  • Open Access

    Complex Vector Admittance Modeling and Stability Analysis of FSC-VSPSUs Under Rapid Speed Mode

    by Huabo Shi, Liang Wang, Zanao Hu, Hanghang He, Pengyu Pan, Jianyong Song, Ning Jiao, Shunliang Wang

    Full-size converter variable-speed pumped storage units (FSC-VSPSUs) feature bidirectional power flow. They serve as critical equipment for enhancing regulation margins and promoting renewable energy integration. However, bidirectional energy flow elevates oscillations and instability risks. To address this issue, this paper establishes a complex-vector model of the FSC-VSPSU based on dc-bus decoupling and reveals the underlying mechanism of the internal frequency coupling effect. Comparing the coupling admittance of the FSC-VSPSU with that of a traditional grid-following converter (GFL) reveals that a pair of coupling peaks, absent in traditional converters, appear near the fundamental frequency of the FSC-VSPSU, with the admittance magnitude reaching twice that of the grid-following converter. The influencing factors of system stability under generating and pumping modes are comparatively analyzed using the impedance criterion. This indicates that the machine-side parameters exert a relatively minor impact on grid-connected stability. But the system presents a greater instability risk in pumping mode than in generating mode. Finally, the simulation results validate the correctness of the theoretical analysis presented in this paper.

  • Open Access

    Decentralised Hybrid Current/Voltage‐Mode Control Strategy Based on Self‐Synchronisation for CHB Converters

    by Shunliang Wang, Aiwen Wang, Ning Jiao, Junpeng Ma, Hao Tu, Tianqi Liu

    Cascaded H‐bridge (CHB) multilevel converters are a pivotal topology for emerging applications like solid‐state transformers (SSTs) and medium‐voltage DC (MVDC) collection systems. However, traditional schemes rely on high‐bandwidth communication for module synchronization and require point‐of‐common‐coupling (PCC) voltage sensors. They compromise system reliability and scalability while increasing hardware costs and are particularly vulnerable in weak‐grid scenarios. To address these issues, this paper proposes a novel decentralised hybrid current‐/voltage‐mode (CVM) control strategy based on self‐synchronisation. It completely eliminates the reliance on high‐bandwidth communication. Meanwhile, by introducing self‐synchronisation control into the current control module (CCM), the phase‐locked loop (PLL) instability under weak grids is effectively overcome. Furthermore, by enabling autonomous phase regulation in voltage control modules (VCM), the concentrated voltage compensation burden on the current‐control module is mitigated. This theoretically reduces the risk of single module over‐modulation. Finally, hardware‐in‐the‐loop experimental results validate the effectiveness of the proposed method.

  • A Device Multiplexing DC Chopper Topology for VSC-HVDC System

    by Wentao Li, Shunliang Wang, Hao Tu, Junpeng Ma, Ning Jiao, Tianqi Liu, Huabo Shi, Yufei Teng

  • Accurate and Continuous Reactive Power Control of Three-Terminal Hybrid DC Transmission System

    by Shunliang Wang, Qinger Cheng, Boyang Shangguan, Junpeng Ma, Ning Jiao, Tianqi Liu

    Hybrid high voltage direct current transmission (HVDC) can avoid commutation failure of line commutated converter based HVDC (LCC-HVDC) and high costs from modular multilevel converter based HVDC (MMC-HVDC). The uncontrollability of reactive power from LCC results in the control performance of hybrid HVDC that is not comparable to MMC-HVDC. To address this shortcoming, a mathematical model with all AC and DC side characteristics of a three-terminal hybrid HVDC system is established. Then, the quantitative relationship between the reactive power, AC bus voltage, and control variables of three converter stations is revealed. Through this analysis, a coordinated control strategy that can achieve continuous and precise control of reactive power and AC bus voltage is proposed. This strategy is achieved by utilizing the self-regulating capabilities of the converter stations. Besides, the DC voltage is ensured to remain within a reasonable range through the coordinated operation of capacitor banks. Moreover, error feedback and gamma-kick are added to make the control objective more accurate. Finally, the simulation results indicate that the proposed reactive power coordination control strategy demonstrates ideal control performance.


  • Open Access

    Quantitative Analysis of Balancing Range for Single-Phase 3L-NPC Converters

    by Ziying Wang, Ning Jiao, Shunliang Wang, Junpeng Ma, Rui Zhang, Tianqi Liu

    Multiple techniques have been suggested to achieve control balance in single-phase three-level neutral-point clamped (3L-NPC) converters. Nevertheless, there is a deficiency of quantitative calculations related to the extent of balancing. Operating beyond the balancing range may result in a sequence of safety incidents. This paper presents a conceptualization of the 3L-NPC converter as two cascaded H-bridges. By employing power conservation principles, the balancing range for the NPC converter is derived, and two novel methods are investigated to broaden the balance range in accordance with the calculated balance range. A comparison is made among the balancing ranges under different balancing control methods. This study establishes a theoretical foundation to ensure the secure and stable operation of the NPC converter.

  • Common Mode Voltage Suppression for Three-Level Neutral Point-Clamped Inverters

    by Lingjun Yao, Hao Luo, Ning Jiao, Yongheng Yang

    The three-phase neutral point-clamped (NPC) three-level inverter is widely employed in renewable energy power systems due to its low voltage stress on switching devices, low harmonic, and high efficiency. However, the common mode voltage (CMV) issue is a concern. To address the CMV issue, modulation should be enhanced in combination with advanced control and topological innovation. Hence, this paper explores the modulation schemes for NPC inverters to reduce or eliminate CMV. Additionally, three operation modes (i.e., synchronous, interleaving, and integrated modes) for parallel NPC inverters are discussed. The effectiveness of CMV suppression and harmonic characteristics of the explored modulation schemes and operation modes are compared and analyzed through simulations.

  • DC-Link Voltages Digital Sampling for Cascaded H-Bridge Rectifiers With Single Voltage Sensor Under Loads Unbalanced Condition

    by Yushi Yang, Junpeng Ma, Shunliang Wang, Zhong Wang, Ning Jiao, Tianqi Liu, Zihao Wu

    Direct current (dc) voltage sensor in each cell of the cascaded H-bridge rectifier (CHBR) is traditionally indispensable for capacitor voltage balancing control. The cost of dc sensors will increase with the number of cells. This letter proposes a strategy for dc-voltage digital sampling based on sliding window recursive least square (RLS), which employs only one voltage sensor. Sliding window RLS is used to decouple voltage information within one sampling interval. For the actual situation where the modulation waves of cells are different, this method owns faster updating rate and higher detection precision compared to the existing multisampling method. A downscale test platform of the single-phase CHBR is built to verify the correctness and effectiveness of the proposed method. The result shows that better current quality and steadier dc voltage are achieved.


  • The Closed-Loop Sideband Harmonic Suppression for CHB Inverter With Unbalanced Operation

    by Ning Jiao, Shunliang Wang, Junpeng Ma, Xiang Chen, Tianqi Liu, Dao Zhou, Yongheng Yang

    For N-cells cascaded H-bridge (CHB) inverters based on unipolar double frequency phase-shifted pulsewidth modulation (PS-PWM), the output voltage is distorted and its harmonics are difficult to be suppressed under unbalanced conditions (different dc voltages and/or modulation indices). This article proposes a closed-loop harmonic suppression scheme based on the PS-PWM, and the scheme is easily implemented in the dq frame to adaptively adjust the displacement angles of the triangular carriers. The harmonic content can be suppressed to its possible minimum value without the limitation of the operational point by the proposed method. The adjustment rules of displacement angles and the harmonic suppression principle are presented in detail. This method can effectively restrain harmonic magnitudes without the limitation of the cells number and does not require complicated trigonometric function calculations or optimization algorithms. Moreover, the principle of symmetrical sideband harmonic suppression is also discussed. The effectiveness of the proposed method is verified by a downscale test platform of the single-phase CHB inverter.


  • Influencing Factors of Harmonic Coupling in Modular Multilevel Converter

    by Ning Jiao, Shunliang Wang, Junpeng Ma, Tianqi Liu

    The feature of the modular multilevel converter (MMC) may worse the power quality,due to the additional harmonics caused by the harmonic coupling between the grid and the dc bus. It is difficult to analyze the influencing factors of harmonic coupling in MMC,since harmonic coupling processes are complicated. In this article,the mechanism of harmonic coupling of the MMC is analyzed first,considering that harmonics exist in the grid and dc side. The influencing factors of harmonic coupling are ana-lyzed based on the harmonic coupling model. The reference for the filter and MMC design,and the evaluation of the harmonic pollution can be provided by the analysis in this article. The cor-rectness of the influencing factors has been proved by simulation and experimental tests.


  • Open Access

    Accurate Analysis of Harmonic Transmission of Line Commutated Converter Considering Firing Angle Fluctuation

    by He Huang, Junpeng Ma, Shunliang Wang, Yuqing Dong, Ning Jiao, Tianqi Liu

    Line commutated converter (LCC) has been widely applied in hybrid high voltage direct current (HVDC) transmission system, where the modular multilevel converter (MMC) is applied as receiving end and may induce low order harmonics in DC-link voltage. These low order harmonics will introduce the low frequency fluctuation into the control loop of LCC and complex the harmonics analysis. The traditional method to calculate LCC harmonics is derived by the switching function and modulation theory, which only obtains characteristic harmonics. The low-frequency fluctuation superimposed on the firing angle in the control system is ignored in the traditional method. In this paper, the interharmonics, which is introduced by firing angle fluctuation, is revealed by the double Fourier method. A fitting function method is applied for depicting the varied commutation overlap caused by firing angle fluctuation. Compared to the traditional method, the proposed method can effectively analyze both characteristic harmonics and interharmonics in the condition of low-frequency fluctuation of the firing angle. The accuracy and effectiveness of the theoretical analysis are verified with a three-phase LCC rectifier built in PSCAD/EMTDC and experimental test.