Liang Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Liang Sun has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Min Yang
School of Mechanical Engineering and Automation, Beijing University of Aeronautics and Astronautics, Beijing, China
2 shared publications- Min Yang
School of Mechanical Engineering and Automation, Beihang University, Beijing, China
2 shared publications - Qiang Lin
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China
2 shared publications - Chao Hai
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, China
1 shared publication - Chao Hai
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, People’s Republic of China
1 shared publication Dalong Tan
School of Mechanical Engineering and Automation, Beihang University, Beijing 100191, People’s Republic of China
1 shared publication
Latest Publications
- 10 November 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (2) , 025402
Deformation measurement within lithium-ion battery using sparse-view computed tomography and digital image correlation
Electrode deformation can cause high local strain and serious capacity degradation in lithium-ion batteries (LIBs) during cycling. Risk reduction in many applications requires an understanding of the effects of the charging/discharging rate on the electrode structure during the battery life cycle. Cyclic charging/discharging experiments of wound 18 650 cylindrical LIBs were conducted at different charging/discharging rates (1C and 2C) to determine the effect of rate on electrode deformation. The charging/discharging capacity as well as battery voltage and time were analyzed during cycling. To acquire electrode deformation images and meet the requirements of computed tomography (CT) within 2 min during the charging/discharging process, sparse-view CT was performed at fixed cycle intervals. Subsequently, a sparse-view reconstruction network was proposed to generate a slice image. Finally, the electrode displacement and strain fields were calculated using the augmented Lagrangian digital image correlation algorithm. The causes of electrode deformation were analyzed and discussed from the perspective of molecular and macroscopic structure. Experimental results show that the structural similarity, peak signal-to-noise ratio and root mean square error in the reconstructed image of the axial section within the battery obtained via the proposed network were 0.9616, 38.7411 dB and 0.0108, respectively, which were better than the other methods of comparison. After 100 cycles, the capacity decay of the battery at 2C was 9.23-fold higher than that at 1C. After 100 cycles at 2C, the maximum displacement of the electrode reached 0.46 mm along the x-direction. The electrode structural deformation of the battery can be intuitively understood at different rates, which facilitates reasonable utilization and structural optimization of the battery.
- 10 November 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (2) , 025402
Deformation measurement within lithium-ion battery using sparse-view computed tomography and digital image correlation
Electrode deformation can cause high local strain and serious capacity degradation in lithium-ion batteries (LIBs) during cycling. Risk reduction in many applications requires an understanding of the effects of the charging/discharging rate on the electrode structure during the battery life cycle. Cyclic charging/discharging experiments of wound 18 650 cylindrical LIBs were conducted at different charging/discharging rates (1C and 2C) to determine the effect of rate on electrode deformation. The charging/discharging capacity as well as battery voltage and time were analyzed during cycling. To acquire electrode deformation images and meet the requirements of computed tomography (CT) within 2 min during the charging/discharging process, sparse-view CT was performed at fixed cycle intervals. Subsequently, a sparse-view reconstruction network was proposed to generate a slice image. Finally, the electrode displacement and strain fields were calculated using the augmented Lagrangian digital image correlation algorithm. The causes of electrode deformation were analyzed and discussed from the perspective of molecular and macroscopic structure. Experimental results show that the structural similarity, peak signal-to-noise ratio and root mean square error in the reconstructed image of the axial section within the battery obtained via the proposed network were 0.9616, 38.7411 dB and 0.0108, respectively, which were better than the other methods of comparison. After 100 cycles, the capacity decay of the battery at 2C was 9.23-fold higher than that at 1C. After 100 cycles at 2C, the maximum displacement of the electrode reached 0.46 mm along the x-direction. The electrode structural deformation of the battery can be intuitively understood at different rates, which facilitates reasonable utilization and structural optimization of the battery.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Design of Imaging System and Tomography Detection Method for Radial Tires Structure Under X-Ray Short-Scan Mode
X-ray computed tomography (CT) is a widely popular non-destructive testing (NDT) technology for engineering, which also plays an important role in the NDT testing for radial tires. The steel wires in radial tires are densely arranged and regularly distributed, which usually need high-energy X-rays to penetrate completely. Due to the limitation of tire size and mechanical structure, it is sometimes impossible to scan full-360-degree. In this paper, a scheme of alternating short-scan tomography for circumferential slices on one side of the tire is proposed, and a set of special X-ray NDT instrumentation for radial tires is developed. This solution solves the problem of transilluminating the entire tire in traditional CT scans, and can effectively reduce the maximum penetration energy and radiation dose. Furthermore, the winding problem of high voltage cable and oil cooling service pipeline in the process of rotation is well avoided. Then, a short-scan CT reconstruction method with the offset rotation center is deduced, which can effectively eliminate the image artifacts caused by the connection line between the rotating center of the turntable and the focus of the ray source is not perpendicular to the imaging plane of the detector. Computer simulations and experimental results prove the correctness of the proposed compensation symmetry filling reconstruction algorithm. The proposed method can effectively improve the reconstruction accuracy and suppress the reconstruction artifacts. Based on this, the requirements of mechanical assembly precision can be relaxed, which has a certain engineering significance.
- 8 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-12
Design of Imaging System and Tomography Detection Method for Radial Tires Structure Under X-Ray Short-Scan Mode
X-ray computed tomography (CT) is a widely popular non-destructive testing (NDT) technology for engineering, which also plays an important role in the NDT testing for radial tires. The steel wires in radial tires are densely arranged and regularly distributed, which usually need high-energy X-rays to penetrate completely. Due to the limitation of tire size and mechanical structure, it is sometimes impossible to scan full-360-degree. In this paper, a scheme of alternating short-scan tomography for circumferential slices on one side of the tire is proposed, and a set of special X-ray NDT instrumentation for radial tires is developed. This solution solves the problem of transilluminating the entire tire in traditional CT scans, and can effectively reduce the maximum penetration energy and radiation dose. Furthermore, the winding problem of high voltage cable and oil cooling service pipeline in the process of rotation is well avoided. Then, a short-scan CT reconstruction method with the offset rotation center is deduced, which can effectively eliminate the image artifacts caused by the connection line between the rotating center of the turntable and the focus of the ray source is not perpendicular to the imaging plane of the detector. Computer simulations and experimental results prove the correctness of the proposed compensation symmetry filling reconstruction algorithm. The proposed method can effectively improve the reconstruction accuracy and suppress the reconstruction artifacts. Based on this, the requirements of mechanical assembly precision can be relaxed, which has a certain engineering significance.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (11) , 2574-2586
A New CL Reconstruction Method Under the Displaced Sample Stage Scanning Mode
X-ray computed laminography (CL), as a popular nondestructive testing technology, has unique advantages for the detection of plate-type structures. However, with the limitation of the detector size, the specimen, i.e., large flat-like components, may be beyond the field of view (FOV) of the CL system. For the cone-beam computed tomography (CBCT) system, which is analogous to the CL system, a traditional way to enlarge the FOV is the displaced sample stage scanning mode. In this article, a new CL reconstruction method with the displaced sample stage scanning mode is proposed to enlarge the FOV of the CL system. According to this method, a virtual detector is established to obtain a new CBCT system under the displaced sample stage. Then, the projection data are converted into the virtual detector and scanning geometric parameters are calculated. The Feldkamp–Davis–Kress (FDK) algorithm combined with the Parker weighting function can well reconstruct the cross sections of the specimen with acceptable quality. The numerical simulation and experiments demonstrate that the proposed approach can achieve image reconstruction with sufficient quality and low computational cost. The FOV of the CL system is enlarged effectively without changing the original scanning geometry, and thereby, it can be conveniently utilized in engineering applications.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (11) , 2574-2586
A New CL Reconstruction Method Under the Displaced Sample Stage Scanning Mode
X-ray computed laminography (CL), as a popular nondestructive testing technology, has unique advantages for the detection of plate-type structures. However, with the limitation of the detector size, the specimen, i.e., large flat-like components, may be beyond the field of view (FOV) of the CL system. For the cone-beam computed tomography (CBCT) system, which is analogous to the CL system, a traditional way to enlarge the FOV is the displaced sample stage scanning mode. In this article, a new CL reconstruction method with the displaced sample stage scanning mode is proposed to enlarge the FOV of the CL system. According to this method, a virtual detector is established to obtain a new CBCT system under the displaced sample stage. Then, the projection data are converted into the virtual detector and scanning geometric parameters are calculated. The Feldkamp–Davis–Kress (FDK) algorithm combined with the Parker weighting function can well reconstruct the cross sections of the specimen with acceptable quality. The numerical simulation and experiments demonstrate that the proposed approach can achieve image reconstruction with sufficient quality and low computational cost. The FOV of the CL system is enlarged effectively without changing the original scanning geometry, and thereby, it can be conveniently utilized in engineering applications.
- 15 February 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (4) , 045403
A reconstruction method for cone-beam computed laminography based on projection transformation
X-ray computed tomography (CT) is a widely popular nondestructive testing technique for engineering and medical purposes, but its limitation is openly recognized in the inspection of large components, particularly for plate-type structures. Computed laminography (CL) avoids this defect. Nowadays, most of the existing analytical CL reconstruction approaches ignore the problem that the projection data under the CL scanning structure does not strictly meet the conditions of the standard filtered back-projection (FBP) or Feldkamp–Davis–Kress (FDK) method. Since the original CL data are directly filtered without considering the influence of the tilt angle of the CL rotation axis, this will affect the quality of the reconstructed images. In view of this situation, a conversion method of cone-beam CL data based on projection transformation is proposed, which is also referred to as the CL re-projection (CLRP). The collected CL projections can be corrected to satisfy the filtering requirements. We establish a virtual CT detector and use the CLRP to convert the known CL data into the projection on the virtual detector. Then, the FDK method commonly used in cone-beam CT is applied to reconstruct the converted data. Through the above two steps to achieve CL reconstruction. Computer simulations and experimental results show that the CLRP algorithm can accurately convert the raw CL data into those which satisfying the FDK method. The CLRP can decline the information aliasing to a certain extent. Compared with the existing CL-FBP algorithm, the CLRP-FDK method for CL reconstruction can effectively reduce image artifacts. The CLRP algorithm provides a new idea for CL reconstruction and plays an important role in practical engineering applications.
- 15 February 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (4) , 045403
A reconstruction method for cone-beam computed laminography based on projection transformation
X-ray computed tomography (CT) is a widely popular nondestructive testing technique for engineering and medical purposes, but its limitation is openly recognized in the inspection of large components, particularly for plate-type structures. Computed laminography (CL) avoids this defect. Nowadays, most of the existing analytical CL reconstruction approaches ignore the problem that the projection data under the CL scanning structure does not strictly meet the conditions of the standard filtered back-projection (FBP) or Feldkamp–Davis–Kress (FDK) method. Since the original CL data are directly filtered without considering the influence of the tilt angle of the CL rotation axis, this will affect the quality of the reconstructed images. In view of this situation, a conversion method of cone-beam CL data based on projection transformation is proposed, which is also referred to as the CL re-projection (CLRP). The collected CL projections can be corrected to satisfy the filtering requirements. We establish a virtual CT detector and use the CLRP to convert the known CL data into the projection on the virtual detector. Then, the FDK method commonly used in cone-beam CT is applied to reconstruct the converted data. Through the above two steps to achieve CL reconstruction. Computer simulations and experimental results show that the CLRP algorithm can accurately convert the raw CL data into those which satisfying the FDK method. The CLRP can decline the information aliasing to a certain extent. Compared with the existing CL-FBP algorithm, the CLRP-FDK method for CL reconstruction can effectively reduce image artifacts. The CLRP algorithm provides a new idea for CL reconstruction and plays an important role in practical engineering applications.
- 29 June 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part30) , 3581
MO‐F‐CAMPUS‐T‐04: Utilization of Optical Dosimeter for Modulated Spot‐Scanning Particle Beam
Purpose: To present the utilization of an optical dosimeter for modulated spot‐scanning carbon‐ion and proton beams during the acceptance test of Siemens IONTRIS system.Method and Materials: An optical dosimeter using phosphor scintillation was developed to map and interactively analyze the shapes and sizes of spots over 190 energies for ProTom modulated‐scanning system. The dose response to proton had been characterized with proper pixel calibration at ProTom system. The dose response was further studied at 0.7 cm depths by uniform 8cm in‐diameter fields of 424.89 MeV/u (E290) carbon‐ions and 215.18MeV (E282) protons at IONTRIS system. The virtual source axial distances (vSAD) of carbonions and protons of IONTRIS system was investigated by measuring either variations of spot position or field size at five different locations to Isocenter. By measuring lateral profiles of uniform doses with varied thin‐thicknesses of chest‐board pattern and placing the scintillation plate at near to the distal edge, range variations at different off‐axis‐distances (rOAD) were examined. Relative accuracy and reproducibility of beam range were measured for three beam ranges with a ramping block at front of scintillation plate.Results: Similar dose response was observed for high energies of carbon ions and protons. Mean vSAD at X and Y axes were 744.1 cm and 807.4cm with deviation of 7.4cm and 7.7cm, respectively. Variation of rOAD was within 0.35 mm over 10cm for both protons and carbon ions. Accuracy of measuring relative distal range using the ramping block was 0.2mm. Measured range over repeated three times for each range were within 0.25mm at same room, and within 1.0mm between four rooms.Conclusions: The optical dosimeter could efficiently measure the virtual source distance. And, to measure small range variation at different off‐axial locations, and for the relative beam range between rooms during acceptance test of a modulated spot‐scanning particle system.
- 29 June 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part30) , 3581
MO‐F‐CAMPUS‐T‐04: Utilization of Optical Dosimeter for Modulated Spot‐Scanning Particle Beam
Purpose: To present the utilization of an optical dosimeter for modulated spot‐scanning carbon‐ion and proton beams during the acceptance test of Siemens IONTRIS system.Method and Materials: An optical dosimeter using phosphor scintillation was developed to map and interactively analyze the shapes and sizes of spots over 190 energies for ProTom modulated‐scanning system. The dose response to proton had been characterized with proper pixel calibration at ProTom system. The dose response was further studied at 0.7 cm depths by uniform 8cm in‐diameter fields of 424.89 MeV/u (E290) carbon‐ions and 215.18MeV (E282) protons at IONTRIS system. The virtual source axial distances (vSAD) of carbonions and protons of IONTRIS system was investigated by measuring either variations of spot position or field size at five different locations to Isocenter. By measuring lateral profiles of uniform doses with varied thin‐thicknesses of chest‐board pattern and placing the scintillation plate at near to the distal edge, range variations at different off‐axis‐distances (rOAD) were examined. Relative accuracy and reproducibility of beam range were measured for three beam ranges with a ramping block at front of scintillation plate.Results: Similar dose response was observed for high energies of carbon ions and protons. Mean vSAD at X and Y axes were 744.1 cm and 807.4cm with deviation of 7.4cm and 7.7cm, respectively. Variation of rOAD was within 0.35 mm over 10cm for both protons and carbon ions. Accuracy of measuring relative distal range using the ramping block was 0.2mm. Measured range over repeated three times for each range were within 0.25mm at same room, and within 1.0mm between four rooms.Conclusions: The optical dosimeter could efficiently measure the virtual source distance. And, to measure small range variation at different off‐axial locations, and for the relative beam range between rooms during acceptance test of a modulated spot‐scanning particle system.