Naoto Tamai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Naoto Tamai has a total of 169 co-authors. Here are the top co-authors by number of shared publications:
Kazuki Sumiyama
Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
16 shared publications- Kazuki Sumiyama
Department of Endoscopy The Jikei University School of Medicine Tokyo Japan
10 shared publications Daisuke Ide
Endoscopy, The Jikei University School of Medicine, Tokyo, Japan
8 shared publicationsHiroko Inomata
Department of Endoscopy, The Jikei University School of Medicine , Tokyo , Japan
8 shared publicationsHisao Tajiri
Department of Innovative Interventional Endoscopy Research, The Jikei University School of Medicine, Tokyo, Japan
8 shared publications- Hisao Tajiri
The Jikei University School of Medicine
7 shared publications
Latest Publications
- 13 November 2026
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (11)
Navigating Sessile Serrated Lesions in an Aging Population
- 13 November 2026
- Published by Wiley in Digestive Endoscopy
- Vol. 38 (11)
Navigating Sessile Serrated Lesions in an Aging Population
- Open Access
- 5 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1739
Assessment of Red Dichromatic Imaging with Indigo Carmine for Identifying Deep Submucosal Invasion in Colorectal Tumors: A Pilot Study
Background/Objectives: Accurate pT1b diagnosis in colorectal cancer is vital owing to the risk of lymph node metastasis. While Japan NBI (narrow band imaging) Expert Team (JNET) classification is widely applied, accurate diagnosis of type 2B lesions remains challenging, often requiring pit pattern analysis via magnifying chromoendoscopy with crystal violet staining (MCE). However, the clinical application of MCE is limited by potential carcinogenicity and prolonged procedure time. In this study, we aimed to evaluate the diagnostic performance of red dichromatic imaging with indigo carmine (RDI-indigo) in assessing the invasion depth of colorectal tumors. Methods: Ninety images were obtained from 30 colorectal tumor cases using RDI-indigo, NBI, and MCE. Six endoscopists classified images using JNET classification for NBI, and pit pattern classification for RDI-indigo and MCE. JNET type 3 and pit pattern classification V irregular, high grade/V non-structure were correlated with pathological depth ≥pT1b. The primary outcome was the diagnostic accuracy for ≥pT1b. Results: Diagnostic accuracies for ≥pT1b were 85.0% (95% CI: 79.8–90.2%) for RDI-indigo, 79.4% (95% CI: 73.5–85.3%) for NBI, and 82.8% (95% CI: 77.3–88.3%) for MCE. Intraobserver agreement between RDI-indigo and MCE showed fair agreement (Cohen’s kappa = 0.39), while interobserver agreement was moderate for MCE (Fleiss’ kappa = 0.56) and fair for RDI-indigo (Fleiss’ kappa = 0.36). Gwet’s AC1 indicated substantial agreement across all assessments (0.69–0.80). Conclusions: As the first report evaluating RDI-indigo for colorectal tumors, this study suggests that RDI-indigo could serve as a complementary MCE-like tool for the diagnosis of ≥pT1b lesions.
- 5 June 2026
- Published by MDPI AG in Diagnostics
- Vol. 16 (11) , 1739
Open AccessAssessment of Red Dichromatic Imaging with Indigo Carmine for Identifying Deep Submucosal Invasion in Colorectal Tumors: A Pilot Study
Background/Objectives: Accurate pT1b diagnosis in colorectal cancer is vital owing to the risk of lymph node metastasis. While Japan NBI (narrow band imaging) Expert Team (JNET) classification is widely applied, accurate diagnosis of type 2B lesions remains challenging, often requiring pit pattern analysis via magnifying chromoendoscopy with crystal violet staining (MCE). However, the clinical application of MCE is limited by potential carcinogenicity and prolonged procedure time. In this study, we aimed to evaluate the diagnostic performance of red dichromatic imaging with indigo carmine (RDI-indigo) in assessing the invasion depth of colorectal tumors. Methods: Ninety images were obtained from 30 colorectal tumor cases using RDI-indigo, NBI, and MCE. Six endoscopists classified images using JNET classification for NBI, and pit pattern classification for RDI-indigo and MCE. JNET type 3 and pit pattern classification V irregular, high grade/V non-structure were correlated with pathological depth ≥pT1b. The primary outcome was the diagnostic accuracy for ≥pT1b. Results: Diagnostic accuracies for ≥pT1b were 85.0% (95% CI: 79.8–90.2%) for RDI-indigo, 79.4% (95% CI: 73.5–85.3%) for NBI, and 82.8% (95% CI: 77.3–88.3%) for MCE. Intraobserver agreement between RDI-indigo and MCE showed fair agreement (Cohen’s kappa = 0.39), while interobserver agreement was moderate for MCE (Fleiss’ kappa = 0.56) and fair for RDI-indigo (Fleiss’ kappa = 0.36). Gwet’s AC1 indicated substantial agreement across all assessments (0.69–0.80). Conclusions: As the first report evaluating RDI-indigo for colorectal tumors, this study suggests that RDI-indigo could serve as a complementary MCE-like tool for the diagnosis of ≥pT1b lesions.
- 8 April 2026
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (6) , 1863-1873
Optimal Timing of Resuming Anticoagulant After Colorectal Endoscopic Submucosal Dissection
Background and Aim: Delayed bleeding after colorectal ESD is a significant adverse event, particularly in patients receiving anticoagulants. However, the optimal timing for resuming anticoagulant therapy remains unclear. This study aimed to determine the optimal timing for resuming anticoagulants after colorectal ESD. Methods: We retrospectively analyzed data from 1309 colorectal ESD cases including 957 on direct oral anticoagulants (DOACs) and 365 on warfarin from the ABCD‐J study, which included 34 450 colorectal ESD cases across 47 Japanese institutions. Patients were categorized into two groups based on the timing of anticoagulant resumption: early (resumption within 1 day post‐ESD) and late (resumption two or more days post‐ESD). After propensity score matching, delayed bleeding, delayed perforation, and thromboembolic events were compared between groups. Results: Overall, 334 matched cases were analyzed in the early and late groups. There was no significant difference in the overall delayed bleeding rate between the two groups (9.6% vs. 6.6%, p = 0.201). In the entire cohort, before resumption, the bleeding rate was significantly lower in the early group (1.18% vs. 3.23%, p = 0.013). Conversely, after resumption, it was significantly higher in the early group (9.42% vs. 6.02%, p = 0.041). Additionally, there was no significant difference in thromboembolic event rates between the groups (0% vs. 0%, p = 1.000). Subgroup analyses showed no significant difference in delayed bleeding rates within the matched groups for DOAC (210 cases; 9.0% vs. 6.2%, p = 0.358) or warfarin (105 cases; 11.4% vs. 6.7%, p = 0.336). Conclusions: The early resumption of anticoagulants within 1 day post‐ESD did not significantly increase delayed bleeding.
- 8 April 2026
- Published by Wiley in Journal of Gastroenterology and Hepatology
- Vol. 41 (6) , 1863-1873
Optimal Timing of Resuming Anticoagulant After Colorectal Endoscopic Submucosal Dissection
Background and Aim: Delayed bleeding after colorectal ESD is a significant adverse event, particularly in patients receiving anticoagulants. However, the optimal timing for resuming anticoagulant therapy remains unclear. This study aimed to determine the optimal timing for resuming anticoagulants after colorectal ESD. Methods: We retrospectively analyzed data from 1309 colorectal ESD cases including 957 on direct oral anticoagulants (DOACs) and 365 on warfarin from the ABCD‐J study, which included 34 450 colorectal ESD cases across 47 Japanese institutions. Patients were categorized into two groups based on the timing of anticoagulant resumption: early (resumption within 1 day post‐ESD) and late (resumption two or more days post‐ESD). After propensity score matching, delayed bleeding, delayed perforation, and thromboembolic events were compared between groups. Results: Overall, 334 matched cases were analyzed in the early and late groups. There was no significant difference in the overall delayed bleeding rate between the two groups (9.6% vs. 6.6%, p = 0.201). In the entire cohort, before resumption, the bleeding rate was significantly lower in the early group (1.18% vs. 3.23%, p = 0.013). Conversely, after resumption, it was significantly higher in the early group (9.42% vs. 6.02%, p = 0.041). Additionally, there was no significant difference in thromboembolic event rates between the groups (0% vs. 0%, p = 1.000). Subgroup analyses showed no significant difference in delayed bleeding rates within the matched groups for DOAC (210 cases; 9.0% vs. 6.2%, p = 0.358) or warfarin (105 cases; 11.4% vs. 6.7%, p = 0.336). Conclusions: The early resumption of anticoagulants within 1 day post‐ESD did not significantly increase delayed bleeding.
- Open Access
Comparison of Detection Yields Between Texture and Color Enhancement Imaging Mode 1 and Mode 2 for Colorectal Lesions: A Post‐hoc Analysis of a Multicenter Observational Study
Objectives: Colonoscopy is a reliable technique for the detection, diagnosis, and treatment of adenomas and early cancer. Image‐enhanced endoscopy (IEE) is important for detecting colorectal lesions. Texture and color‐enhancement imaging (TXI) has recently emerged as a novel modality for IEE. Thus, TXI operates in two modes: mode 1 (TXI1) enhances the structure, color, and brightness, whereas mode 2 (TXI2) does not. We have previously reported the detection of colorectal adenomas using TXI. We aimed to determine the detection yields of TXI1 and TXI2 using the data from our previous study. Methods: We retrospectively analyzed the colonoscopy data from three institutions between August 2020 and January 2021. The patients were classified into two groups: TXI1 and TXI2. The mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and flat adenoma detection rate (FDR) were compared between groups. Results: The evaluations (95% confidence intervals) for the TXI1 versus TXI2 groups were as follows: MAP, 1.5 (1.3–1.7) versus 1.5 (1.3–1.7); ADR, 56.8% (47.3–65.9) versus 59.7% (50.3–68.6); and FDR, 68.6% (59.5–76.9) versus 63.9% (54.6–72.5), with no statistically significant differences between the groups. Conclusion: The detection rates of colorectal lesions were comparable between the TXI1 and TXI2 groups.
Open AccessComparison of Detection Yields Between Texture and Color Enhancement Imaging Mode 1 and Mode 2 for Colorectal Lesions: A Post‐hoc Analysis of a Multicenter Observational Study
Objectives: Colonoscopy is a reliable technique for the detection, diagnosis, and treatment of adenomas and early cancer. Image‐enhanced endoscopy (IEE) is important for detecting colorectal lesions. Texture and color‐enhancement imaging (TXI) has recently emerged as a novel modality for IEE. Thus, TXI operates in two modes: mode 1 (TXI1) enhances the structure, color, and brightness, whereas mode 2 (TXI2) does not. We have previously reported the detection of colorectal adenomas using TXI. We aimed to determine the detection yields of TXI1 and TXI2 using the data from our previous study. Methods: We retrospectively analyzed the colonoscopy data from three institutions between August 2020 and January 2021. The patients were classified into two groups: TXI1 and TXI2. The mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and flat adenoma detection rate (FDR) were compared between groups. Results: The evaluations (95% confidence intervals) for the TXI1 versus TXI2 groups were as follows: MAP, 1.5 (1.3–1.7) versus 1.5 (1.3–1.7); ADR, 56.8% (47.3–65.9) versus 59.7% (50.3–68.6); and FDR, 68.6% (59.5–76.9) versus 63.9% (54.6–72.5), with no statistically significant differences between the groups. Conclusion: The detection rates of colorectal lesions were comparable between the TXI1 and TXI2 groups.
- Open Access
The competency of the novel through‐the‐scope suture device for gastric mucosal defects: In vivo study in a porcine model (with video)
Objectives: Endoscopic closures of mucosal defects following endoscopic resection can be challenging and time‐consuming. The novel through‐the‐scope suture device has demonstrated acceptable closure times, but its learning curve is still unknown. This study aims to evaluate the number of cases required to achieve competency in this device.Methods: Two endoscopists participated; a novice with less than 400 experiences in upper gastrointestinal endoscopy and an expert with over 500 experiences in endoscopic submucosal dissection. Neither endoscopist had previous exposure to the device. In four porcine models, 24 gastric mucosal defects, each 2–4 cm in diameter, were created by endoscopic mucosal resection with ligation. Each endoscopist performed endoscopic closure for 12 mucosal defects with a single through‐the‐scope suture device per lesion. The primary endpoint was the number of cases needed to reach competency, defined as achieving a procedure time below the average closure time reported in the literature. Secondary endpoints included procedure time, complete closure success rates, and incidence of adverse events.Results: The mean defect size was 2.9 (±0.2) cm. Competency was achieved after six cases in the expert and seven cases in the novice. The median closure time was 9.0 (interquartile range [IQR]: 6.0–11.0) min for the expert and 8.0 (IQR: 6.2–9.7) min for the novice (p = 0.862). Complete closure success rates were 75.0% (n = 9) for the expert and 83.3% (n = 10) for the novice. No adverse events were reported.Conclusions: A small number of cases were required for both expert and novice endoscopists to reach competency in the novel through‐the‐scope suture device.
Open AccessThe competency of the novel through‐the‐scope suture device for gastric mucosal defects: In vivo study in a porcine model (with video)
Objectives: Endoscopic closures of mucosal defects following endoscopic resection can be challenging and time‐consuming. The novel through‐the‐scope suture device has demonstrated acceptable closure times, but its learning curve is still unknown. This study aims to evaluate the number of cases required to achieve competency in this device.Methods: Two endoscopists participated; a novice with less than 400 experiences in upper gastrointestinal endoscopy and an expert with over 500 experiences in endoscopic submucosal dissection. Neither endoscopist had previous exposure to the device. In four porcine models, 24 gastric mucosal defects, each 2–4 cm in diameter, were created by endoscopic mucosal resection with ligation. Each endoscopist performed endoscopic closure for 12 mucosal defects with a single through‐the‐scope suture device per lesion. The primary endpoint was the number of cases needed to reach competency, defined as achieving a procedure time below the average closure time reported in the literature. Secondary endpoints included procedure time, complete closure success rates, and incidence of adverse events.Results: The mean defect size was 2.9 (±0.2) cm. Competency was achieved after six cases in the expert and seven cases in the novice. The median closure time was 9.0 (interquartile range [IQR]: 6.0–11.0) min for the expert and 8.0 (IQR: 6.2–9.7) min for the novice (p = 0.862). Complete closure success rates were 75.0% (n = 9) for the expert and 83.3% (n = 10) for the novice. No adverse events were reported.Conclusions: A small number of cases were required for both expert and novice endoscopists to reach competency in the novel through‐the‐scope suture device.
- Open Access
- 20 December 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 35 (4) , 529-537
Detection of colorectal adenomas with texture and color enhancement imaging: Multicenter observational study
Objectives: We aimed to evaluate the efficacy of texture and color enhancement imaging (TXI), which allows the acquisition of brighter images with enhanced color and surface structure in colorectal polyp detection compared to white light imaging.Methods: Patients who underwent colonoscopy with repeated ascending colon observation using TXI and white light imaging between August 2020 and January 2021 were identified in three institutions. The outcomes included the mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and ascending colonic adenoma miss rate (Ac‐AMR). Logistic regression was used to determine the effects of the variables on the outcomes.Results: We included 1043 lesions from 470 patients in the analysis. The MAP, ADR, flat polyp detection rate, and Ac‐AMR in TXI and white light imaging were 1.5% (95% confidence interval 1.3–1.6%) vs. 1.0% (0.9–1.1%), 58.2% (51.7–64.6%) vs. 46.8% (40.2–53.4%), 66.2% (59.8–72.2%) vs. 49.8% (43.2–56.4%), and 17.9% (12.1–25.2%) vs. 28.2% (20.0–37.6%), respectively. TXI, age, withdrawal time, and endoscopy type were identified as significant factors affecting the MAP and the ADR using multivariate regression analysis.Conclusions: Our study indicates that TXI improve the detection of colorectal neoplastic lesions. However, prospective randomized trials are required to confirm these findings.
- 20 December 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 35 (4) , 529-537
Open AccessDetection of colorectal adenomas with texture and color enhancement imaging: Multicenter observational study
Objectives: We aimed to evaluate the efficacy of texture and color enhancement imaging (TXI), which allows the acquisition of brighter images with enhanced color and surface structure in colorectal polyp detection compared to white light imaging.Methods: Patients who underwent colonoscopy with repeated ascending colon observation using TXI and white light imaging between August 2020 and January 2021 were identified in three institutions. The outcomes included the mean number of adenomas detected per procedure (MAP), adenoma detection rate (ADR), and ascending colonic adenoma miss rate (Ac‐AMR). Logistic regression was used to determine the effects of the variables on the outcomes.Results: We included 1043 lesions from 470 patients in the analysis. The MAP, ADR, flat polyp detection rate, and Ac‐AMR in TXI and white light imaging were 1.5% (95% confidence interval 1.3–1.6%) vs. 1.0% (0.9–1.1%), 58.2% (51.7–64.6%) vs. 46.8% (40.2–53.4%), 66.2% (59.8–72.2%) vs. 49.8% (43.2–56.4%), and 17.9% (12.1–25.2%) vs. 28.2% (20.0–37.6%), respectively. TXI, age, withdrawal time, and endoscopy type were identified as significant factors affecting the MAP and the ADR using multivariate regression analysis.Conclusions: Our study indicates that TXI improve the detection of colorectal neoplastic lesions. However, prospective randomized trials are required to confirm these findings.
- 2 June 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 34 (6) , 1134-1135
Bowel preparation for improving the quality of colonoscopy
- 2 June 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 34 (6) , 1134-1135
Bowel preparation for improving the quality of colonoscopy
- Open Access
- 16 February 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 34 (4) , 736-737
Can we efficiently learn a variety of classifications for the differentiation of colorectal polyps?
- 16 February 2022
- Published by Wiley in Digestive Endoscopy
- Vol. 34 (4) , 736-737
Open AccessCan we efficiently learn a variety of classifications for the differentiation of colorectal polyps?
- Open Access
Visibility evaluation of colorectal lesion using texture and color enhancement imaging with video
Objective: To evaluate the visibility of colorectal lesions using a novel image processing algorithm, texture and color enhancement imaging (TXI), that allows the acquisition of brighter images with enhanced color and surface structure.Methods: During August–September 2019, patients referred for endoscopic treatment were prospectively recruited. Electronic data acquired while observing colorectal lesions using white light imaging (WLI) were obtained and recorded: WLI, TXI mode1 (with color enhancement), and TXI mode2 (without color enhancement) videos were constructed. The lesions were also recorded using narrow‐band imaging (NBI) from the same perspective as WLI. Four video clips (WLI, TXI mode1, TXI mode2, and NBI) were made per lesion. Thereafter, video files for evaluations were prepared by randomly arranging all video clips. Finally, visualization scores were evaluated by four endoscopists, and the WLI, TXI mode1, TXI mode2, and NBI results were compared.Results: Overall, 22 patients with 68 lesions were recruited; the video file for evaluation subsequently comprised 272 randomly arranged video clips. Mean visualization scores using WLI, TXI mode1, TXI mode2, and NBI were 70.0 (±20.1), 80.5 (±18.6), 75.6 (±18.1), and 69.0 (±20.6), respectively. Mean visualization scores for flat lesions using WLI, TXI mode1, TXI mode2, and NBI were 64.1 (±21.2), 76.5 (±20.18), 71.8 (±19.4), and 64.2 (±22.0), respectively. Visualization scores using TXI mode1 were significantly better than those using WLI, TXI mode2, or NBI.Conclusions: TXI enables improved visualization of colorectal lesions, even flat lesions, than WLI and NBI. TXI may allow better detection of colorectal lesions, although further prospective studies are required.
Open AccessVisibility evaluation of colorectal lesion using texture and color enhancement imaging with video
Objective: To evaluate the visibility of colorectal lesions using a novel image processing algorithm, texture and color enhancement imaging (TXI), that allows the acquisition of brighter images with enhanced color and surface structure.Methods: During August–September 2019, patients referred for endoscopic treatment were prospectively recruited. Electronic data acquired while observing colorectal lesions using white light imaging (WLI) were obtained and recorded: WLI, TXI mode1 (with color enhancement), and TXI mode2 (without color enhancement) videos were constructed. The lesions were also recorded using narrow‐band imaging (NBI) from the same perspective as WLI. Four video clips (WLI, TXI mode1, TXI mode2, and NBI) were made per lesion. Thereafter, video files for evaluations were prepared by randomly arranging all video clips. Finally, visualization scores were evaluated by four endoscopists, and the WLI, TXI mode1, TXI mode2, and NBI results were compared.Results: Overall, 22 patients with 68 lesions were recruited; the video file for evaluation subsequently comprised 272 randomly arranged video clips. Mean visualization scores using WLI, TXI mode1, TXI mode2, and NBI were 70.0 (±20.1), 80.5 (±18.6), 75.6 (±18.1), and 69.0 (±20.6), respectively. Mean visualization scores for flat lesions using WLI, TXI mode1, TXI mode2, and NBI were 64.1 (±21.2), 76.5 (±20.18), 71.8 (±19.4), and 64.2 (±22.0), respectively. Visualization scores using TXI mode1 were significantly better than those using WLI, TXI mode2, or NBI.Conclusions: TXI enables improved visualization of colorectal lesions, even flat lesions, than WLI and NBI. TXI may allow better detection of colorectal lesions, although further prospective studies are required.