Alessandro Ruocco
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alessandro Ruocco has a total of 217 co-authors. Here are the top co-authors by number of shared publications:
- Alice Apponi
INFN Sezione di Roma Tre
15 shared publications - Carlo Mariani
INFN Sezione di Roma
11 shared publications - Francesco Pandolfi
INFN Sezione di Roma
11 shared publications - Gianluca Cavoto
Sapienza Università di Roma
10 shared publications - Ilaria Rago
INFN Sezione di Roma, Piazzale Aldo Moro 2, 00185 Rome, Italy
9 shared publications - Orlando Castellano
Università degli Studi di Roma Tre
8 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (19)
Graphene lattice recoil in hard x-ray photoemission: Experiment and theory
Hard-x-ray C 1 s photoemission from monolayer graphene probes a regime in which nuclear recoil and intrinsic electronic asymmetry contribute on comparable energy scales to the observed spectral line shape. Here we combine experiment and modeling over the photon-energy range 0.8 – 8 keV to resolve this interplay quantitatively. A graphene-specific implementation of the Fujikawa-Takata cumulant formalism, based on an anisotropic vibrational density of states constrained by first-principles phonon calculations, captures the expected recoil scaling with photon energy and emission geometry but fails to reproduce the pronounced asymmetric tails of the measured spectra. To overcome this limitation, we introduce an explicit electronic convolution model in which a photon-energy-independent reference response, dominated by the electronic line shape and extracted from the low-recoil 0.8 keV data through a recoil-inclusive fit, is convolved with a phonon recoil kernel carrying the full dependence on photon energy and emission angle. This approach reproduces both the measured line-shape evolution and the observed peak shifts across the explored energy range without refitting the spectra at higher photon energies. The results show that recoil in graphene cannot be described by a baseline treatment in which the phonon recoil kernel is combined only with symmetric lifetime broadening, but must be treated together with the intrinsic many-body electronic response of the C 1 s line.
- 27 October 2026
- Published by American Physical Society (APS) in Physical Review B
- Vol. 114 (19)
Open AccessGraphene lattice recoil in hard x-ray photoemission: Experiment and theory
Hard-x-ray C 1 s photoemission from monolayer graphene probes a regime in which nuclear recoil and intrinsic electronic asymmetry contribute on comparable energy scales to the observed spectral line shape. Here we combine experiment and modeling over the photon-energy range 0.8 – 8 keV to resolve this interplay quantitatively. A graphene-specific implementation of the Fujikawa-Takata cumulant formalism, based on an anisotropic vibrational density of states constrained by first-principles phonon calculations, captures the expected recoil scaling with photon energy and emission geometry but fails to reproduce the pronounced asymmetric tails of the measured spectra. To overcome this limitation, we introduce an explicit electronic convolution model in which a photon-energy-independent reference response, dominated by the electronic line shape and extracted from the low-recoil 0.8 keV data through a recoil-inclusive fit, is convolved with a phonon recoil kernel carrying the full dependence on photon energy and emission angle. This approach reproduces both the measured line-shape evolution and the observed peak shifts across the explored energy range without refitting the spectra at higher photon energies. The results show that recoil in graphene cannot be described by a baseline treatment in which the phonon recoil kernel is combined only with symmetric lifetime broadening, but must be treated together with the intrinsic many-body electronic response of the C 1 s line.
- Open Access
- 21 September 2026
- Published by Elsevier in Applied Surface Science
- Vol. 753
A wide optical-gap in fully sp3-like hydrogenated monolayer graphene
- 21 September 2026
- Published by Elsevier in Applied Surface Science
- Vol. 753
Open AccessA wide optical-gap in fully sp3-like hydrogenated monolayer graphene
- Open Access
- 9 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Toward high-resolution low-energy electron spectroscopy with transition-edge sensors
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.
- 9 September 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 26 (3)
Open AccessToward high-resolution low-energy electron spectroscopy with transition-edge sensors
We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100-eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of ( 60 × 60 ) μ m 2 and a critical temperature of approximately 80 mK . The electron source is based on vertically aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the ( 92 – 99 ) eV kinetic energy range, we obtain a Gaussian energy resolution for fully absorbed electrons of ( 0.48 ± 0.04 ± 0.06 ) eV , where the first uncertainty is statistical and the second systematic. When considering the full-width at half-maximum of the peak of the signal amplitude distribution, the corresponding resolution is of ( 1.4 ± 0.2 ± 0.3 ) eV . The former represents an improvement of ( 47 – 60 ) % with respect to previous results and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 21 and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.
- Open Access
- 24 February 2026
- Published by Elsevier in SSRN Electronic Journal
A Wide Optical-Gap in Fully sp3-Like Hydrogenated Monolayer Graphene
A comprehensive spectroscopic characterisation of two highly hydrogenated monolayer graphene samples transferred onto nickel grids is reported. With X ray photoemission spectroscopy on the C 1s core-level, a 100$\%$ $sp^3$ profile was observed upon hydrogenation of a more $sp^3$-like initially defected graphene, while a flatter, more $sp^2$-arranged, graphene reached a 62$\%$ $sp^3$ saturation. Low-energy reflection electron energy-loss spectroscopy (EELS) corroborates these findings through the $\pi$-plasmon excitation quenching for the fully $sp^3$ sample and a significant reduction for the partially converted one. The extreme surface sensitivity of low-energy reflection EELS enables extraction of the optical band gap of the hydrogenated layer even on a metallic support, yielding values of 6.3 and 6.2 eV for the two samples. The C--H stretching vibrational mode is also resolved, providing a direct fingerprint of graphene--hydrogen bonding. Finally, valence-band measurements of the $62\%$ saturated sample suggest the coexistence of one-sided and two-sided hydrogenation morphologies.- 24 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessA Wide Optical-Gap in Fully sp3-Like Hydrogenated Monolayer Graphene
A comprehensive spectroscopic characterisation of two highly hydrogenated monolayer graphene samples transferred onto nickel grids is reported. With X ray photoemission spectroscopy on the C 1s core-level, a 100$\%$ $sp^3$ profile was observed upon hydrogenation of a more $sp^3$-like initially defected graphene, while a flatter, more $sp^2$-arranged, graphene reached a 62$\%$ $sp^3$ saturation. Low-energy reflection electron energy-loss spectroscopy (EELS) corroborates these findings through the $\pi$-plasmon excitation quenching for the fully $sp^3$ sample and a significant reduction for the partially converted one. The extreme surface sensitivity of low-energy reflection EELS enables extraction of the optical band gap of the hydrogenated layer even on a metallic support, yielding values of 6.3 and 6.2 eV for the two samples. The C--H stretching vibrational mode is also resolved, providing a direct fingerprint of graphene--hydrogen bonding. Finally, valence-band measurements of the $62\%$ saturated sample suggest the coexistence of one-sided and two-sided hydrogenation morphologies. - Open Access
Liquid‐Processed 2D Aromatic Amorphous Carbon: Defect Engineering and Universal Transport Scaling
Liquid‐processed 2D aromatic amorphous carbons are emerging as a new materials platform in which distorted sp 2 networks combine scalability with unconventional electronic transport. Here, we report a deterministic pathway to produce graphene‐derived amorphous 2D carbon thin films by combining the water processability of graphene oxide with rapid thermal quenching. During heating, the stepwise removal of oxygen groups generates vacancies and topological defects; rapid traversal of this regime prevents structural recovery and yields a kinetically trapped quasi‐amorphous phase, termed quenched reduced graphene oxide (qRGO). XPS and UPS confirm that qRGO maintains predominantly sp 2 bonding, indicating a distorted aromatic network rather than a transition to sp 3 ‐rich amorphous carbon. Correlative structural and spectroscopic analyses reveal suppressed long‐range order and boundary‐like defect character in qRGO, contrasting with the vacancy‐type defects of nanocrystalline reduced graphene oxide (RGO). Transport measurements show that RGO retains partial coherence and weak localization, whereas qRGO evolves into a strongly disordered regime governed by variable‐range hopping. Despite these differences, both systems collapse onto a universal power‐law scaling of resistivity. These results demonstrate that thermal‐kinetic control of oxygen‐driven defect formation provides a scalable route to functional 2D amorphous carbon films.
Open AccessLiquid‐Processed 2D Aromatic Amorphous Carbon: Defect Engineering and Universal Transport Scaling
Liquid‐processed 2D aromatic amorphous carbons are emerging as a new materials platform in which distorted sp 2 networks combine scalability with unconventional electronic transport. Here, we report a deterministic pathway to produce graphene‐derived amorphous 2D carbon thin films by combining the water processability of graphene oxide with rapid thermal quenching. During heating, the stepwise removal of oxygen groups generates vacancies and topological defects; rapid traversal of this regime prevents structural recovery and yields a kinetically trapped quasi‐amorphous phase, termed quenched reduced graphene oxide (qRGO). XPS and UPS confirm that qRGO maintains predominantly sp 2 bonding, indicating a distorted aromatic network rather than a transition to sp 3 ‐rich amorphous carbon. Correlative structural and spectroscopic analyses reveal suppressed long‐range order and boundary‐like defect character in qRGO, contrasting with the vacancy‐type defects of nanocrystalline reduced graphene oxide (RGO). Transport measurements show that RGO retains partial coherence and weak localization, whereas qRGO evolves into a strongly disordered regime governed by variable‐range hopping. Despite these differences, both systems collapse onto a universal power‐law scaling of resistivity. These results demonstrate that thermal‐kinetic control of oxygen‐driven defect formation provides a scalable route to functional 2D amorphous carbon films.
- 20 December 2025
- Published by Elsevier in Applied Surface Science
- Vol. 723
Stability of highly hydrogenated monolayer graphene in ultra-high vacuum and in air
- 20 December 2025
- Published by Elsevier in Applied Surface Science
- Vol. 723
Stability of highly hydrogenated monolayer graphene in ultra-high vacuum and in air
- 3 September 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (36) , 21260-21267
Quantitative correlation between carbon nanotube tip morphology and field emission properties at cryogenic temperature
We present a thorough analysis of the field emission properties of three varieties of vertically aligned carbon nanotubes (VA-CNTs), characterized by different morphologies as a consequence of different post-growth plasma etching treatments. Following the Fowler–Nordheim theory on field emission, we have determined the field enhancement factor β of the samples thanks to a precise measurement of their work function through ultraviolet photoemission spectroscopy, and through the study of the emitted electron current at a temperature of T = 2.8 K. We find that plasma etching has the effect of significantly increasing the β of the samples, reaching a high value of β = (15.2 ± 2.5) × 103 for the sample treated with the strongest etching. We have furthermore studied the morphology of the samples with an atomic force microscope (AFM), and measured the mean radius of curvature of the emitting tips, rc. We have found a relationship of the form β(rc) = k/rc, with k = (175 ± 13) μm, which allows prediction of the field-emission properties of a VA-CNT sample through a simple AFM scan.
- 3 September 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 17 (36) , 21260-21267
Quantitative correlation between carbon nanotube tip morphology and field emission properties at cryogenic temperature
We present a thorough analysis of the field emission properties of three varieties of vertically aligned carbon nanotubes (VA-CNTs), characterized by different morphologies as a consequence of different post-growth plasma etching treatments. Following the Fowler–Nordheim theory on field emission, we have determined the field enhancement factor β of the samples thanks to a precise measurement of their work function through ultraviolet photoemission spectroscopy, and through the study of the emitted electron current at a temperature of T = 2.8 K. We find that plasma etching has the effect of significantly increasing the β of the samples, reaching a high value of β = (15.2 ± 2.5) × 103 for the sample treated with the strongest etching. We have furthermore studied the morphology of the samples with an atomic force microscope (AFM), and measured the mean radius of curvature of the emitting tips, rc. We have found a relationship of the form β(rc) = k/rc, with k = (175 ± 13) μm, which allows prediction of the field-emission properties of a VA-CNT sample through a simple AFM scan.
- 15 May 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (19)
Atomic deuterium bonding to multi-walled carbon nano tubes
Atomic deuterium adsorption on multi-walled carbon nanotubes (MWCNTs) has been achieved with a high deuteration level (≃70% of deuterated carbon atoms), and studied using complementary spectroscopic techniques, namely, photoelectron spectroscopy and Raman spectroscopy. As a consequence of the deuterium (D) adsorption on the MWCNTs, the sp2 bonds of the C atoms are distorted toward an sp3 configuration, and the π plasmon excitation of the metallic MWCNTs is quenched, suggesting the transition to a semiconducting phase. Such a controlled deuteration in ultra-high vacuum conditions induces the opening of an energy gap in the metallic MWCNTs, with the valence band maximum at about ∼3.1 eV below the Fermi level. The bond distortion and the strain induced by the D uptake is evidenced by the modification of the Raman response. This work shows that the molecular cracking of D2 in ultra-high vacuum is an efficient way to obtain stable, homogeneous, and high uptake of deuterium atoms with minimal presence of defects.
- 15 May 2025
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 162 (19)
Atomic deuterium bonding to multi-walled carbon nano tubes
Atomic deuterium adsorption on multi-walled carbon nanotubes (MWCNTs) has been achieved with a high deuteration level (≃70% of deuterated carbon atoms), and studied using complementary spectroscopic techniques, namely, photoelectron spectroscopy and Raman spectroscopy. As a consequence of the deuterium (D) adsorption on the MWCNTs, the sp2 bonds of the C atoms are distorted toward an sp3 configuration, and the π plasmon excitation of the metallic MWCNTs is quenched, suggesting the transition to a semiconducting phase. Such a controlled deuteration in ultra-high vacuum conditions induces the opening of an energy gap in the metallic MWCNTs, with the valence band maximum at about ∼3.1 eV below the Fermi level. The bond distortion and the strain induced by the D uptake is evidenced by the modification of the Raman response. This work shows that the molecular cracking of D2 in ultra-high vacuum is an efficient way to obtain stable, homogeneous, and high uptake of deuterium atoms with minimal presence of defects.
- Open Access
- 29 October 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (4)
Detection of low-energy electrons with transition-edge sensors
We present the detection of electrons with kinetic energy in the 100 eV range with transition-edge sensors (TESs). This has been achieved with a ( 100 × 100 ) - μ m 2 Ti/Au bilayer TES, with a critical temperature of about 84 mK. The electrons are produced directly in the cryostat by an innovative cold source based on field emission from vertically aligned multiwall carbon nanotubes. We obtain a Gaussian energy resolution between 0.8 and 1.8 eV for fully absorbed electrons in the ( 90 – 101 ) eV energy range, which is found to be compatible with the resolution of this same device for photons in the same energy range. This work opens possibilities for high-precision energy measurements of low-energy electrons. Published by the American Physical Society 2024
- 29 October 2024
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 22 (4)
Open AccessDetection of low-energy electrons with transition-edge sensors
We present the detection of electrons with kinetic energy in the 100 eV range with transition-edge sensors (TESs). This has been achieved with a ( 100 × 100 ) - μ m 2 Ti/Au bilayer TES, with a critical temperature of about 84 mK. The electrons are produced directly in the cryostat by an innovative cold source based on field emission from vertically aligned multiwall carbon nanotubes. We obtain a Gaussian energy resolution between 0.8 and 1.8 eV for fully absorbed electrons in the ( 90 – 101 ) eV energy range, which is found to be compatible with the resolution of this same device for photons in the same energy range. This work opens possibilities for high-precision energy measurements of low-energy electrons. Published by the American Physical Society 2024