CYCherng Hui Mbbs Vivien Yip

Cherng Hui Mbbs Vivien Yip

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cherng Hui Mbbs Vivien Yip has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Comparison of Efficacy and Safety of XEN45 Implant Versus Trabeculectomy in Asian Eyes

    by Ae Ra Mbbs Kee, Cherng Hui Mbbs Vivien Yip, Chun Hau Bsc Chua, Chin Hou Mbbs Bryan Ang, Youwei Mbbs Jeremy Hu, Xiner MBChB Guo, Wei Leon MBChB Leonard Yip

    Précis: Combined phacoemulsification and trabeculectomy is able to achieve greater reduction in intraocular pressure (IOP), higher rates of complete surgical success and fewer postoperative manipulations and visits compared with combined phacoemulsification and Xen implantation in glaucomatous eyes. Purpose: Our study aims to compare and understand the differences between the efficacy and safety of XEN45 implantation and trabeculectomy in Asian eyes with glaucoma. Materials and Methods: This was a retrospective, single-center, comparative study of consecutive patients who underwent combined phacoemulsification and trabeculectomy (Phaco-Trab) from January 2013 to June 2014 and combined phacoemulsification and XEN45 implantation (Phaco-Xen) from May 2017 to September 2018 in a tertiary Ophthalmology center in Singapore. Outcome measures included IOP, number of anti-glaucoma eyedrops, success rate, factors leading to success/failure, number of postoperative interventions and visits required, and surgical complications. Results: A total of 137 eyes (91 Phaco-Trab, 46 Phaco-Xen) were included. Phaco-Trab group had greater mean IOP reduction at all time points beyond postoperative month (POM) 1 (mean difference 2.9 to 3.8 mm Hg; PPP=0.009), with only a mean of 0.1 bleb interventions required per patient, versus 1.5 in Phaco-Xen group (P<0.001). Safety profiles in both groups were comparable, with no statistically significant difference in intraoperative/postoperative complications. Conclusion: Phaco-Trab has significantly higher reduction in both IOP and number of antiglaucoma medications compared with Phaco-Xen group, with greater surgical success and fewer postoperative manipulations and visits. Safety profiles were comparable.


  • Open Access

    Comparison of two different optical coherence tomography angiography devices in detecting healthy versus glaucomatous eyes – an observational cross-sectional study

    by A. R. Kee, V. C. H. Yip, E. L. T. Tay, C. W. Lim, J. Cheng, H. Y. Teo, C. H. Chua, L. W. L. Yip

    Background: To understand the differences between two different optical coherence tomography angiography (OCTA) devices in detecting glaucomatous from healthy eyes by comparing their vascular parameters, diagnostic accuracy and test-retest reliability. Methods: A cross-sectional observational study was performed on healthy and glaucoma subjects, on whom two sets of OCTA images of optic disc and macula were acquired using both AngioVue (Optovue, USA) and Swept Source (Topcon, Japan) OCTA devices during one visit. A novel in-house software was used to calculate the vessel densities. Diagnostic accuracy of the machines in differentiating healthy versus glaucomatous eyes was determined using area under the receiver operating characteristic curve (AUROC) and test-retest repeatability of the machines was also evaluated. Results: A total of 80 healthy and 38 glaucomatous eyes were evaluated. Glaucomatous eyes had reduced mean vessel density compared to healthy controls in all segmented layers of the optic disc and macula using AngioVue (p ≤ 0.001). However, glaucomatous eyes had higher mean vessel density on optic disc scans using Swept Source, with lack of statistically significant difference between healthy and glaucomatous eyes. The AUROC showed better diagnostic accuracy of AngioVue (0.761–1.000) compared to Swept Source (0.113–0.644). The test-retest reliability indices were generally better using AngioVue than Swept Source. Conclusions: AngioVue showed better diagnostic capability and test-retest reliability compared to Swept Source. Further studies need to be undertaken to evaluate if there is any significant difference between the various machines in diagnosing and monitoring glaucoma.