Christopher Watterson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Christopher Watterson has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
- Andy M. Liu
Cedars Sinai Medical Center, Los Angeles, California
2 shared publications - David L. Skaggs
Department of Orthopaedic Surgery, Cedars Sinai Medical Center, Los Angeles, California
2 shared publications - Kenneth David Illingworth
Cedars Sinai Medical Center, Los Angeles, California
2 shared publications - Suhas K. Etigunta
Icahn School of Medicine at Mount Sinai, New York, NY, USA
2 shared publications - Angela Desmond
Division of Neonatal‐Perinatal Medicine, Department of Pediatrics UCLA Los Angeles California USA
1 shared publication - Ashley Elizabeth Prosper
Medical & Imaging Informatics, Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA
1 shared publication
Latest Publications
- 2 July 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Hematology/Oncology
- Vol. 48 (7) , e345-e348
Increased 18F-FDG Avidity on PET/CT During Treatment for Rhabdomyosarcoma Confirmed to Be Mature Rhabdomyoblasts
Background: Fluorine-18 fluorodeoxyglucose positron emission tomography ( 18 F-FDG-PET) is useful for staging rhabdomyosarcoma. Using this modality as a predictor of outcome and for disease surveillance in rhabdomyosarcoma is conflicting. Observations: Case report of an adolescent being treated for metastatic fusion-positive rhabdomyosarcoma who had a new 18 F-FDG-PET avid focus in the radiation field of the primary site with increasing standard uptake value during systemic chemotherapy and primary tumor local therapy that was worrisome for disease progression. Conclusions: This lesion was resected and confirmed as terminally cytodifferentiated (mature) rhabdomyoblasts on histopathology. He remains in remission 26 months following resection and 20 months following treatment.
- 2 July 2026
- Published by Wolters Kluwer Health in Journal of Pediatric Hematology/Oncology
- Vol. 48 (7) , e345-e348
Increased 18F-FDG Avidity on PET/CT During Treatment for Rhabdomyosarcoma Confirmed to Be Mature Rhabdomyoblasts
Background: Fluorine-18 fluorodeoxyglucose positron emission tomography ( 18 F-FDG-PET) is useful for staging rhabdomyosarcoma. Using this modality as a predictor of outcome and for disease surveillance in rhabdomyosarcoma is conflicting. Observations: Case report of an adolescent being treated for metastatic fusion-positive rhabdomyosarcoma who had a new 18 F-FDG-PET avid focus in the radiation field of the primary site with increasing standard uptake value during systemic chemotherapy and primary tumor local therapy that was worrisome for disease progression. Conclusions: This lesion was resected and confirmed as terminally cytodifferentiated (mature) rhabdomyoblasts on histopathology. He remains in remission 26 months following resection and 20 months following treatment.
- Open Access
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (2)
Magnetic Resonance Imaging–Generated Synthetic Computed Tomography in Pediatric Spine Patients
Background: Computed tomography (CT) and magnetic resonance imaging are common imaging studies used to evaluate pediatric spine patients. Novel MRI-generated synthetic CT (sCT) images have demonstrated near equivalence in accuracy when compared with traditional CT (tCT) in cadaveric studies. This recent advancement allows potential visualization of both bony and soft tissue anatomy without harmful ionizing radiation. To date, no literature reports the use of sCT in the evaluation of pediatric spinal pathologies. This study aimed to evaluate the clinical utility of sCT in managing pediatric and adolescent patients with various spinal conditions. Methods: This was a retrospective chart review of pediatric spine patients at a quaternary care hospital from October 2023 to September 2024. Inclusion criteria included any patients receiving a sCT for spinal evaluation. Patient demographics and imaging results were collected. For any patient with traditional CT (tCT) within 3 months of the sCT (n = 10), osseous anatomical measurements on the coronal, sagittal, and axial sequences were compared (10 total measurements per scan). Official radiology reads were also compared between sCT and tCT. Results: Twenty-five patients underwent sCT of the spine (2 cervical and 23 lumbar). Indications included rule out congenital cervical anomalies in congenital muscular torticollis (2 patients), spondylolysis (13), spondylolisthesis (2), scoliosis/back pain (4), chronic back pain (4), and back pain with transitional lumbosacral anatomy (4). A total of 176 measurements of spinal osseous anatomy were performed. Comparing tCT with sCT, 62.5% of the measurements differed by less than 0.5 mm, 95.5% by less than 1 mm, and 4.5% differed by 1 mm or more. Conclusion: sCT is a radiation-free alternative imaging modality for the evaluation of the osseous spine in children. sCT provides 3-dimensional imaging of the child’s bony anatomy, largely within 1 mm compared with a tCT. We believe sCT has significant clinical utility in the pediatric and adolescent population, allowing the diagnosis of both bony and soft tissue pathologies without exposing patients to radiation and using a single imaging study. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 April 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (2)
Open AccessMagnetic Resonance Imaging–Generated Synthetic Computed Tomography in Pediatric Spine Patients
Background: Computed tomography (CT) and magnetic resonance imaging are common imaging studies used to evaluate pediatric spine patients. Novel MRI-generated synthetic CT (sCT) images have demonstrated near equivalence in accuracy when compared with traditional CT (tCT) in cadaveric studies. This recent advancement allows potential visualization of both bony and soft tissue anatomy without harmful ionizing radiation. To date, no literature reports the use of sCT in the evaluation of pediatric spinal pathologies. This study aimed to evaluate the clinical utility of sCT in managing pediatric and adolescent patients with various spinal conditions. Methods: This was a retrospective chart review of pediatric spine patients at a quaternary care hospital from October 2023 to September 2024. Inclusion criteria included any patients receiving a sCT for spinal evaluation. Patient demographics and imaging results were collected. For any patient with traditional CT (tCT) within 3 months of the sCT (n = 10), osseous anatomical measurements on the coronal, sagittal, and axial sequences were compared (10 total measurements per scan). Official radiology reads were also compared between sCT and tCT. Results: Twenty-five patients underwent sCT of the spine (2 cervical and 23 lumbar). Indications included rule out congenital cervical anomalies in congenital muscular torticollis (2 patients), spondylolysis (13), spondylolisthesis (2), scoliosis/back pain (4), chronic back pain (4), and back pain with transitional lumbosacral anatomy (4). A total of 176 measurements of spinal osseous anatomy were performed. Comparing tCT with sCT, 62.5% of the measurements differed by less than 0.5 mm, 95.5% by less than 1 mm, and 4.5% differed by 1 mm or more. Conclusion: sCT is a radiation-free alternative imaging modality for the evaluation of the osseous spine in children. sCT provides 3-dimensional imaging of the child’s bony anatomy, largely within 1 mm compared with a tCT. We believe sCT has significant clinical utility in the pediatric and adolescent population, allowing the diagnosis of both bony and soft tissue pathologies without exposing patients to radiation and using a single imaging study. Level of Evidence: Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (1)
The Utilization of MRI-Generated Synthetic CT in the Treatment of Chronic Bilateral Spondylolysis
Case: A 14-year-old male athlete presented with a 9-month history of low back pain, worse with hyperextension. Nonoperative management for bilateral L4 spondylolysis had been unsuccessful. The patient underwent a novel magnetic resonance imaging (MRI) that generated a synthetic computed tomography (sCT). MRI/sCT revealed nonunion of the spondylolysis with persistent edema. The patient underwent minimally invasive bilateral L4 robot-navigated intralaminar screw fixation. CT at 3 months demonstrated complete healing. Conclusion: This case is the first to document the use of MRI-generated sCT in the management of pediatric spondylolysis, offering improved assessment of both bony and soft tissue pathology in a single study without the ionizing radiation of traditional CT.
- 1 January 2025
- Published by Wolters Kluwer Health in JBJS Case Connector
- Vol. 15 (1)
The Utilization of MRI-Generated Synthetic CT in the Treatment of Chronic Bilateral Spondylolysis
Case: A 14-year-old male athlete presented with a 9-month history of low back pain, worse with hyperextension. Nonoperative management for bilateral L4 spondylolysis had been unsuccessful. The patient underwent a novel magnetic resonance imaging (MRI) that generated a synthetic computed tomography (sCT). MRI/sCT revealed nonunion of the spondylolysis with persistent edema. The patient underwent minimally invasive bilateral L4 robot-navigated intralaminar screw fixation. CT at 3 months demonstrated complete healing. Conclusion: This case is the first to document the use of MRI-generated sCT in the management of pediatric spondylolysis, offering improved assessment of both bony and soft tissue pathology in a single study without the ionizing radiation of traditional CT.
- Open Access
- 21 November 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (22) , e030640
Integration of Prenatal Cardiovascular Magnetic Resonance Imaging in Congenital Heart Disease
Standard of care echocardiography can have limited diagnostic accuracy in certain cases of fetal congenital heart disease. Prenatal cardiovascular magnetic resonance (CMR) imaging has potential to provide additional anatomic imaging information, including excellent soft tissue images in multiple planes, improving prenatal diagnostics and in utero hemodynamic assessment. We conducted a literature review of fetal CMR, including its development and implementation into clinical practice, and compiled and analyzed the results. Our findings included the fact that technological and innovative approaches are required to overcome some of the challenges in fetal CMR, in part due to the dynamic nature of the fetal heart. A number of reconstruction algorithms and cardiac gating strategies have been developed over time to improve fetal CMR image quality, allowing unique investigations into fetal hemodynamics, oxygenation, and growth. Studies demonstrate that incorporating CMR in the prenatal arena influences postnatal clinical management. With further refinement and experience, fetal CMR in congenital heart disease continues to evolve and demonstrate ongoing potential as a complementary imaging modality to fetal echocardiography in the care of these patients.
- 21 November 2023
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 12 (22) , e030640
Open AccessIntegration of Prenatal Cardiovascular Magnetic Resonance Imaging in Congenital Heart Disease
Standard of care echocardiography can have limited diagnostic accuracy in certain cases of fetal congenital heart disease. Prenatal cardiovascular magnetic resonance (CMR) imaging has potential to provide additional anatomic imaging information, including excellent soft tissue images in multiple planes, improving prenatal diagnostics and in utero hemodynamic assessment. We conducted a literature review of fetal CMR, including its development and implementation into clinical practice, and compiled and analyzed the results. Our findings included the fact that technological and innovative approaches are required to overcome some of the challenges in fetal CMR, in part due to the dynamic nature of the fetal heart. A number of reconstruction algorithms and cardiac gating strategies have been developed over time to improve fetal CMR image quality, allowing unique investigations into fetal hemodynamics, oxygenation, and growth. Studies demonstrate that incorporating CMR in the prenatal arena influences postnatal clinical management. With further refinement and experience, fetal CMR in congenital heart disease continues to evolve and demonstrate ongoing potential as a complementary imaging modality to fetal echocardiography in the care of these patients.
- 1 May 2018
- Published by Elsevier in Clinical Imaging
- Vol. 49, 106-110
Case of urethral duplication seen by voiding urosonography
- 1 May 2018
- Published by Elsevier in Clinical Imaging
- Vol. 49, 106-110
Case of urethral duplication seen by voiding urosonography
- 1 February 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (3) , 421-426
High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents
BACKGROUND AND PURPOSE: In view of the recent observations that gadolinium deposits in brain tissue after intravenous injection, our aim of this study was to compare signal changes in the globus pallidus and dentate nucleus on unenhanced T1-weighted MR images in patients receiving serial doses of gadobutrol, a macrocyclic gadolinium-based contrast agent, with those seen in patients receiving linear gadolinium-based contrast agents. MATERIALS AND METHODS: This was a retrospective analysis of on-site patients with brain tumors. Fifty-nine patients received only gadobutrol, and 60 patients received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenate dimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus, dentate nucleus, and pons was measured on the precontrast portions of patients9 first and seventh brain MRIs. Ratios of signal intensity comparing the globus pallidus with the pons (globus pallidus/pons) and dentate nucleus with the pons (dentate nucleus/pons) were calculated. Changes in the above signal intensity ratios were compared within the gadobutrol and linear agent groups, as well as between groups. RESULTS: The dentate nucleus/pons signal ratio increased in the linear gadolinium-based contrast agent group (t = 4.215, P < .001), while no significant increase was seen in the gadobutrol group (t = −1.422, P = .08). The globus pallidus/pons ratios followed similarly, with an increase in the linear gadolinium-based contrast agent group (t = 2.931, P < .0001) and no significant change in those receiving gadobutrol (t = 0.684, P = .25). CONCLUSIONS: Successive doses of gadobutrol do not result in T1 shortening compared with changes seen in linear gadolinium-based contrast agents.
- 1 February 2018
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 39 (3) , 421-426
High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents
BACKGROUND AND PURPOSE: In view of the recent observations that gadolinium deposits in brain tissue after intravenous injection, our aim of this study was to compare signal changes in the globus pallidus and dentate nucleus on unenhanced T1-weighted MR images in patients receiving serial doses of gadobutrol, a macrocyclic gadolinium-based contrast agent, with those seen in patients receiving linear gadolinium-based contrast agents. MATERIALS AND METHODS: This was a retrospective analysis of on-site patients with brain tumors. Fifty-nine patients received only gadobutrol, and 60 patients received only linear gadolinium-based contrast agents. Linear gadolinium-based contrast agents included gadoversetamide, gadobenate dimeglumine, and gadodiamide. T1 signal intensity in the globus pallidus, dentate nucleus, and pons was measured on the precontrast portions of patients9 first and seventh brain MRIs. Ratios of signal intensity comparing the globus pallidus with the pons (globus pallidus/pons) and dentate nucleus with the pons (dentate nucleus/pons) were calculated. Changes in the above signal intensity ratios were compared within the gadobutrol and linear agent groups, as well as between groups. RESULTS: The dentate nucleus/pons signal ratio increased in the linear gadolinium-based contrast agent group (t = 4.215, P < .001), while no significant increase was seen in the gadobutrol group (t = −1.422, P = .08). The globus pallidus/pons ratios followed similarly, with an increase in the linear gadolinium-based contrast agent group (t = 2.931, P < .0001) and no significant change in those receiving gadobutrol (t = 0.684, P = .25). CONCLUSIONS: Successive doses of gadobutrol do not result in T1 shortening compared with changes seen in linear gadolinium-based contrast agents.
- 1 April 2015
- Published by Elsevier in Gastroenterology
- Vol. 148 (4)
Mo1630 Length of Bowel Distal to a Diverting Ileostomy (DI) Does Not Influence the Risk of Dehydration After Ileal Pouch-Anal Anastomosis (IPAA)
- 1 April 2015
- Published by Elsevier in Gastroenterology
- Vol. 148 (4)
Mo1630 Length of Bowel Distal to a Diverting Ileostomy (DI) Does Not Influence the Risk of Dehydration After Ileal Pouch-Anal Anastomosis (IPAA)