Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Papa Silly Traore has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A high sensitivity digital giant magneto-impedance (GMI) sensor for magnetic communication

    by Miao Xu, Papa Silly Traore, Aktham Asfour

    A high sensitivity Magneto-Impedance (GMI) sensor for magnetic communication systems in harsh environments is presented. In this system, the receiving coil of a conventional magnetic communication system is replaced by a high sensitivity GMI sensor and its digital electronic conditioning as well as digital signal processing. The whole architecture of the sensor is described in detail. It achieves two digital amplitude demodulations to recover, in real time, the binary sequence of the message sent by the transmitter. The demonstration and the validation of the reliable functioning of the system are illustrated through the transmission of messages using On-Off-Keying modulation method. The measured equivalent magnetic noise of the sensor was about noise 2   p T / Hz at 60 kHz, which is largely lower than the noise of other potential types of magnetic sensors such as Anisotropic Magneto-Resistive sensors for this application. This noise level suggests a potential higher communication range. When compared with an inductive coil, the developed sensor also presented an almost flat and sufficiently wide bandwidth compatible with magnetic communication. This bandwidth could potentially be extended according to the application.


  • Introduction of real-time digital processing techniques for the high-sensitivity GMI sensors

    by Papa Silly Traore, Aktham Asfour, Jean Paul Yonnet, Cedric Boudinet

    A new fully digital Giant Magneto-Impedance (GMI) sensor is presented. The design combines the off-diagonal configuration of the sensitive element with a real-time digital electronic conditioning based on a Software Defined Radio (SDR). Compared to a conventional implementation of these sensors, the proposed design exhibits key advantages. These include firstly the simplicity of obtaining a quasi-linear sensor response around the zero-field point without making use of a bias magnetic field and an offset cancelling device. Secondly, the potential of integration, the flexibility of reconfiguration as well as the low-noise and high-sensitivity are promising features of the developed concept. Noise performance of 1.8 pT/[ ] was obtained in the white noise region.


  • Practical Use of the GMI Effect to Make a Current Sensor

    by Aktham Asfour, Julie Nabias, Papa Silly Traore, Jean-Paul Yonnet

    This paper deals with practical issues and solutions related to the use of the giant magnetoimpedance (GMI) for electrical current measurement. It presents an overview of a full attempt of design and realization of an almost industrial GMI-based current sensor or clamp. The sensor combines dc and ac measurements with the same flexible sensitive element. This paper addresses several practical problems encountered in a real measurement environment. In this context, main attention was paid to the impact of the influence quantities that largely condition the implementation strategies and solutions of the sensor. For the intended industrial application, these influence quantities first include the operating temperature. Its impact on the intrinsic sensor response was investigated in an almost industrial temperature range. Second, bending stress on the sensitive element is another involved influence parameter in the toroidal and flexible structure of the sensor. The effect of this was also characterized. Finally, the third considered influence parameter is the effect of magnetic disturbances. These include the eccentricity of the conductor of interest and the impact of the surrounding magnetic fields such as the earth's field or fields produced by other conductors in close proximity to the sensor. Different strategies of implementation and solutions, taking into account the impact of influence parameters, were proposed and compared. A sensor prototype was realized, and its first performances were given.


  • Noise Performance of SDR-Based Off-Diagonal GMI Sensors

    by Papa-Silly Traore, Aktham Asfour, Jean-Paul Yonnet, Christophe P. Dolabdjian

    In this paper, we propose a general model to evaluate the equivalent magnetic noise for an off-diagonal giant magneto-impedance (GMI) sensor utilizing a software-defined radio (SDR) as a digital receiver. Based on this SDR approach, an analog-to-digital conversion (ADC) of the voltage induced by the sensing element is directly performed. The signal processing is digitally achieved in real time. It includes a digital quadrature demodulation, a decimation, and a filtering. The approach allows to give the key rules for quantifying the white noise level of this digital implementation. The voltage noise spectral density of the ADC and of each SDR stage is given. The white noise level expected by the modeling was in good agreement with the measurements. With a sensing element composed of a 400 turn coil wound around a co-rich GMI wire, equivalent magnetic noise levels of 220 and 4.2 pT/√Hz were obtained at 1 Hz and in the white noise region, respectively. The potential improvement of these performances, allowed by this digital conditioning, as well as limitations is also discussed.


  • Amplitude measurement with limiting amplifier for GMI magnetic sensor

    by Aktham Asfour, Jean-Paul Yonnet, Papa Silly Traore, Manel Zidi

    A novel system for amplitude measurement in Giant Magneto-Impedance (GMI) sensors has been developed. It combines a high-speed limiting amplifier with an artful use of feedback. The resulting device is a very efficient detector that allows measuring signals of amplitude as low as few tens of millivolts and of frequency as high as few tens of megahertz. A key advantage of this new concept is that the final detection performance and gain depend only on the passive components (resistors only) of the feedback circuit. This is why the detector exhibits outstanding linearity features, especially for low amplitude, when compared with the commercially available diode-based peak detectors which are typically employed in the GMI sensors. The limiting amplifier detector has been successfully used for GMI sensor.


  • Current source dedicated for direct digital synthesizers: Application to the giant magneto-impedance (GMI) sensors

    by Aktham Asfour, Jean-Paul Yonnet, Manel Zidi, Julie Nabias, Papa Silly Traore

    A new design of a High Frequency (HF) current source for GMI magnetic sensors is presented. In this design, a Direct Digital Synthesizer (DDS) is coupled to a current pump to form a voltage-controlled current source. This source is capable of supplying HF currents (with optional DC level) with constant amplitude for a reasonable range of GMI load impedances and for frequencies up to more than 10 MHz. The electronic schematic of the current pump is given. The impact of its use on the correction of the GMI sensor output in open-loop is illustrated through a comparison with a voltage-to-current converter based on the use of a traditional injection resistor.


  • Implementation of the Digital-Down-Conversion (DDC) and software for the optimization of the Giant Magneto-Impedance (GMI) sensors

    by Papa Silly Traore, Aktham Asfour, Jean-Paul Yonnet

    This paper deals with the implementation of the Digital-Down-Conversion (DDC) for signal demodulation and processing in Giant Magneto-Impedance (GMI) sensors. In this approach, a direct Analog-to-Digital Conversion (ADC) of the voltage across the sensing element is performed. The signal processing is then digitally done in real time. This processing mainly includes the digital quadrature demodulation, decimation and filtering. A description of the approach and its implementation for the GMI magnetic sensors are given. The system is fully programmable by software. This is why this approach is of great value for the automatic and real-time optimization of various physical parameters that impact the sensitivity and resolution of these sensors.