Wei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wei Zhang has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
- Jiantao Li
Senior Department of Orthopedics, The Fourth Medical Center of Chinese PLA General Hospital, Beijing, China
8 shared publications Meng Li
Senior Department of Orthopedics, The Fourth Medical Center of PLA general hospital, Beijing, China
8 shared publications- Peifu Tang
Senior Department of Orthopedics The Fourth Medical Center of Chinese PLA General Hospital Beijing China
7 shared publications Xiaomeng Ren
Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, Beijing, 100089, China
7 shared publications- Lihai Zhang
China Department of Orthopedics, Chinese PLA General Hospital, Beijing 100141, China
6 shared publications - Hua Chen
Senior Department of Orthopedics, The Fourth Medical Center of PLA general hospital, Beijing, China
4 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (9) , 095018
Finite element mechanical analysis of rigid internal fixation selection for distal femur fractures
Finite element mechanical analysis of rigid internal fixation selection for distal femur fractures, Li, Meng, Zhang, Zicheng, Chen, Ming, Li, Jiantao, Zhang, Wei
- 1 September 2026
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 147 (9) , 095018
Open AccessFinite element mechanical analysis of rigid internal fixation selection for distal femur fractures
Finite element mechanical analysis of rigid internal fixation selection for distal femur fractures, Li, Meng, Zhang, Zicheng, Chen, Ming, Li, Jiantao, Zhang, Wei
- Open Access
- 23 June 2026
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 15 (1) , e88180
Navigation System–Assisted vs Freehand Cannulated Screw Fixation for Femoral Neck Fractures: Protocol for a Multicenter Randomized Controlled Trial
Background: The incidence of femoral neck fractures (FNFs) is increasing, primarily due to an aging population and an increased incidence of high-energy trauma. Although fixation with three cannulated screws (TCS) is the most commonly used surgical technique, it has limitations, including suboptimal operative accuracy and dependence on repeated intraoperative fluoroscopy. In response, advanced navigation systems have been developed to improve surgical precision and outcomes. Objective: This multicenter, prospective, randomized controlled superiority trial will compare surgical outcomes between an intelligent navigation system and the conventional freehand technique for FNF, as well as long-term fracture healing and complication rates. Methods: This multicenter, prospective, randomized controlled superiority trial will compare navigation system–assisted TCS fixation with conventional freehand TCS fixation in patients with FNF from June 2024 to October 2026. Eligible participants are adults aged ≥18 years diagnosed with FNF who are indicated for internal fixation. The primary outcome is the frequency of intraoperative fluoroscopy. Secondary outcomes include the neck-shaft angle, guide wire placement quality, operative time, intraoperative blood loss, fracture healing status, the Harris Hip Score, the 36-Item Short Form Health Survey, and the Zarit Caregiver Burden Score. The sample size calculation indicated that 150 (50%) participants per group (N=300) would be needed to detect a superiority margin of 15.4 fluoroscopy images with 80% power and a 1-sided α of .025, accounting for a 15% dropout rate. All patients will undergo 12 months of follow-up. Data analysis will compare groups using 1-sided t tests and Mann-Whitney U tests, supplemented by linear mixed-effects models with study site as a random effect. Results: The study was funded in May 2024 and received initial ethics approval from the institutional review board. Patient enrollment commenced in June 2024 and is projected to be completed by October 2026, with a target sample size of 300 participants. The final 12-month follow-up is expected to be completed by October 2027. As of manuscript submission, recruitment is ongoing, and no data analysis has been performed. Conclusions: Successful completion of this study may introduce a new strategy for the management of FNF and help establish a standardized protocol for the use of navigation systems, potentially enhancing clinical outcomes and reducing complication rates. Trial Registration: ClinicalTrials.gov NCT06713018; https://clinicaltrials.gov/study/NCT06713018 International Registered Report Identifier (IRRID): DERR1-10.2196/88180
- 23 June 2026
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 15 (1) , e88180
Open AccessNavigation System–Assisted vs Freehand Cannulated Screw Fixation for Femoral Neck Fractures: Protocol for a Multicenter Randomized Controlled Trial
Background: The incidence of femoral neck fractures (FNFs) is increasing, primarily due to an aging population and an increased incidence of high-energy trauma. Although fixation with three cannulated screws (TCS) is the most commonly used surgical technique, it has limitations, including suboptimal operative accuracy and dependence on repeated intraoperative fluoroscopy. In response, advanced navigation systems have been developed to improve surgical precision and outcomes. Objective: This multicenter, prospective, randomized controlled superiority trial will compare surgical outcomes between an intelligent navigation system and the conventional freehand technique for FNF, as well as long-term fracture healing and complication rates. Methods: This multicenter, prospective, randomized controlled superiority trial will compare navigation system–assisted TCS fixation with conventional freehand TCS fixation in patients with FNF from June 2024 to October 2026. Eligible participants are adults aged ≥18 years diagnosed with FNF who are indicated for internal fixation. The primary outcome is the frequency of intraoperative fluoroscopy. Secondary outcomes include the neck-shaft angle, guide wire placement quality, operative time, intraoperative blood loss, fracture healing status, the Harris Hip Score, the 36-Item Short Form Health Survey, and the Zarit Caregiver Burden Score. The sample size calculation indicated that 150 (50%) participants per group (N=300) would be needed to detect a superiority margin of 15.4 fluoroscopy images with 80% power and a 1-sided α of .025, accounting for a 15% dropout rate. All patients will undergo 12 months of follow-up. Data analysis will compare groups using 1-sided t tests and Mann-Whitney U tests, supplemented by linear mixed-effects models with study site as a random effect. Results: The study was funded in May 2024 and received initial ethics approval from the institutional review board. Patient enrollment commenced in June 2024 and is projected to be completed by October 2026, with a target sample size of 300 participants. The final 12-month follow-up is expected to be completed by October 2027. As of manuscript submission, recruitment is ongoing, and no data analysis has been performed. Conclusions: Successful completion of this study may introduce a new strategy for the management of FNF and help establish a standardized protocol for the use of navigation systems, potentially enhancing clinical outcomes and reducing complication rates. Trial Registration: ClinicalTrials.gov NCT06713018; https://clinicaltrials.gov/study/NCT06713018 International Registered Report Identifier (IRRID): DERR1-10.2196/88180
- Open Access
- 23 April 2026
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 12 (2) , 026050046
Hollow spherical mineralized scaffold integrated with a bone marrow mesenchymal stem cell-laden three-dimensional delivery system for regeneration of critical-sized bone defects
Treating critical-sized bone defects is a significant clinical challenge. Three-dimensional (3D) printing combined with bone tissue engineering (BTE) has emerged as a promising strategy for bone regeneration; however, key limitations persist, including a mismatch between scaffold degradation and osteogenesis, as well as insufficient bioactivity. In this study, we aimed to fabricate a hollow spherical mineralized biphasic calcium phosphate scaffold by 3D printing (photopolymerization via digital light processing) and incorporated within its cavity a 3D delivery system composed of methacryloyl-modified gelatin hydrogel loaded with bone marrow mesenchymal stem cells (BMSCs). The composite scaffold was systematically evaluated using material characterization, in vitro cytocompatibility analysis, and in vivo rabbit bone defect models. Our findings demonstrated that the scaffold exhibited favorable mechanical properties, biocompatibility, and enhanced osteogenic differentiation, migration, and pro-osteogenic gene expression in BMSCs. Notably, the scaffold effectively repaired critical-sized bone defects in rabbit models within 12 weeks. This novel BTE composite scaffold provides a groundbreaking design philosophy and an innovative therapeutic strategy for complex bone defect repair.
- 23 April 2026
- Published by AccScience Publishing in International Journal of Bioprinting
- Vol. 12 (2) , 026050046
Open AccessHollow spherical mineralized scaffold integrated with a bone marrow mesenchymal stem cell-laden three-dimensional delivery system for regeneration of critical-sized bone defects
Treating critical-sized bone defects is a significant clinical challenge. Three-dimensional (3D) printing combined with bone tissue engineering (BTE) has emerged as a promising strategy for bone regeneration; however, key limitations persist, including a mismatch between scaffold degradation and osteogenesis, as well as insufficient bioactivity. In this study, we aimed to fabricate a hollow spherical mineralized biphasic calcium phosphate scaffold by 3D printing (photopolymerization via digital light processing) and incorporated within its cavity a 3D delivery system composed of methacryloyl-modified gelatin hydrogel loaded with bone marrow mesenchymal stem cells (BMSCs). The composite scaffold was systematically evaluated using material characterization, in vitro cytocompatibility analysis, and in vivo rabbit bone defect models. Our findings demonstrated that the scaffold exhibited favorable mechanical properties, biocompatibility, and enhanced osteogenic differentiation, migration, and pro-osteogenic gene expression in BMSCs. Notably, the scaffold effectively repaired critical-sized bone defects in rabbit models within 12 weeks. This novel BTE composite scaffold provides a groundbreaking design philosophy and an innovative therapeutic strategy for complex bone defect repair.
- Open Access
- 15 December 2025
- Published by Elsevier in Chinese Journal of Traumatology
- Vol. 29 (4) , 291-298
Comparative study on the efficacy of structural support fixation vs. conventional fixation for depressed tibial plateau fractures
- 15 December 2025
- Published by Elsevier in Chinese Journal of Traumatology
- Vol. 29 (4) , 291-298
Open AccessComparative study on the efficacy of structural support fixation vs. conventional fixation for depressed tibial plateau fractures
- Open Access
- 20 November 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Navigation System–Assisted vs Freehand Cannulated Screw Fixation for Femoral Neck Fractures: Protocol for a Multicenter Randomized Controlled Trial (Preprint)
BACKGROUND The incidence of femoral neck fractures (FNFs) is increasing, primarily due to an aging population and an increased incidence of high-energy trauma. Although fixation with three cannulated screws (TCS) is the most commonly used surgical technique, it has limitations, including suboptimal operative accuracy and dependence on repeated intraoperative fluoroscopy. In response, advanced navigation systems have been developed to improve surgical precision and outcomes. OBJECTIVE This multicenter, prospective, randomized controlled superiority trial will compare surgical outcomes between an intelligent navigation system and the conventional freehand technique for FNF, as well as long-term fracture healing and complication rates. METHODS This multicenter, prospective, randomized controlled superiority trial will compare navigation system–assisted TCS fixation with conventional freehand TCS fixation in patients with FNF from June 2024 to October 2026. Eligible participants are adults aged ≥18 years diagnosed with FNF who are indicated for internal fixation. The primary outcome is the frequency of intraoperative fluoroscopy. Secondary outcomes include the neck-shaft angle, guide wire placement quality, operative time, intraoperative blood loss, fracture healing status, the Harris Hip Score, the 36-Item Short Form Health Survey, and the Zarit Caregiver Burden Score. The sample size calculation indicated that 150 (50%) participants per group (N=300) would be needed to detect a superiority margin of 15.4 fluoroscopy images with 80% power and a 1-sided α of .025, accounting for a 15% dropout rate. All patients will undergo 12 months of follow-up. Data analysis will compare groups using 1-sided t tests and Mann-Whitney U tests, supplemented by linear mixed-effects models with study site as a random effect. RESULTS The study was funded in May 2024 and received initial ethics approval from the institutional review board. Patient enrollment commenced in June 2024 and is projected to be completed by October 2026, with a target sample size of 300 participants. The final 12-month follow-up is expected to be completed by October 2027. As of manuscript submission, recruitment is ongoing, and no data analysis has been performed. CONCLUSIONS Successful completion of this study may introduce a new strategy for the management of FNF and help establish a standardized protocol for the use of navigation systems, potentially enhancing clinical outcomes and reducing complication rates. CLINICALTRIAL ClinicalTrials.gov NCT06713018; https://clinicaltrials.gov/study/NCT06713018 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/88180
- 20 November 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessNavigation System–Assisted vs Freehand Cannulated Screw Fixation for Femoral Neck Fractures: Protocol for a Multicenter Randomized Controlled Trial (Preprint)
BACKGROUND The incidence of femoral neck fractures (FNFs) is increasing, primarily due to an aging population and an increased incidence of high-energy trauma. Although fixation with three cannulated screws (TCS) is the most commonly used surgical technique, it has limitations, including suboptimal operative accuracy and dependence on repeated intraoperative fluoroscopy. In response, advanced navigation systems have been developed to improve surgical precision and outcomes. OBJECTIVE This multicenter, prospective, randomized controlled superiority trial will compare surgical outcomes between an intelligent navigation system and the conventional freehand technique for FNF, as well as long-term fracture healing and complication rates. METHODS This multicenter, prospective, randomized controlled superiority trial will compare navigation system–assisted TCS fixation with conventional freehand TCS fixation in patients with FNF from June 2024 to October 2026. Eligible participants are adults aged ≥18 years diagnosed with FNF who are indicated for internal fixation. The primary outcome is the frequency of intraoperative fluoroscopy. Secondary outcomes include the neck-shaft angle, guide wire placement quality, operative time, intraoperative blood loss, fracture healing status, the Harris Hip Score, the 36-Item Short Form Health Survey, and the Zarit Caregiver Burden Score. The sample size calculation indicated that 150 (50%) participants per group (N=300) would be needed to detect a superiority margin of 15.4 fluoroscopy images with 80% power and a 1-sided α of .025, accounting for a 15% dropout rate. All patients will undergo 12 months of follow-up. Data analysis will compare groups using 1-sided t tests and Mann-Whitney U tests, supplemented by linear mixed-effects models with study site as a random effect. RESULTS The study was funded in May 2024 and received initial ethics approval from the institutional review board. Patient enrollment commenced in June 2024 and is projected to be completed by October 2026, with a target sample size of 300 participants. The final 12-month follow-up is expected to be completed by October 2027. As of manuscript submission, recruitment is ongoing, and no data analysis has been performed. CONCLUSIONS Successful completion of this study may introduce a new strategy for the management of FNF and help establish a standardized protocol for the use of navigation systems, potentially enhancing clinical outcomes and reducing complication rates. CLINICALTRIAL ClinicalTrials.gov NCT06713018; https://clinicaltrials.gov/study/NCT06713018 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/88180
- Open Access
- 4 September 2025
- Published by Springer Nature in Research Square
Is it necessary to add the medial plate for internal fixation of distal femur fractures? —Algorithm-based decision-making for medial plate application
Background and Objective: While double plate (DP) internal fixation is accepted due to its superior mechanical advantages in treating distal femur fractures (DFFs), it does not demonstrate a significant improvement in overall treatment outcomes when compared to lateral locking plate (LLP-only) fixation. We propose that this discrepancy arises from unclear indications. This study aims to develop an indication system based on mechanical factors to add medial plate. Methods We performed a finite element analysis (FEA) to examine the mechanical difference and principles of the LLP-only and DP fixations, with a total of 14 AO/ASIF A3 type fracture models with varying metaphyseal defect sizes. The corresponding mechanical indices, axial stiffness, axial micromotion, peak VMS of LLP under axial loading, torsional stiffness, torsional micromotion, peak VMS of LLP under torsional stiffness, were extracted from the FEA for analytical evaluation. Subsequently, we established an algorithmic system consisting of function fitting, analytic hierarchy process (AHP), and fuzzy comprehensive evaluation (FCE) to assess the appropriate indications for enhancing medial support. Furthermore, a retrospective study was conducted to evaluate the validity of algorithmic outcomes and screening cases of DFFs treated with LLP-only or DP fixations at our hospital between January 2018 and June 2023, and statistical analysis was performed. Results FEA demonstrated that as the metaphyseal defect increased from 0 to 30 mm, the results of axial and torsional loading experiments exhibited consistent changes. Specifically, the alterations were more pronounced in the LLP-only group. We identified 6 indicators to evaluate the mechanical effects of the two methods. Then, we utilized the algorithmic system to calculate suitability. For defects ranging 0-9.6 mm, the LLP-only sufficient is to meet union criteria. For defects exceeding 13.4 mm, the addition of a medial plate was necessary, while for defects between 9.6–13.4 mm, an assessment based on the patient's condition was required. According to the specified criteria, a total of 55 cases were ultimately included in the study, comprising 38 cases in LLP-only and 17 in DP. Lysholm score and knee ROM °, the group with defect size ≤ 13.4 mm demonstrated statistically superior outcomes compared to the group with larger defects. We applied receiver operating characteristics (ROC) analysis to determine the accuracy of results, AUC = 0.958 (95% CI 0.906-1.000). Conclusions We summarize the indications to add medial plates as delineated below: (1) Severe medial fractures of the distal femur; (2) Associated ligament damage; (3) Uncorrectable lower limb alignment deformities with LLP-only; (4) Poor bone quality, such as severe osteoporosis; (5) Defect size > 13.4 mm; and (6) For defects between 9.6 mm and 13.4 mm, if the patient has ligament damage, knee instability, a high BMI, significant demand for initial fixation strength, and could tolerate the surgery, then the addition of medial plates should be considered.
- 4 September 2025
- Published by Springer Nature in Research Square
Open AccessIs it necessary to add the medial plate for internal fixation of distal femur fractures? —Algorithm-based decision-making for medial plate application
Background and Objective: While double plate (DP) internal fixation is accepted due to its superior mechanical advantages in treating distal femur fractures (DFFs), it does not demonstrate a significant improvement in overall treatment outcomes when compared to lateral locking plate (LLP-only) fixation. We propose that this discrepancy arises from unclear indications. This study aims to develop an indication system based on mechanical factors to add medial plate. Methods We performed a finite element analysis (FEA) to examine the mechanical difference and principles of the LLP-only and DP fixations, with a total of 14 AO/ASIF A3 type fracture models with varying metaphyseal defect sizes. The corresponding mechanical indices, axial stiffness, axial micromotion, peak VMS of LLP under axial loading, torsional stiffness, torsional micromotion, peak VMS of LLP under torsional stiffness, were extracted from the FEA for analytical evaluation. Subsequently, we established an algorithmic system consisting of function fitting, analytic hierarchy process (AHP), and fuzzy comprehensive evaluation (FCE) to assess the appropriate indications for enhancing medial support. Furthermore, a retrospective study was conducted to evaluate the validity of algorithmic outcomes and screening cases of DFFs treated with LLP-only or DP fixations at our hospital between January 2018 and June 2023, and statistical analysis was performed. Results FEA demonstrated that as the metaphyseal defect increased from 0 to 30 mm, the results of axial and torsional loading experiments exhibited consistent changes. Specifically, the alterations were more pronounced in the LLP-only group. We identified 6 indicators to evaluate the mechanical effects of the two methods. Then, we utilized the algorithmic system to calculate suitability. For defects ranging 0-9.6 mm, the LLP-only sufficient is to meet union criteria. For defects exceeding 13.4 mm, the addition of a medial plate was necessary, while for defects between 9.6–13.4 mm, an assessment based on the patient's condition was required. According to the specified criteria, a total of 55 cases were ultimately included in the study, comprising 38 cases in LLP-only and 17 in DP. Lysholm score and knee ROM °, the group with defect size ≤ 13.4 mm demonstrated statistically superior outcomes compared to the group with larger defects. We applied receiver operating characteristics (ROC) analysis to determine the accuracy of results, AUC = 0.958 (95% CI 0.906-1.000). Conclusions We summarize the indications to add medial plates as delineated below: (1) Severe medial fractures of the distal femur; (2) Associated ligament damage; (3) Uncorrectable lower limb alignment deformities with LLP-only; (4) Poor bone quality, such as severe osteoporosis; (5) Defect size > 13.4 mm; and (6) For defects between 9.6 mm and 13.4 mm, if the patient has ligament damage, knee instability, a high BMI, significant demand for initial fixation strength, and could tolerate the surgery, then the addition of medial plates should be considered.
- Open Access
- 26 June 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (8) , 2435-2444
The Influence of Fracture Defect Size on Treatment Outcomes in Distal Femur Fractures: A Comparative Study Between Lateral Locking Plate and Double Plate Fixation
Objective: Double plate (DP) fixation does not significantly improve outcomes compared to lateral locking plate (LLP‐only) fixation for distal femur fractures (DFFs). We hypothesize this is due to the absence of clear indications for the application of these two fixation methods. This study aims to clarify the impact of metaphyseal defect size on the outcomes of these two treatments, in order to optimize surgical efficacy and minimize complications.Methods: We screened patients with distal femoral fractures treated with lateral locking plate or dual plate fixation at our hospital between January 2018 and June 2023 retrospectively. Information such as demographic data, fracture classification, operation details, metaphyseal bone defect size, pre‐nd post‐operative imaging data, and other medical records were compiled. Additionally, patients' recovery status was follow‐up, including evaluation of knee joint function (Lysholm score), range of motion (ROM), and EQ‐5D‐3L health score. We used diverse statistical methods for further analysis, such as t‐test, chi‐square test, Pearson correlation coefficients, and binary logistic regression analysis.Results: According to the specified criteria, 55 distal femur fracture cases were ultimately included, with 38 cases in the LLP‐only group and 17 cases in the DP fixation group. In terms of surgical and follow‐up information, there were no statistical differences in healing status, but there were statistically significant differences in average blood loss (p = 0.013), metaphyseal bone defect size (p < 0.001), Lysholm score (p = 0.003), and EQ‐5D score (p = 0.010). Notably, compared to other parameters, the size of the fracture defect exhibited the highest correlation (0.69) with healing outcomes. In logistic regression analysis, the defect size (OR 1.052, 95% CI 1.008–1.098, p = 0.021) was independently associated with the healing outcome. Upon further analysis, non‐healing cases in the LLP‐only group were predominantly associated with A3, C2, and C3 type fractures, with 83.3% of these patients presenting metaphyseal defects exceeding 15 mm.Conclusions: We carried out a comparative evaluation of LLP‐only versus DP fixation in addressing DFFs. Our research outcomes revealed that LLP‐only fixation yielded notably suboptimal results compared to DP fixation, especially in intricate fractures accompanied by defects, such as those classified under types A3, C2, and C3. Furthermore, the more significant the defect, the less effective the fixation of LLP‐only will be. This observation underscores the pivotal role of the scope of metaphysical damage in determining the most suitable internal fixation techniques for DFFs.
- 26 June 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (8) , 2435-2444
Open AccessThe Influence of Fracture Defect Size on Treatment Outcomes in Distal Femur Fractures: A Comparative Study Between Lateral Locking Plate and Double Plate Fixation
Objective: Double plate (DP) fixation does not significantly improve outcomes compared to lateral locking plate (LLP‐only) fixation for distal femur fractures (DFFs). We hypothesize this is due to the absence of clear indications for the application of these two fixation methods. This study aims to clarify the impact of metaphyseal defect size on the outcomes of these two treatments, in order to optimize surgical efficacy and minimize complications.Methods: We screened patients with distal femoral fractures treated with lateral locking plate or dual plate fixation at our hospital between January 2018 and June 2023 retrospectively. Information such as demographic data, fracture classification, operation details, metaphyseal bone defect size, pre‐nd post‐operative imaging data, and other medical records were compiled. Additionally, patients' recovery status was follow‐up, including evaluation of knee joint function (Lysholm score), range of motion (ROM), and EQ‐5D‐3L health score. We used diverse statistical methods for further analysis, such as t‐test, chi‐square test, Pearson correlation coefficients, and binary logistic regression analysis.Results: According to the specified criteria, 55 distal femur fracture cases were ultimately included, with 38 cases in the LLP‐only group and 17 cases in the DP fixation group. In terms of surgical and follow‐up information, there were no statistical differences in healing status, but there were statistically significant differences in average blood loss (p = 0.013), metaphyseal bone defect size (p < 0.001), Lysholm score (p = 0.003), and EQ‐5D score (p = 0.010). Notably, compared to other parameters, the size of the fracture defect exhibited the highest correlation (0.69) with healing outcomes. In logistic regression analysis, the defect size (OR 1.052, 95% CI 1.008–1.098, p = 0.021) was independently associated with the healing outcome. Upon further analysis, non‐healing cases in the LLP‐only group were predominantly associated with A3, C2, and C3 type fractures, with 83.3% of these patients presenting metaphyseal defects exceeding 15 mm.Conclusions: We carried out a comparative evaluation of LLP‐only versus DP fixation in addressing DFFs. Our research outcomes revealed that LLP‐only fixation yielded notably suboptimal results compared to DP fixation, especially in intricate fractures accompanied by defects, such as those classified under types A3, C2, and C3. Furthermore, the more significant the defect, the less effective the fixation of LLP‐only will be. This observation underscores the pivotal role of the scope of metaphysical damage in determining the most suitable internal fixation techniques for DFFs.
- 15 June 2025
- Vol. 39 (6) , 655-661
[Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures].
To evaluate the effectiveness of Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures. A retrospective analysis was conducted on 20 patients with bone defects complicating distal radius fractures who met the selection criteria and were treated between June 2022 and June 2024. The cohort comprised 2 males and 18 females, aged 54-87 years (mean, 63.3 years). Etiologies included falls in 17 cases, traffic accidents in 2 cases, and crush injury in 1 case. According to AO classification, there were 5 cases of type A, 8 cases of type B, and 7 cases of type C. The interval from injury to operation ranged from 2 to 10 days (mean, 5.8 days). All patients underwent volar plate fixation augmented with Poster Fusion Cage and demineralized xenogeneic bone matrix grafting. The operation time, intraoperative blood loss, fracture healing time, and postoperative complications were recorded. Radiographic parameters, including radial height, volar tilt, and ulnar deviation, were measured on standardized X-ray films obtained immediately postoperatively and at last follow-up, and whether secondary reduction loss occurred was judged. At last follow-up, wrist range of motion (extension, flexion, radial deviation, ulnar deviation, pronation, and supination) and grip strength (expressed as a percentage of the contralateral side) were measured. Wrist function was assessed using the Disabilities of the Arm, Shoulder, and Hand (DASH) score and Patient-Rated Wrist Evaluation (PRWE) score. The operation time was 70-200 minutes (mean, 116.4 minutes), and the intraoperative blood loss was 10-80 mL (mean, 36.5 mL). All surgical incisions healed by first intention, with no neurovascular complications documented. All patients were followed up 9-12 months (mean, 11.6 months). All fractures healed normally, with a healing time of 8-14 weeks (mean, 9.95 weeks). No significant difference was observed in radial height, volar tilt, or ulnar deviation between immediate postoperatively and last follow-up ( P>0.05). All fractures achieved satisfactory reduction, with no secondary loss of reduction or implant failure occurring during follow-up. At last follow-up, the range of motion of the affected wrist joint was 60°-65° (mean, 62.5°) in extension, 67°-75° (mean, 71.1°) in flexion, 18°-23° (mean, 20.4°) in radial deviation, 28°-33° (mean, 30.1°) in ulnar deviation, 69°-80° (mean, 74.7°) in pronation, and 69°-82° (mean, 75.6°) in supination. Grip strength recovered to 75%-85% (mean, 80%) of the contralateral side. Functional scores showed a DASH score of 5-15 (mean, 9.4) and PRWE score of 8.0-12.5 (mean, 10.2). The combination of Poster Fusion Cage and xenogeneic bone graft augmentation provides a safe and effective treatment for bone defects in distal radius fractures.
- 15 June 2025
- Vol. 39 (6) , 655-661
[Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures].
To evaluate the effectiveness of Poster Fusion Cage combined with xenogeneic bone graft augmentation for bone defect management in distal radius fractures. A retrospective analysis was conducted on 20 patients with bone defects complicating distal radius fractures who met the selection criteria and were treated between June 2022 and June 2024. The cohort comprised 2 males and 18 females, aged 54-87 years (mean, 63.3 years). Etiologies included falls in 17 cases, traffic accidents in 2 cases, and crush injury in 1 case. According to AO classification, there were 5 cases of type A, 8 cases of type B, and 7 cases of type C. The interval from injury to operation ranged from 2 to 10 days (mean, 5.8 days). All patients underwent volar plate fixation augmented with Poster Fusion Cage and demineralized xenogeneic bone matrix grafting. The operation time, intraoperative blood loss, fracture healing time, and postoperative complications were recorded. Radiographic parameters, including radial height, volar tilt, and ulnar deviation, were measured on standardized X-ray films obtained immediately postoperatively and at last follow-up, and whether secondary reduction loss occurred was judged. At last follow-up, wrist range of motion (extension, flexion, radial deviation, ulnar deviation, pronation, and supination) and grip strength (expressed as a percentage of the contralateral side) were measured. Wrist function was assessed using the Disabilities of the Arm, Shoulder, and Hand (DASH) score and Patient-Rated Wrist Evaluation (PRWE) score. The operation time was 70-200 minutes (mean, 116.4 minutes), and the intraoperative blood loss was 10-80 mL (mean, 36.5 mL). All surgical incisions healed by first intention, with no neurovascular complications documented. All patients were followed up 9-12 months (mean, 11.6 months). All fractures healed normally, with a healing time of 8-14 weeks (mean, 9.95 weeks). No significant difference was observed in radial height, volar tilt, or ulnar deviation between immediate postoperatively and last follow-up ( P>0.05). All fractures achieved satisfactory reduction, with no secondary loss of reduction or implant failure occurring during follow-up. At last follow-up, the range of motion of the affected wrist joint was 60°-65° (mean, 62.5°) in extension, 67°-75° (mean, 71.1°) in flexion, 18°-23° (mean, 20.4°) in radial deviation, 28°-33° (mean, 30.1°) in ulnar deviation, 69°-80° (mean, 74.7°) in pronation, and 69°-82° (mean, 75.6°) in supination. Grip strength recovered to 75%-85% (mean, 80%) of the contralateral side. Functional scores showed a DASH score of 5-15 (mean, 9.4) and PRWE score of 8.0-12.5 (mean, 10.2). The combination of Poster Fusion Cage and xenogeneic bone graft augmentation provides a safe and effective treatment for bone defects in distal radius fractures.
- Open Access
- 20 April 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (6) , 1791-1803
Feasibility and Mechanical Strength Evaluation of New Customized Implants for Tibial Plateau Fractures Fixation
Background and Objective: Customized implants could improve the capture of fracture fragments for strengthened stability of tibial plateau fractures (TPFs) fixation. This study aimed to validate the feasibility of customized implants through optimized manufacturing within a clinically acceptable timeframe and evaluate the mechanical strength of customized internal implants through finite element analysis.Methods: A retrospective was conducted. From May 1, 2023, to June 1, 2023, 10 patients with TPFs were treated at our hospital using various new internal fixation systems combined with customized technology. The indicators of patients characteristics, operation, and follow‐up were collected, such as the cause of trauma, fresh or old, fracture classification, blood loss, Lysholm score, EQ‐5D‐3L score, and so on. Additionally, we created a Schatzker IV TPF model with two separated fragments in the medial to compare the biomechanical strength and directional deformation between standard medial dual plates (MDPs) and medial customized plate (MCP).Results: The study found that the entire process of implant fabrication can be completed within a clinically acceptable timeframe of 3–4 days. We designed specific types of plates for different types of fractures, such as semi‐circumferential plates for lateral TPFs, γ‐type plates for medial TPFs, and pistol‐type and wing‐type plates for posterior TPFs. Follow‐up analysis showed operative times of 1.37 ± 0.58 h, intraoperative blood loss of 260 ± 179.20 mL, and favorable functional outcomes: Lysholm score 88.6 ± 4.93, knee ROM 103.5° ± 11.56°, and EQ‐5D‐3L score 0.87 ± 0.47. Additionally, the γ‐type plate showed comparable strength to the MDPs system via finite element analysis and demonstrated a more vital ability to resist the separation of fracture fragments, with the maximum displacement of MDPs (0.61878 mm) 2.4 times higher than that of MCP (0.26124 mm).Conclusions: Using customized internal fixation systems provided solutions to challenges of complex fractures, within a clinically acceptable timeframe of 3–4 days. Notably, the study showed that the strength of customized internal fixation systems of γ‐shaped plate was comparable to that of conventional implants. This innovative approach offered a new avenue for managing TPFs and even complex limb fractures.
- 20 April 2025
- Published by Wiley in Orthopaedic Surgery
- Vol. 17 (6) , 1791-1803
Open AccessFeasibility and Mechanical Strength Evaluation of New Customized Implants for Tibial Plateau Fractures Fixation
Background and Objective: Customized implants could improve the capture of fracture fragments for strengthened stability of tibial plateau fractures (TPFs) fixation. This study aimed to validate the feasibility of customized implants through optimized manufacturing within a clinically acceptable timeframe and evaluate the mechanical strength of customized internal implants through finite element analysis.Methods: A retrospective was conducted. From May 1, 2023, to June 1, 2023, 10 patients with TPFs were treated at our hospital using various new internal fixation systems combined with customized technology. The indicators of patients characteristics, operation, and follow‐up were collected, such as the cause of trauma, fresh or old, fracture classification, blood loss, Lysholm score, EQ‐5D‐3L score, and so on. Additionally, we created a Schatzker IV TPF model with two separated fragments in the medial to compare the biomechanical strength and directional deformation between standard medial dual plates (MDPs) and medial customized plate (MCP).Results: The study found that the entire process of implant fabrication can be completed within a clinically acceptable timeframe of 3–4 days. We designed specific types of plates for different types of fractures, such as semi‐circumferential plates for lateral TPFs, γ‐type plates for medial TPFs, and pistol‐type and wing‐type plates for posterior TPFs. Follow‐up analysis showed operative times of 1.37 ± 0.58 h, intraoperative blood loss of 260 ± 179.20 mL, and favorable functional outcomes: Lysholm score 88.6 ± 4.93, knee ROM 103.5° ± 11.56°, and EQ‐5D‐3L score 0.87 ± 0.47. Additionally, the γ‐type plate showed comparable strength to the MDPs system via finite element analysis and demonstrated a more vital ability to resist the separation of fracture fragments, with the maximum displacement of MDPs (0.61878 mm) 2.4 times higher than that of MCP (0.26124 mm).Conclusions: Using customized internal fixation systems provided solutions to challenges of complex fractures, within a clinically acceptable timeframe of 3–4 days. Notably, the study showed that the strength of customized internal fixation systems of γ‐shaped plate was comparable to that of conventional implants. This innovative approach offered a new avenue for managing TPFs and even complex limb fractures.