Lin Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lin Yang has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
- Heidrun Wabnitz
Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
5 shared publications - Antonio Pifferi
Politecnico di Milano
3 shared publications Dirk Grosenick
Phys Tech Bundesanstalt PTB, Abbestr 2-12, D-10587 Berlin, Germany
3 shared publications- Dirk Grosenick
Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany
3 shared publications - Aleh Sudakou
Nalecz Institute of Biocybernetics and Biomedical Engineering, Polish Academy of Sciences, Warsaw, Poland
2 shared publications - Alessandro Torricelli
Politecnico di Milano, Dipartimento di Fisica, Milano, Italy
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (09) , 1-18
Generalized self-calibrating probe approach for CW tissue oximetry
SignificanceFunctional near-infrared spectroscopy (fNIRS) and oximetry are important noninvasive methods to investigate physiological processes and states in the human brain and muscle tissue. Self-calibrating probe methods combine two light sources with typically two detectors to improve the stability of continuous-wave (CW) devices, but so far are limited to fully symmetric geometries.AimWe developed a generalized self-calibrating probe approach to improve accuracy and stability in CW oximetry for arbitrary configurations of two light sources and detectors.ApproachWe used the diffusion theory of light transport to derive the effective attenuation coefficient from self-calibrating probes with arbitrary asymmetric source-detector configurations in reflection. The theory was validated by measurements on tissue-like reference phantoms and by a vascular occlusion test on the forearm muscle of a healthy subject using a dual-wavelength CW fNIRS imager. Results were compared with conventional analysis by spatially resolved spectroscopy (SRS). Time-domain measurements served as a reference.ResultsThe phantom studies with the generalized self-calibrating probe approach provided accurate results for effective attenuation and oxygen saturation for the wide variety of source-detector configurations examined. Results from the SRS method showed a slightly larger spread. When submillimeter shifts of the source positions were neglected in the data analysis, large errors were observed in oxygen saturation for both methods. The vascular occlusion test showed good agreement between the self-calibrating approach and the time-domain reference data. Oxygenation profiles from SRS differed strongly across the source-detector combinations, with significant deviations already for the baseline saturation. When CW measurements were analyzed using literature values for the tissue scattering properties, systematic shifts of the oxygen saturation occured. The shifts remain small when the ratio of the reduced scattering coefficients at the two wavelengths of the CW device is close to the true tissue value.ConclusionsThe proposed generalized self-calibrating approach enables quantification of oxygen saturation in vivo for a wide variety of source-detector configurations whereby a good estimate of the ratio of the tissue scattering properties at the two wavelengths is required. Our single-case study shows the potential of the self-calibrating approach to considerably improve the accuracy and stability of CW oximetry for the large dynamic range of a vascular occlusion compared with conventional measurements using SRS with a single light source.
- 1 September 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 31 (09) , 1-18
Open AccessGeneralized self-calibrating probe approach for CW tissue oximetry
SignificanceFunctional near-infrared spectroscopy (fNIRS) and oximetry are important noninvasive methods to investigate physiological processes and states in the human brain and muscle tissue. Self-calibrating probe methods combine two light sources with typically two detectors to improve the stability of continuous-wave (CW) devices, but so far are limited to fully symmetric geometries.AimWe developed a generalized self-calibrating probe approach to improve accuracy and stability in CW oximetry for arbitrary configurations of two light sources and detectors.ApproachWe used the diffusion theory of light transport to derive the effective attenuation coefficient from self-calibrating probes with arbitrary asymmetric source-detector configurations in reflection. The theory was validated by measurements on tissue-like reference phantoms and by a vascular occlusion test on the forearm muscle of a healthy subject using a dual-wavelength CW fNIRS imager. Results were compared with conventional analysis by spatially resolved spectroscopy (SRS). Time-domain measurements served as a reference.ResultsThe phantom studies with the generalized self-calibrating probe approach provided accurate results for effective attenuation and oxygen saturation for the wide variety of source-detector configurations examined. Results from the SRS method showed a slightly larger spread. When submillimeter shifts of the source positions were neglected in the data analysis, large errors were observed in oxygen saturation for both methods. The vascular occlusion test showed good agreement between the self-calibrating approach and the time-domain reference data. Oxygenation profiles from SRS differed strongly across the source-detector combinations, with significant deviations already for the baseline saturation. When CW measurements were analyzed using literature values for the tissue scattering properties, systematic shifts of the oxygen saturation occured. The shifts remain small when the ratio of the reduced scattering coefficients at the two wavelengths of the CW device is close to the true tissue value.ConclusionsThe proposed generalized self-calibrating approach enables quantification of oxygen saturation in vivo for a wide variety of source-detector configurations whereby a good estimate of the ratio of the tissue scattering properties at the two wavelengths is required. Our single-case study shows the potential of the self-calibrating approach to considerably improve the accuracy and stability of CW oximetry for the large dynamic range of a vascular occlusion compared with conventional measurements using SRS with a single light source.
- Open Access
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (04) , 1-20
Phantom for standardization in functional near-infrared spectroscopy, part 1: implementation and usage
SignificanceThe use of functional near-infrared spectroscopy (fNIRS) is expanding, including examples of devices approved for routine clinical use for specific indications. Instrument standardization is a critical element to facilitate clinical adoption. Currently, there is no published description of a phantom that meets the requirements of IEC 80601-2-71, the IEC/ISO standard for fNIRS equipment.AimWe report an example of the implementation of the fNIRS standard phantom described in IEC 80601-2-71. We further report results from measurement campaigns with this phantom prototype in Japan and Europe.ApproachA phantom prototype was built and circulated among multiple academic and commercial fNIRS groups with diverse instrumentation. The phantom prototype was characterized by wavelength-dependent measurements of its diffuse optical features and utilized in a test for fNIRS signal magnitude as described in IEC 80601-2-71.ResultsThe optical loss of this phantom prototype as well as its change by varying an internal aperture were found to be ∼40 dB and between 3.5 and 3.6 dB, respectively. The test for fNIRS signal magnitude based on this phantom was successfully carried out on various commercial fNIRS devices.ConclusionsThe characteristics of the phantom prototype agreed with the specifications in the standard. The phantom prototype proved suitable for the related test in IEC 80601-2-71.
- 1 October 2025
- Published by SPIE-Intl Soc Optical Eng in Neurophotonics
- Vol. 12 (04) , 1-20
Open AccessPhantom for standardization in functional near-infrared spectroscopy, part 1: implementation and usage
SignificanceThe use of functional near-infrared spectroscopy (fNIRS) is expanding, including examples of devices approved for routine clinical use for specific indications. Instrument standardization is a critical element to facilitate clinical adoption. Currently, there is no published description of a phantom that meets the requirements of IEC 80601-2-71, the IEC/ISO standard for fNIRS equipment.AimWe report an example of the implementation of the fNIRS standard phantom described in IEC 80601-2-71. We further report results from measurement campaigns with this phantom prototype in Japan and Europe.ApproachA phantom prototype was built and circulated among multiple academic and commercial fNIRS groups with diverse instrumentation. The phantom prototype was characterized by wavelength-dependent measurements of its diffuse optical features and utilized in a test for fNIRS signal magnitude as described in IEC 80601-2-71.ResultsThe optical loss of this phantom prototype as well as its change by varying an internal aperture were found to be ∼40 dB and between 3.5 and 3.6 dB, respectively. The test for fNIRS signal magnitude based on this phantom was successfully carried out on various commercial fNIRS devices.ConclusionsThe characteristics of the phantom prototype agreed with the specifications in the standard. The phantom prototype proved suitable for the related test in IEC 80601-2-71.
- Open Access
- 28 November 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12765, 22-95
Tailoring freeform beam-shaping lenses for edge-emitting lasers
The edge-emitting laser diodes (EELs) are widely used due to their superior performance, however, the strongly asymmetric beam profile along the fast and slow axes presents a big challenge in the beam shaping of EEL. Traditional optical devices mainly focus on adjusting the asymmetric divergence angle of the fast and slow axes of the EEL, and it is difficult to achieve flexible and precise control of the luminous distribution of the EEL due to the limited freedom of the conventional beam-shaping elements. In this article, we employ freeform lenses to flexibly reshape EEL beams and develop an approach to tackle the obstacles caused by the strongly asymmetric beam profile by generalizing the Monge– Ampère method to tailor freeform beam-shaping lenses for EELs. Three typical but challenging beam-shaping tasks show that both the intensity and wavefront of an EEL beam can be reshaped in a desired manner by the use of a single compact freeform lens without any symmetric restrictions on the architecture of the beam-shaping system.
- 28 November 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12765, 22-95
Open AccessTailoring freeform beam-shaping lenses for edge-emitting lasers
The edge-emitting laser diodes (EELs) are widely used due to their superior performance, however, the strongly asymmetric beam profile along the fast and slow axes presents a big challenge in the beam shaping of EEL. Traditional optical devices mainly focus on adjusting the asymmetric divergence angle of the fast and slow axes of the EEL, and it is difficult to achieve flexible and precise control of the luminous distribution of the EEL due to the limited freedom of the conventional beam-shaping elements. In this article, we employ freeform lenses to flexibly reshape EEL beams and develop an approach to tackle the obstacles caused by the strongly asymmetric beam profile by generalizing the Monge– Ampère method to tailor freeform beam-shaping lenses for EELs. Three typical but challenging beam-shaping tasks show that both the intensity and wavefront of an EEL beam can be reshaped in a desired manner by the use of a single compact freeform lens without any symmetric restrictions on the architecture of the beam-shaping system.
- Open Access
- 15 June 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (07) , 074716-27
Multi-laboratory performance assessment of diffuse optics instruments: the BitMap exercise
Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.
- 15 June 2022
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 27 (07) , 074716-27
Open AccessMulti-laboratory performance assessment of diffuse optics instruments: the BitMap exercise
Diffuse optics (DO) encompasses a range of photonics tools based on the study of random photon migration in highly scattering media—biological tissues in particular. Due to its unique features, DO is emerging as a powerful means for clinical or homecare diagnostics.1 The basic physics of DO is related to the detection of temporal or spatial alteration in photon distribution re-emitted on the tissue surface.2 Due to the low power (typically few mW) of injected near-infrared light (600- to 1100-nm range), DO is inherently noninvasive. The photon temporal (or spatial) distribution carries information on the absorption—ultimately related to tissue chemical composition, such as water, lipid, collagen content, oxy- and deoxy-hemoglobin concentration, cytochrome c-oxidase3—and scattering properties—linked to tissue microstructure. Further, DO is one of the few noninvasive modalities capable of providing functional information, e.g., brain or muscle activation.4 It can be operated noncontact through remote light illumination and collection.5 It explores the tissue well below the skin at depths of up to 2 to 4 cm. It can provide quantitative operator-independent assessment of the tissue status, such as hemoglobin oxygenation level in the brain. Finally, it is highly scalable, sharing the same technology from large clinical tomographic systems down to wearable devices or homecare appliances.6 For all these aspects, DO is attracting more and more interest in many fields, such as monitoring vital signs like brain oxygenation in critical care or during interventions,7 tumor diagnostics as for breast cancer,8 investigating the impact of lifestyle and nutrition on our body,9 or other fields such as neuroscience and psychology,10 sports, and leisure.11 Even further, the operator independence, the depth sensitivity, and the scalability in addition to noninvasiveness make this option attractive for telemedicine and homecare of patients remotely.
- 21 October 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (11) , 6570-6589
Space-enhanced time-domain diffuse optics for determination of tissue optical properties in two-layered structures
A novel methodology for solving the inverse problem of diffuse optics for two-layered structures is proposed to retrieve the absolute quantities of optical absorption and reduced scattering coefficients of the layers simultaneously. A liquid phantom with various optical absorption properties in the deep layer is prepared and experimentally investigated using the space-enhanced time-domain method. Monte-Carlo simulations are applied to analyze the different measurements in time domain, space domain, and by the new methodology. The deviations of retrieved values from nominal values of both layers’ optical properties are simultaneously reduced to a very low extent compared to the single-domain methods. The reliability and uncertainty of the retrieval performance are also considerably improved by the new methodology. It is observed in time-domain analyses that for the deep layer the retrieval of absorption coefficient is almost not affected by the scattering properties and this kind of “deep scattering neutrality” is investigated and overcome as well.
- 21 October 2020
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 11 (11) , 6570-6589
Space-enhanced time-domain diffuse optics for determination of tissue optical properties in two-layered structures
A novel methodology for solving the inverse problem of diffuse optics for two-layered structures is proposed to retrieve the absolute quantities of optical absorption and reduced scattering coefficients of the layers simultaneously. A liquid phantom with various optical absorption properties in the deep layer is prepared and experimentally investigated using the space-enhanced time-domain method. Monte-Carlo simulations are applied to analyze the different measurements in time domain, space domain, and by the new methodology. The deviations of retrieved values from nominal values of both layers’ optical properties are simultaneously reduced to a very low extent compared to the single-domain methods. The reliability and uncertainty of the retrieval performance are also considerably improved by the new methodology. It is observed in time-domain analyses that for the deep layer the retrieval of absorption coefficient is almost not affected by the scattering properties and this kind of “deep scattering neutrality” is investigated and overcome as well.
- 4 September 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (19) , 26415-26431
Spatially-enhanced time-domain NIRS for accurate determination of tissue optical properties
A multivariate method integrating time and space resolved techniques of near-infrared spectroscopy is proposed for simultaneously retrieving the absolute quantities of optical absorption and scattering properties in tissues. The time-domain feature of photon migration is advantageously constrained and regularized by its spatially-resolved amplitude patterns in the inverse procedure. Measurements of tissue-mimicking phantoms with various optical properties are analyzed with Monte-Carlo simulations to validate the method performance. The uniqueness, stability, and uncertainty of the method are discussed.
- 4 September 2019
- Published by Optica Publishing Group in Optics Express
- Vol. 27 (19) , 26415-26431
Spatially-enhanced time-domain NIRS for accurate determination of tissue optical properties
A multivariate method integrating time and space resolved techniques of near-infrared spectroscopy is proposed for simultaneously retrieving the absolute quantities of optical absorption and scattering properties in tissues. The time-domain feature of photon migration is advantageously constrained and regularized by its spatially-resolved amplitude patterns in the inverse procedure. Measurements of tissue-mimicking phantoms with various optical properties are analyzed with Monte-Carlo simulations to validate the method performance. The uniqueness, stability, and uncertainty of the method are discussed.