Paul Davey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paul Davey has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Mohammed Zaki Ahmed
School of Computing Electronics and Mathematics, Plymouth University
6 shared publicationsT. Donnelly
Plymouth University
5 shared publicationsD. Jenkins
University of Plymouth
3 shared publicationsD.J. Mapps
3 shared publicationsSaif Al-Zubaidi
University of Plymouth, Plymouth, UK
3 shared publications- Shakil Ahmed Awan
Nanomaterials and Devices Laboratory, School of Engineering, Computing and Mathematics, Faculty of Science and Engineering, University of Plymouth, Devon PL4 8AA, United Kingdom
3 shared publications
Latest Publications
- Open Access
- 5 November 2020
- Published by MDPI AG in Proceedings
- Vol. 60 (1) , 14
Graphene FET Sensors for Alzheimer’s Disease Protein Biomarker Clusterin Detection
We report on the fabrication and characterisation of Graphene field-effect transistor (GFET) Biosensors for detecting clusterin, a prominent protein biomarker of Alzheimer’s disease (AD). There are approximately 54 million people currently living with dementia worldwide and this is expected to rise to 130 million by 2050. Although there are over 400 different types of dementia, AD is the most common type, affecting between 50–75% of those diagnosed with dementia. Diagnosis of AD can take up to 2 years currently using MRI, PET, CT scans and memory tests. There is, therefore, an urgent need to develop low-cost, accurate, non-invasive and point-of-care (PoC) sensors for early diagnosis of AD. The GFET sensors we are developing to address this challenge were fabricated on Si/SiO2 substrate through processes of photolithographic patterning and metal lift-off techniques with evaporated chromium and sputtered gold contacts. Raman Spectroscopy was performed on the devices to determine the quality of the graphene. The GFETs were annealed to improve their performance before the channels were functionalized by immobilising the graphene surface with a linker molecule and anti-clusterin antibody. The detection was achieved through the binding reaction between the antibody and varying concentrations of clusterin antigen from 1 pg/mL to 1 ng/mL. The GFETs were characterized using 4-probe direct current (DC) electrical measurements which demonstrated a limit of detection of the biosensors to be below 1 pg/mL.
- 5 November 2020
- Published by MDPI AG in Proceedings
- Vol. 60 (1) , 14
Open AccessGraphene FET Sensors for Alzheimer’s Disease Protein Biomarker Clusterin Detection
We report on the fabrication and characterisation of Graphene field-effect transistor (GFET) Biosensors for detecting clusterin, a prominent protein biomarker of Alzheimer’s disease (AD). There are approximately 54 million people currently living with dementia worldwide and this is expected to rise to 130 million by 2050. Although there are over 400 different types of dementia, AD is the most common type, affecting between 50–75% of those diagnosed with dementia. Diagnosis of AD can take up to 2 years currently using MRI, PET, CT scans and memory tests. There is, therefore, an urgent need to develop low-cost, accurate, non-invasive and point-of-care (PoC) sensors for early diagnosis of AD. The GFET sensors we are developing to address this challenge were fabricated on Si/SiO2 substrate through processes of photolithographic patterning and metal lift-off techniques with evaporated chromium and sputtered gold contacts. Raman Spectroscopy was performed on the devices to determine the quality of the graphene. The GFETs were annealed to improve their performance before the channels were functionalized by immobilising the graphene surface with a linker molecule and anti-clusterin antibody. The detection was achieved through the binding reaction between the antibody and varying concentrations of clusterin antigen from 1 pg/mL to 1 ng/mL. The GFETs were characterized using 4-probe direct current (DC) electrical measurements which demonstrated a limit of detection of the biosensors to be below 1 pg/mL.
- Open Access
- 8 January 2018
- Published by MDPI AG in Diagnostics
- Vol. 8 (1) , 5
Label-Free Sensors Based on Graphene Field-Effect Transistors for the Detection of Human Chorionic Gonadotropin Cancer Risk Biomarker
We report on the development of label-free chemical vapour deposition (CVD) graphene field effect transistor (GFET) immunosensors for the sensitive detection of Human Chorionic Gonadotropin (hCG), a glycoprotein risk biomarker of certain cancers. The GFET sensors were fabricated on Si/SiO2 substrate using photolithography with evaporated chromium and sputtered gold contacts. GFET channels were functionalised with a linker molecule to an immobile anti-hCG antibody on the surface of graphene. The binding reaction of the antibody with varying concentration levels of hCG antigen demonstrated the limit of detection of the GFET sensors to be below 1 pg/mL using four-probe electrical measurements. We also show that annealing can significantly improve the carrier transport properties of GFETs and shift the Dirac point (Fermi level) with reduced p-doping in back-gated measurements. The developed GFET biosensors are generic and could find applications in a broad range of medical diagnostics in addition to cancer, such as neurodegenerative (Alzheimer’s and Parkinson’s ) and cardiovascular disorders.
- 8 January 2018
- Published by MDPI AG in Diagnostics
- Vol. 8 (1) , 5
Open AccessLabel-Free Sensors Based on Graphene Field-Effect Transistors for the Detection of Human Chorionic Gonadotropin Cancer Risk Biomarker
We report on the development of label-free chemical vapour deposition (CVD) graphene field effect transistor (GFET) immunosensors for the sensitive detection of Human Chorionic Gonadotropin (hCG), a glycoprotein risk biomarker of certain cancers. The GFET sensors were fabricated on Si/SiO2 substrate using photolithography with evaporated chromium and sputtered gold contacts. GFET channels were functionalised with a linker molecule to an immobile anti-hCG antibody on the surface of graphene. The binding reaction of the antibody with varying concentration levels of hCG antigen demonstrated the limit of detection of the GFET sensors to be below 1 pg/mL using four-probe electrical measurements. We also show that annealing can significantly improve the carrier transport properties of GFETs and shift the Dirac point (Fermi level) with reduced p-doping in back-gated measurements. The developed GFET biosensors are generic and could find applications in a broad range of medical diagnostics in addition to cancer, such as neurodegenerative (Alzheimer’s and Parkinson’s ) and cardiovascular disorders.
- Open Access
- 1 January 2017
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Telfor Journal
- Vol. 9 (1) , 38-42
Performance of 2D SOVA along and across track in shingled magnetic recording media
Serial Concatenation of Two Dimensional Soft Output Viterbi Algorithm (2D-SOVA) and regular Viterbi Algorithm (VA) for 2D equalisation and detection of Shingled Magnetic Recording (SMR) media provides excellent performance as compared to the use of 1 Dimensional (1D) maximum likelihood detector. In this paper, we implement and evaluate the performances of two versions of it. The first version performs 2D SOVA along the tracks to eliminate the effect of inter-symbol interference (ISI) and then the Viterbi detector across the tracks to remove inter-track interference (ITI). The second version carries out 2D-SOVA across the tracks and VA along the tracks. The results for high ITI and ISI show a better performance when using 2D-SOVA across the track with a small difference in computational complexity in favour of 2D-SOVA across the tracks.
- 1 January 2017
- Published by Centre for Evaluation in Education and Science (CEON/CEES) in Telfor Journal
- Vol. 9 (1) , 38-42
Open AccessPerformance of 2D SOVA along and across track in shingled magnetic recording media
Serial Concatenation of Two Dimensional Soft Output Viterbi Algorithm (2D-SOVA) and regular Viterbi Algorithm (VA) for 2D equalisation and detection of Shingled Magnetic Recording (SMR) media provides excellent performance as compared to the use of 1 Dimensional (1D) maximum likelihood detector. In this paper, we implement and evaluate the performances of two versions of it. The first version performs 2D SOVA along the tracks to eliminate the effect of inter-symbol interference (ISI) and then the Viterbi detector across the tracks to remove inter-track interference (ITI). The second version carries out 2D-SOVA across the tracks and VA along the tracks. The results for high ITI and ISI show a better performance when using 2D-SOVA across the track with a small difference in computational complexity in favour of 2D-SOVA across the tracks.
- 1 December 2016
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 16 (12) , 12805-12810
A Simple Approach to Preparation of Graphene/Reduced Graphene Oxide/Polyallylamine Electrode and Their Electrocatalysis for Hydrogen Peroxide Reduction
- 1 December 2016
- Published by American Scientific Publishers in Journal of Nanoscience and Nanotechnology
- Vol. 16 (12) , 12805-12810
A Simple Approach to Preparation of Graphene/Reduced Graphene Oxide/Polyallylamine Electrode and Their Electrocatalysis for Hydrogen Peroxide Reduction
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
An adaptable interleaved DC-DC boost converter
A new topology for an interleaved boost converter is presented in this paper. The circuit is able to provide high voltage gain without the need for using a large duty cycle. Analysis showing the effect of increasing inductor winding loss in relation to duty cycle is also presented. Losses in various components are considered and analysed. Finally, experimental results from a 200W prototype which was used to boost 25V to 300V are presented and verified the design.
- 1 September 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
An adaptable interleaved DC-DC boost converter
A new topology for an interleaved boost converter is presented in this paper. The circuit is able to provide high voltage gain without the need for using a large duty cycle. Analysis showing the effect of increasing inductor winding loss in relation to duty cycle is also presented. Losses in various components are considered and analysed. Finally, experimental results from a 200W prototype which was used to boost 25V to 300V are presented and verified the design.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 537-542
A new method to analyse eddy current loss in an integrated magnetic structure for boost converter
This paper proposes a new integrated structure for the interleaved boost converter. The structure includes the main windings and the multipliers on the same core. Where the single core boost topology would provide a minimum iron losses. A new method to calculate the eddy current loss for the used core is presented. The method takes into consideration the effect of the harmonics at different duty cycles on the eddy current and hysteresis losses in the core. A prototype was build and test was carried out to verify the performance.
- 1 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 537-542
A new method to analyse eddy current loss in an integrated magnetic structure for boost converter
This paper proposes a new integrated structure for the interleaved boost converter. The structure includes the main windings and the multipliers on the same core. Where the single core boost topology would provide a minimum iron losses. A new method to calculate the eddy current loss for the used core is presented. The method takes into consideration the effect of the harmonics at different duty cycles on the eddy current and hysteresis losses in the core. A prototype was build and test was carried out to verify the performance.
- Open Access
- 1 January 2016
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 25, S8
Outcome Comparison Between Endotracheal Intubation and Laryngeal Mask Airway Use in Out-of-hospital Cardiac Arrest: A New Zealand Registry Study
- 1 January 2016
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 25, S8
Open AccessOutcome Comparison Between Endotracheal Intubation and Laryngeal Mask Airway Use in Out-of-hospital Cardiac Arrest: A New Zealand Registry Study
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23295759,p. 1-8
A novel buck-boost DC-DC converter using close-coupled inductors
A new step-up-down DC-DC converter architecture is proposed, which utilises the close inversely-coupled inductors topology in both its conversion stages (bucking and boosting stages). The new converter aims to reduce the switching noise by reducing the back e.m.f induced in the main inductor by maintaining a continuous current through it and delivered to the load. This results in an increase in a conversion efficiency for this kind of converter dealing with wide range of supply voltages and serves a wide variety of applications. Circuit configuration, principles of operation, transfer function, simulated results and the experimental results are presented. The proposed concept is verified by the experimental results of a range of cases studies.
- 1 June 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23295759,p. 1-8
A novel buck-boost DC-DC converter using close-coupled inductors
A new step-up-down DC-DC converter architecture is proposed, which utilises the close inversely-coupled inductors topology in both its conversion stages (bucking and boosting stages). The new converter aims to reduce the switching noise by reducing the back e.m.f induced in the main inductor by maintaining a continuous current through it and delivered to the load. This results in an increase in a conversion efficiency for this kind of converter dealing with wide range of supply voltages and serves a wide variety of applications. Circuit configuration, principles of operation, transfer function, simulated results and the experimental results are presented. The proposed concept is verified by the experimental results of a range of cases studies.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High power factor single phase rectification technique with reduced line current harmonics
A single phase rectification technique with a new architecture and control scheme is proposed. The new circuit is constructed by connecting a single bidirectional switch and capacitor in parallel to the diode bridge rectifier. The control strategy is carefully designed to ensure the output voltage of the rectifier is above a chosen threshold and to maintain a high input power factor with reduced line current harmonics. Circuit configuration, design parameters, principles of operation and the mathematical analysis are presented. The proposed concept is verified by the experimental results over a range of cases studies. The experimental results are in accordance with the presented theory and confirmed the high input power factor with low harmonics content.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
High power factor single phase rectification technique with reduced line current harmonics
A single phase rectification technique with a new architecture and control scheme is proposed. The new circuit is constructed by connecting a single bidirectional switch and capacitor in parallel to the diode bridge rectifier. The control strategy is carefully designed to ensure the output voltage of the rectifier is above a chosen threshold and to maintain a high input power factor with reduced line current harmonics. Circuit configuration, design parameters, principles of operation and the mathematical analysis are presented. The proposed concept is verified by the experimental results over a range of cases studies. The experimental results are in accordance with the presented theory and confirmed the high input power factor with low harmonics content.