Arwa AlJasser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Arwa AlJasser has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Christopher J. Plack
Manchester Centre for Audiology and Deafness, The University of Manchester, United Kingdom
3 shared publications - Kevin James Munro
Manchester Centre for Audiology and Deafness, University of Manchester, Manchester, UK
3 shared publications - Garreth Prendergast
The University of Manchester
2 shared publications - Adnan M. Shehabi
Department of Audiology and Speech Therapy, Birzeit University, Palestine
1 shared publication - Amani Salem Alqahtani
Saudi Food and Drug Authority, Riyadh 13513, Saudi Arabia
1 shared publication - Hannah Guest
Manchester Centre for Audiology and Deafness, The University of Manchester, United Kingdom
1 shared publication
Latest Publications
- Open Access
- 1 November 2025
- Published by Taylor & Francis in Journal of Multidisciplinary Healthcare
- Vol. ume 18, 7159-7173
Monitoring Ototoxicity in Cancer Patients Undergoing Platinum-Based Chemotherapy and Radiation in Saudi Arabia: Challenges and Solutions
Purpose: Platinum-based chemotherapy and radiotherapy are cornerstone treatments for many cancers but carry a high risk of ototoxicity, leading to hearing loss, tinnitus, and balance dysfunction. Despite the benefits of monitoring in reducing long-term consequences, global uptake remains poor. This study provides the first national-level insight into ototoxicity monitoring for cancer patients in Saudi Arabia, aiming to identify service gaps and propose solutions to guide healthcare planning. Methods: Twenty-five oncology centers were evaluated. Data were collected via phone interviews with oncologists and audiologists, providing a comprehensive understanding of monitoring in clinical practice. Results: Findings highlight a concerning reality: institutions often fail to support even the most basic elements of ototoxicity monitoring. Practices varied considerably in the absence of formal policies, even within the same institution, depending on audiology service availability and oncologists’ referral approaches. Adult referrals were rare, pediatric monitoring was inconsistent, and long-term follow-up was limited. Barriers included inadequate audiological resources, staff shortages, insufficient multidisciplinary coordination, limited audiologists’ knowledge, and lack of guidelines. Conclusion: As decision-makers seek reliable national data to guide policies aligned with Vision 2030 health transformation goals, this study proposes policy-based solutions to strengthen ototoxicity monitoring and expand access to hearing rehabilitation services in Saudi Arabia. The study has inspired a collaborative initiative—currently being explored by the author with audiologists and oncologists across health sectors—to promote internal monitoring protocols in capable institutions and lay the groundwork for a future national ototoxicity monitoring program.
- 1 November 2025
- Published by Taylor & Francis in Journal of Multidisciplinary Healthcare
- Vol. ume 18, 7159-7173
Open AccessMonitoring Ototoxicity in Cancer Patients Undergoing Platinum-Based Chemotherapy and Radiation in Saudi Arabia: Challenges and Solutions
Purpose: Platinum-based chemotherapy and radiotherapy are cornerstone treatments for many cancers but carry a high risk of ototoxicity, leading to hearing loss, tinnitus, and balance dysfunction. Despite the benefits of monitoring in reducing long-term consequences, global uptake remains poor. This study provides the first national-level insight into ototoxicity monitoring for cancer patients in Saudi Arabia, aiming to identify service gaps and propose solutions to guide healthcare planning. Methods: Twenty-five oncology centers were evaluated. Data were collected via phone interviews with oncologists and audiologists, providing a comprehensive understanding of monitoring in clinical practice. Results: Findings highlight a concerning reality: institutions often fail to support even the most basic elements of ototoxicity monitoring. Practices varied considerably in the absence of formal policies, even within the same institution, depending on audiology service availability and oncologists’ referral approaches. Adult referrals were rare, pediatric monitoring was inconsistent, and long-term follow-up was limited. Barriers included inadequate audiological resources, staff shortages, insufficient multidisciplinary coordination, limited audiologists’ knowledge, and lack of guidelines. Conclusion: As decision-makers seek reliable national data to guide policies aligned with Vision 2030 health transformation goals, this study proposes policy-based solutions to strengthen ototoxicity monitoring and expand access to hearing rehabilitation services in Saudi Arabia. The study has inspired a collaborative initiative—currently being explored by the author with audiologists and oncologists across health sectors—to promote internal monitoring protocols in capable institutions and lay the groundwork for a future national ototoxicity monitoring program.
- 2 January 2025
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 68 (1) , 388-398
Online Arabic and English Digits-in-Noise Tests: Effects of Test Language and At-Home Testing
Purpose: The Digits-in-Noise (DIN) test is used widely in research and, increasingly, in remote hearing screening. The reported study aimed to provide basic evaluation data for browser-based DIN software, which allows remote testing without installation of an app. It investigated the effects of test language (Arabic vs. English) and test environment (lab vs. home) on DIN thresholds and test–retest reliability. It also examined the effects of test language on the correlations between DIN and audiometric thresholds. Method: Fifty-two bilingual adults with normal hearing aged 18–35 years completed Arabic and English diotic DIN tests (two sessions in the lab and two sessions at home via the web). Effects of language and environment on DIN thresholds were assessed via paired t tests, while intraclass and Pearson's/Spearman's correlation coefficients quantified test–retest reliability and relations to audiometric thresholds. Results: DIN thresholds were 0.74 dB higher (worse) for Arabic than English stimuli. Thresholds were 0.52 dB lower in the lab than at home, but the effect was not significant after correction for multiple comparisons. Intraclass and Pearson's correlation coefficients were too low for meaningful analysis due to the use of a normal-hearing sample with low between-subject variability in DIN and audiometric thresholds. However, exploratory analysis showed that absolute test–retest differences were low (< 1.2 dB, on average) for both languages and both test environments. Conclusions: Arabic DIN thresholds were a little higher than English thresholds for the same listeners. Employing home-based rather than lab-based testing may slightly elevate DIN thresholds, but the effect was marginal. Nonetheless, both factors should be considered when interpreting DIN data. Test–retest differences were low for both languages and environments. To support hearing screening, subsequent research in audiometrically diverse listeners is required, testing the reliability of DIN thresholds and relations to hearing loss.
- 2 January 2025
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 68 (1) , 388-398
Online Arabic and English Digits-in-Noise Tests: Effects of Test Language and At-Home Testing
Purpose: The Digits-in-Noise (DIN) test is used widely in research and, increasingly, in remote hearing screening. The reported study aimed to provide basic evaluation data for browser-based DIN software, which allows remote testing without installation of an app. It investigated the effects of test language (Arabic vs. English) and test environment (lab vs. home) on DIN thresholds and test–retest reliability. It also examined the effects of test language on the correlations between DIN and audiometric thresholds. Method: Fifty-two bilingual adults with normal hearing aged 18–35 years completed Arabic and English diotic DIN tests (two sessions in the lab and two sessions at home via the web). Effects of language and environment on DIN thresholds were assessed via paired t tests, while intraclass and Pearson's/Spearman's correlation coefficients quantified test–retest reliability and relations to audiometric thresholds. Results: DIN thresholds were 0.74 dB higher (worse) for Arabic than English stimuli. Thresholds were 0.52 dB lower in the lab than at home, but the effect was not significant after correction for multiple comparisons. Intraclass and Pearson's correlation coefficients were too low for meaningful analysis due to the use of a normal-hearing sample with low between-subject variability in DIN and audiometric thresholds. However, exploratory analysis showed that absolute test–retest differences were low (< 1.2 dB, on average) for both languages and both test environments. Conclusions: Arabic DIN thresholds were a little higher than English thresholds for the same listeners. Employing home-based rather than lab-based testing may slightly elevate DIN thresholds, but the effect was marginal. Nonetheless, both factors should be considered when interpreting DIN data. Test–retest differences were low for both languages and environments. To support hearing screening, subsequent research in audiometrically diverse listeners is required, testing the reliability of DIN thresholds and relations to hearing loss.
- Open Access
Determinants of Vaccine Hesitancy among Home Health Care Service Recipients in Saudi Arabia
Background: Vaccine hesitancy has been identified by the World Health Organization (WHO) as a major worldwide health threat. Home Health Care (HHC) service recipients represent a vulnerable group and were prioritized to receive coronavirus disease (COVID-19) vaccination during the national vaccine campaigns in Saudi Arabia. We aimed to investigate the most frequent reasons for vaccine hesitancy among home health care recipients in Saudi Arabia. Methods: This cross-sectional survey was conducted among home health care (HHC) service recipients in Saudi Arabia from February 2022 to September 2022. The behavioral and social drivers (BeSD) model developed by the WHO was used to understand the factors affecting vaccination decision making in our cohort. Results: Of the 426 HHC service recipients enrolled in the study, a third were hesitant to complete the COVID-19 vaccination series. The most prevalent reported reason for COVID-19 vaccine refusal was concerns about the vaccine side effects (41.6%). Factors independently associated with COVID-19 vaccination hesitancy were: having chronic conditions (odds ratio [OR] = 2.59; 95% confidence interval [CI] = 1.33–5.05, p = 0.005), previous COVID-19 diagnosis (OR = 0.48; 95% CI: 0.28–0.82, p = 0.008), ease of getting the COVID-19 vaccine by themselves (OR = 0.49; 95% CI: 0.28–0.89, p = 0.018), belief in the importance of COVID-19 vaccine in protecting their health (OR = 0.60; 95% CI: 0.38–0.96, p = 0.032), and confidence in the safety of COVID-19 vaccination (OR = 0.38; 95% CI: 0.21–0.69, p = 0.001). Conclusion: Only one-third of the study participants were hesitant to complete the series of COVID-19 vaccination. Understanding the factors underpinning vaccine hesitancy among this group would help healthcare workers and policymakers in developing personalized health awareness campaigns aimed at improving vaccine acceptance levels.
Open AccessDeterminants of Vaccine Hesitancy among Home Health Care Service Recipients in Saudi Arabia
Background: Vaccine hesitancy has been identified by the World Health Organization (WHO) as a major worldwide health threat. Home Health Care (HHC) service recipients represent a vulnerable group and were prioritized to receive coronavirus disease (COVID-19) vaccination during the national vaccine campaigns in Saudi Arabia. We aimed to investigate the most frequent reasons for vaccine hesitancy among home health care recipients in Saudi Arabia. Methods: This cross-sectional survey was conducted among home health care (HHC) service recipients in Saudi Arabia from February 2022 to September 2022. The behavioral and social drivers (BeSD) model developed by the WHO was used to understand the factors affecting vaccination decision making in our cohort. Results: Of the 426 HHC service recipients enrolled in the study, a third were hesitant to complete the COVID-19 vaccination series. The most prevalent reported reason for COVID-19 vaccine refusal was concerns about the vaccine side effects (41.6%). Factors independently associated with COVID-19 vaccination hesitancy were: having chronic conditions (odds ratio [OR] = 2.59; 95% confidence interval [CI] = 1.33–5.05, p = 0.005), previous COVID-19 diagnosis (OR = 0.48; 95% CI: 0.28–0.82, p = 0.008), ease of getting the COVID-19 vaccine by themselves (OR = 0.49; 95% CI: 0.28–0.89, p = 0.018), belief in the importance of COVID-19 vaccine in protecting their health (OR = 0.60; 95% CI: 0.38–0.96, p = 0.032), and confidence in the safety of COVID-19 vaccination (OR = 0.38; 95% CI: 0.21–0.69, p = 0.001). Conclusion: Only one-third of the study participants were hesitant to complete the series of COVID-19 vaccination. Understanding the factors underpinning vaccine hesitancy among this group would help healthcare workers and policymakers in developing personalized health awareness campaigns aimed at improving vaccine acceptance levels.
- 29 June 2022
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 62 (9) , 853-858
Establishing the reliability and the validity of the Arabic translated versions of the Effort Assessment Scale and the Fatigue Assessment Scale
The aim was to establish the reliability and the validity of Arabic translated versions of the Fatigue Assessment Scale (FAS) and the Effort Assessment Scale (EAS).The FAS and the EAS were translat...
- 29 June 2022
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 62 (9) , 853-858
Establishing the reliability and the validity of the Arabic translated versions of the Effort Assessment Scale and the Fatigue Assessment Scale
The aim was to establish the reliability and the validity of Arabic translated versions of the Fatigue Assessment Scale (FAS) and the Effort Assessment Scale (EAS).The FAS and the EAS were translat...
- Open Access
- 9 August 2021
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 61 (10) , 832-840
Is COVID-19 associated with self-reported audio-vestibular symptoms?
To determine if a positive test for COVID-19 is associated with self-reported audio-vestibular symptoms.Self-reported changes in hearing, tinnitus, hyperacusis, and dizziness/rotatory vertigo were ...
- 9 August 2021
- Published by Taylor & Francis in International Journal of Audiology
- Vol. 61 (10) , 832-840
Open AccessIs COVID-19 associated with self-reported audio-vestibular symptoms?
To determine if a positive test for COVID-19 is associated with self-reported audio-vestibular symptoms.Self-reported changes in hearing, tinnitus, hyperacusis, and dizziness/rotatory vertigo were ...
- Open Access
- 28 August 2019
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 41 (3) , 561-575
Subclinical Auditory Neural Deficits in Patients With Type 1 Diabetes Mellitus
Objectives: Diabetes mellitus (DM) is associated with a variety of sensory complications. Very little attention has been given to auditory neuropathic complications in DM. The aim of this study was to determine whether type 1 DM (T1DM) affects neural coding of the rapid temporal fluctuations of sounds, and how any deficits may impact on behavioral performance. Design: Participants were 30 young normal-hearing T1DM patients, and 30 age-, sex-, and audiogram-matched healthy controls. Measurements included electrophysiological measures of auditory nerve and brainstem function using the click-evoked auditory brainstem response, and of brainstem neural temporal coding using the sustained frequency-following response (FFR); behavioral tests of temporal coding (interaural phase difference discrimination and the frequency difference limen); tests of speech perception in noise; and self-report measures of auditory disability using the Speech, Spatial and Qualities of Hearing Scale. Results: There were no significant differences between T1DM patients and controls in the auditory brainstem response. However, the T1DM group showed significantly reduced FFRs to both temporal envelope and temporal fine structure. The T1DM group also showed significantly higher interaural phase difference and frequency difference limen thresholds, worse speech-in-noise performance, as well as lower overall Speech, Spatial and Qualities scores than the control group. Conclusions: These findings suggest that T1DM is associated with degraded neural temporal coding in the brainstem in the absence of an elevation in audiometric threshold, and that the FFR may provide an early indicator of neural damage in T1DM, before any abnormalities can be identified using standard clinical tests. However, the relation between the neural deficits and the behavioral deficits is uncertain.
- 28 August 2019
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 41 (3) , 561-575
Open AccessSubclinical Auditory Neural Deficits in Patients With Type 1 Diabetes Mellitus
Objectives: Diabetes mellitus (DM) is associated with a variety of sensory complications. Very little attention has been given to auditory neuropathic complications in DM. The aim of this study was to determine whether type 1 DM (T1DM) affects neural coding of the rapid temporal fluctuations of sounds, and how any deficits may impact on behavioral performance. Design: Participants were 30 young normal-hearing T1DM patients, and 30 age-, sex-, and audiogram-matched healthy controls. Measurements included electrophysiological measures of auditory nerve and brainstem function using the click-evoked auditory brainstem response, and of brainstem neural temporal coding using the sustained frequency-following response (FFR); behavioral tests of temporal coding (interaural phase difference discrimination and the frequency difference limen); tests of speech perception in noise; and self-report measures of auditory disability using the Speech, Spatial and Qualities of Hearing Scale. Results: There were no significant differences between T1DM patients and controls in the auditory brainstem response. However, the T1DM group showed significantly reduced FFRs to both temporal envelope and temporal fine structure. The T1DM group also showed significantly higher interaural phase difference and frequency difference limen thresholds, worse speech-in-noise performance, as well as lower overall Speech, Spatial and Qualities scores than the control group. Conclusions: These findings suggest that T1DM is associated with degraded neural temporal coding in the brainstem in the absence of an elevation in audiometric threshold, and that the FFR may provide an early indicator of neural damage in T1DM, before any abnormalities can be identified using standard clinical tests. However, the relation between the neural deficits and the behavioral deficits is uncertain.