Yukihisa Suzuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yukihisa Suzuki has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Keiji Wada
Tokyo Metropolitan University
5 shared publications - Akira Ushiyama
Department of Environmental Health, National Institute of Public Health, Wako, Saitama, Japan
4 shared publications Masao Taki
Department of Electrical Engineering and Computer Science, Graduate School of Systems Design, Tokyo Metropolitan University, Hino, Tokyo, Japan
4 shared publicationsKeiji Wada
Graduate School of Systems Design, Tokyo Metropolitan University , 6-6 Asahigaoka, Hino, Tokyo, 191-0065
3 shared publications- Masami Kojima
Kanazawa Medical University, Kahoku, Ishikawa, Japan
3 shared publications - Masao Taki
Department of Electrical & Electronic Engineering, Graduate Schools of Science and Engineering, Tokyo Metropolitan University, 1-1, Hachioji, Tokyo 192-0397, Japan
3 shared publications
Latest Publications
- Open Access
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 214420-214429
Millimeter-Wave Beam Shaping for Biological Exposure Experiments Using a 265-GHz Gyrotron
This study develops an optical system for shaping 265 GHz high-power radiation from a gyrotron into well-defined beams for biological millimeter-wave exposure experiments on rabbit eye and skin samples. In the millimeter-wave region above 100 GHz, the gyrotron is the only available high-power radiation source. However, precise beam-shaping techniques required for reproducible exposure experiments have not yet been fully established for gyrotron radiation. To address this, this study employed phase-correcting mirrors, flat mirrors, a triaxial elliptical mirror, and two lens antennas to modify the beam size, intensity distribution, and polarization direction. A novel and simple smoothing procedure was introduced into the phase retrieval method to design the phase-correcting mirrors. An irradiation power control module was integrated into the optical system to monitor and stabilize the incident beam power. Two target beam configurations were required in the sample plane: an axisymmetric Gaussian beam with a full width at half maximum (FWHM) of approximately 4–6 mm and a broader beam with an FWHM of about 20 mm. Both target beams were required to be vertically linearly polarized. The radiation pattern, measured using an infrared camera, confirmed that the optical system met these requirements. This work establishes a fundamental technology for conducting biological exposure experiments using gyrotrons.
- 18 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 214420-214429
Open AccessMillimeter-Wave Beam Shaping for Biological Exposure Experiments Using a 265-GHz Gyrotron
This study develops an optical system for shaping 265 GHz high-power radiation from a gyrotron into well-defined beams for biological millimeter-wave exposure experiments on rabbit eye and skin samples. In the millimeter-wave region above 100 GHz, the gyrotron is the only available high-power radiation source. However, precise beam-shaping techniques required for reproducible exposure experiments have not yet been fully established for gyrotron radiation. To address this, this study employed phase-correcting mirrors, flat mirrors, a triaxial elliptical mirror, and two lens antennas to modify the beam size, intensity distribution, and polarization direction. A novel and simple smoothing procedure was introduced into the phase retrieval method to design the phase-correcting mirrors. An irradiation power control module was integrated into the optical system to monitor and stabilize the incident beam power. Two target beam configurations were required in the sample plane: an axisymmetric Gaussian beam with a full width at half maximum (FWHM) of approximately 4–6 mm and a broader beam with an FWHM of about 20 mm. Both target beams were required to be vertically linearly polarized. The radiation pattern, measured using an infrared camera, confirmed that the optical system met these requirements. This work establishes a fundamental technology for conducting biological exposure experiments using gyrotrons.
- Open Access
- 19 November 2025
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (1) , 1-10
Development and validation of an in vivo pain assessment method for 28-day exposure to intermediate frequency magnetic fields
The objective of this study was to establish guidelines for evaluating the health effects of electromagnetic fields (EMFs). To achieve this, a comprehensive evaluation of EMF effects on living organisms from both engineering and biological perspectives is essential. As part of this study, we examined the impact of intermediate-frequency magnetic fields (IF-MF) exposure on peripheral nerves in mice and validated the reliability of five pain assessment methods. The engineering approach was based on our pilot study, while the biological approach involved exposing mice to IF-MF for a 28-day period and assessing neurotoxicity through the implementation of five pain tests. The von Frey test, conducted with a Dynamic Plantar Aesthesiometer, was performed at various time points during exposure. The results indicated that leg withdrawal time was shortened only in the positive control group. After conducting a series of assessments, we demonstrated that no statistically significant differences were observed among the IF-MF-exposed, sham-exposed and control groups. However, the positive control group exhibited significant variations in the four supplemental assessments. No significant differences were detected in the other three groups. These findings suggest that subacute (28-day) IF-MF exposure at 2.3 times the basic restriction for occupational exposure according to International Commission on Non-Ionizing Radiation Protection guideline does not result in peripheral neurotoxicity and that the utilized pain assessment methods used for IF-MF exposure are effective.
- 19 November 2025
- Published by Oxford University Press (OUP) in Journal of Radiation Research
- Vol. 67 (1) , 1-10
Open AccessDevelopment and validation of an in vivo pain assessment method for 28-day exposure to intermediate frequency magnetic fields
The objective of this study was to establish guidelines for evaluating the health effects of electromagnetic fields (EMFs). To achieve this, a comprehensive evaluation of EMF effects on living organisms from both engineering and biological perspectives is essential. As part of this study, we examined the impact of intermediate-frequency magnetic fields (IF-MF) exposure on peripheral nerves in mice and validated the reliability of five pain assessment methods. The engineering approach was based on our pilot study, while the biological approach involved exposing mice to IF-MF for a 28-day period and assessing neurotoxicity through the implementation of five pain tests. The von Frey test, conducted with a Dynamic Plantar Aesthesiometer, was performed at various time points during exposure. The results indicated that leg withdrawal time was shortened only in the positive control group. After conducting a series of assessments, we demonstrated that no statistically significant differences were observed among the IF-MF-exposed, sham-exposed and control groups. However, the positive control group exhibited significant variations in the four supplemental assessments. No significant differences were detected in the other three groups. These findings suggest that subacute (28-day) IF-MF exposure at 2.3 times the basic restriction for occupational exposure according to International Commission on Non-Ionizing Radiation Protection guideline does not result in peripheral neurotoxicity and that the utilized pain assessment methods used for IF-MF exposure are effective.
- Open Access
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 86528-86541
Realistically Poseable Mouse Model for Assessing Exposures to Magnetic Field in the Intermediate Frequency Band
Recently, a mouse model was used to quantify electromagnetic (EM) dosimetry in an investigation of the biological effects of an EM field in the intermediate-frequency band (300 Hz to 10 MHz). However, it did not reflect the realistic postures observed during exposure experiments; thus, the data obtained were not accurate. In this study, a poseable mouse mesh model was developed using photogrammetry techniques; its pose was changed to mimic ten realistic postures observed during exposure experiments. The mouse model was composed of ten different tissues and organs: the eyes, brain, skull, bone, liver, lungs, heart, spleen, glands, and skin. The dosimetry evaluation was performed on the mouse model under a uniformly applied magnetic field intensity. The reliability and accuracy of the EM solver used in the evaluation were validated by performing a dosimetry evaluation on a homogeneous sphere and ellipsoid exposed to a uniform magnetic field; the results were compared with those obtained by the analytical method. Dosimetric quantification was performed using several metrics. The metrics included the whole-body average (EWBA), 99th percentile (E99), 99.9th percentile (E99.9), and maximum (Emax) values of the induced electric field intensity inside the mouse body. For an applied magnetic field density of 1 mT at 100 kHz, the EWBA, E99, E99.9, and Emax values for the poseable mouse in the standing, upright, and curled-up positions were derived and discussed. The developed poseable mouse model potentially provides accurate exposure data for animal experiments under freely roaming conditions.
- 12 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 86528-86541
Open AccessRealistically Poseable Mouse Model for Assessing Exposures to Magnetic Field in the Intermediate Frequency Band
Recently, a mouse model was used to quantify electromagnetic (EM) dosimetry in an investigation of the biological effects of an EM field in the intermediate-frequency band (300 Hz to 10 MHz). However, it did not reflect the realistic postures observed during exposure experiments; thus, the data obtained were not accurate. In this study, a poseable mouse mesh model was developed using photogrammetry techniques; its pose was changed to mimic ten realistic postures observed during exposure experiments. The mouse model was composed of ten different tissues and organs: the eyes, brain, skull, bone, liver, lungs, heart, spleen, glands, and skin. The dosimetry evaluation was performed on the mouse model under a uniformly applied magnetic field intensity. The reliability and accuracy of the EM solver used in the evaluation were validated by performing a dosimetry evaluation on a homogeneous sphere and ellipsoid exposed to a uniform magnetic field; the results were compared with those obtained by the analytical method. Dosimetric quantification was performed using several metrics. The metrics included the whole-body average (EWBA), 99th percentile (E99), 99.9th percentile (E99.9), and maximum (Emax) values of the induced electric field intensity inside the mouse body. For an applied magnetic field density of 1 mT at 100 kHz, the EWBA, E99, E99.9, and Emax values for the poseable mouse in the standing, upright, and curled-up positions were derived and discussed. The developed poseable mouse model potentially provides accurate exposure data for animal experiments under freely roaming conditions.
- Open Access
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 103941-103948
Suppression of Leakage Magnetic Fields in Wireless Power Transfer Using a Sandwich Structure
This study proposes a wireless power transfer (WPT) system using a sandwich structure comprising two transmitter coils and two receiver coils with distinct magnetic field configuration modes. The primary objective of this research is to suppress leakage magnetic fields while maintaining high power transfer efficiency. The results of the electromagnetic field analysis and experimental tests demonstrated that the magnetic field leakage of the differential–differential (DD) mode of the sandwich structure was significantly lower than that of the conventional structure, which employs a single coil pair and the cumulative–cumulative (CC) mode of the sandwich structure. Compared to the conventional and CC modes, the leakage magnetic field of the DD mode decreased by 10.1-12.3 dB at 1 m from the coils. This corresponds to suppressing the magnetic field leakage by approximately 76.0% compared to the conventional mode and 68.7% compared to the CC mode. These reductions were attributed to antiphase magnetic fields canceling each other in the DD mode. Moreover, the power transfer efficiency in the DD mode exceeds 95%. The proposed system was shown to effectively suppress electromagnetic interference without compromising transmission efficiency.
- 29 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 103941-103948
Open AccessSuppression of Leakage Magnetic Fields in Wireless Power Transfer Using a Sandwich Structure
This study proposes a wireless power transfer (WPT) system using a sandwich structure comprising two transmitter coils and two receiver coils with distinct magnetic field configuration modes. The primary objective of this research is to suppress leakage magnetic fields while maintaining high power transfer efficiency. The results of the electromagnetic field analysis and experimental tests demonstrated that the magnetic field leakage of the differential–differential (DD) mode of the sandwich structure was significantly lower than that of the conventional structure, which employs a single coil pair and the cumulative–cumulative (CC) mode of the sandwich structure. Compared to the conventional and CC modes, the leakage magnetic field of the DD mode decreased by 10.1-12.3 dB at 1 m from the coils. This corresponds to suppressing the magnetic field leakage by approximately 76.0% compared to the conventional mode and 68.7% compared to the CC mode. These reductions were attributed to antiphase magnetic fields canceling each other in the DD mode. Moreover, the power transfer efficiency in the DD mode exceeds 95%. The proposed system was shown to effectively suppress electromagnetic interference without compromising transmission efficiency.
- 7 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 23 (5) , 1593-1597
Novel Surface Impedance Formulation via FILT and Prony Method for FDTD Analyses of Lossy Media
Surface impedance method has been utilized in many electromagnetic problems involving high-loss media. In this letter, a new finite-difference time-domain formulation unified for the surface impedances of both metals and biological media is derived using the fast inverse Laplace transform (FILT) and the Prony method. The proposed formulation is capable of treating many kinds of surface impedance without in-advance knowledges of their analytical expressions in the time domain. It is demonstrated that the reflection coefficients of both metal and biological tissues calculated using our proposed formulation agree well with the theoretical values with errors less than 1.2% in the frequency range between 1 and 100 GHz, confirming the validity and effectiveness of the method.
- 7 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Antennas and Wireless Propagation Letters
- Vol. 23 (5) , 1593-1597
Novel Surface Impedance Formulation via FILT and Prony Method for FDTD Analyses of Lossy Media
Surface impedance method has been utilized in many electromagnetic problems involving high-loss media. In this letter, a new finite-difference time-domain formulation unified for the surface impedances of both metals and biological media is derived using the fast inverse Laplace transform (FILT) and the Prony method. The proposed formulation is capable of treating many kinds of surface impedance without in-advance knowledges of their analytical expressions in the time domain. It is demonstrated that the reflection coefficients of both metal and biological tissues calculated using our proposed formulation agree well with the theoretical values with errors less than 1.2% in the frequency range between 1 and 100 GHz, confirming the validity and effectiveness of the method.
- 3 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Magneto-Optical Probe With Integrated Optical Elements for Measuring Environmental Magnetic Fields in the Low- and Intermediate-Frequency Bands
In recent years, development of devices using magnetic fields in the low frequency bands (DC to 100 kHz) and intermediate frequency bands (300 Hz to 10 MHz) is progressing. The influence of magnetic fields generated from such devices on human body is drawing attention. Responding to the requirement to construct measurement system with ability to measure wide band frequency range for evaluating such magnetic fields, the authors have developed a prototype of the new measurement system, measuring environmental magnetic fields from DC to 20kHz, and confirmed its performance. It is confirmed that the output signal from the conventional magneto-optical probe (MO probe) fluctuates when the optical fiber cable is bent between the polarizer, probe, and analyzer. Therefore, it is proposed that the polarizer and analyzer are miniaturized and integrated into the body of MO probe, optical fiber cables inside the housing are fixed. The output signal from the new MO probe do not fluctuate when optical fiber cables outside the housing are bent. Furthermore, the measurement system using this MO probe is examined under applied magnetic fields from DC to 20kHz. Similar signals are observed both in voltage signals obtained by the new measurement system and in magnetic field signals measured by the Hall element type magnetic field probe. In addition, a comparison with existing sensors and an example of the application of this measurement system to the measurement of magnetic fields generated by power equipment are shown.
- 3 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Magneto-Optical Probe With Integrated Optical Elements for Measuring Environmental Magnetic Fields in the Low- and Intermediate-Frequency Bands
In recent years, development of devices using magnetic fields in the low frequency bands (DC to 100 kHz) and intermediate frequency bands (300 Hz to 10 MHz) is progressing. The influence of magnetic fields generated from such devices on human body is drawing attention. Responding to the requirement to construct measurement system with ability to measure wide band frequency range for evaluating such magnetic fields, the authors have developed a prototype of the new measurement system, measuring environmental magnetic fields from DC to 20kHz, and confirmed its performance. It is confirmed that the output signal from the conventional magneto-optical probe (MO probe) fluctuates when the optical fiber cable is bent between the polarizer, probe, and analyzer. Therefore, it is proposed that the polarizer and analyzer are miniaturized and integrated into the body of MO probe, optical fiber cables inside the housing are fixed. The output signal from the new MO probe do not fluctuate when optical fiber cables outside the housing are bent. Furthermore, the measurement system using this MO probe is examined under applied magnetic fields from DC to 20kHz. Similar signals are observed both in voltage signals obtained by the new measurement system and in magnetic field signals measured by the Hall element type magnetic field probe. In addition, a comparison with existing sensors and an example of the application of this measurement system to the measurement of magnetic fields generated by power equipment are shown.
- 1 November 2020
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E103C (11) , 609-612
Estimation of Switching Loss and Voltage Overshoot of Active Gate Driver by Neural Network
An active gate driver IC generates arbitrary switching waveform is proposed to reduce the switching loss, the voltage overshoot, and the electromagnetic interference (EMI) by optimizing the switching pattern. However, it is hard to find optimal switching pattern because the switching pattern has huge possible combinations. In this paper, the method to estimate the switching loss and the voltage overshoot from the switching pattern with neural network (NN) is proposed. The implemented NN model obtains reasonable learning results for data-sets.
- 1 November 2020
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E103C (11) , 609-612
Estimation of Switching Loss and Voltage Overshoot of Active Gate Driver by Neural Network
An active gate driver IC generates arbitrary switching waveform is proposed to reduce the switching loss, the voltage overshoot, and the electromagnetic interference (EMI) by optimizing the switching pattern. However, it is hard to find optimal switching pattern because the switching pattern has huge possible combinations. In this paper, the method to estimate the switching loss and the voltage overshoot from the switching pattern with neural network (NN) is proposed. The implemented NN model obtains reasonable learning results for data-sets.