Ioannis Manousakas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ioannis Manousakas has a total of 163 co-authors. Here are the top co-authors by number of shared publications:
Chien-Chen Chang
Department of Urology, National Cheng Kung University Hospital, Tainan, Taiwan 701
3 shared publicationsShen-Min Liang
Department of Computer Application Engineering, Far East College, Hsin-Shih, Tainan County, Taiwan 744
3 shared publications- Shyh Ming Kuo
Department of Biomedical Engineering, I-Shou University, Kaohsiung City, Taiwan
2 shared publications Yong-Ren Pu
Department of Occupational Safety and Health, Chang Jung Christian University, Tainan 711
2 shared publicationsAilong Cai
National Digital Switching System Engineering & Technological Research Centre, Zhengzhou, 450002, Henan, People’s Republic of China
1 shared publication- Baiying Lei
Shenzhen University
1 shared publication
Latest Publications
- Open Access
Signal Quality Analysis of Single-Arm Electrocardiography
The number of people experiencing mental stress or emotional dysfunction has increased since the onset of the COVID-19 pandemic, as many individuals have had to adapt their daily lives. Numerous studies have demonstrated that mental health disorders can pose a risk for certain diseases, and they are also closely associated with the problem of mental workload. Now, wearable devices and mobile health applications are being utilized to monitor and assess individuals’ mental health conditions on a daily basis using heart rate variability (HRV), typically measured by the R-to-R wave interval (RRI) of an electrocardiogram (ECG). However, portable or wearable ECG devices generally require two electrodes to perform bipolar limb leads, such as the Einthoven triangle. This study aims to develop a single-arm ECG measurement method, with lead I ECG serving as the gold standard. We conducted static and dynamic experiments to analyze the morphological performance and signal-to-noise ratio (SNR) of the single-arm ECG. Three morphological features were defined, RRI, the duration of the QRS complex wave, and the amplitude of the R wave. Thirty subjects participated in this study. The results indicated that RRI exhibited the highest cross-correlation (R = 0.9942) between the single-arm ECG and lead I ECG, while the duration of the QRS complex wave showed the weakest cross-correlation (R = 0.2201). The best SNR obtained was 26.1 ± 5.9 dB during the resting experiment, whereas the worst SNR was 12.5 ± 5.1 dB during the raising and lowering of the arm along the z-axis. This single-arm ECG measurement method offers easier operation compared to traditional ECG measurement techniques, making it applicable for HRV measurement and the detection of an irregular RRI.
Open AccessSignal Quality Analysis of Single-Arm Electrocardiography
The number of people experiencing mental stress or emotional dysfunction has increased since the onset of the COVID-19 pandemic, as many individuals have had to adapt their daily lives. Numerous studies have demonstrated that mental health disorders can pose a risk for certain diseases, and they are also closely associated with the problem of mental workload. Now, wearable devices and mobile health applications are being utilized to monitor and assess individuals’ mental health conditions on a daily basis using heart rate variability (HRV), typically measured by the R-to-R wave interval (RRI) of an electrocardiogram (ECG). However, portable or wearable ECG devices generally require two electrodes to perform bipolar limb leads, such as the Einthoven triangle. This study aims to develop a single-arm ECG measurement method, with lead I ECG serving as the gold standard. We conducted static and dynamic experiments to analyze the morphological performance and signal-to-noise ratio (SNR) of the single-arm ECG. Three morphological features were defined, RRI, the duration of the QRS complex wave, and the amplitude of the R wave. Thirty subjects participated in this study. The results indicated that RRI exhibited the highest cross-correlation (R = 0.9942) between the single-arm ECG and lead I ECG, while the duration of the QRS complex wave showed the weakest cross-correlation (R = 0.2201). The best SNR obtained was 26.1 ± 5.9 dB during the resting experiment, whereas the worst SNR was 12.5 ± 5.1 dB during the raising and lowering of the arm along the z-axis. This single-arm ECG measurement method offers easier operation compared to traditional ECG measurement techniques, making it applicable for HRV measurement and the detection of an irregular RRI.
- Open Access
- 19 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0242371
Influence of quantified dry cupping on soft tissue compliance in athletes with myofascial pain syndrome
Purpose: This study aimed to develop a quantitative dry cupping system that can monitor negative pressure attenuation and soft tissue pull-up during cupping to quantify soft tissue compliance.Methods: Baseball players with myofascial pain syndrome were recruited to validate the benefits of cupping therapy. Nine of 40 baseball players on the same team were diagnosed with trapezius myofascial pain syndrome; another nine players from the same team were recruited as controls. All participants received cupping with a negative pressure of 400 mmHg for 15 minutes each time, twice a week, for 4 weeks. Subjective perception was investigated using upper extremity function questionnaires, and soft tissue compliance was quantified objectively by the system.Results: During the 15-minute cupping procedure, pressure attenuation in the normal group was significantly greater than that in the myofascial group (p= 0.017). The soft tissue compliance in the normal group was significantly higher than that in the myofascial group (p= 0.050). Moreover, a 4-week cupping intervention resulted in an obvious increase in soft tissue lift in the myofascial pain group (p= 0.027), although there was no statistical difference in the improvement of soft tissue compliance. Shoulder (p= 0.023) and upper extremity function (p= 0.008) were significantly improved in both groups, but there was no significant difference between the two groups.Conclusion: This quantitative cupping monitoring system could immediately assess tissue compliance and facilitate the improvement of soft tissues after cupping therapy. Hence, it can be used in athletes to improve their functional recovery and maintain soft tissues health during the off-season period.
- 19 November 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (11) , e0242371
Open AccessInfluence of quantified dry cupping on soft tissue compliance in athletes with myofascial pain syndrome
Purpose: This study aimed to develop a quantitative dry cupping system that can monitor negative pressure attenuation and soft tissue pull-up during cupping to quantify soft tissue compliance.Methods: Baseball players with myofascial pain syndrome were recruited to validate the benefits of cupping therapy. Nine of 40 baseball players on the same team were diagnosed with trapezius myofascial pain syndrome; another nine players from the same team were recruited as controls. All participants received cupping with a negative pressure of 400 mmHg for 15 minutes each time, twice a week, for 4 weeks. Subjective perception was investigated using upper extremity function questionnaires, and soft tissue compliance was quantified objectively by the system.Results: During the 15-minute cupping procedure, pressure attenuation in the normal group was significantly greater than that in the myofascial group (p= 0.017). The soft tissue compliance in the normal group was significantly higher than that in the myofascial group (p= 0.050). Moreover, a 4-week cupping intervention resulted in an obvious increase in soft tissue lift in the myofascial pain group (p= 0.027), although there was no statistical difference in the improvement of soft tissue compliance. Shoulder (p= 0.023) and upper extremity function (p= 0.008) were significantly improved in both groups, but there was no significant difference between the two groups.Conclusion: This quantitative cupping monitoring system could immediately assess tissue compliance and facilitate the improvement of soft tissues after cupping therapy. Hence, it can be used in athletes to improve their functional recovery and maintain soft tissues health during the off-season period.
- Open Access
- 20 August 2019
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 20 (16) , 4057
Therapeutic and Protective Effects of Liposomal Encapsulation of Astaxanthin in Mice with Alcoholic Liver Fibrosis
Astaxanthin (Asta) has been demonstrated to possess anti-inflammatory, antitumor, and free radical-clearing activities. However, the poor stability and low water solubility of Asta hamper its bioavailability. The objectives of this study were to fabricate Asta-loaded liposomes (Asta-lipo) and investigate the therapeutic effects of Asta-lipo on alcoholic liver fibrosis in mice. The mice were administered with Asta-lipo or liposomes alone prior to a 3-week dose containing 30% alcohol with or without feeding with a second dose of 30% alcohol. The prepared Asta-lipo of 225.0 ± 58.3 nm in diameter, had an encapsulation efficiency of 98%. A slow release profile of 16.2% Asta from Asta-lipo was observed after a 24-h incubation. Restorative actions against alcoholic liver fibrosis were observed after oral administration of Asta-lipo for 4 weeks. Hepatic repair, followed by a second dose of 30% alcohol, suggested that Asta-lipo exerted protective and reparative effects against liver injuries induced by repeated consumption of alcohol. The changes of serum ALT and AST values were principally in consistence with the histopathologic findings. Asta-lipo exerted rapid and direct effects against repeated alcohol-induced liver disease, whereas Asta-lipo given orally could boost recovery from liver injuries obtained due to previous long-term alcohol use. These data demonstrate that Asta-lipo has applicable protective and therapeutic potential to treat alcohol-induced liver diseases.
- 20 August 2019
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 20 (16) , 4057
Open AccessTherapeutic and Protective Effects of Liposomal Encapsulation of Astaxanthin in Mice with Alcoholic Liver Fibrosis
Astaxanthin (Asta) has been demonstrated to possess anti-inflammatory, antitumor, and free radical-clearing activities. However, the poor stability and low water solubility of Asta hamper its bioavailability. The objectives of this study were to fabricate Asta-loaded liposomes (Asta-lipo) and investigate the therapeutic effects of Asta-lipo on alcoholic liver fibrosis in mice. The mice were administered with Asta-lipo or liposomes alone prior to a 3-week dose containing 30% alcohol with or without feeding with a second dose of 30% alcohol. The prepared Asta-lipo of 225.0 ± 58.3 nm in diameter, had an encapsulation efficiency of 98%. A slow release profile of 16.2% Asta from Asta-lipo was observed after a 24-h incubation. Restorative actions against alcoholic liver fibrosis were observed after oral administration of Asta-lipo for 4 weeks. Hepatic repair, followed by a second dose of 30% alcohol, suggested that Asta-lipo exerted protective and reparative effects against liver injuries induced by repeated consumption of alcohol. The changes of serum ALT and AST values were principally in consistence with the histopathologic findings. Asta-lipo exerted rapid and direct effects against repeated alcohol-induced liver disease, whereas Asta-lipo given orally could boost recovery from liver injuries obtained due to previous long-term alcohol use. These data demonstrate that Asta-lipo has applicable protective and therapeutic potential to treat alcohol-induced liver diseases.
- Open Access
- 2 December 2016
- Published by Springer Nature in BMC Medical Imaging
- Vol. 16 (S1) , 1-12
The 5th International Conference on Biomedical Engineering and Biotechnology (ICBEB 2016)
- 2 December 2016
- Published by Springer Nature in BMC Medical Imaging
- Vol. 16 (S1) , 1-12
Open AccessThe 5th International Conference on Biomedical Engineering and Biotechnology (ICBEB 2016)
- Open Access
- 10 February 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 36
Does Low-intensity pulsed ultrasound treatment repair articular cartilage injury? A rabbit model study
Background: Low-intensity pulsed ultrasound (LIPUS) regiment has been used to treat fractures with non-union and to promote bone union in general. The effect of LIPUS on articular cartilage metabolism has been characterized. Yet, the effect of LIPUS to repair articular cartilage injury remains unclear in vivo. Methods: We designed a study to investigate the effect of LIPUS on articular cartilage repairing in a rabbit severe cartilage injury model. Eighteen rabbits were divided into three groups: Sham-operated group, operated group without-LIPUS-treatment, operated group with-LIPUS-treatment (a daily 20-minute treatment for 3 months). Full-thickness cartilage defects were surgically created on the right side distal femoral condyle without intending to penetrate into the subchondral bone, which mimicked severe chondral injury. MR images for experimental joints, morphology grading scale, and histopathological Mankin score were evaluated. Results: The preliminary results showed that the operated groups with-LIPUS-treatment and without-LIPUS-treatment had significantly higher Mankin score and morphological grading scale compared with the sham-operated group. However, there was no significant difference between the with-LIPUS-treatment and without-LIPUS-treatment groups. Cartilage defects filled with proliferative tissue were observed in the with-LIPUS-treatment group grossly and under MR images, however which presented less up-take under Alcian blue stain. Furthermore, no new deposition of type II collagen or proliferation of chondrocyte was observed over the cartilage defect after LIPUS treatment. Conclusion: LIPUS has no significant therapeutic potential in treating severe articular cartilage injury in our animal study.
- 10 February 2014
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 15 (1) , 36
Open AccessDoes Low-intensity pulsed ultrasound treatment repair articular cartilage injury? A rabbit model study
Background: Low-intensity pulsed ultrasound (LIPUS) regiment has been used to treat fractures with non-union and to promote bone union in general. The effect of LIPUS on articular cartilage metabolism has been characterized. Yet, the effect of LIPUS to repair articular cartilage injury remains unclear in vivo. Methods: We designed a study to investigate the effect of LIPUS on articular cartilage repairing in a rabbit severe cartilage injury model. Eighteen rabbits were divided into three groups: Sham-operated group, operated group without-LIPUS-treatment, operated group with-LIPUS-treatment (a daily 20-minute treatment for 3 months). Full-thickness cartilage defects were surgically created on the right side distal femoral condyle without intending to penetrate into the subchondral bone, which mimicked severe chondral injury. MR images for experimental joints, morphology grading scale, and histopathological Mankin score were evaluated. Results: The preliminary results showed that the operated groups with-LIPUS-treatment and without-LIPUS-treatment had significantly higher Mankin score and morphological grading scale compared with the sham-operated group. However, there was no significant difference between the with-LIPUS-treatment and without-LIPUS-treatment groups. Cartilage defects filled with proliferative tissue were observed in the with-LIPUS-treatment group grossly and under MR images, however which presented less up-take under Alcian blue stain. Furthermore, no new deposition of type II collagen or proliferation of chondrocyte was observed over the cartilage defect after LIPUS treatment. Conclusion: LIPUS has no significant therapeutic potential in treating severe articular cartilage injury in our animal study.
- Open Access
Design of the Dual Stone Locating System on an Extracorporeal Shock Wave Lithotriptor
Extracorporeal Shock Wave Lithotriptors are very popular for the treatment of urinary stones all over the world. They depend basically upon either X-ray fluoroscopy or ultrasound scans to detect the stones before therapy begins. To increase the effectiveness of treatment this study took advantage of both X-ray and ultrasound to develop a dual stone locating system with image processing modules. Its functions include the initial stone locating mode with stone detection by fluorescent images and the follow-up automatic stone tracking mode made by constant ultrasound scanning. The authors have integrated both apparatus and present the operating principles for both modes. The system used two in vitro experiments to justify its abilities of stone location in all procedures.
Open AccessDesign of the Dual Stone Locating System on an Extracorporeal Shock Wave Lithotriptor
Extracorporeal Shock Wave Lithotriptors are very popular for the treatment of urinary stones all over the world. They depend basically upon either X-ray fluoroscopy or ultrasound scans to detect the stones before therapy begins. To increase the effectiveness of treatment this study took advantage of both X-ray and ultrasound to develop a dual stone locating system with image processing modules. Its functions include the initial stone locating mode with stone detection by fluorescent images and the follow-up automatic stone tracking mode made by constant ultrasound scanning. The authors have integrated both apparatus and present the operating principles for both modes. The system used two in vitro experiments to justify its abilities of stone location in all procedures.
- 1 January 2009
- Published by Springer Nature
- p. 706-709
A High-Voltage Discharging System for Extracorporeal Shock-Wave Therapy
- 1 January 2009
- Published by Springer Nature
- p. 706-709
A High-Voltage Discharging System for Extracorporeal Shock-Wave Therapy
- 1 January 2009
- Published by Springer Nature
- p. 314-317
Towards a 3D Real Time Renal Calculi Tracking for Extracorporeal Shock Wave Lithotripsy
- 1 January 2009
- Published by Springer Nature
- p. 314-317
Towards a 3D Real Time Renal Calculi Tracking for Extracorporeal Shock Wave Lithotripsy
- 3 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 3489-3491
Targeting Shock Waves in human tissue for Extracorporeal Shock Wave Therapy
Extracorporeal Shock Wave Therapy is a relatively new alternative method to surgery for the treatment of many bone and muscle disorders. Currently, targeting of shock waves in the human body is done using either ultrasound or x-ray imaging. Many studies have shown controversial treatment results with conclusions that criticize ultrasound targeting. Here it is shown that targeting of the shock waves inside the body is crucial to the result of a treatment. The two different coupling methods of the shock wave generator onto the patient's body are used with gelatin phantoms to give insight into the actual treatments. As a conclusion, x-ray imaging or inline ultrasound with direct coupling should be preferred. In addition, the path of the shock waves should be vertical to the bone surfaces in order to preserve a focal region in the treated area.
- 3 February 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 4, 3489-3491
Targeting Shock Waves in human tissue for Extracorporeal Shock Wave Therapy
Extracorporeal Shock Wave Therapy is a relatively new alternative method to surgery for the treatment of many bone and muscle disorders. Currently, targeting of shock waves in the human body is done using either ultrasound or x-ray imaging. Many studies have shown controversial treatment results with conclusions that criticize ultrasound targeting. Here it is shown that targeting of the shock waves inside the body is crucial to the result of a treatment. The two different coupling methods of the shock wave generator onto the patient's body are used with gelatin phantoms to give insight into the actual treatments. As a conclusion, x-ray imaging or inline ultrasound with direct coupling should be preferred. In addition, the path of the shock waves should be vertical to the bone surfaces in order to preserve a focal region in the treated area.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 2746-2749
Ultrasound Image Analysis for Renal Stone Tracking During Extracorporeal Shock Wave Lithotripsy
Although extracorporeal shock wave lithotripsy (ESWL) is the standard procedure for treating renal stones, little work has been done on ways to minimize the side effects and on treatment optimization. A system that uses ultrasound imaging for real time renal stone monitoring is presented here and some aspects of the image analysis module are described. The improved system has proved to be more robust than the unmodified system. With such a system, the injury on healthy tissues is reduced while the treatment time is shortened
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 2746-2749
Ultrasound Image Analysis for Renal Stone Tracking During Extracorporeal Shock Wave Lithotripsy
Although extracorporeal shock wave lithotripsy (ESWL) is the standard procedure for treating renal stones, little work has been done on ways to minimize the side effects and on treatment optimization. A system that uses ultrasound imaging for real time renal stone monitoring is presented here and some aspects of the image analysis module are described. The improved system has proved to be more robust than the unmodified system. With such a system, the injury on healthy tissues is reduced while the treatment time is shortened