Alicja Dabrowska
Alicja Dabrowska has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Bernhard Lendl
Institute of Chemical Technologies and Analytics TU Wien Vienna Austria
7 shared publications - Mauro David
Institute of Solid State Electronics, Technische Universität Wien, Gußhausstraße 25-25a, 1040 Vienna, Austria
4 shared publications Bernhard Lendl
3 shared publications- Borislav Hinkov
Silicon Austria Labs Villach Austria
3 shared publications - Gottfried Strasser
Institute of Solid State Electronics E362, Technische Universität Wien
3 shared publications - Andreas Schwaighofer
Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/164-UPA, Vienna, 1060, Austria
2 shared publications
Latest Publications
- Open Access
- 11 November 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 550
Investigating refractive index effects in bitumen ATR-FTIR spectroscopy
- 11 November 2026
- Published by Elsevier in Construction and Building Materials
- Vol. 550
Open AccessInvestigating refractive index effects in bitumen ATR-FTIR spectroscopy
- Open Access
- 20 July 2026
- Published by SAGE Publications in Applied Spectroscopy
Multi-Pathlength Mid-IR Spectroscopy of Proteins in Aqueous Solutions Using an External Cavity Quantum Cascade Laser
Mid-infrared spectroscopy is a powerful technique for probing molecular structure and composition, yet its application to aqueous systems remains limited by strong solvent absorption and the dynamic range of mid-IR detectors, which restrict the usable optical pathlength. Here, we present a quantum cascade laser-based spectroscopic setup that enables simultaneous acquisition of absorption spectra measured in transmission across a continuum of optical pathlengths using a custom-made wedge-shaped flow cell and a pyroelectric detector array. This design eliminates the need for mechanical adjustments or sample dilution, allowing direct analysis of complex liquid samples. We introduce the pathlength-to-noise ratio as a novel metric for determination of the optimal pathlength region for every wavenumber. By weighing detector signals based on this ratio, we achieve robust integration of multi-pathlength data into a single coherent mid-IR absorption spectrum. The system was validated using aqueous protein solutions of bovine serum albumin and β-lactoglobulin in the range of 1 to 25 mg mL -1 . Characteristic amide I and II bands were successfully resolved, and secondary structure differences were detected. This work establishes a flexible approach to mid-IR absorption spectroscopy, aiming to eliminate the limitations of detectors with a small dynamic range and to get a better understanding of the optimal pathlength for complex samples.
- 20 July 2026
- Published by SAGE Publications in Applied Spectroscopy
Open AccessMulti-Pathlength Mid-IR Spectroscopy of Proteins in Aqueous Solutions Using an External Cavity Quantum Cascade Laser
Mid-infrared spectroscopy is a powerful technique for probing molecular structure and composition, yet its application to aqueous systems remains limited by strong solvent absorption and the dynamic range of mid-IR detectors, which restrict the usable optical pathlength. Here, we present a quantum cascade laser-based spectroscopic setup that enables simultaneous acquisition of absorption spectra measured in transmission across a continuum of optical pathlengths using a custom-made wedge-shaped flow cell and a pyroelectric detector array. This design eliminates the need for mechanical adjustments or sample dilution, allowing direct analysis of complex liquid samples. We introduce the pathlength-to-noise ratio as a novel metric for determination of the optimal pathlength region for every wavenumber. By weighing detector signals based on this ratio, we achieve robust integration of multi-pathlength data into a single coherent mid-IR absorption spectrum. The system was validated using aqueous protein solutions of bovine serum albumin and β-lactoglobulin in the range of 1 to 25 mg mL -1 . Characteristic amide I and II bands were successfully resolved, and secondary structure differences were detected. This work establishes a flexible approach to mid-IR absorption spectroscopy, aiming to eliminate the limitations of detectors with a small dynamic range and to get a better understanding of the optimal pathlength for complex samples.
- Open Access
- 20 May 2026
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 13 (11) , 3026-3039
Mid-Infrared Sensing and Ultrafast Photoresponse in Silicon-Based Plasmonic Detectors
Mid-infrared photonics enables a large number of applications in chemical sensing, medical diagnostics, environmental monitoring, and optical communications, but widespread adoption of this technology is hindered by the lack of compact, CMOS-compatible photodetectors capable of room-temperature operation. This work presents an Al–Si–Al planar heterostructure acting as a plasmonic photodetector that leverages an electrostatically tunable Schottky barrier to detect sub-bandgap mid-infrared photons (5–7 μm) in silicon with a responsivity ∼0.9 mA/W, 2 dark current density, and a broad and uniform spectral response that does not require cooling. Fast internal dynamics with time constants of 3.7 ps and 1.4 ns are observed at 1560 nm, suggesting the potential for high-speed operation. Our monolithic and crystalline Al–Si heterostructure features abrupt interfaces obtained without epitaxy, ensuring CMOS compatibility and scalability. We demonstrate the potential of this device for mid-infrared sensing by detecting and spectrally characterizing water molecule absorption lines. By leveraging plasmonically generated hot-carriers combined with the inherent scalability of silicon-based technology, our work opens new pathways for cost-effective and high-speed infrared photodetectors suitable for next-generation integrated photonic systems.
- 20 May 2026
- Published by American Chemical Society (ACS) in ACS Photonics
- Vol. 13 (11) , 3026-3039
Open AccessMid-Infrared Sensing and Ultrafast Photoresponse in Silicon-Based Plasmonic Detectors
Mid-infrared photonics enables a large number of applications in chemical sensing, medical diagnostics, environmental monitoring, and optical communications, but widespread adoption of this technology is hindered by the lack of compact, CMOS-compatible photodetectors capable of room-temperature operation. This work presents an Al–Si–Al planar heterostructure acting as a plasmonic photodetector that leverages an electrostatically tunable Schottky barrier to detect sub-bandgap mid-infrared photons (5–7 μm) in silicon with a responsivity ∼0.9 mA/W, 2 dark current density, and a broad and uniform spectral response that does not require cooling. Fast internal dynamics with time constants of 3.7 ps and 1.4 ns are observed at 1560 nm, suggesting the potential for high-speed operation. Our monolithic and crystalline Al–Si heterostructure features abrupt interfaces obtained without epitaxy, ensuring CMOS compatibility and scalability. We demonstrate the potential of this device for mid-infrared sensing by detecting and spectrally characterizing water molecule absorption lines. By leveraging plasmonically generated hot-carriers combined with the inherent scalability of silicon-based technology, our work opens new pathways for cost-effective and high-speed infrared photodetectors suitable for next-generation integrated photonic systems.
- Open Access
- 20 March 2026
- Published by Elsevier in SSRN Electronic Journal
Investigating and Correcting Refractive Index Effects in Bitumen ATR-FTIR Spectroscopy
Attenuated Total Reflectance Fourier-Transform Infrared (ATR-FTIR) spectroscopy is widely used to characterise the ageing and modification of bitumen because of the molecular information it provides, its high signal-to-noise ratio, minimal sample preparation, and applicability to solid materials. However, interpretation of ATR-FTIR spectra remains challenging, particularly regarding baseline shifts observed during ageing or modification, which are not well understood yet. To tackle this issue, this study demonstrates that these baseline variations originate from changes in the real part of the refractive index of bitumen, which directly influence the penetration depth of the evanescent wave in ATR-FTIR measurements. By combining ATR-FTIR spectroscopy with ellipsometry, microscopy, and SARA fractionation, a quantitative relationship between refractive index evolution and spectral baseline behaviour was established for different binder sources, ageing states, polymer modifications, and filler additions. Using IR ellipsometry the refractive indices of the saturates, aromatics, resins, and asphaltenes (SARA fractions) were determined, and the changes in fractional composition affecting the bulk refractive index of bitumen was related to aliphatic band vibrations measured with FTIR.Based on these findings, a baseline correction model was developed to compensate for refractive-index-induced distortions in ATR-FTIR spectra. The corrected spectra allow extraction of a predicted bulk refractive index as an alternative ageing index, consistent with conventional markers such as carbonyl and sulfoxide band growth. This approach improves the quantitative reliability, comparability, and inter-laboratory consistency of ATR-FTIR-based ageing assessment.
- 20 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessInvestigating and Correcting Refractive Index Effects in Bitumen ATR-FTIR Spectroscopy
Attenuated Total Reflectance Fourier-Transform Infrared (ATR-FTIR) spectroscopy is widely used to characterise the ageing and modification of bitumen because of the molecular information it provides, its high signal-to-noise ratio, minimal sample preparation, and applicability to solid materials. However, interpretation of ATR-FTIR spectra remains challenging, particularly regarding baseline shifts observed during ageing or modification, which are not well understood yet. To tackle this issue, this study demonstrates that these baseline variations originate from changes in the real part of the refractive index of bitumen, which directly influence the penetration depth of the evanescent wave in ATR-FTIR measurements. By combining ATR-FTIR spectroscopy with ellipsometry, microscopy, and SARA fractionation, a quantitative relationship between refractive index evolution and spectral baseline behaviour was established for different binder sources, ageing states, polymer modifications, and filler additions. Using IR ellipsometry the refractive indices of the saturates, aromatics, resins, and asphaltenes (SARA fractions) were determined, and the changes in fractional composition affecting the bulk refractive index of bitumen was related to aliphatic band vibrations measured with FTIR.Based on these findings, a baseline correction model was developed to compensate for refractive-index-induced distortions in ATR-FTIR spectra. The corrected spectra allow extraction of a predicted bulk refractive index as an alternative ageing index, consistent with conventional markers such as carbonyl and sulfoxide band growth. This approach improves the quantitative reliability, comparability, and inter-laboratory consistency of ATR-FTIR-based ageing assessment.
- Open Access
- 25 July 2024
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 78 (9) , 982-992
Mid-Infrared Dispersion Spectroscopy as a Tool for Monitoring Time-Resolved Chemical Reactions on the Examples of Enzyme Kinetics and Mutarotation of Sugars
Ongoing technological advancements in the field of mid-infrared (MIR) spectroscopy continuously yield novel sensing modalities, offering capabilities beyond traditional techniques like Fourier transform infrared spectroscopy (FT-IR). One such advancement is MIR dispersion spectroscopy, utilizing a tunable quantum cascade laser and Mach–Zehnder interferometer for liquid-phase analysis. Our study assesses the performance of a custom MIR dispersion spectrometer at its current development stage, benchmarks its performance against FT-IR, and validates its potential for time-resolved chemical reaction monitoring. Unlike conventional methods of IR spectroscopy measuring molecular absorptions using intensity attenuation, our method detects refractive index changes (phase shifts) down to a level of 6.1 × 10 –7 refractive index units (RIU). This results in 1.5 times better sensitivity with a sevenfold increase in analytical path length, yielding heightened robustness for the analysis of liquids compared to FT-IR. As a case study, we monitor the catalytic activity of invertase with sucrose, observing the formation of resultant monosaccharides and their progression toward thermodynamic equilibrium. Anomalous refractive index spectra of reaction mixtures, with substrate concentrations ranging from 2.5 to 25 g/L, are recorded, and analyzed at various temperatures, yielding Michaelis–Menten kinetics findings comparable to the literature. Additionally, the first-time application of two-dimensional correlation spectroscopy on the recorded dynamic dispersion spectra correctly identifies the mutarotation of reaction products (glucose and fructose). The results demonstrate high precision and sensitivity in investigating complex time-dependent chemical reactions via broadband refractive index changes.
- 25 July 2024
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 78 (9) , 982-992
Open AccessMid-Infrared Dispersion Spectroscopy as a Tool for Monitoring Time-Resolved Chemical Reactions on the Examples of Enzyme Kinetics and Mutarotation of Sugars
Ongoing technological advancements in the field of mid-infrared (MIR) spectroscopy continuously yield novel sensing modalities, offering capabilities beyond traditional techniques like Fourier transform infrared spectroscopy (FT-IR). One such advancement is MIR dispersion spectroscopy, utilizing a tunable quantum cascade laser and Mach–Zehnder interferometer for liquid-phase analysis. Our study assesses the performance of a custom MIR dispersion spectrometer at its current development stage, benchmarks its performance against FT-IR, and validates its potential for time-resolved chemical reaction monitoring. Unlike conventional methods of IR spectroscopy measuring molecular absorptions using intensity attenuation, our method detects refractive index changes (phase shifts) down to a level of 6.1 × 10 –7 refractive index units (RIU). This results in 1.5 times better sensitivity with a sevenfold increase in analytical path length, yielding heightened robustness for the analysis of liquids compared to FT-IR. As a case study, we monitor the catalytic activity of invertase with sucrose, observing the formation of resultant monosaccharides and their progression toward thermodynamic equilibrium. Anomalous refractive index spectra of reaction mixtures, with substrate concentrations ranging from 2.5 to 25 g/L, are recorded, and analyzed at various temperatures, yielding Michaelis–Menten kinetics findings comparable to the literature. Additionally, the first-time application of two-dimensional correlation spectroscopy on the recorded dynamic dispersion spectra correctly identifies the mutarotation of reaction products (glucose and fructose). The results demonstrate high precision and sensitivity in investigating complex time-dependent chemical reactions via broadband refractive index changes.
- Open Access
- 16 November 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (47) , 16353-16360
Dual-Beam Photothermal Spectroscopy Employing a Mach–Zehnder Interferometer and an External Cavity Quantum Cascade Laser for Detection of Water Traces in Organic Solvents
We report on a mid-infrared (mid-IR) photothermal spectrometer for liquid-phase samples for the detection of water in organic solvents, such as ethanol or chloroform, and in complex mixtures, such as jet fuel. The spectrometer is based on a Mach-Zehnder interferometer (MZI) employing a He-Ne laser, a mini-flow cell with two embedded channels placed in the interferometer's arms, and a tunable external cavity quantum cascade laser (EC-QCL) for selective analyte excitation in a collinear arrangement. In this study, the bending vibration of water in the spectral range 1565-1725 cm-1 is targeted. The interferometer is locked to its quadrature point (QP) for most stable and automated operation. It provides a linear response with respect to the water content in the studied solvents and photothermal analyte spectra, which are in good agreement with FTIR absorbance spectra. The method is calibrated and validated against coulometric Karl Fischer (KF) titration, showing comparable performance and sensitivity. Limits of detection (LODs) for water detection in the single-digit ppm range were obtained for chloroform and jet fuel due to their low background absorption, whereas lower sensitivity has been observed for water detection in ethanol due to pronounced background absorption from the solvent. In contrast to KF titration, which requires toxic reagents and produces waste, the developed method works reagent-free. It can be applied in an online format in the chemical industry as well as for fuel quality control, being industrial applications where traces of water need to be accurately determined, preferably in real-time. It thus holds great promise as a green alternative to the offline KF titration method, which is the current standard method for this application.
- 16 November 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (47) , 16353-16360
Open AccessDual-Beam Photothermal Spectroscopy Employing a Mach–Zehnder Interferometer and an External Cavity Quantum Cascade Laser for Detection of Water Traces in Organic Solvents
We report on a mid-infrared (mid-IR) photothermal spectrometer for liquid-phase samples for the detection of water in organic solvents, such as ethanol or chloroform, and in complex mixtures, such as jet fuel. The spectrometer is based on a Mach-Zehnder interferometer (MZI) employing a He-Ne laser, a mini-flow cell with two embedded channels placed in the interferometer's arms, and a tunable external cavity quantum cascade laser (EC-QCL) for selective analyte excitation in a collinear arrangement. In this study, the bending vibration of water in the spectral range 1565-1725 cm-1 is targeted. The interferometer is locked to its quadrature point (QP) for most stable and automated operation. It provides a linear response with respect to the water content in the studied solvents and photothermal analyte spectra, which are in good agreement with FTIR absorbance spectra. The method is calibrated and validated against coulometric Karl Fischer (KF) titration, showing comparable performance and sensitivity. Limits of detection (LODs) for water detection in the single-digit ppm range were obtained for chloroform and jet fuel due to their low background absorption, whereas lower sensitivity has been observed for water detection in ethanol due to pronounced background absorption from the solvent. In contrast to KF titration, which requires toxic reagents and produces waste, the developed method works reagent-free. It can be applied in an online format in the chemical industry as well as for fuel quality control, being industrial applications where traces of water need to be accurately determined, preferably in real-time. It thus holds great promise as a green alternative to the offline KF titration method, which is the current standard method for this application.
- 9 March 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 48
Octave-spanning long-range plasmonic waveguide based on semiconductor-loading for mid-infrared monolithic sensors
Semiconductor-loaded plasmonic (SLSPP)-waveguides are a very efficient link for optoelectronic devices, facilitating miniaturized photonic integrated circuits. However, for long-wave infrared applications (8-12 µm), the material selection is challenging as most commonly used mid-IR materials absorb in this region. Therefore, we selected and investigated the properties of germanium in a hybrid semiconductor-metal-configuration to overcome these limitations. The experimental characterization of Si(substrate)-Au-Ge fabricated SLSPP-waveguides show very good agreement with FEM-simulations. Moreover, the realized devices offer low losses between 8.8 and 22 dB/mm (single device) and even within 8.8-15 dB/mm (multiple devices), respectively, for the entire investigated octave-spanning 5.6 – 11.2 µm range.
- 9 March 2022
- Published by SPIE-Intl Soc Optical Eng
- p. 48
Octave-spanning long-range plasmonic waveguide based on semiconductor-loading for mid-infrared monolithic sensors
Semiconductor-loaded plasmonic (SLSPP)-waveguides are a very efficient link for optoelectronic devices, facilitating miniaturized photonic integrated circuits. However, for long-wave infrared applications (8-12 µm), the material selection is challenging as most commonly used mid-IR materials absorb in this region. Therefore, we selected and investigated the properties of germanium in a hybrid semiconductor-metal-configuration to overcome these limitations. The experimental characterization of Si(substrate)-Au-Ge fabricated SLSPP-waveguides show very good agreement with FEM-simulations. Moreover, the realized devices offer low losses between 8.8 and 22 dB/mm (single device) and even within 8.8-15 dB/mm (multiple devices), respectively, for the entire investigated octave-spanning 5.6 – 11.2 µm range.
- Open Access
- 1 January 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 350
Broadband laser-based mid-infrared spectroscopy employing a quantum cascade detector for milk protein analysis
- 1 January 2022
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 350
Open AccessBroadband laser-based mid-infrared spectroscopy employing a quantum cascade detector for milk protein analysis
- Open Access
- 14 December 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (26) , 43567-43579
Octave-spanning low-loss mid-IR waveguides based on semiconductor-loaded plasmonics
Plasmonic waveguides are crucial building blocks for integrated on-chip mid-infrared (mid-IR) sensors, which have recently attracted great interest as a sensing platform to target enhanced molecular sensing. However, while hosting a wide range of applications from spectroscopy to telecommunication, the mid-IR lacks suitable broadband solutions that provide monolithic integration with III-V materials. This work reports a novel concept based on hybrid semiconductor-metal surface plasmon polariton waveguides, which result in experimentally demonstrated low loss and broadband devices. Composed of a thin germanium slab on top of a gold layer, the waveguiding properties can be directly controlled by changing the geometrical parameters. The measured losses of our devices are as low as 6.73 dB/mm at 9.12 µm and remain <15 dB/mm in the mid-IR range of 5.6–11.2 µm. The octave-spanning capability of the waveguides makes them ideal candidates for combination with broadband mid-IR quantum cascade laser frequency combs and integrated spectroscopic sensors.
- 14 December 2021
- Published by Optica Publishing Group in Optics Express
- Vol. 29 (26) , 43567-43579
Open AccessOctave-spanning low-loss mid-IR waveguides based on semiconductor-loaded plasmonics
Plasmonic waveguides are crucial building blocks for integrated on-chip mid-infrared (mid-IR) sensors, which have recently attracted great interest as a sensing platform to target enhanced molecular sensing. However, while hosting a wide range of applications from spectroscopy to telecommunication, the mid-IR lacks suitable broadband solutions that provide monolithic integration with III-V materials. This work reports a novel concept based on hybrid semiconductor-metal surface plasmon polariton waveguides, which result in experimentally demonstrated low loss and broadband devices. Composed of a thin germanium slab on top of a gold layer, the waveguiding properties can be directly controlled by changing the geometrical parameters. The measured losses of our devices are as low as 6.73 dB/mm at 9.12 µm and remain <15 dB/mm in the mid-IR range of 5.6–11.2 µm. The octave-spanning capability of the waveguides makes them ideal candidates for combination with broadband mid-IR quantum cascade laser frequency combs and integrated spectroscopic sensors.
- Open Access
- 18 November 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (24) , 36632-36642
Mid-IR refractive index sensor for detecting proteins employing an external cavity quantum cascade laser-based Mach-Zehnder interferometer
Novel laser light sources in the mid-infrared region enable new spectroscopy schemes beyond classical absorption spectroscopy. Herein, we introduce a refractive index sensor based on a Mach-Zehnder interferometer and an external-cavity quantum cascade laser that allows rapid acquisition of high-resolution spectra of liquid-phase samples, sensitive to relative refractive index changes down to 10−7. Dispersion spectra of three model proteins in deuterated solution were recorded at concentrations as low as 0.25 mg mL−1. Comparison with Kramers-Kronig-transformed Fourier transform infrared absorbance spectra revealed high conformance, and obtained figures of merit compare well with conventional high-end FTIR spectroscopy. Finally, we performed partial least squares-based multivariate analysis of a complex ternary protein mixture to showcase the potential of dispersion spectroscopy utilizing the developed sensor to tackle complex analytical problems. The results indicate that laser-based dispersion sensing can be successfully used for qualitative and quantitative analysis of proteins.
- 18 November 2020
- Published by Optica Publishing Group in Optics Express
- Vol. 28 (24) , 36632-36642
Open AccessMid-IR refractive index sensor for detecting proteins employing an external cavity quantum cascade laser-based Mach-Zehnder interferometer
Novel laser light sources in the mid-infrared region enable new spectroscopy schemes beyond classical absorption spectroscopy. Herein, we introduce a refractive index sensor based on a Mach-Zehnder interferometer and an external-cavity quantum cascade laser that allows rapid acquisition of high-resolution spectra of liquid-phase samples, sensitive to relative refractive index changes down to 10−7. Dispersion spectra of three model proteins in deuterated solution were recorded at concentrations as low as 0.25 mg mL−1. Comparison with Kramers-Kronig-transformed Fourier transform infrared absorbance spectra revealed high conformance, and obtained figures of merit compare well with conventional high-end FTIR spectroscopy. Finally, we performed partial least squares-based multivariate analysis of a complex ternary protein mixture to showcase the potential of dispersion spectroscopy utilizing the developed sensor to tackle complex analytical problems. The results indicate that laser-based dispersion sensing can be successfully used for qualitative and quantitative analysis of proteins.