Xi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xi Zhang has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Yunlu Cai
School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China
3 shared publications- Zhaohui Li
School of Information Science and Engineering, Yanshan University, Qinhuangdao 066004, China; Hebei Key Laboratory of Information Transmission and Signal Processing, Yanshan University, Qinhuangdao 066004, China
3 shared publications - Cuiping Xu
Department of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
2 shared publications - Guojun Zhang
Department of Functional Neurosurgery, Beijing Children's Hospital, Capital Medical University, Beijing, China
2 shared publications - Kai Ma
Beijing Institute of Functional Neurosurgery, Department of Functional Neurosurgery, Xuanwu Hospital, Capital Medical University, Beijing, China
2 shared publications Weina Cai
School of Information Science and Engineering, Yanshan University, Qinhuangdao, 066004, China
2 shared publications
Latest Publications
- 24 September 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 437, 110914
Exponent-based hypergraph centrality for identifying vital nodes in higher-order brain networks
- 24 September 2026
- Published by Elsevier in Journal of Neuroscience Methods
- Vol. 437, 110914
Exponent-based hypergraph centrality for identifying vital nodes in higher-order brain networks
- 27 November 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (6) , 066020
Evaluating group interactions in epileptic brain networks by hypergraph and higher-order homophily
Objective. Group interactions capture cooperative dynamics among neural populations quantitatively, while also enabling precise detection of ensemble-level synchrony patterns and transcending the limitations of node-level relationships. To evaluate higher-order group interactions, we propose the PLASSO-homophily framework using multichannel stereo-electroencephalography (SEEG) recorded from patients with epilepsy. Approach. Specifically, we use phase locking value to improve least absolute shrinkage and selection operator method for constructing hypergraphs. Afterwards, we calculate affinity ratios between brain zones. Finally, we investigate higher-order interactions among different groups from a homophily perspective. The extremal result of strict homophily serves as a crucial theoretical framework for understanding homophily concepts, reflecting the constraints that different groups follow in higher-order interactions. Main results. It is observed that group interactions between seizure onset zones (SOZ), propagation zones (PZ) and non-involved zones (NIZ) present significant distinction across different seizure phases. In particular, the homophily of SOZ reaches a peak point during the seizure and sharply decreases in the post-seizure, with the most statistically significant differences on θ and γ bands. Furthermore, during the seizure, SOZ-PZ exhibits enhanced coupling while SOZ-NIZ exhibits impaired functional integration. Finally, among three groups, only SOZ exhibits strict monotonic and majority homophily. Significance. By analyzing changes in in-class and out-class connectivity, we quantitatively assess the activity levels and combinatorial constraints of the SOZ, PZ, and NIZ, thereby providing a novel perspective for exploring seizure mechanisms and developing epilepsy treatments.
- 27 November 2025
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 22 (6) , 066020
Evaluating group interactions in epileptic brain networks by hypergraph and higher-order homophily
Objective. Group interactions capture cooperative dynamics among neural populations quantitatively, while also enabling precise detection of ensemble-level synchrony patterns and transcending the limitations of node-level relationships. To evaluate higher-order group interactions, we propose the PLASSO-homophily framework using multichannel stereo-electroencephalography (SEEG) recorded from patients with epilepsy. Approach. Specifically, we use phase locking value to improve least absolute shrinkage and selection operator method for constructing hypergraphs. Afterwards, we calculate affinity ratios between brain zones. Finally, we investigate higher-order interactions among different groups from a homophily perspective. The extremal result of strict homophily serves as a crucial theoretical framework for understanding homophily concepts, reflecting the constraints that different groups follow in higher-order interactions. Main results. It is observed that group interactions between seizure onset zones (SOZ), propagation zones (PZ) and non-involved zones (NIZ) present significant distinction across different seizure phases. In particular, the homophily of SOZ reaches a peak point during the seizure and sharply decreases in the post-seizure, with the most statistically significant differences on θ and γ bands. Furthermore, during the seizure, SOZ-PZ exhibits enhanced coupling while SOZ-NIZ exhibits impaired functional integration. Finally, among three groups, only SOZ exhibits strict monotonic and majority homophily. Significance. By analyzing changes in in-class and out-class connectivity, we quantitatively assess the activity levels and combinatorial constraints of the SOZ, PZ, and NIZ, thereby providing a novel perspective for exploring seizure mechanisms and developing epilepsy treatments.
- 28 November 2024
- Published by Elsevier in Neural Networks
- Vol. 183, 106984
Estimating global phase synchronization by quantifying multivariate mutual information and detecting network structure
- 28 November 2024
- Published by Elsevier in Neural Networks
- Vol. 183, 106984
Estimating global phase synchronization by quantifying multivariate mutual information and detecting network structure
- Open Access
- 19 August 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (33) , e30114
Temporal-insular spreading time in temporal lobe epilepsy as a predictor of seizure outcome after temporal lobectomy
Insular involvement in temporal lobe epilepsy (TLE) has gradually been recognized since the widespread use of stereoelectroencephalography (SEEG). However, the correlation between insular involvement and failed temporal lobe surgery remains unclear. In this study, we analyzed the surgical outcomes of TLE patients who underwent temporal and insular SEEG recordings and explored the predictors of failed anterior temporal lobectomy (ATL) in these patients with temporal seizures. Forty-one patients who underwent ATL for drug-resistant TLE were examined using temporal and insular SEEG recordings. The clinical characteristics, SEEG data, and postoperative seizure outcomes of these patients were analyzed, and multivariate analysis was used to identify the predictors of surgical outcome. In this series, the ictal temporal discharges invaded the insula in 39 (95.1%) patients. Twenty-three (56.1%) patients were seizure-free (Engel class I) after ATL with at least 1 year follow-up. Only temporal-insular spreading time (TIST) was an independent predictor of postoperative seizure-free outcomes (P = .035). By creating receiver operating characteristic curves for TIST, 400 milliseconds was identified as the cutoff for classification. All patients were classified into 2 groups (TIST ≤ 400 milliseconds and TIST > 400 milliseconds) based on the cutoff value; the difference in seizure-free rates between the 2 groups was significant (P = .001). The very early insular involvement in TLE may be associated with poorer seizure outcomes after ATL. Our findings may be helpful for estimating the appropriate operative procedures and will be valuable for evaluating the prognosis of TLE patients with temporal-insular SEEG recordings and temporal lobectomy.
- 19 August 2022
- Published by Wolters Kluwer Health in Medicine
- Vol. 101 (33) , e30114
Open AccessTemporal-insular spreading time in temporal lobe epilepsy as a predictor of seizure outcome after temporal lobectomy
Insular involvement in temporal lobe epilepsy (TLE) has gradually been recognized since the widespread use of stereoelectroencephalography (SEEG). However, the correlation between insular involvement and failed temporal lobe surgery remains unclear. In this study, we analyzed the surgical outcomes of TLE patients who underwent temporal and insular SEEG recordings and explored the predictors of failed anterior temporal lobectomy (ATL) in these patients with temporal seizures. Forty-one patients who underwent ATL for drug-resistant TLE were examined using temporal and insular SEEG recordings. The clinical characteristics, SEEG data, and postoperative seizure outcomes of these patients were analyzed, and multivariate analysis was used to identify the predictors of surgical outcome. In this series, the ictal temporal discharges invaded the insula in 39 (95.1%) patients. Twenty-three (56.1%) patients were seizure-free (Engel class I) after ATL with at least 1 year follow-up. Only temporal-insular spreading time (TIST) was an independent predictor of postoperative seizure-free outcomes (P = .035). By creating receiver operating characteristic curves for TIST, 400 milliseconds was identified as the cutoff for classification. All patients were classified into 2 groups (TIST ≤ 400 milliseconds and TIST > 400 milliseconds) based on the cutoff value; the difference in seizure-free rates between the 2 groups was significant (P = .001). The very early insular involvement in TLE may be associated with poorer seizure outcomes after ATL. Our findings may be helpful for estimating the appropriate operative procedures and will be valuable for evaluating the prognosis of TLE patients with temporal-insular SEEG recordings and temporal lobectomy.
- Open Access
- 28 December 2021
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 135 (9) , 1087-1095
Prognostic value of high-frequency oscillations combined with multimodal imaging methods for epilepsy surgery
Background: The combination of high-frequency oscillations (HFOs) with single-mode imaging methods has been proved useful in identifying epileptogenic zones, whereas few studies have examined HFOs combined with multimodal imaging methods. The aim of this study was to evaluate the prognostic value of ripples, an HFO subtype with a frequency of 80 to 200 Hz is combined with multimodal imaging methods in predicting epilepsy surgery outcome. Methods: HFOs were analyzed in 21 consecutive medically refractory epilepsy patients who underwent epilepsy surgery. All patients underwent positron emission tomography (PET) and deep electrode implantation for stereo-electroencephalography (SEEG); 11 patients underwent magnetoencephalography (MEG). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in predicting surgical outcome were calculated for ripples combined with PET, MEG, both PET and MEG, and PET combined with MEG. Kaplan-Meier survival analyses were conducted in each group to estimate prognostic value. Results: The study included 13 men and 8 women. Accuracy for ripples, PET, and MEG alone in predicting surgical outcome was 42.9%, 42.9%, and 81.8%, respectively. Accuracy for ripples combined with PET and MEG was the highest. Resection of regions identified by ripples, MEG dipoles, and combined PET findings was significantly associated with better surgical outcome (P < 0.05). Conclusions: Intracranial electrodes are essential to detect regions which generate ripples and to remove these areas which indicate good surgical outcome for medically intractable epilepsy. With the assistance of presurgical noninvasive imaging examinations, PET and MEG, for example, the SEEG electrodes would identify epileptogenic regions more effectively.
- 28 December 2021
- Published by Wolters Kluwer Health in Chinese Medical Journal
- Vol. 135 (9) , 1087-1095
Open AccessPrognostic value of high-frequency oscillations combined with multimodal imaging methods for epilepsy surgery
Background: The combination of high-frequency oscillations (HFOs) with single-mode imaging methods has been proved useful in identifying epileptogenic zones, whereas few studies have examined HFOs combined with multimodal imaging methods. The aim of this study was to evaluate the prognostic value of ripples, an HFO subtype with a frequency of 80 to 200 Hz is combined with multimodal imaging methods in predicting epilepsy surgery outcome. Methods: HFOs were analyzed in 21 consecutive medically refractory epilepsy patients who underwent epilepsy surgery. All patients underwent positron emission tomography (PET) and deep electrode implantation for stereo-electroencephalography (SEEG); 11 patients underwent magnetoencephalography (MEG). Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in predicting surgical outcome were calculated for ripples combined with PET, MEG, both PET and MEG, and PET combined with MEG. Kaplan-Meier survival analyses were conducted in each group to estimate prognostic value. Results: The study included 13 men and 8 women. Accuracy for ripples, PET, and MEG alone in predicting surgical outcome was 42.9%, 42.9%, and 81.8%, respectively. Accuracy for ripples combined with PET and MEG was the highest. Resection of regions identified by ripples, MEG dipoles, and combined PET findings was significantly associated with better surgical outcome (P < 0.05). Conclusions: Intracranial electrodes are essential to detect regions which generate ripples and to remove these areas which indicate good surgical outcome for medically intractable epilepsy. With the assistance of presurgical noninvasive imaging examinations, PET and MEG, for example, the SEEG electrodes would identify epileptogenic regions more effectively.
- 30 October 2019
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 79 (8) , 579-583
Establishment of a reference procedure to measure urine-formed elements and evaluation of an automated urine analyzer
A standardized reference method is needed to accurately and precisely measure urine-formed elements (UFEs; red blood cells [RBCs], white blood cells [WBCs], and squamous epithelial cells [sECs]). We compared the results from a standard method with those from an automated analyzer. Trained technicians used standardized bright-field microscopy of fresh non-centrifuged urine samples, and disposable 1 µl chambers. Fifteen experienced technicians from 5 hospitals (3 per hospital) each performed 6 manual counts of 10 different native urine samples using a manual chamber and standard methods. The sEC counts were at least 50/µL, and the coefficient of variation (CV) was less than 14%; the RBC and WBC counts were at least 200/µL and the CVs were less than 7%. The same samples were also analyzed 6 times using automated analyzers. The means, CVs, and biases were determined. The median CVs for the manual measurements were 6.4% (WBCs), 6.6% (RBCs), and 12.7% (sECs). The CVs of the automated analyzer were 4.7% (WBCs), 5.6% (RBCs), and 9.2% (sECs). Biases between the automated and manual methods were −2.9% to 5.0%(WBCs), −0.8% to 8.8% (RBCs) and −2.8% to 9.4% (sECs). The count mean values and expanded uncertainties of these counts were (224.5 ± 15.0) cells/µL, (234.2 ± 16.2) cells/µL, and (61.5 ± 7.9) cells/µL, respectively. The standardized manual method for measuring UFEs had high precision and accuracy, making it a suitable reference method. Use of this reference method to calibrate an automated analyzer improved the accuracy of automated analysis.
- 30 October 2019
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 79 (8) , 579-583
Establishment of a reference procedure to measure urine-formed elements and evaluation of an automated urine analyzer
A standardized reference method is needed to accurately and precisely measure urine-formed elements (UFEs; red blood cells [RBCs], white blood cells [WBCs], and squamous epithelial cells [sECs]). We compared the results from a standard method with those from an automated analyzer. Trained technicians used standardized bright-field microscopy of fresh non-centrifuged urine samples, and disposable 1 µl chambers. Fifteen experienced technicians from 5 hospitals (3 per hospital) each performed 6 manual counts of 10 different native urine samples using a manual chamber and standard methods. The sEC counts were at least 50/µL, and the coefficient of variation (CV) was less than 14%; the RBC and WBC counts were at least 200/µL and the CVs were less than 7%. The same samples were also analyzed 6 times using automated analyzers. The means, CVs, and biases were determined. The median CVs for the manual measurements were 6.4% (WBCs), 6.6% (RBCs), and 12.7% (sECs). The CVs of the automated analyzer were 4.7% (WBCs), 5.6% (RBCs), and 9.2% (sECs). Biases between the automated and manual methods were −2.9% to 5.0%(WBCs), −0.8% to 8.8% (RBCs) and −2.8% to 9.4% (sECs). The count mean values and expanded uncertainties of these counts were (224.5 ± 15.0) cells/µL, (234.2 ± 16.2) cells/µL, and (61.5 ± 7.9) cells/µL, respectively. The standardized manual method for measuring UFEs had high precision and accuracy, making it a suitable reference method. Use of this reference method to calibrate an automated analyzer improved the accuracy of automated analysis.