KCKrzysztof Czechowicz

Krzysztof Czechowicz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Krzysztof Czechowicz has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Invasive validation of novel 1D models for computation of coronary fractional flow reserve

    by Daniel J Taylor, Harry Saxton, Xu Xu, Eron Yones, Louise Aubiniere-Robb, Thilanka Adikari, Tom Newman, Marcel van ‘t Veer, Daniëlle C J Keulards, Pim Tonino, et al.

    Aims: Computed virtual fractional flow reserve (vFFR), derived from invasive angiography, non-invasively quantifies coronary epicardial lesion physiology. Developments of 1-dimensional (1D) vFFR models have introduced methods of side-branch flow representation and reduced simulation time by several orders of magnitude vs. 3-dimensional (3D) alternatives. This study aimed to quantify agreement and diagnostic accuracy of 1D and 3D vFFR models, in a matched cohort, and compare results with established FFR alternatives. Methods and results: We used five 1D models, which differed in their side-branch flow representation, to compute vFFR in 104 arteries. The simplest model ignored side-branch flow, the second and third models used vessel anatomy to homogenously distribute side-branch flow and regionalize this to bifurcations, respectively. The final two 1D models additionally used simulated pressure in the main vessel to modulate side-branch flow magnitude. To aid interpretability, diagnostic accuracy was also reported for 3D vFFR, visual assessment and resting invasive pressure assessment (Pd/Pa). Median FFR was 0.81 [0.73–0.88] and 46 (44%) lesions were haemodynamically significant. Optimal FFR agreement was achieved with the 1D model that regionalized side-branch flow to bifurcations (mean bias at diagnostic threshold −0.03, 95% agreement limits −0.23 to 0.20). Diagnostic accuracy did not differ significantly between the five 1D models, with area under the curve (AUC) values ranging 0.68 to 0.74. Diagnostic accuracy for 1D vFFR was superior to visual assessment, comparable to 3D vFFR and poorer than invasive resting pressure assessment. Conclusion: 1D models of vFFR facilitate rapid in-silico assessment of epicardial lesion severity. Inclusion of anatomical side branch flow mildly improved agreement, but the additional inclusion of simulated pressure was not beneficial. Agreement of 1D models was comparable to 3D simulations. However, current 1D models are not sufficiently accurate to suggest they may entirely replace wire-based assessment.


  • Derivation and Sensitivity Analysis of a Novel One-Dimensional Model of Coronary Blood Flow Accounting for Vessel Taper & Boundary Slip

    by Harry Saxton, Daniel J Taylor, Xu Xu, Andrew Narracott, Krzysztof Czechowicz, Tom Newman, Rebecca Gosling, David R. Hose, Leif Rune Hellevik, Julian P Gunn, et al.

    Computational models of coronary flow allow quantification of virtual fractional flow reserve (vFFR) and absolute flow, reducing the need for invasive testing in supporting a diagnosis of ischaemic heart disease (IHD). One-dimensional (1D) models of coronary flow are an emerging tool, which provide rapid assessment of coronary physiology. However, they currently do not fully account for side branch flow, the importance of which for clinically indeterminate cases is disputed. In the current study, we derive a novel 1D model of coronary flow from the Navier-Stokes equations, which accounts for vessel taper, convective acceleration and boundary slip. Using 15 idealised coronary arterial anatomies derived from patient data, we compared vFFR results from our model with those from a pre-existing 1D model of coronary flow. The techniques showed strong correlation (r=0.99, p < 0.001) with close agreement. Through a novel output-constrained global sensitivity analysis (GSA), we demonstrated that anatomical parameters, particularly the magnitude of simulated side branches significantly influences vFFR in the diagnostic grey zone (0.75 - 0.85) and absolute coronary flow regardless of stenosis severity. This challenges the commonly accepted dominance of stenosis parameters. We present a more mathematically and anatomically consistent 1D system for modelling coronary flow, which demonstrated modest differences with established models. GSA highlighted the influence of the flow diameter (Murray) scaling exponent in all cases when computing flow and in intermediate epicardial stenoses when quantifying vFFR. This work highlights the importance of accurately quantifying side branch flow when computing virtual coronary physiology.


  • Open Access

    Validation of a novel numerical model to predict regionalized blood flow in the coronary arteries

    by Daniel J Taylor, Jeroen Feher, Krzysztof Czechowicz, Ian Halliday, D R Hose, Rebecca Gosling, Louise Aubiniere-Robb, Marcel van ‘T Veer, Danielle C J Keulards, Pim Tonino, et al.

    Aims: Ischaemic heart disease results from insufficient coronary blood flow. Direct measurement of absolute flow (mL/min) is feasible, but has not entered routine clinical practice in most catheterization laboratories. Interventional cardiologists, therefore, rely on surrogate markers of flow. Recently, we described a computational fluid dynamics (CFD) method for predicting flow that differentiates inlet, side branch, and outlet flows during angiography. In the current study, we evaluate a new method that regionalizes flow along the length of the artery.Methods and results: Three-dimensional coronary anatomy was reconstructed from angiograms from 20 patients with chronic coronary syndrome. All flows were computed using CFD by applying the pressure gradient to the reconstructed geometry. Side branch flow was modelled as a porous wall boundary. Side branch flow magnitude was based on morphometric scaling laws with two models: a homogeneous model with flow loss along the entire arterial length; and a regionalized model with flow proportional to local taper. Flow results were validated against invasive measurements of flow by continuous infusion thermodilution (Coroventis™, Abbott). Both methods quantified flow relative to the invasive measures: homogeneous (r 0.47, P 0.006; zero bias; 95% CI −168 to +168 mL/min); regionalized method (r 0.43, P 0.013; zero bias; 95% CI −175 to +175 mL/min).Conclusion: During angiography and pressure wire assessment, coronary flow can now be regionalized and differentiated at the inlet, outlet, and side branches. The effect of epicardial disease on agreement suggests the model may be best targeted at cases with a stenosis close to side branches.


  • Open Access

    A novel method for measuring absolute coronary blood flow and microvascular resistance in patients with ischaemic heart disease

    by Paul D Morris, Rebecca Gosling, Iwona Zwierzak, Holli Evans, Louise Aubiniere-Robb, Krzysztof Czechowicz, Paul C Evans, D Rodney Hose, Patricia V Lawford, Andrew J Narracott, et al.

    Ischaemic heart disease is the reduction of myocardial blood flow, caused by epicardial and/or microvascular disease. Both are common and prognostically important conditions, with distinct guideline-indicated management. Fractional flow reserve (FFR) is the current gold-standard assessment of epicardial coronary disease but is only a surrogate of flow and only predicts percentage flow changes. It cannot assess absolute (volumetric) flow or microvascular disease. The aim of this study was to develop and validate a novel method that predicts absolute coronary blood flow and microvascular resistance (MVR) in the catheter laboratory. A computational fluid dynamics (CFD) model was used to predict absolute coronary flow (QCFD) and coronary MVR using data from routine invasive angiography and pressure-wire assessment. QCFD was validated in an in vitro flow circuit which incorporated patient-specific, three-dimensional printed coronary arteries; and then in vivo, in patients with coronary disease. In vitro, QCFD agreed closely with the experimental flow over all flow rates [bias +2.08 mL/min; 95% confidence interval (error range) −4.7 to +8.8 mL/min; R2 = 0.999, P < 0.001; variability coefficient In vivo, QCFD and MVR were successfully computed in all 40 patients under baseline and hyperaemic conditions, from which coronary flow reserve (CFR) was also calculated. QCFD-derived CFR correlated closely with pressure-derived CFR (R2 = 0.92, P < 0.001). This novel method was significantly more accurate than Doppler-wire-derived flow both in vitro (±6.7 vs. ±34 mL/min) and in vivo (±0.9 vs. ±24.4 mmHg). Absolute coronary flow and MVR can be determined alongside FFR, in absolute units, during routine catheter laboratory assessment, without the need for additional catheters, wires or drug infusions. Using this novel method, epicardial and microvascular disease can be discriminated and quantified. This comprehensive coronary physiological assessment may enable a new level of patient stratification and management.


  • Open Access

    Observations of mineralised tissues of teeth in X-ray micro-computed tomography

    by R. Chałas, K. Szlązak, I. Wójcik-Chęcińska, J. Jaroszewicz, R. Molak, K. Czechowicz, S. Paris, W. Święszkowski, K. J. Kurzydłowski

    The one of the most recent imaging technology is X-ray microtomography which allows non-invasive three-dimensional visualisation of structures. It also offers the opportunity to conduct a comprehensive quantitative analysis of the tested objects such as measuring the shares of the various phases, determining the material density and distribution of the size of pores and particles. The aim of the paper was to present an overview on the applicability and relevance of X-ray microtomography in the study of mineralised tissues of the teeth. The article is based on the most recent and significant literature and own observations. The use of X-ray microtomography in dentistry has recently increased and includes, inter alia, the assessment of the density of minerals in enamel and dentin, the detection of demineralisation in an artificially and a naturally induced caries, the automatic measurement of the depth of cavities in dentin, the measurement of the amount of removed dentin in preparation of carious lesions by various methods, the assessment of microleakage around fillings and fissure sealants, cortical bone density measurement, evaluation of root canal morphology, comparison of the accuracy of root canal working and filling by various methods. X-ray microtomography offers within the analysis of mineralised tissues - complex structures of bone, teeth and biomedical materials, turn out to be indispensable since it opens new opportunities for cognitive and implementation research.