Ian Robert Hill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ian Robert Hill has a total of 178 co-authors. Here are the top co-authors by number of shared publications:
- Elizabeth Anne Curtis
National Physical Laboratory
5 shared publications - Marco Schioppo
National Physical Laboratory (NPL)
5 shared publications - Cecilia Clivati
Istituto Nazionale di Ricerca Metrologica (INRiM)
4 shared publications - Davide Calonico
Istituto Nazionale di Ricerca Metrologica (INRiM)
4 shared publications - Helen S. Margolis
National Physical Laboratory
4 shared publications Patrick Gill
National Physical Laboratory
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (3) , 033250
International optical clock comparison using the European optical fiber network
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the 10 − 18 level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from 7.7 × 10 − 18 to 6.1 × 10 − 17 . Among the results, the Yb + 171 ( E 3 ) clocks at NPL and PTB demonstrated agreement within an uncertainty of 7.7 × 10 − 18 , marking the first international verification of two independently developed optical clocks below one part in 10 17 . The operation of the Hg 199 clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with Yb + 171 ( E 3 ) , Yb 171 , and Sr 87 optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.
- 1 September 2026
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 8 (3) , 033250
Open AccessInternational optical clock comparison using the European optical fiber network
Optical clocks have achieved remarkable estimated fractional frequency uncertainties reaching the 10 − 18 level and below, enabling applications in fundamental physics, general relativity, and geodesy. However, the challenge of verifying the international consistency of optical clocks remains critical as efforts intensify toward redefining the SI second based on an optical transition or transitions. We report on a two-month international clock comparison campaign involving seven optical clocks in four national metrology institutes (INRIM, LNE-OP, NPL, and PTB) connected via the optical fiber network established in Europe. The campaign resulted in optical frequency ratios with uncertainties ranging from 7.7 × 10 − 18 to 6.1 × 10 − 17 . Among the results, the Yb + 171 ( E 3 ) clocks at NPL and PTB demonstrated agreement within an uncertainty of 7.7 × 10 − 18 , marking the first international verification of two independently developed optical clocks below one part in 10 17 . The operation of the Hg 199 clock at LNE-OP (formerly LNE-SYRTE) resulted in frequency ratios with improved uncertainties with Yb + 171 ( E 3 ) , Yb 171 , and Sr 87 optical clocks. These results provide input for the redefinition of the second and underscore how fiber-linked clock networks can advance metrology and scientific applications.
- Open Access
- 12 June 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 843
Coordinated international comparisons between optical clocks connected via fiber and satellite links
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.
- 12 June 2025
- Published by Optica Publishing Group in Optica
- Vol. 12 (6) , 843
Open AccessCoordinated international comparisons between optical clocks connected via fiber and satellite links
Optical clocks provide ultraprecise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time to our knowledge, while others had significantly lower uncertainties than previously achieved, supporting the advance toward a redefinition of the second and the use of optical standards for international time scales.
- Open Access
- 31 January 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (4) , 5380-5396
Towards space-deployable laser stabilization systems based on vibration-insensitive cubic cavities with crystalline coatings
We present the development of a transportable laser frequency stabilization system with application to both optical clocks and a next-generation gravity mission (NGGM) in space. This effort leverages a 5-cm long cubic cavity with crystalline coatings operating at room temperature and with a center wavelength of 1064 nm. The cavity is integrated in a custom vacuum chamber with dedicated low-noise locking electronics. Our vacuum-mounted cavity and control system are well suited for space applications, exhibiting state-of-the-art noise performance while being resilient to radiation exposure, vibration, shock, and temperature variations. Furthermore, we demonstrate a robust means of automatically (re)locking the laser to the cavity when resonance is lost. We show that the mounted cavity is capable of reaching technology readiness level (TRL) 6, paving the way for high-performance ultrastable laser systems and eventually optical atomic clocks amenable to future satellite platforms.
- 31 January 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (4) , 5380-5396
Open AccessTowards space-deployable laser stabilization systems based on vibration-insensitive cubic cavities with crystalline coatings
We present the development of a transportable laser frequency stabilization system with application to both optical clocks and a next-generation gravity mission (NGGM) in space. This effort leverages a 5-cm long cubic cavity with crystalline coatings operating at room temperature and with a center wavelength of 1064 nm. The cavity is integrated in a custom vacuum chamber with dedicated low-noise locking electronics. Our vacuum-mounted cavity and control system are well suited for space applications, exhibiting state-of-the-art noise performance while being resilient to radiation exposure, vibration, shock, and temperature variations. Furthermore, we demonstrate a robust means of automatically (re)locking the laser to the cavity when resonance is lost. We show that the mounted cavity is capable of reaching technology readiness level (TRL) 6, paving the way for high-performance ultrastable laser systems and eventually optical atomic clocks amenable to future satellite platforms.
- Top Cited PapersOpen Access
- 1 September 2023
- Published by IOP Publishing in New Journal of Physics
- Vol. 25 (9) , 093012
Analysis of atomic-clock data to constrain variations of fundamental constants
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on87Sr,171Yb+and133Cs, we set bounds on parameters controlling the variation of the fine-structure constant,α, and the electron-to-proton mass ratio,µ. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
- 1 September 2023
- Published by IOP Publishing in New Journal of Physics
- Vol. 25 (9) , 093012
Top Cited PapersOpen AccessAnalysis of atomic-clock data to constrain variations of fundamental constants
We present a new framework to study the time variation of fundamental constants in a model-independent way. Model independence implies more free parameters than assumed in previous studies. Using data from atomic clocks based on87Sr,171Yb+and133Cs, we set bounds on parameters controlling the variation of the fine-structure constant,α, and the electron-to-proton mass ratio,µ. We consider variations on timescales ranging from a minute to almost a day. In addition, we use our results to derive some of the tightest limits to date on the parameter space of models of ultralight dark matter and axion-like particles.
- 1 January 2023
- Published by Optica Publishing Group
- p. M2C.1
Transforming Subsea Optical Cables into a Giant Network of Environmental Sensors
We show that seafloor-cables, when combined with ultra-stable interferometry, can act as arrays of environmental sensors for earthquakes, ocean currents and other ocean signals, with potentially game-changing applications in Earth monitoring.
- 1 January 2023
- Published by Optica Publishing Group
- p. M2C.1
Transforming Subsea Optical Cables into a Giant Network of Environmental Sensors
We show that seafloor-cables, when combined with ultra-stable interferometry, can act as arrays of environmental sensors for earthquakes, ocean currents and other ocean signals, with potentially game-changing applications in Earth monitoring.
- Top Cited Papers
- 20 May 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 376 (6595) , 874-879
Optical interferometry–based array of seafloor environmental sensors using a transoceanic submarine cable
Optical fiber–based sensing technology can drastically improve Earth observations by enabling the use of existing submarine communication cables as seafloor sensors. Previous interferometric and polarization-based techniques demonstrated environmental sensing over cable lengths up to 10,500 kilometers. However, measurements were limited to the integrated changes over the entire length of the cable. We demonstrate the detection of earthquakes and ocean signals on individual spans between repeaters of a 5860-kilometer-long transatlantic cable rather than the whole cable. By applying this technique to the existing undersea communication cables, which have a repeater-to-repeater span length of 45 to 90 kilometers, the largely unmonitored ocean floor could be instrumented with thousands of permanent real-time environmental sensors without changes to the underwater infrastructure.
- 20 May 2022
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 376 (6595) , 874-879
Top Cited PapersOptical interferometry–based array of seafloor environmental sensors using a transoceanic submarine cable
Optical fiber–based sensing technology can drastically improve Earth observations by enabling the use of existing submarine communication cables as seafloor sensors. Previous interferometric and polarization-based techniques demonstrated environmental sensing over cable lengths up to 10,500 kilometers. However, measurements were limited to the integrated changes over the entire length of the cable. We demonstrate the detection of earthquakes and ocean signals on individual spans between repeaters of a 5860-kilometer-long transatlantic cable rather than the whole cable. By applying this technique to the existing undersea communication cables, which have a repeater-to-repeater span length of 45 to 90 kilometers, the largely unmonitored ocean floor could be instrumented with thousands of permanent real-time environmental sensors without changes to the underwater infrastructure.
- Open Access
- 15 December 2021
- Published by Frontiers Media SA in Frontiers: A Journal of Women Studies
- Vol. 1
Saliva for COVID-19 Testing: Simple but Useless or an Undervalued Resource?
During the COVID-19 pandemic, countries with robust population-based asymptomatic testing were generally successful in controlling virus spread, hence reducing hospitalizations and deaths. This effectiveness inspired widespread asymptomatic surveillance for COVID-19/SARS-CoV-2 globally. Polarized vaccination programs, coupled with the relatively short-lived immunity vaccines provide, mean that reciprocal cross-border exchanges of each new variant are likely, as evidenced by Delta and Gamma, and asymptomatic testing will be required for the foreseeable future. Reliance on nasopharyngeal swabs contributes to “testing fatigue” arising due to difficulties in standardizing administration, unpleasantness, and inappropriateness of use in younger people or individuals with special needs. There has also been erosion in confidence of testing due to variable and/or poor accuracy of lateral flow devices to detect COVID-19. Here, we question why saliva-based PCR assays are not being used more widely, given that standardization is easy and this non-invasive test is suitable for everyone, providing high sensitivity and accuracy. We reflect on our experience with the University of Nottingham COVID-19 Asymptomatic Testing, where (as of October 2021) 96,317 samples have been processed by RT-qPCR from 23,740 repeat saliva donors, yielding 465 positive cases. We challenge myths that saliva is difficult to process, concluding that it is an undervalued resource for both asymptomatic and symptomatic detection of SARS-CoV-2 genomes to an accuracy of >99% and a sensitivity of 1–10 viral copies/μl. In July 2021, our data enabled Nottingham to become the first UK University to gain accreditation and the first UK institute to gain this accolade for saliva.
- 15 December 2021
- Published by Frontiers Media SA in Frontiers: A Journal of Women Studies
- Vol. 1
Open AccessSaliva for COVID-19 Testing: Simple but Useless or an Undervalued Resource?
During the COVID-19 pandemic, countries with robust population-based asymptomatic testing were generally successful in controlling virus spread, hence reducing hospitalizations and deaths. This effectiveness inspired widespread asymptomatic surveillance for COVID-19/SARS-CoV-2 globally. Polarized vaccination programs, coupled with the relatively short-lived immunity vaccines provide, mean that reciprocal cross-border exchanges of each new variant are likely, as evidenced by Delta and Gamma, and asymptomatic testing will be required for the foreseeable future. Reliance on nasopharyngeal swabs contributes to “testing fatigue” arising due to difficulties in standardizing administration, unpleasantness, and inappropriateness of use in younger people or individuals with special needs. There has also been erosion in confidence of testing due to variable and/or poor accuracy of lateral flow devices to detect COVID-19. Here, we question why saliva-based PCR assays are not being used more widely, given that standardization is easy and this non-invasive test is suitable for everyone, providing high sensitivity and accuracy. We reflect on our experience with the University of Nottingham COVID-19 Asymptomatic Testing, where (as of October 2021) 96,317 samples have been processed by RT-qPCR from 23,740 repeat saliva donors, yielding 465 positive cases. We challenge myths that saliva is difficult to process, concluding that it is an undervalued resource for both asymptomatic and symptomatic detection of SARS-CoV-2 genomes to an accuracy of >99% and a sensitivity of 1–10 viral copies/μl. In July 2021, our data enabled Nottingham to become the first UK University to gain accreditation and the first UK institute to gain this accolade for saliva.
- 22 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (22) , 36758-36768
Dual-axis cubic cavity for drift-compensated multi-wavelength laser stabilisation
We describe a ‘clock control unit’ based on a dual-axis cubic cavity (DACC) for the frequency stabilisation of lasers involved in a strontium optical lattice clock. The DACC, which ultimately targets deployment in space applications, provides a short-term stable reference for all auxiliary lasers—i.e. cooling, clear-out, and optical lattice—in a single multi-band cavity. Long-term cavity drift is compensated by a feed-forward scheme exploiting a fixed physical relation to an orthogonal second cavity axis; either by reference to an ultrastable 698 nm clock laser, or by exploiting the differential drift between orthogonal axes extracted by a single laser in common view. Via a change of mirror set in the cavity axis accessed by the clock laser, the system could also provide stabilisation for sub-Hz linewidths at the 698 nm clock wavelength, fulfilling all stabilisation requirements of the clock.
- 22 October 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (22) , 36758-36768
Dual-axis cubic cavity for drift-compensated multi-wavelength laser stabilisation
We describe a ‘clock control unit’ based on a dual-axis cubic cavity (DACC) for the frequency stabilisation of lasers involved in a strontium optical lattice clock. The DACC, which ultimately targets deployment in space applications, provides a short-term stable reference for all auxiliary lasers—i.e. cooling, clear-out, and optical lattice—in a single multi-band cavity. Long-term cavity drift is compensated by a feed-forward scheme exploiting a fixed physical relation to an orthogonal second cavity axis; either by reference to an ultrastable 698 nm clock laser, or by exploiting the differential drift between orthogonal axes extracted by a single laser in common view. Via a change of mirror set in the cavity axis accessed by the clock laser, the system could also provide stabilisation for sub-Hz linewidths at the 698 nm clock wavelength, fulfilling all stabilisation requirements of the clock.
- Open Access
- 15 December 2020
- Published by American Physical Society (APS) in Physical Review X
- Vol. 10 (4) , 041052
Improving the Factor of an Optical Atomic Clock Using Quantum Nondemolition MeasurementQuantum nondemolition (QND) measurement is a remarkable tool for the manipulation of quantum systems. It allows specific information to be extracted while still preserving fragile quantum observables of the system. Here we apply cavity-based QND measurement to an optical lattice clock—a type of atomic clock with unrivaled frequency precision—preserving the quantum coherence of the atoms after readout with 80% fidelity. We apply this technique to stabilize the phase of an ultrastable laser to a coherent atomic state via a series of repeated QND measurements. We exploit the improved phase coherence of the ultrastable laser to interrogate a separate optical lattice clock, using a Ramsey spectroscopy time extended from 300 ms to 2 s. With this technique we maintain 95% contrast and observe a sevenfold increase in the clock’s factor to .- 15 December 2020
- Published by American Physical Society (APS) in Physical Review X
- Vol. 10 (4) , 041052
Open AccessImproving the Factor of an Optical Atomic Clock Using Quantum Nondemolition MeasurementQuantum nondemolition (QND) measurement is a remarkable tool for the manipulation of quantum systems. It allows specific information to be extracted while still preserving fragile quantum observables of the system. Here we apply cavity-based QND measurement to an optical lattice clock—a type of atomic clock with unrivaled frequency precision—preserving the quantum coherence of the atoms after readout with 80% fidelity. We apply this technique to stabilize the phase of an ultrastable laser to a coherent atomic state via a series of repeated QND measurements. We exploit the improved phase coherence of the ultrastable laser to interrogate a separate optical lattice clock, using a Ramsey spectroscopy time extended from 300 ms to 2 s. With this technique we maintain 95% contrast and observe a sevenfold increase in the clock’s factor to .