Caroline Hain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Caroline Hain has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Krzysztof Wieczerzak
Laboratory for Mechanics of Materials and Nanostructures, Empa─Swiss Federal Laboratories for Materials Science and Technology, Feuerwerkerstrasse 39, CH-3602, CH-8093 Zürich, Switzerland
2 shared publications A. Sharma
1 shared publicationAlberto Ortona
1 shared publication- Aldo Roberto Boccaccini
Institute of Biomaterials University of Erlangen‐Nuremberg Erlangen Germany
1 shared publication Alina Grünewald
Department of Materials Science and Engineering, Institute of Biomaterials University of Erlangen‐Nuremberg Erlangen Germany
1 shared publicationDarren Parkison
1 shared publication
Latest Publications
- Open Access
- 19 May 2024
- Published by Springer Nature in Journal of Materials Science
- Vol. 59 (20) , 9107-9125
Microstructure and mechanical properties of Ti-Nb alloys: comparing conventional powder metallurgy, mechanical alloying, and high power impulse magnetron sputtering processes for supporting materials screening
At the interface of thin film development and powder metallurgy technologies, this study aims to characterise the mechanical properties, lattice constants and phase formation of Ti-Nb alloys (8–30 at.%) produced by different manufacturing methods, including conventional powder metallurgy (PM), mechanical alloying (MA) and high power impulse magnetron sputtering (HiPIMS). A central aspect of this research was to investigate the different energy states achievable by each synthesis method. The findings revealed that as the Nb content increased, both the hardness and Young’s modulus of the PM samples decreased (from 4 to 1.5 and 125 to 85 GPa, respectively). For the MA alloys, the hardness and Young’s modulus varied between 3.2 and 3.9 and 100 to 116 GPa, respectively, with the lowest values recorded for 20% Nb (3.2 and 96 GPa). The Young’s modulus of the HiPIMS thin film samples did not follow a specific trend and varied between 110 and 138 GPa. However, an increase in hardness (from 3.6 to 4.8 GPa) coincided with an increase in the β2 phase contribution for films with the same chemical composition (23 at.% of Nb). This study highlights the potential of using HiPIMS gradient films for high throughput analysis for PM and MA techniques. This discovery is important as it provides a way to reduce the development time for complex alloy systems in biomaterials as well as other areas of materials engineering. Graphical abstract
- 19 May 2024
- Published by Springer Nature in Journal of Materials Science
- Vol. 59 (20) , 9107-9125
Open AccessMicrostructure and mechanical properties of Ti-Nb alloys: comparing conventional powder metallurgy, mechanical alloying, and high power impulse magnetron sputtering processes for supporting materials screening
At the interface of thin film development and powder metallurgy technologies, this study aims to characterise the mechanical properties, lattice constants and phase formation of Ti-Nb alloys (8–30 at.%) produced by different manufacturing methods, including conventional powder metallurgy (PM), mechanical alloying (MA) and high power impulse magnetron sputtering (HiPIMS). A central aspect of this research was to investigate the different energy states achievable by each synthesis method. The findings revealed that as the Nb content increased, both the hardness and Young’s modulus of the PM samples decreased (from 4 to 1.5 and 125 to 85 GPa, respectively). For the MA alloys, the hardness and Young’s modulus varied between 3.2 and 3.9 and 100 to 116 GPa, respectively, with the lowest values recorded for 20% Nb (3.2 and 96 GPa). The Young’s modulus of the HiPIMS thin film samples did not follow a specific trend and varied between 110 and 138 GPa. However, an increase in hardness (from 3.6 to 4.8 GPa) coincided with an increase in the β2 phase contribution for films with the same chemical composition (23 at.% of Nb). This study highlights the potential of using HiPIMS gradient films for high throughput analysis for PM and MA techniques. This discovery is important as it provides a way to reduce the development time for complex alloy systems in biomaterials as well as other areas of materials engineering. Graphical abstract
- Open Access
- 10 May 2023
- Published by Elsevier in Materials & Design
- Vol. 230
Crystalline or amorphous? A critical evaluation of phenomenological phase selection rules
- 10 May 2023
- Published by Elsevier in Materials & Design
- Vol. 230
Open AccessCrystalline or amorphous? A critical evaluation of phenomenological phase selection rules
- Open Access
- 26 August 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 111 (2) , 241-260
In vitro cytocompatibility and antibacterial studies on biodegradable Zn alloys supplemented by a critical assessment of direct contact cytotoxicity assay
In vitro cytotoxicity assessment is indispensable in developing new biodegradable implant materials. Zn, which demonstrates an ideal corrosion rate between Mg‐ and Fe‐based alloys, has been reported to have excellent in vivo biocompatibility. Therefore, modifications aimed at improving Zn's mechanical properties should not degrade its biological response. As sufficient strength, ductility and corrosion behavior required of load‐bearing implants has been obtained in plastically deformed Zn‐3Ag‐0.5Mg, the effect of simultaneous Ag and Mg additions on in vitro cytocompatibility and antibacterial properties was studied, in relation to Zn and Zn‐3Ag. Direct cell culture on samples and indirect extract‐based tests showed almost no significant differences between the tested Zn‐based materials. The diluted extracts of Zn, Zn‐3Ag, and Zn‐3Ag‐0.5Mg showed no cytotoxicity toward MG‐63 cells at a concentration of ≤12.5%. The cytotoxic effect was observed only at high Zn2+ ion concentrations and when in direct contact with metallic samples. The highest LD50 (lethal dose killing 50% of cells) of 13.4 mg/L of Zn2+ ions were determined for the Zn‐3Ag‐0.5Mg. Similar antibacterial activity against Escherichia coli and Staphylococcus aureus was observed for Zn and Zn alloys, so the effect is attributed mainly to the released Zn2+ ions exhibiting bactericidal properties. Most importantly, our experiments indicated the limitations of water‐soluble tetrazolium salt‐based cytotoxicity assays for direct tests on Zn‐based materials. The discrepancies between the WST‐8 assay and SEM observations are attributed to the interference of Zn2+ ions with tetrazolium salt, therefore favoring its transformation into formazan, giving false cell viability quantitative results.
- 26 August 2022
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 111 (2) , 241-260
Open AccessIn vitro cytocompatibility and antibacterial studies on biodegradable Zn alloys supplemented by a critical assessment of direct contact cytotoxicity assay
In vitro cytotoxicity assessment is indispensable in developing new biodegradable implant materials. Zn, which demonstrates an ideal corrosion rate between Mg‐ and Fe‐based alloys, has been reported to have excellent in vivo biocompatibility. Therefore, modifications aimed at improving Zn's mechanical properties should not degrade its biological response. As sufficient strength, ductility and corrosion behavior required of load‐bearing implants has been obtained in plastically deformed Zn‐3Ag‐0.5Mg, the effect of simultaneous Ag and Mg additions on in vitro cytocompatibility and antibacterial properties was studied, in relation to Zn and Zn‐3Ag. Direct cell culture on samples and indirect extract‐based tests showed almost no significant differences between the tested Zn‐based materials. The diluted extracts of Zn, Zn‐3Ag, and Zn‐3Ag‐0.5Mg showed no cytotoxicity toward MG‐63 cells at a concentration of ≤12.5%. The cytotoxic effect was observed only at high Zn2+ ion concentrations and when in direct contact with metallic samples. The highest LD50 (lethal dose killing 50% of cells) of 13.4 mg/L of Zn2+ ions were determined for the Zn‐3Ag‐0.5Mg. Similar antibacterial activity against Escherichia coli and Staphylococcus aureus was observed for Zn and Zn alloys, so the effect is attributed mainly to the released Zn2+ ions exhibiting bactericidal properties. Most importantly, our experiments indicated the limitations of water‐soluble tetrazolium salt‐based cytotoxicity assays for direct tests on Zn‐based materials. The discrepancies between the WST‐8 assay and SEM observations are attributed to the interference of Zn2+ ions with tetrazolium salt, therefore favoring its transformation into formazan, giving false cell viability quantitative results.
- Open Access
- 5 January 2022
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 42 (5) , 1984-1994
Liquid metal infiltration of silicon based alloys into porous carbonaceous materials. Part II: Experimental verification of modelling approaches by infiltration of Si-Zr alloy into idealized microchannels
- 5 January 2022
- Published by Elsevier in Journal of the European Ceramic Society
- Vol. 42 (5) , 1984-1994
Open AccessLiquid metal infiltration of silicon based alloys into porous carbonaceous materials. Part II: Experimental verification of modelling approaches by infiltration of Si-Zr alloy into idealized microchannels
- 1 February 2021
- Published by Elsevier in Composites Part B: Engineering
- Vol. 206
A novel fiber-fretting test for tribological characterization of the fiber/matrix interface
- 1 February 2021
- Published by Elsevier in Composites Part B: Engineering
- Vol. 206
A novel fiber-fretting test for tribological characterization of the fiber/matrix interface