Kieran M. Farrell
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kieran M. Farrell has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Martin T. Zanni
Department of Chemistry, University of Wisconsin–Madison 4 , Madison, Wisconsin 53706
8 shared publications - Sidney Steven Dicke
Department of Chemistry, University of Wisconsin−Madison, Madison, Wisconsin 53706, United States
2 shared publications Alexander Al-Zubeidi
Center for Adopting Flaws as Features, University of Illinois at Urbana-Champaign, Urbana, IL, USA
1 shared publicationAnastasiia Misiura
Center for Adopting Flaws as Features, University of Illinois at Urbana-Champaign, Urbana, IL, USA
1 shared publicationAndrew C. Jones
1 shared publication- Ariel M. Alperstein
Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware
1 shared publication
Latest Publications
- 3 December 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 161 (21)
Mitigation of thermal artifacts in 100 kHz ultrafast 2D IR spectroscopy
Ytterbium lasers make possible shot-to-shot data collection of two-dimensional infrared (2D IR) spectra at 100 kHz and higher repetition rates. At those rates, the power absorbed by the sample is appreciable and creates a steady state temperature rise and an accumulated thermal grating artifact in the spectra that can obscure weak or low concentration IR chromophores. We report the magnitude of the temperature rise, the pulse ordering by which it is created, and ways to mitigate it. Using a calibrant molecule, we measured a steady-state temperature up to 32.5 and 45 °C for laser light at 4 µm in H2O and 6 µm in D2O, respectively, for a typical optical density used in 2D IR experiments. The temperature reached a steady state in ∼60 s. The temperature rise scales with the integrated optical density of the sample across the laser spectrum. By cooling the sample cell, we returned the steady state temperature to room temperature within the laser focus. For samples that undergo rotation, the accumulated thermal grating artifact is removed using a perpendicular ⟨XXYY⟩ polarization because the permuted time-orderings of the thermal grating artifact has the orientational response ⟨XYXY⟩, which decays to zero during the delay between consecutive laser pulses. The procedure described in this study can be used to characterize and minimize the thermal effects in experiments where repetition rate and/or pulse energy cause an appreciable temperature rise.
- 3 December 2024
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 161 (21)
Mitigation of thermal artifacts in 100 kHz ultrafast 2D IR spectroscopy
Ytterbium lasers make possible shot-to-shot data collection of two-dimensional infrared (2D IR) spectra at 100 kHz and higher repetition rates. At those rates, the power absorbed by the sample is appreciable and creates a steady state temperature rise and an accumulated thermal grating artifact in the spectra that can obscure weak or low concentration IR chromophores. We report the magnitude of the temperature rise, the pulse ordering by which it is created, and ways to mitigate it. Using a calibrant molecule, we measured a steady-state temperature up to 32.5 and 45 °C for laser light at 4 µm in H2O and 6 µm in D2O, respectively, for a typical optical density used in 2D IR experiments. The temperature reached a steady state in ∼60 s. The temperature rise scales with the integrated optical density of the sample across the laser spectrum. By cooling the sample cell, we returned the steady state temperature to room temperature within the laser focus. For samples that undergo rotation, the accumulated thermal grating artifact is removed using a perpendicular ⟨XXYY⟩ polarization because the permuted time-orderings of the thermal grating artifact has the orientational response ⟨XYXY⟩, which decays to zero during the delay between consecutive laser pulses. The procedure described in this study can be used to characterize and minimize the thermal effects in experiments where repetition rate and/or pulse energy cause an appreciable temperature rise.
- Top Cited PapersOpen Access
- 5 July 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (27) , eadp3353
The role of the plasmon in interfacial charge transfer
The lack of a detailed mechanistic understanding for plasmon-mediated charge transfer at metal-semiconductor interfaces severely limits the design of efficient photovoltaic and photocatalytic devices. A major remaining question is the relative contribution from indirect transfer of hot electrons generated by plasmon decay in the metal to the semiconductor compared to direct metal-to-semiconductor interfacial charge transfer. Here, we demonstrate an overall electron transfer efficiency of 44 ± 3% from gold nanorods to titanium oxide shells when excited on resonance. We prove that half of it originates from direct interfacial charge transfer mediated specifically by exciting the plasmon. We are able to distinguish between direct and indirect pathways through multimodal frequency-resolved approach measuring the homogeneous plasmon linewidth by single-particle scattering spectroscopy and time-resolved transient absorption spectroscopy with variable pump wavelengths. Our results signify that the direct plasmon-induced charge transfer pathway is a promising way to improve hot carrier extraction efficiency by circumventing metal intrinsic decay that results mainly in nonspecific heating.
- 5 July 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (27) , eadp3353
Top Cited PapersOpen AccessThe role of the plasmon in interfacial charge transfer
The lack of a detailed mechanistic understanding for plasmon-mediated charge transfer at metal-semiconductor interfaces severely limits the design of efficient photovoltaic and photocatalytic devices. A major remaining question is the relative contribution from indirect transfer of hot electrons generated by plasmon decay in the metal to the semiconductor compared to direct metal-to-semiconductor interfacial charge transfer. Here, we demonstrate an overall electron transfer efficiency of 44 ± 3% from gold nanorods to titanium oxide shells when excited on resonance. We prove that half of it originates from direct interfacial charge transfer mediated specifically by exciting the plasmon. We are able to distinguish between direct and indirect pathways through multimodal frequency-resolved approach measuring the homogeneous plasmon linewidth by single-particle scattering spectroscopy and time-resolved transient absorption spectroscopy with variable pump wavelengths. Our results signify that the direct plasmon-induced charge transfer pathway is a promising way to improve hot carrier extraction efficiency by circumventing metal intrinsic decay that results mainly in nonspecific heating.
- 20 December 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 14 (51) , 11750-11757
Simultaneously Measured Kinetics of Two Amyloid Polymorphs Using Cross Peak Specific 2D IR Spectroscopy
The origin of in vitro amyloid fibril polymorphs is debated, in part, because few techniques can simultaneously monitor the formation kinetics of multiple amyloid polymorphs. Using a cross-peak specific polarization scheme, ⟨0°,0°,60°,-60°⟩, we resolve 22 previously unseen cross peaks in the 2D IR spectra of amyloid fibrils formed by the human islet amyloid polypeptide (hIAPP). Those cross peaks include a subset assigned to a second fibril polymorph, which forms on a slower time scale. We simulated the data with three different kinetic models for polymorph formation. Only a model based on secondary nucleation reproduces the cross peak kinetics. These experiments are evidence that fibrils formed by secondary nucleation have a different polymorphic structure than the parent fibrils and illustrate the enhanced structural resolution of this new cross peak specific polarization scheme.
- 20 December 2023
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry Letters
- Vol. 14 (51) , 11750-11757
Simultaneously Measured Kinetics of Two Amyloid Polymorphs Using Cross Peak Specific 2D IR Spectroscopy
The origin of in vitro amyloid fibril polymorphs is debated, in part, because few techniques can simultaneously monitor the formation kinetics of multiple amyloid polymorphs. Using a cross-peak specific polarization scheme, ⟨0°,0°,60°,-60°⟩, we resolve 22 previously unseen cross peaks in the 2D IR spectra of amyloid fibrils formed by the human islet amyloid polypeptide (hIAPP). Those cross peaks include a subset assigned to a second fibril polymorph, which forms on a slower time scale. We simulated the data with three different kinetic models for polymorph formation. Only a model based on secondary nucleation reproduces the cross peak kinetics. These experiments are evidence that fibrils formed by secondary nucleation have a different polymorphic structure than the parent fibrils and illustrate the enhanced structural resolution of this new cross peak specific polarization scheme.
- 6 July 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 157 (1) , 014203
Phase stable, shot-to-shot measurement of third- and fifth-order two-quantum correlation spectra using a pulse shaper in the pump–probe geometry
We demonstrate the first phase stable measurement of a third-order 2Q spectrum using a pulse shaper in the pump–probe geometry. This measurement was achieved by permuting the time-ordering of the pump pulses, thus rearranging the signal pathways that are emitted in the probe direction. The third-order 2Q spectrum is self-heterodyned by the probe pulse. Using this method, one can interconvert between a 1Q experiment and a 2Q experiment by simply reprogramming a pulse shaper or delay stage. We also measure a fifth-order absorptive 2Q spectrum in the pump–probe geometry, which contains similar information as a third-order experiment but does not suffer from dispersive line shapes. To do so, we introduce methods to minimize saturation-induced artifacts of the pulse shaper, improving fifth-order signals. These techniques add new capabilities for 2D spectrometers that use pulse shapers in the pump–probe beam geometry.
- 6 July 2022
- Published by AIP Publishing in The Journal of Chemical Physics
- Vol. 157 (1) , 014203
Phase stable, shot-to-shot measurement of third- and fifth-order two-quantum correlation spectra using a pulse shaper in the pump–probe geometry
We demonstrate the first phase stable measurement of a third-order 2Q spectrum using a pulse shaper in the pump–probe geometry. This measurement was achieved by permuting the time-ordering of the pump pulses, thus rearranging the signal pathways that are emitted in the probe direction. The third-order 2Q spectrum is self-heterodyned by the probe pulse. Using this method, one can interconvert between a 1Q experiment and a 2Q experiment by simply reprogramming a pulse shaper or delay stage. We also measure a fifth-order absorptive 2Q spectrum in the pump–probe geometry, which contains similar information as a third-order experiment but does not suffer from dispersive line shapes. To do so, we introduce methods to minimize saturation-induced artifacts of the pulse shaper, improving fifth-order signals. These techniques add new capabilities for 2D spectrometers that use pulse shapers in the pump–probe beam geometry.
- Open Access
- 3 February 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (6)
A polarization scheme that resolves cross-peaks with transient absorption and eliminates diagonal peaks in 2D spectroscopy
Two-dimensional (2D) optical spectroscopy contains cross-peaks that are helpful features for determining molecular structure and monitoring energy transfer, but they can be difficult to resolve from the much more intense diagonal peaks. Transient absorption (TA) spectra contain transitions similar to cross-peaks in 2D spectroscopy, but in most cases they are obscured by the bleach and stimulated emission peaks. We report a polarization scheme, , that can be easily implemented in the pump-probe beam geometry, used most frequently in 2D and TA spectroscopy. This scheme removes the diagonal peaks in 2D spectroscopies and the intense bleach/stimulated emission peaks in TA spectroscopies, thereby resolving the cross-peak features. At zero pump-probe delay, θ 2 = 60° destructively interferes two Feynman paths, eliminating all signals generated by field interactions with four parallel transition dipoles, and the intense diagonal and bleach/stimulated emission peaks. At later delay times, θ 2 (t 2 ) is adjusted to compensate for anisotropy caused by rotational diffusion. When implemented with TA spectroscopy or microscopy, the pump-probe spectrum is dominated by the cross-peak features. The local oscillator is also attenuated, which enhances the signal two times. This overlooked polarization scheme reduces spectral congestion by eliminating diagonal peaks in 2D spectra and enables TA spectroscopy to measure similar information given by cross-peaks in 2D spectroscopy.
- 3 February 2022
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 119 (6)
Open AccessA polarization scheme that resolves cross-peaks with transient absorption and eliminates diagonal peaks in 2D spectroscopy
Two-dimensional (2D) optical spectroscopy contains cross-peaks that are helpful features for determining molecular structure and monitoring energy transfer, but they can be difficult to resolve from the much more intense diagonal peaks. Transient absorption (TA) spectra contain transitions similar to cross-peaks in 2D spectroscopy, but in most cases they are obscured by the bleach and stimulated emission peaks. We report a polarization scheme, , that can be easily implemented in the pump-probe beam geometry, used most frequently in 2D and TA spectroscopy. This scheme removes the diagonal peaks in 2D spectroscopies and the intense bleach/stimulated emission peaks in TA spectroscopies, thereby resolving the cross-peak features. At zero pump-probe delay, θ 2 = 60° destructively interferes two Feynman paths, eliminating all signals generated by field interactions with four parallel transition dipoles, and the intense diagonal and bleach/stimulated emission peaks. At later delay times, θ 2 (t 2 ) is adjusted to compensate for anisotropy caused by rotational diffusion. When implemented with TA spectroscopy or microscopy, the pump-probe spectrum is dominated by the cross-peak features. The local oscillator is also attenuated, which enhances the signal two times. This overlooked polarization scheme reduces spectral congestion by eliminating diagonal peaks in 2D spectra and enables TA spectroscopy to measure similar information given by cross-peaks in 2D spectroscopy.
- Open Access
- 14 September 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (9) , e0257098
Analysis of amyloid-like secondary structure in the Cryab-R120G knock-in mouse model of hereditary cataracts by two-dimensional infrared spectroscopy
αB-crystallin is a small heat shock protein that forms a heterooligomeric complex with αA-crystallin in the ocular lens. It is also widely distributed in tissues throughout the body and has been linked with neurodegenerative diseases such as Alzheimer’s, where it is associated with amyloid fibrils. Crystallins can form amorphous aggregates in cataracts as well as more structured amyloid-like fibrils. The arginine 120 to glycine (R120G) mutation in αB-crystallin (Cryab-R120G) results in high molecular weight crystallin protein aggregates and loss of the chaperone activity of the proteinin vitro, and it is associated with human hereditary cataracts and myopathy. Characterizing the amorphous (unstructured) versus the highly ordered (amyloid fibril) nature of crystallin aggregates is important in understanding their role in disease and important to developing pharmacological treatments for cataracts. We investigated protein secondary structure in wild-type (WT) andCryab-R120G knock-in mutant mouse lenses using two-dimensional infrared (2DIR) spectroscopy, which has been used to detect amyloid-like fibrils in human lenses and measure UV radiation-induced changes in porcine lenses. Our goal was to compare the aggregated proteins in this mouse lens model to human lenses and evaluate the protein structural relevance of theCryab-R120G knock-in mouse model to general age-related cataract disease. In the 2DIR spectra, amide I diagonal peak frequencies were red-shifted to smaller wavenumbers in mutant mouse lenses as compared to WT mouse lenses, consistent with an increase in ordered secondary structure. The cross peak frequency and intensity indicated the presence of amyloid in the mutant mouse lenses. While the diagonal and cross peak changes in location and intensity from the 2DIR spectra indicated significant structural differences between the wild type and mutant mouse lenses, these differences were smaller than those found in human lenses; thus, theCryab-R120G knock-in mouse lenses contain less amyloid-like secondary structure than human lenses. The results of the 2DIR spectroscopy study confirm the presence of amyloid-like secondary structure inCryab-R120G knock-in mice with cataracts and support the use of this model to study age-related cataract.
- 14 September 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (9) , e0257098
Open AccessAnalysis of amyloid-like secondary structure in the Cryab-R120G knock-in mouse model of hereditary cataracts by two-dimensional infrared spectroscopy
αB-crystallin is a small heat shock protein that forms a heterooligomeric complex with αA-crystallin in the ocular lens. It is also widely distributed in tissues throughout the body and has been linked with neurodegenerative diseases such as Alzheimer’s, where it is associated with amyloid fibrils. Crystallins can form amorphous aggregates in cataracts as well as more structured amyloid-like fibrils. The arginine 120 to glycine (R120G) mutation in αB-crystallin (Cryab-R120G) results in high molecular weight crystallin protein aggregates and loss of the chaperone activity of the proteinin vitro, and it is associated with human hereditary cataracts and myopathy. Characterizing the amorphous (unstructured) versus the highly ordered (amyloid fibril) nature of crystallin aggregates is important in understanding their role in disease and important to developing pharmacological treatments for cataracts. We investigated protein secondary structure in wild-type (WT) andCryab-R120G knock-in mutant mouse lenses using two-dimensional infrared (2DIR) spectroscopy, which has been used to detect amyloid-like fibrils in human lenses and measure UV radiation-induced changes in porcine lenses. Our goal was to compare the aggregated proteins in this mouse lens model to human lenses and evaluate the protein structural relevance of theCryab-R120G knock-in mouse model to general age-related cataract disease. In the 2DIR spectra, amide I diagonal peak frequencies were red-shifted to smaller wavenumbers in mutant mouse lenses as compared to WT mouse lenses, consistent with an increase in ordered secondary structure. The cross peak frequency and intensity indicated the presence of amyloid in the mutant mouse lenses. While the diagonal and cross peak changes in location and intensity from the 2DIR spectra indicated significant structural differences between the wild type and mutant mouse lenses, these differences were smaller than those found in human lenses; thus, theCryab-R120G knock-in mouse lenses contain less amyloid-like secondary structure than human lenses. The results of the 2DIR spectroscopy study confirm the presence of amyloid-like secondary structure inCryab-R120G knock-in mice with cataracts and support the use of this model to study age-related cataract.
- 22 October 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (22) , 33584-33602
Shot-to-shot 2D IR spectroscopy at 100 kHz using a Yb laser and custom-designed electronics
The majority of 2D IR spectrometers operate at 1-10 kHz using Ti:Sapphire laser technology. We report a 2D IR spectrometer designed around Yb:KGW laser technology that operates shot-to-shot at 100 kHz. It includes a home-built OPA, a mid-IR pulse shaper, and custom-designed electronics with optional on-chip processing. We report a direct comparison between Yb:KGW and Ti:Sapphire based 2D IR spectrometers. Even though the mid-IR pulse energy is much lower for the Yb:KGW driven system, there is an 8x improvement in signal-to-noise over the 1 kHz Ti:Sapphire driven spectrometer to which it is compared. Experimental data is shown for sub-millimolar concentrations of amides. Advantages and disadvantages of the design are discussed, including thermal background that arises at high repetition rates. This fundamental spectrometer design takes advantage of newly available Yb laser technology in a new way, providing a straightforward means of enhancing sensitivity.
- 22 October 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (22) , 33584-33602
Shot-to-shot 2D IR spectroscopy at 100 kHz using a Yb laser and custom-designed electronics
The majority of 2D IR spectrometers operate at 1-10 kHz using Ti:Sapphire laser technology. We report a 2D IR spectrometer designed around Yb:KGW laser technology that operates shot-to-shot at 100 kHz. It includes a home-built OPA, a mid-IR pulse shaper, and custom-designed electronics with optional on-chip processing. We report a direct comparison between Yb:KGW and Ti:Sapphire based 2D IR spectrometers. Even though the mid-IR pulse energy is much lower for the Yb:KGW driven system, there is an 8x improvement in signal-to-noise over the 1 kHz Ti:Sapphire driven spectrometer to which it is compared. Experimental data is shown for sub-millimolar concentrations of amides. Advantages and disadvantages of the design are discussed, including thermal background that arises at high repetition rates. This fundamental spectrometer design takes advantage of newly available Yb laser technology in a new way, providing a straightforward means of enhancing sensitivity.
- Open Access
- 8 July 2019
- Published by American Chemical Society (ACS) in ACS Central Science
- Vol. 5 (7) , 1114-1116
Observing Aqueous Proton Transfer Dynamics
- 8 July 2019
- Published by American Chemical Society (ACS) in ACS Central Science
- Vol. 5 (7) , 1114-1116
Open AccessObserving Aqueous Proton Transfer Dynamics