Sander Ruiter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sander Ruiter has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Anjoeka Pronk
Unit Healthy Living and Work, Department Risk Assessment for Products in Development, Netherlands Organization for Applied Scientific Research (TNO), Utrecht, The Netherlands
2 shared publicationsEelco Kuijpers
Unit Healthy Living and Work, Department Risk Assessment for Products in Development, Netherlands Organization for Applied Scientific Research (TNO), Utrecht, The Netherlands
2 shared publications- Anjoeka Pronk
Nederlandse Organisatie voor Toegepast Natuurwetenschappelijk Onderzoek, Utrecht, the Netherlands
1 shared publication Delphine Bard
Health and Safety Executive (HSE), HSE Science and Research Centre , Harpur Hill, Buxton SK17 9JN , UK
1 shared publication- Delphine Bard
Health and Safety Executive (HSE) Science Division , Harpur Hill, Buxton SK 17 9JN, Buxton
1 shared publication - Eelco Kuijpers
Netherlands Organization for Applied Scientific Research (TNO), 3584 CB Utrecht, The Netherlands
1 shared publication
Latest Publications
- 29 August 2024
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 21 (10) , 696-708
Spatiotemporal modeling of occupational particulate matter using personal low-cost sensor and indoor location tracking data
Occupational exposure to particulate matter (PM) can result in multiple adverse health effects and should be minimized to protect workers' health. PM exposure at the workplace can be complex with many potential sources and fluctuations over time, making it difficult to control. Dynamic maps that visualize how PM is distributed throughout a workplace over time can help in gaining better insights into when and where exposure occurs. This study explored the use of spatiotemporal modeling followed by kriging for the development of dynamic PM concentration maps in an experimental setting and a workplace setting. Data was collected using personal low-cost PM sensors and an indoor location tracking system, mounted on a moving robot or worker. Maps were generated for an experimental study with one simulated robot worker and a workplace study with four workers. Cross-validation was performed to evaluate the performance and robustness of three types of spatiotemporal models (metric, separable, and summetric) and, as an additional external validation, model estimates were compared with measurements from sensors that were placed stationary in the laboratory or workplace. Spatiotemporal models and maps were generated for both the experimental and workplace studies, with average root mean squared error (RMSE) from 10-fold cross-validation ranging from 7-12 and 73-127 mu g/m(3), respectively. Workplace models were relatively more robust compared to the experimental study (relative SD ranging from 8-14% of the average RMSE vs. 27-56%, respectively), presumably due to the larger number of parallel measurements. Model estimates showed low to moderate fits compared to stationary sensor measurements (R(2 )ranging from 0.1-0.5), indicating maps should be interpreted with caution and only used indicatively. Together, these findings show the feasibility of using spatiotemporal modeling for generating dynamic concentration maps based on personal data. The described method could be applied for exposure characterization within comparable study designs or can be expanded further, for example by developing real-time, location-based worker feedback systems, as efficient tools to visualize and communicate exposure risks.
- 29 August 2024
- Published by Taylor & Francis in Journal of Occupational and Environmental Hygiene
- Vol. 21 (10) , 696-708
Spatiotemporal modeling of occupational particulate matter using personal low-cost sensor and indoor location tracking data
Occupational exposure to particulate matter (PM) can result in multiple adverse health effects and should be minimized to protect workers' health. PM exposure at the workplace can be complex with many potential sources and fluctuations over time, making it difficult to control. Dynamic maps that visualize how PM is distributed throughout a workplace over time can help in gaining better insights into when and where exposure occurs. This study explored the use of spatiotemporal modeling followed by kriging for the development of dynamic PM concentration maps in an experimental setting and a workplace setting. Data was collected using personal low-cost PM sensors and an indoor location tracking system, mounted on a moving robot or worker. Maps were generated for an experimental study with one simulated robot worker and a workplace study with four workers. Cross-validation was performed to evaluate the performance and robustness of three types of spatiotemporal models (metric, separable, and summetric) and, as an additional external validation, model estimates were compared with measurements from sensors that were placed stationary in the laboratory or workplace. Spatiotemporal models and maps were generated for both the experimental and workplace studies, with average root mean squared error (RMSE) from 10-fold cross-validation ranging from 7-12 and 73-127 mu g/m(3), respectively. Workplace models were relatively more robust compared to the experimental study (relative SD ranging from 8-14% of the average RMSE vs. 27-56%, respectively), presumably due to the larger number of parallel measurements. Model estimates showed low to moderate fits compared to stationary sensor measurements (R(2 )ranging from 0.1-0.5), indicating maps should be interpreted with caution and only used indicatively. Together, these findings show the feasibility of using spatiotemporal modeling for generating dynamic concentration maps based on personal data. The described method could be applied for exposure characterization within comparable study designs or can be expanded further, for example by developing real-time, location-based worker feedback systems, as efficient tools to visualize and communicate exposure risks.
- 6 January 2023
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 67 (3) , 379-391
Exposure Monitoring Strategies for Applying Low-Cost PM Sensors to Assess Flour Dust in Industrial Bakeries
Low-cost particulate matter (PM) sensors provide new methods for monitoring occupational exposure to hazardous substances, such as flour dust. These devices have many possible benefits, but much remains unknown about their performance for different exposure monitoring strategies in the workplace. We explored the performance of PM sensors for four different monitoring strategies (time-weighted average and high time resolution, each quantitative and semi-quantitative) for assessing occupational exposure using low-cost PM sensors in a field study in the industrial bakery sector. Measurements were collected using four types of sensor (PATS+, Isensit, Airbeam2, and Munisense) and two reference devices (respirable gravimetric samplers and an established time-resolved device) at two large-scale bakeries, spread over 11 participants and 6 measurement days. Average PM2.5 concentrations of the low-cost sensors were compared with gravimetric respirable concentrations for 8-h shift periods and 1-min PM2.5 concentrations of the low-cost sensors were compared with time-resolved PM2.5 data from the reference device (quantitative monitoring strategy). Low-cost sensors were also ranked in terms of exposure for 8-h shifts and for 15-min periods with a shift (semi-quantitative monitoring strategy). Environmental factors and methodological variables, which can affect sensor performance, were investigated. Semi-quantitative monitoring strategies only showed more accurate results compared with quantitative strategies when these were based on shift-average exposures. The main factors that influenced sensor performance were the type of placement (positioning the devices stationary versus personal) and the company or workstation where measurements were collected. Together, these findings provide an overview of common strengths and drawbacks of low-cost sensors and different ways these can be applied in the workplace. This can be used as a starting point for further investigations and the development of guidance documents and data analysis methods.
- 6 January 2023
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 67 (3) , 379-391
Exposure Monitoring Strategies for Applying Low-Cost PM Sensors to Assess Flour Dust in Industrial Bakeries
Low-cost particulate matter (PM) sensors provide new methods for monitoring occupational exposure to hazardous substances, such as flour dust. These devices have many possible benefits, but much remains unknown about their performance for different exposure monitoring strategies in the workplace. We explored the performance of PM sensors for four different monitoring strategies (time-weighted average and high time resolution, each quantitative and semi-quantitative) for assessing occupational exposure using low-cost PM sensors in a field study in the industrial bakery sector. Measurements were collected using four types of sensor (PATS+, Isensit, Airbeam2, and Munisense) and two reference devices (respirable gravimetric samplers and an established time-resolved device) at two large-scale bakeries, spread over 11 participants and 6 measurement days. Average PM2.5 concentrations of the low-cost sensors were compared with gravimetric respirable concentrations for 8-h shift periods and 1-min PM2.5 concentrations of the low-cost sensors were compared with time-resolved PM2.5 data from the reference device (quantitative monitoring strategy). Low-cost sensors were also ranked in terms of exposure for 8-h shifts and for 15-min periods with a shift (semi-quantitative monitoring strategy). Environmental factors and methodological variables, which can affect sensor performance, were investigated. Semi-quantitative monitoring strategies only showed more accurate results compared with quantitative strategies when these were based on shift-average exposures. The main factors that influenced sensor performance were the type of placement (positioning the devices stationary versus personal) and the company or workstation where measurements were collected. Together, these findings provide an overview of common strengths and drawbacks of low-cost sensors and different ways these can be applied in the workplace. This can be used as a starting point for further investigations and the development of guidance documents and data analysis methods.
- Open Access
- 19 November 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (22) , 8602
Exploring Evaluation Variables for Low-Cost Particulate Matter Monitors to Assess Occupational Exposure
(1) Background: Small, lightweight, low-cost optical particulate matter (PM) monitors are becoming popular in the field of occupational exposure monitoring, because these devices allow for real-time static measurements to be collected at multiple locations throughout a work site as well as being used as wearables providing personal exposure estimates. Prior to deployment, devices should be evaluated to optimize and quantify measurement accuracy. However, this can turn out to be difficult, as no standardized methods are yet available and different deployments may require different evaluation procedures. To gain insight in the relevance of different variables that may affect the monitor readings, six PM monitors were selected based on current availability and evaluated in the laboratory; (2) Methods: Existing strategies that were judged appropriate for the evaluation of PM monitors were reviewed and seven evaluation variables were selected, namely the type of dust, within- and between-device variations, nature of the power supply, temperature, relative humidity, and exposure pattern (peak and constant). Each variable was tested and analyzed individually and, if found to affect the readings significantly, included in a final correction model specific to each monitor. Finally, the accuracy for each monitor after correction was calculated; (3) Results: The reference materials and exposure patterns were found to be main factors needing correction for most monitors. One PM monitor was found to be sufficiently accurate at concentrations up to 2000 µg/m3 PM2.5, with other monitors appropriate at lower concentrations. The average accuracy increased by up to three-fold compared to when the correction model did not include evaluation variables; (4) Conclusions: Laboratory evaluation and readings correction can greatly increase the accuracy of PM monitors and set boundaries for appropriate use. However, this requires identifying the relevant evaluation variables, which are heavily reliant on how the monitors are used in the workplace. This, together with the lack of current consensus on standardized procedures, shows the need for harmonized PM monitor evaluation methods for occupational exposure monitoring.
- 19 November 2020
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 17 (22) , 8602
Open AccessExploring Evaluation Variables for Low-Cost Particulate Matter Monitors to Assess Occupational Exposure
(1) Background: Small, lightweight, low-cost optical particulate matter (PM) monitors are becoming popular in the field of occupational exposure monitoring, because these devices allow for real-time static measurements to be collected at multiple locations throughout a work site as well as being used as wearables providing personal exposure estimates. Prior to deployment, devices should be evaluated to optimize and quantify measurement accuracy. However, this can turn out to be difficult, as no standardized methods are yet available and different deployments may require different evaluation procedures. To gain insight in the relevance of different variables that may affect the monitor readings, six PM monitors were selected based on current availability and evaluated in the laboratory; (2) Methods: Existing strategies that were judged appropriate for the evaluation of PM monitors were reviewed and seven evaluation variables were selected, namely the type of dust, within- and between-device variations, nature of the power supply, temperature, relative humidity, and exposure pattern (peak and constant). Each variable was tested and analyzed individually and, if found to affect the readings significantly, included in a final correction model specific to each monitor. Finally, the accuracy for each monitor after correction was calculated; (3) Results: The reference materials and exposure patterns were found to be main factors needing correction for most monitors. One PM monitor was found to be sufficiently accurate at concentrations up to 2000 µg/m3 PM2.5, with other monitors appropriate at lower concentrations. The average accuracy increased by up to three-fold compared to when the correction model did not include evaluation variables; (4) Conclusions: Laboratory evaluation and readings correction can greatly increase the accuracy of PM monitors and set boundaries for appropriate use. However, this requires identifying the relevant evaluation variables, which are heavily reliant on how the monitors are used in the workplace. This, together with the lack of current consensus on standardized procedures, shows the need for harmonized PM monitor evaluation methods for occupational exposure monitoring.