection in applications where exoskeletons are used as needed on a daily basis.
- Open Access
- 1 January 2019
- Published by Norwegian Society of Automatic Control in Modeling, Identification and Control: A Norwegian Research Bulletin
- Vol. 40 (4) , 189-198
Payload estimation using forcemyography sensors for control of upper-body exoskeleton in load carrying assistance
In robotic assistive devices, the determination of required assistance is vital for proper functioning of assistive control. This paper presents a novel solution to measure conveniently and accurately carried payload in order to estimate the required assistance level. The payload is estimated using upper arm forcemyography (FMG) through a sensor band made of force sensitive resistors. The sensor band is worn on the upper arm and is able to measure the change of normal force applied due to muscle contraction. The readings of the sensor band are processed using support vector machine (SVM) regression technique to estimate the payload. The developed method was tested on human subjects, carrying a payload. Experiments were further conducted on an upper-body exoskeleton to provide the required assistance. The results show that the developed method is able to estimate the load carrying status, which can be used in exoskeleton control to provide effectively physical assistance needed.
- 1 January 2019
- Published by Norwegian Society of Automatic Control in Modeling, Identification and Control: A Norwegian Research Bulletin
- Vol. 40 (4) , 189-198
Open AccessPayload estimation using forcemyography sensors for control of upper-body exoskeleton in load carrying assistance
In robotic assistive devices, the determination of required assistance is vital for proper functioning of assistive control. This paper presents a novel solution to measure conveniently and accurately carried payload in order to estimate the required assistance level. The payload is estimated using upper arm forcemyography (FMG) through a sensor band made of force sensitive resistors. The sensor band is worn on the upper arm and is able to measure the change of normal force applied due to muscle contraction. The readings of the sensor band are processed using support vector machine (SVM) regression technique to estimate the payload. The developed method was tested on human subjects, carrying a payload. Experiments were further conducted on an upper-body exoskeleton to provide the required assistance. The results show that the developed method is able to estimate the load carrying status, which can be used in exoskeleton control to provide effectively physical assistance needed.
- 14 October 2018
- Published by Springer Nature
- p. 3-7
Position Sensing and Control with FMG Sensors for Exoskeleton Physical Assistance
- 14 October 2018
- Published by Springer Nature
- p. 3-7
Position Sensing and Control with FMG Sensors for Exoskeleton Physical Assistance