Kazutaka Kuroda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kazutaka Kuroda has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Kenji Shimada
Department of Neurosurgery, Tokushima University, Tokushima, Tokushima, Japan
2 shared publications - Shu Sogabe
Department of Neurosurgery, Tokushima University, Tokushima, Japan
2 shared publications - Yasuhisa Kanematsu
Department of Neurosurgery, Tokushima University, Tokushima, Tokushima, Japan
2 shared publications - Yasushi Takagi
Department of Neurosurgery, Tokushima University Graduate School of Biomedical Science, Tokushima, Japan
2 shared publications - Yuishin Izumi
Department of Neurology, Tokushima University, Tokushima, Japan
2 shared publications - Yuki Yamamoto
Department of Neurology Tokushima University Graduate School of Biomedical Sciences Tokushima Japan
2 shared publications
Latest Publications
- Open Access
- 4 August 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 274
Stent retrieval for free-floating thrombus attached to carotid artery stenosis: A report of two cases
We report two cases who underwent mechanical thrombectomy using a stent retriever in advance of urgent carotid artery stenting (CAS) for carotid artery stenosis with free-floating thrombus (FFT). Two patients showing symptomatic carotid artery stenosis with FFT underwent urgent endovascular surgery due to progressive neurological symptoms. The first case showed an FFT with 70% internal carotid artery (ICA) stenosis. After the completion of the common and external carotid artery balloon and distal ICA filter protection, we deployed a 6-mm-diameter stent retriever in the distal part of the stenosis. The white thrombus was retrieved; the angiographic shadow of the FFT disappeared; and CAS was performed. In the second case, due to a 90% severe stenosis lesion with FFT, balloon angioplasty was performed on the lesion using the push wire of the stent retriever. After angioplasty, the stent retriever was smoothly retrieved, and CAS was performed. Postoperative magnetic resonance imaging showed an increase in cerebral embolism in the first case; however, the patient's neurological symptoms improved. The second case showed in-stent plaque protrusion and required two additional stent placements; the patient showed no worsening of his neurological symptoms. In cases of carotid artery stenosis with FFT, it is technically possible to retrieve a thrombus with a stent retriever. Although thrombus removal may help reduce the risk of ischemic complications in a series of urgent CAS procedures, there are concerns such as mechanical irritation to the carotid artery plaque, and its indications and alternative treatments should be carefully considered.
- 4 August 2023
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 14, 274
Open AccessStent retrieval for free-floating thrombus attached to carotid artery stenosis: A report of two cases
We report two cases who underwent mechanical thrombectomy using a stent retriever in advance of urgent carotid artery stenting (CAS) for carotid artery stenosis with free-floating thrombus (FFT). Two patients showing symptomatic carotid artery stenosis with FFT underwent urgent endovascular surgery due to progressive neurological symptoms. The first case showed an FFT with 70% internal carotid artery (ICA) stenosis. After the completion of the common and external carotid artery balloon and distal ICA filter protection, we deployed a 6-mm-diameter stent retriever in the distal part of the stenosis. The white thrombus was retrieved; the angiographic shadow of the FFT disappeared; and CAS was performed. In the second case, due to a 90% severe stenosis lesion with FFT, balloon angioplasty was performed on the lesion using the push wire of the stent retriever. After angioplasty, the stent retriever was smoothly retrieved, and CAS was performed. Postoperative magnetic resonance imaging showed an increase in cerebral embolism in the first case; however, the patient's neurological symptoms improved. The second case showed in-stent plaque protrusion and required two additional stent placements; the patient showed no worsening of his neurological symptoms. In cases of carotid artery stenosis with FFT, it is technically possible to retrieve a thrombus with a stent retriever. Although thrombus removal may help reduce the risk of ischemic complications in a series of urgent CAS procedures, there are concerns such as mechanical irritation to the carotid artery plaque, and its indications and alternative treatments should be carefully considered.
- 1 December 2020
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 199, 106316
Factors associated with DWI-ASPECTS score in patients with acute ischemic stroke due to cerebral large vessel occlusion
- 1 December 2020
- Published by Elsevier in Clinical Neurology and Neurosurgery
- Vol. 199, 106316
Factors associated with DWI-ASPECTS score in patients with acute ischemic stroke due to cerebral large vessel occlusion