Pritam Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Pritam Sharma has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Adrian Keating
Univ Western Australia, Sch Engn, 35 Stirling Hwy, Crawley, WA 6009, Australia
4 shared publicationsGiacinta Parish
Univ Western Australia, Sch Engn, 35 Stirling Hwy, Crawley, WA 6009, Australia
3 shared publications- Giacinta Parish
Department of Electrical Electronic and Computer Engineering University of Western Australia 35 Stirling Hwy Crawley 6009 Australia
2 shared publications - John M. Dell
Department of Electrical Electronic and Computer Engineering University of Western Australia 35 Stirling Hwy Crawley 6009 Australia
2 shared publications - Nicolas Hans Voelcker
Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Australia
2 shared publications - Adrian Keating
Department of Electrical Electronic and Computer Engineering University of Western Australia 35 Stirling Hwy Crawley 6009 Australia
1 shared publication
Latest Publications
- Open Access
- 4 June 2025
- Published by Wiley in Advanced Sensor Research
- Vol. 4 (11)
Implantable, Label‐Free NIR‐Based Porous Silicon Biosensor for Monitoring Biomarkers in Interstitial Fluid
The detection of biomarkers in interstitial fluid (ISF) holds significant promise for early disease diagnosis and monitoring. Porous silicon (pSi) offers a versatile platform for implantable biosensors due to its biocompatibility, high surface area, and tunable properties. This study presents the development and characterization of a label‐free pSi biosensor featuring a near‐infrared (NIR) photonic microcavity (MC) that is implanted subcutaneously in a euthanized mouse to detect insulin in real time for proof of concept. The biosensor demonstrates specific insulin detection ability with a limit of detection (LOD) of 209 nM, exhibiting excellent consistency, reproducibility, and long‐term sensing performance. Furthermore, the biosensor demonstrates the capability to detect insulin spiked into plasma obtained from a healthy mouse. It is further reported that a simple and sensitive data analysis method, the effective shift in wavelength (ESW) method for measuring the shift in center wavelength of the photonic MC. This viable approach can be extended to other photonic biosensors where measurements are limited by the resolution of the spectrometer. The proposed approach lays the foundation for the development of pSi‐based implantable biosensors for real‐time continuous monitoring of clinically relevant biomarkers in vivo for chronic disease management.
- 4 June 2025
- Published by Wiley in Advanced Sensor Research
- Vol. 4 (11)
Open AccessImplantable, Label‐Free NIR‐Based Porous Silicon Biosensor for Monitoring Biomarkers in Interstitial Fluid
The detection of biomarkers in interstitial fluid (ISF) holds significant promise for early disease diagnosis and monitoring. Porous silicon (pSi) offers a versatile platform for implantable biosensors due to its biocompatibility, high surface area, and tunable properties. This study presents the development and characterization of a label‐free pSi biosensor featuring a near‐infrared (NIR) photonic microcavity (MC) that is implanted subcutaneously in a euthanized mouse to detect insulin in real time for proof of concept. The biosensor demonstrates specific insulin detection ability with a limit of detection (LOD) of 209 nM, exhibiting excellent consistency, reproducibility, and long‐term sensing performance. Furthermore, the biosensor demonstrates the capability to detect insulin spiked into plasma obtained from a healthy mouse. It is further reported that a simple and sensitive data analysis method, the effective shift in wavelength (ESW) method for measuring the shift in center wavelength of the photonic MC. This viable approach can be extended to other photonic biosensors where measurements are limited by the resolution of the spectrometer. The proposed approach lays the foundation for the development of pSi‐based implantable biosensors for real‐time continuous monitoring of clinically relevant biomarkers in vivo for chronic disease management.
- 6 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (2) , 2814-2843
Advancements in Porous Silicon Biosensors for Point of Care, Wearable, and Implantable Applications
Biosensors play a critical role in modern diagnostics, offering high sensitivity and specificity for detecting various relevant clinical analytes as well as real-time monitoring and integrability in point-of-care (POC) platforms and wearable/implantable devices. Among the numerous materials used as biosensing substrates, porous silicon (pSi) has garnered significant attention due to its tunable properties, ease of fabrication, large surface area, and versatile surface chemistry. These attributes make pSi an ideal platform for transducer development, particularly in the fabrication of optical and electrochemical biosensors. This review explores the various stages of the design of a pSi-based biosensor starting from pSi fabrication, followed by a deep study about the stabilization and functionalization techniques providing a comparative analysis of their performance. Moreover, we survey the reported designs categorized as optical and electrochemical sensors, presenting a critical evaluation of their analytical validity as well as identifying the challenges of bringing these devices to the clinical practice. By bridging existing knowledge gaps, this review aims to inspire future innovation, providing valuable insights into how pSi-based biosensors can be further optimized for noninvasive diagnostics, personalized healthcare, and early disease detection leading to a doable commercialization.
- 6 January 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (2) , 2814-2843
Advancements in Porous Silicon Biosensors for Point of Care, Wearable, and Implantable Applications
Biosensors play a critical role in modern diagnostics, offering high sensitivity and specificity for detecting various relevant clinical analytes as well as real-time monitoring and integrability in point-of-care (POC) platforms and wearable/implantable devices. Among the numerous materials used as biosensing substrates, porous silicon (pSi) has garnered significant attention due to its tunable properties, ease of fabrication, large surface area, and versatile surface chemistry. These attributes make pSi an ideal platform for transducer development, particularly in the fabrication of optical and electrochemical biosensors. This review explores the various stages of the design of a pSi-based biosensor starting from pSi fabrication, followed by a deep study about the stabilization and functionalization techniques providing a comparative analysis of their performance. Moreover, we survey the reported designs categorized as optical and electrochemical sensors, presenting a critical evaluation of their analytical validity as well as identifying the challenges of bringing these devices to the clinical practice. By bridging existing knowledge gaps, this review aims to inspire future innovation, providing valuable insights into how pSi-based biosensors can be further optimized for noninvasive diagnostics, personalized healthcare, and early disease detection leading to a doable commercialization.
- Open Access
- 16 July 2024
- Published by Elsevier in Applied Materials Today
- Vol. 39
Micromachining porous silicon thin films for thermal sensing applications
- 16 July 2024
- Published by Elsevier in Applied Materials Today
- Vol. 39
Open AccessMicromachining porous silicon thin films for thermal sensing applications
- Open Access
- 2 December 2023
- Published by Elsevier in Applied Materials Today
- Vol. 35
Using multilayer structures to enhance the electrical properties of porous silicon for thermal sensing
- 2 December 2023
- Published by Elsevier in Applied Materials Today
- Vol. 35
Open AccessUsing multilayer structures to enhance the electrical properties of porous silicon for thermal sensing
- 1 September 2021
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 324, 111302
Engineering 1/f noise in porous silicon thin films for thermal sensing applications
- 1 September 2021
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 324, 111302
Engineering 1/f noise in porous silicon thin films for thermal sensing applications
- 1 January 2021
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 312
Enabling high-porosity porous silicon as an electronic material
- 1 January 2021
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 312
Enabling high-porosity porous silicon as an electronic material
- 1 January 2021
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 312
Optimising porous silicon electrical properties for thermal sensing applications
- 1 January 2021
- Published by Elsevier in Microporous and Mesoporous Materials
- Vol. 312
Optimising porous silicon electrical properties for thermal sensing applications
- 30 August 1999
- Published by AIP Publishing in Applied Physics Letters
- Vol. 75 (9) , 1273-1275
Temperature-dependent morphology of three-dimensional InAs islands grown on silicon
- 30 August 1999
- Published by AIP Publishing in Applied Physics Letters
- Vol. 75 (9) , 1273-1275
Temperature-dependent morphology of three-dimensional InAs islands grown on silicon