Ying Guo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ying Guo has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Hairong Yu
School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
4 shared publications - Lin Ye
Shanghai Enjoy Move Technology Company Ltd., Shanghai, China
4 shared publications - Steven Weidong Su
Shandong First Medical University
4 shared publications - Geoffrey Lee
CSIRO’s Data61
1 shared publication Guimei Qi
College of Computer Science and Technology, Inner Mongolia Normal University, Hohhot 010022, China
1 shared publication- Haining Fan
School of Mathematics, China University of Mining and Technology, Xuzhou, P. R. China
1 shared publication
Latest Publications
- 18 November 2024
- Published by Springer Nature
- p. 366-380
Economic Graph Lottery Ticket: A GNN Based Economic Forecasting Model
- 18 November 2024
- Published by Springer Nature
- p. 366-380
Economic Graph Lottery Ticket: A GNN Based Economic Forecasting Model
- 14 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Experimental Design for the Inclination-Based Linear Magnetometers Calibration Method
In this paper, a linear triaxial magnetometer calibration model with six observations is proposed for wearable Inertial Measurement Unit sensors. First, the information matrix of the six-parameter calibration model is derived under the proposed six-observation scheme, and its G-optimality is proven. Thereafter, a series of simulation studies were conducted to demonstrate the effectiveness and robustness of the six-observation scheme. Finally, the designed six-observation scheme is experimentally verified by the commercial Inertial Measurement Unit devices. The simulation and experimental results both demonstrate the efficiency and accuracy of the proposed optimal six-observation scheme. This scheme simplifies the calibration procedure and reduces the calculation workload, further providing guidance for the daily use of wearable sensor calibration.
- 14 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-9
Experimental Design for the Inclination-Based Linear Magnetometers Calibration Method
In this paper, a linear triaxial magnetometer calibration model with six observations is proposed for wearable Inertial Measurement Unit sensors. First, the information matrix of the six-parameter calibration model is derived under the proposed six-observation scheme, and its G-optimality is proven. Thereafter, a series of simulation studies were conducted to demonstrate the effectiveness and robustness of the six-observation scheme. Finally, the designed six-observation scheme is experimentally verified by the commercial Inertial Measurement Unit devices. The simulation and experimental results both demonstrate the efficiency and accuracy of the proposed optimal six-observation scheme. This scheme simplifies the calibration procedure and reduces the calculation workload, further providing guidance for the daily use of wearable sensor calibration.
- 18 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17579-17587
Optimal Experimental Design for In-Field Calibration of a Nine-Parameter Triaxial Magnetometers Model
This study presents an in-depth analysis of the Optimal Experimental Design for in-field calibration of tri-axial magnetometers, with a particular focus on the 9-parameter inclination-based calibration model and its implementation through 12-observation schemes. Initially, the paper examines various experimental schemes applicable to different global locations, and integrates theoretical analysis with simulation and experimental results. Then, the information matrix for the proposed 9-parameter model under the outlined 12-observation scheme is derived. Based on that the G-optimality of the proposed scheme is proved. Subsequent simulation studies rigorously evaluate the scheme’s resilience to variations in the bias angles between actual placement and ideal position, as the bias angles change from 0° to 90°, the relative efficiency decreases from 1 to 3.7586 × 10 -33 . Finally, the practical application situation of the 9-parameter calibration model and 12-observation scheme is experimentally verified by using commercial Inertial Measurement Unit devices in diverse locations. This research not only proposes a suite of numerical solutions for ideal conditions but also offers a pragmatic guide for assessing actual device placement in field applications.
- 18 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 17579-17587
Optimal Experimental Design for In-Field Calibration of a Nine-Parameter Triaxial Magnetometers Model
This study presents an in-depth analysis of the Optimal Experimental Design for in-field calibration of tri-axial magnetometers, with a particular focus on the 9-parameter inclination-based calibration model and its implementation through 12-observation schemes. Initially, the paper examines various experimental schemes applicable to different global locations, and integrates theoretical analysis with simulation and experimental results. Then, the information matrix for the proposed 9-parameter model under the outlined 12-observation scheme is derived. Based on that the G-optimality of the proposed scheme is proved. Subsequent simulation studies rigorously evaluate the scheme’s resilience to variations in the bias angles between actual placement and ideal position, as the bias angles change from 0° to 90°, the relative efficiency decreases from 1 to 3.7586 × 10 -33 . Finally, the practical application situation of the 9-parameter calibration model and 12-observation scheme is experimentally verified by using commercial Inertial Measurement Unit devices in diverse locations. This research not only proposes a suite of numerical solutions for ideal conditions but also offers a pragmatic guide for assessing actual device placement in field applications.
- Open Access
- 19 July 2023
- Published by Cambridge University Press (CUP) in Publications of the Astronomical Society of Australia
- Vol. 40, 1-29
Measuring photometric redshifts for high-redshift radio source surveys
With the advent of deep, all-sky radio surveys, the need for ancillary data to make the most of the new, high-quality radio data from surveys like the Evolutionary Map of the Universe (EMU), GaLactic and Extragalactic All-sky MurchisonWidefield Array survey eXtended, Very Large Array Sky Survey and LOFAR Two-metre Sky Survey is growing rapidly. Radio surveys produce significant numbers of Active Galactic Nuclei (AGNs), and have a significantly higher average redshift when compared with optical and infrared all-sky surveys. Thus, traditional methods of estimating redshift are challenged, with spectroscopic surveys not reaching the redshift depth of radio surveys, and AGNs making it difficult for template fitting methods to accurately model the source. Machine Learning (ML) methods have been used, but efforts have typically been directed towards optically selected samples, or samples at significantly lower redshift than expected from upcoming radio surveys. This work compiles and homogenises a radio-selected dataset from both the northern hemisphere (making use of Sloan Digital Sky Survey optical photometry), and southern hemisphere (making use of Dark Energy Survey optical photometry). We then test commonly used ML algorithms such as k-Nearest Neighbours (kNN), Random Forest, ANNz and GPz on this monolithic radio-selected sample. We show that kNN has the lowest percentage of catastrophic outliers, providing the best match for the majority of science cases in the EMU survey. We note that the wider redshift range of the combined dataset used allows for estimation of sources up to z = 3 before random scatter begins to dominate. When binning the data into redshift bins and treating the problem as a classification problem, we are able to correctly identify ≈76% of the highest redshift sources — sources at redshift z > 2.51 — as being in either the highest bin (z > 2.51), or second highest (z = 2.25).
- 19 July 2023
- Published by Cambridge University Press (CUP) in Publications of the Astronomical Society of Australia
- Vol. 40, 1-29
Open AccessMeasuring photometric redshifts for high-redshift radio source surveys
With the advent of deep, all-sky radio surveys, the need for ancillary data to make the most of the new, high-quality radio data from surveys like the Evolutionary Map of the Universe (EMU), GaLactic and Extragalactic All-sky MurchisonWidefield Array survey eXtended, Very Large Array Sky Survey and LOFAR Two-metre Sky Survey is growing rapidly. Radio surveys produce significant numbers of Active Galactic Nuclei (AGNs), and have a significantly higher average redshift when compared with optical and infrared all-sky surveys. Thus, traditional methods of estimating redshift are challenged, with spectroscopic surveys not reaching the redshift depth of radio surveys, and AGNs making it difficult for template fitting methods to accurately model the source. Machine Learning (ML) methods have been used, but efforts have typically been directed towards optically selected samples, or samples at significantly lower redshift than expected from upcoming radio surveys. This work compiles and homogenises a radio-selected dataset from both the northern hemisphere (making use of Sloan Digital Sky Survey optical photometry), and southern hemisphere (making use of Dark Energy Survey optical photometry). We then test commonly used ML algorithms such as k-Nearest Neighbours (kNN), Random Forest, ANNz and GPz on this monolithic radio-selected sample. We show that kNN has the lowest percentage of catastrophic outliers, providing the best match for the majority of science cases in the EMU survey. We note that the wider redshift range of the combined dataset used allows for estimation of sources up to z = 3 before random scatter begins to dominate. When binning the data into redshift bins and treating the problem as a classification problem, we are able to correctly identify ≈76% of the highest redshift sources — sources at redshift z > 2.51 — as being in either the highest bin (z > 2.51), or second highest (z = 2.25).
- 5 July 2023
- Published by Elsevier in Computers and Electronics in Agriculture
- Vol. 211, 108027
Sheep face image dataset and DT-YOLOv5s for sheep breed recognition
- 5 July 2023
- Published by Elsevier in Computers and Electronics in Agriculture
- Vol. 211, 108027
Sheep face image dataset and DT-YOLOv5s for sheep breed recognition
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Statistical Analysis of In-Field Magnetometer Calibration for Two Representative Methods
In this article, we propose a procedure for the investigation of the feasibility and effectiveness of recently developed in-field magnetometer calibration methods. Extensive numerical analyses under different noise levels are conducted to identify the proper measurement conditions of each method. The variance analysis is also presented to study the observability of model parameters based on the information matrix under different inclination angles. In accordance with the analysis, several important conclusions are drawn including the condition to ensure the validity of the parameter estimation and the approach to improve the performance of the calibration results. Numerical simulation and experimental validation support our analytical findings. Accordingly, this study provides an in-depth exploration of the limitations of typical in-field magnetometer calibration methods.
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-8
Statistical Analysis of In-Field Magnetometer Calibration for Two Representative Methods
In this article, we propose a procedure for the investigation of the feasibility and effectiveness of recently developed in-field magnetometer calibration methods. Extensive numerical analyses under different noise levels are conducted to identify the proper measurement conditions of each method. The variance analysis is also presented to study the observability of model parameters based on the information matrix under different inclination angles. In accordance with the analysis, several important conclusions are drawn including the condition to ensure the validity of the parameter estimation and the approach to improve the performance of the calibration results. Numerical simulation and experimental validation support our analytical findings. Accordingly, this study provides an in-depth exploration of the limitations of typical in-field magnetometer calibration methods.
- 20 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
An Effective In-Field Calibration Method for Triaxial Magnetometers Based on Local Magnetic Inclination
This paper presents an innovative in-field calibration method for portable triaxial magnetometers (TMs). For in-field calibration of portable sensors, it is difficult to provide accurately measured inputs to each sensitivity axis due to the unavailability of high precision turntables. Because of this limitation, most existing in-field calibration methods often require nonlinear optimization to identify model parameters. According to the fact that the angle between the local gravity and magnetic field is invariant, a new in-field calibration approach called Inclination Based Calibration (I-Calibration) was proposed. The I-Calibration could reliably estimate model parameters of the magnetometers by simply using a linear Least Square estimator. A 12-observation Icosahedron experimental scheme was performed for a micro Inertial Measurement Unit, which contains both triaxial accelerometers (TAs) and triaxial magnetometers. The effectiveness, as well as the robustness with the misalignments of the TAs and TMs, of the proposed calibration method, was first verified by using numerical simulations. Thereafter, in real data experiments, the proposed method was compared with an existing calibration approach, named Magnitude Based Calibration (M-Calibration), which is based on the fact that the magnitude of the local magnetic field is invariant. The calibrated results together with the comparison between the two methods demonstrated the effectiveness of the proposed method.
- 20 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-9
An Effective In-Field Calibration Method for Triaxial Magnetometers Based on Local Magnetic Inclination
This paper presents an innovative in-field calibration method for portable triaxial magnetometers (TMs). For in-field calibration of portable sensors, it is difficult to provide accurately measured inputs to each sensitivity axis due to the unavailability of high precision turntables. Because of this limitation, most existing in-field calibration methods often require nonlinear optimization to identify model parameters. According to the fact that the angle between the local gravity and magnetic field is invariant, a new in-field calibration approach called Inclination Based Calibration (I-Calibration) was proposed. The I-Calibration could reliably estimate model parameters of the magnetometers by simply using a linear Least Square estimator. A 12-observation Icosahedron experimental scheme was performed for a micro Inertial Measurement Unit, which contains both triaxial accelerometers (TAs) and triaxial magnetometers. The effectiveness, as well as the robustness with the misalignments of the TAs and TMs, of the proposed calibration method, was first verified by using numerical simulations. Thereafter, in real data experiments, the proposed method was compared with an existing calibration approach, named Magnitude Based Calibration (M-Calibration), which is based on the fact that the magnitude of the local magnetic field is invariant. The calibrated results together with the comparison between the two methods demonstrated the effectiveness of the proposed method.
- 1 January 2019
- Published by Inderscience Publishers in International Journal of Intelligent Systems Technologies and Applications
- Vol. 18 (1/2) , 204
Support vector machine based fault detection and diagnosis for HVAC systems
International publishers of academic, scientific and professional journals since 1979.
- 1 January 2019
- Published by Inderscience Publishers in International Journal of Intelligent Systems Technologies and Applications
- Vol. 18 (1/2) , 204
Support vector machine based fault detection and diagnosis for HVAC systems
International publishers of academic, scientific and professional journals since 1979.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 8 (21619646) , 1-5
Blind Parameter Estimation of Frequency Hopping Signals Based on Matching Pursuit
A new method is presented for blind parameter estimation of frequency hopping signals. According to the inner structure of frequency hopping signals, the three-parameter frequency-time atom is obtained from the unit windowed sine function by successive applications of scaling, time-shift and frequency-shift operators. On the base of these, a new matching pursuit based parameter estimation method of frequency hopping signal is developed. Using this method, the parameter of frequency hopping signals i.e. as hop duration, hop timing and hopping frequencies can be estimated without any priori knowledge. Simulation results demonstrate that the method is effective and efficient.
- 1 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 8 (21619646) , 1-5
Blind Parameter Estimation of Frequency Hopping Signals Based on Matching Pursuit
A new method is presented for blind parameter estimation of frequency hopping signals. According to the inner structure of frequency hopping signals, the three-parameter frequency-time atom is obtained from the unit windowed sine function by successive applications of scaling, time-shift and frequency-shift operators. On the base of these, a new matching pursuit based parameter estimation method of frequency hopping signal is developed. Using this method, the parameter of frequency hopping signals i.e. as hop duration, hop timing and hopping frequencies can be estimated without any priori knowledge. Simulation results demonstrate that the method is effective and efficient.