Junfang Xia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Junfang Xia has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Li Wang
College of Food Science and Engineering, Northwest A&F University, Yangling, 712100, Shaanxi, PR China; School of Chemistry, Guangzhou Key Laboratory of Analytical Chemistry for Biomedicine, South China Normal University, Guangzhou, 510006, PR China.
2 shared publications - Boyang Sun
College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
1 shared publication Cheng Liu
School of Medical Instrument and Food Engineering University of Shanghai for Science and Technology Shanghai China
1 shared publicationChenyu Xuan
College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
1 shared publicationHaijuan Zeng
School of Medical Instrument and Food Engineering University of Shanghai for Science and Technology Shanghai China
1 shared publicationHaiyu Wu
College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China
1 shared publication
Latest Publications
- 30 April 2024
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 12 (19) , 7541-7552
Self-Assembly of Cinnamic Acid-Modified Chitosan Surfactants: Synthesis, Characterization, and Applications in Emulsification
- 30 April 2024
- Published by American Chemical Society (ACS) in ACS Sustainable Chemistry & Engineering
- Vol. 12 (19) , 7541-7552
Self-Assembly of Cinnamic Acid-Modified Chitosan Surfactants: Synthesis, Characterization, and Applications in Emulsification
- 2 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (3) , 1232-1240
Trifunctional Nanocomposites with Colorimetric Magnetic Catalytic Activities Labels in Sandwich Immunochromatographic Detection of Escherichia coli O157:H7
The emergence of nanoenzymes has catalyzed the robust advancement of the lateral flow immunoassay (LFIA) in recent years. Among them, multifunctional nanocomposite enzymes with core-shell architectures are considered preferable for promoting the sensing ability due to their good biocompatibility, precise control over size, and surface properties etc. Herein, we developed a dual-channel ensured lateral flow immunoassay (DFLIA) platform utilizing a magnetic, colorimetric, and catalytic multifunctional nanocomposite enzyme (Fe3O4@TCPP@Pd) [TCPP, Tetrakis (4-carboxyphenyl) porphyrin] for the ultrasensitive and highly accurate rapid detection of Escherichia coli O157:H7 (E. coli O157:H7). Fe3O4@TCPP@Pd-mAb exhibits superior performance compared to traditional AuNPs, including enhanced sensitivity and an extended linear detection range, benefiting from its high brightness signal, strong magnetic separation ability, and high peroxidase activity (Vmax = 2.32 μM S1-). Moreover, the Fe3O4@TCPP@Pd-labeled mAb probe exhibited exceptional stability and high affinity toward E. coli O157:H7 (with an affinity constant of approximately 1.723 × 109 M-1), indicating its potential for the efficient capture of the pathogen. Impressively, the developed Fe3O4@TCPP@Pd-DFLIA achieved ultrasensitive detection for E. coli O157:H7 with pre- and postcatalytic naked-eye detection sensitivities of 255 cfu/mL and 77 cfu/mL, respectively, representing an approximately 41-fold improvement over the conventional AuNP-based LFIA and also possessed good specificity and reproducibility [relative standard deviation (RSD) < 10%]. Additionally, the established DFLIA exhibited satisfactory recoveries in detecting pork and milk samples, further validating the reliability of this platform for immunoassays and demonstrating its potential for utilization in bioassays and clinical diagnostics.
- 2 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (3) , 1232-1240
Trifunctional Nanocomposites with Colorimetric Magnetic Catalytic Activities Labels in Sandwich Immunochromatographic Detection of Escherichia coli O157:H7
The emergence of nanoenzymes has catalyzed the robust advancement of the lateral flow immunoassay (LFIA) in recent years. Among them, multifunctional nanocomposite enzymes with core-shell architectures are considered preferable for promoting the sensing ability due to their good biocompatibility, precise control over size, and surface properties etc. Herein, we developed a dual-channel ensured lateral flow immunoassay (DFLIA) platform utilizing a magnetic, colorimetric, and catalytic multifunctional nanocomposite enzyme (Fe3O4@TCPP@Pd) [TCPP, Tetrakis (4-carboxyphenyl) porphyrin] for the ultrasensitive and highly accurate rapid detection of Escherichia coli O157:H7 (E. coli O157:H7). Fe3O4@TCPP@Pd-mAb exhibits superior performance compared to traditional AuNPs, including enhanced sensitivity and an extended linear detection range, benefiting from its high brightness signal, strong magnetic separation ability, and high peroxidase activity (Vmax = 2.32 μM S1-). Moreover, the Fe3O4@TCPP@Pd-labeled mAb probe exhibited exceptional stability and high affinity toward E. coli O157:H7 (with an affinity constant of approximately 1.723 × 109 M-1), indicating its potential for the efficient capture of the pathogen. Impressively, the developed Fe3O4@TCPP@Pd-DFLIA achieved ultrasensitive detection for E. coli O157:H7 with pre- and postcatalytic naked-eye detection sensitivities of 255 cfu/mL and 77 cfu/mL, respectively, representing an approximately 41-fold improvement over the conventional AuNP-based LFIA and also possessed good specificity and reproducibility [relative standard deviation (RSD) < 10%]. Additionally, the established DFLIA exhibited satisfactory recoveries in detecting pork and milk samples, further validating the reliability of this platform for immunoassays and demonstrating its potential for utilization in bioassays and clinical diagnostics.
- Open Access
- 1 June 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 792 (1) , 012007
Combination blade roller for straw returning cultivator
The straw was buried in field in transitory and busy farming season whether it’s paddy or dry land. Mechanized straw application was beneficial to solve the problem of straw burning, and also conducive to the fertility of soil and beneficial to soil improvement. It was an important measure to develop ecological agriculture and agriculture sustainable development. In order to solve the problem of crop residue burning, we designed a straw burying rotary tiller. It can bury crop straw not only in wet land, but also in dry land. It is suitable for tillage in middle and lower reaches of Yangtze River, where the principal crop rotation is wet land rice after dry land crop annually. Based on our previous research achievements, the cultivator for high stubble returning in paddy field and so on, are widely used. So there are two main kinds of cultivating blades in this rotary tiller. They are rotary blades IIT245 and spiral blades. The former blades are used to cut soil, while the latter blades are to bury straw. The results provide the basis for the structure optimization of the cultivator for straw returning and the improvement of its working performance, and also provide a suitable implement to achieve high stubble straw mulching and soil tillage in paddy field and dry land.
- 1 June 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 792 (1) , 012007
Open AccessCombination blade roller for straw returning cultivator
The straw was buried in field in transitory and busy farming season whether it’s paddy or dry land. Mechanized straw application was beneficial to solve the problem of straw burning, and also conducive to the fertility of soil and beneficial to soil improvement. It was an important measure to develop ecological agriculture and agriculture sustainable development. In order to solve the problem of crop residue burning, we designed a straw burying rotary tiller. It can bury crop straw not only in wet land, but also in dry land. It is suitable for tillage in middle and lower reaches of Yangtze River, where the principal crop rotation is wet land rice after dry land crop annually. Based on our previous research achievements, the cultivator for high stubble returning in paddy field and so on, are widely used. So there are two main kinds of cultivating blades in this rotary tiller. They are rotary blades IIT245 and spiral blades. The former blades are used to cut soil, while the latter blades are to bury straw. The results provide the basis for the structure optimization of the cultivator for straw returning and the improvement of its working performance, and also provide a suitable implement to achieve high stubble straw mulching and soil tillage in paddy field and dry land.
- 17 November 2020
- Published by Wiley in Journal of Food Safety
- Vol. 41 (1)
A rapid detection of Escherichia coli O157:H7 by competition visual antigen macroarray
Pathogenic bacterial contamination is a serious problem for the food industry and in public health. Rapid, accurate and affordable testing for pathogenic bacterial strains is desirable. In this study, a competition visual antigen macroarray (CVAM) for rapid detection of Escherichia coli O157:H7 (E. coli O157:H7) has been developed. This array was able to utilize an HRP‐labeled anti‐E. coli O157:H7 MAb at a concentration of 1:20000 while having a similar sensitivity of 10 5 CFU/ml for E. coli O157:H7 detection as double antibody sandwich array and conventional ELISA. The detection time of CVAM was short as 2 h and can be examined directly by the naked eye. Moreover, there was no cross‐reactivity in the detection of tested in this study. Application of CVAM for the detection of E. coli O157:H7 artificially contaminated milk samples was feasible that showed the antigen array could be applied in the detection of food pathogen infections.
- 17 November 2020
- Published by Wiley in Journal of Food Safety
- Vol. 41 (1)
A rapid detection of Escherichia coli O157:H7 by competition visual antigen macroarray
Pathogenic bacterial contamination is a serious problem for the food industry and in public health. Rapid, accurate and affordable testing for pathogenic bacterial strains is desirable. In this study, a competition visual antigen macroarray (CVAM) for rapid detection of Escherichia coli O157:H7 (E. coli O157:H7) has been developed. This array was able to utilize an HRP‐labeled anti‐E. coli O157:H7 MAb at a concentration of 1:20000 while having a similar sensitivity of 10 5 CFU/ml for E. coli O157:H7 detection as double antibody sandwich array and conventional ELISA. The detection time of CVAM was short as 2 h and can be examined directly by the naked eye. Moreover, there was no cross‐reactivity in the detection of tested in this study. Application of CVAM for the detection of E. coli O157:H7 artificially contaminated milk samples was feasible that showed the antigen array could be applied in the detection of food pathogen infections.