Daniel Gregório Chagas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel Gregório Chagas has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Cristiano Bigonha Tibiriçá
Heat Transfer Research Group, Department of Mechanical Engineering, Sao Carlos School of Engineering, University of São Paulo, São Carlos, Brazil
1 shared publication - Erivelto dos Santos Filho
Mechanical Engineering Department, São Carlos School of Engineering (EESC), University of São Paulo (USP), São Carlos, São Paulo, Brazil
1 shared publication - Guilherme Scagnolatto
Heat Transfer Research Group, Department of Mechanical Engineering, Sao Carlos School of Engineering, University of São Paulo, Av. Trab. São Carlense, 400, São Carlos SP 13566-590, Brazil
1 shared publication - Rodrigo Monteiro Oliveira
Heat Transfer Research Group, Department of Mechanical Engineering, Sao Carlos School of Engineering, University of São Paulo, Av. Trab. São Carlense, 400, São Carlos SP 13566-590, Brazil
1 shared publication - Álvaro Roberto Gardenghi
Heat Transfer Research Group, Mechanical Engineering Department, São Carlos School of Engineering, University of São Paulo, Trabalhador São-Carlense Avenue, São Carlos, São Paulo 13566-590, Brazil
1 shared publication
Latest Publications
- Open Access
Overview of Void Fraction Measurement Techniques, Databases and Correlations for Two-Phase Flow in Small Diameter Channels
Void fraction is one of the most important parameters for the modeling and characterization of two-phase flows. This manuscript presents an overview of void fraction measurement techniques, experimental databases and correlations, in the context of microchannel two-phase flow applications. Void fraction measurement techniques were reviewed and the most suitable techniques for microscale measurements were identified along its main characteristics. An updated void fraction experimental database for small channel diameter was obtained including micro and macrochannel two-phase flow data points. These data have channel diameter ranging from 0.5 to 13.84 mm, horizontal and vertical directions, and fluids such as air-water, R410a, R404a, R134a, R290, R12 and R22 for both diabatic and adiabatic conditions. New published void fraction correlations as well high cited ones were evaluated and compared to this small-diameter void fraction database in order to quantify the prediction error of them. Moreover, a new drift flux correlation for microchannels was also developed, showing that further improvement of available correlations is still possible. The new correlation was able to predict the microchannel database with mean absolute relative error of 9.8%, for 6% of relative improvement compared to the second-best ranked correlation for small diameter channels.
Open AccessOverview of Void Fraction Measurement Techniques, Databases and Correlations for Two-Phase Flow in Small Diameter Channels
Void fraction is one of the most important parameters for the modeling and characterization of two-phase flows. This manuscript presents an overview of void fraction measurement techniques, experimental databases and correlations, in the context of microchannel two-phase flow applications. Void fraction measurement techniques were reviewed and the most suitable techniques for microscale measurements were identified along its main characteristics. An updated void fraction experimental database for small channel diameter was obtained including micro and macrochannel two-phase flow data points. These data have channel diameter ranging from 0.5 to 13.84 mm, horizontal and vertical directions, and fluids such as air-water, R410a, R404a, R134a, R290, R12 and R22 for both diabatic and adiabatic conditions. New published void fraction correlations as well high cited ones were evaluated and compared to this small-diameter void fraction database in order to quantify the prediction error of them. Moreover, a new drift flux correlation for microchannels was also developed, showing that further improvement of available correlations is still possible. The new correlation was able to predict the microchannel database with mean absolute relative error of 9.8%, for 6% of relative improvement compared to the second-best ranked correlation for small diameter channels.