Joel Ramjist
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Joel Ramjist has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Victor Xiao Dong Yang
Ryerson Univ. (Canada)
6 shared publications - Christopher R. Pasarikovski
Division of Neurosurgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
3 shared publications Jamil Jivraj
Ryerson Univ. (Canada)
3 shared publications- Jerry C. Ku
Sunnybrook Health Sciences Centre, Division of Neurosurgery, University of Toronto, Toronto (ON), Canada
3 shared publications - Yuta Dobashi
Institute of Medical Science University of Toronto Toronto Ontario M5S 1A1 Canada
3 shared publications Andrew J. Marques
Ryerson Univ. (Canada)
1 shared publication
Latest Publications
- Open Access
- 3 February 2023
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (12) , e2202632
Photomodulated Extrusion as a Localized Endovascular Hydrogel Deposition Method
Minimally invasive endovascular embolization is used to treat a wide range of diseases in neurology, oncology, and trauma where the vascular morphologies and corresponding hemodynamics vary greatly. Current techniques based on metallic coils, flow diverters, liquid embolics, and suspended microspheres are limited in their ability to address a wide variety of vasculature and can be plagued by complications including distal migration, compaction, and inappropriate vascular remodeling. Further, these endovascular devices currently offer limited therapeutic functions beyond flow control such as drug delivery. Herein, a novel in situ microcatheter‐based photomodulated extrusion approach capable of dynamically tuning the physical and morphological properties of injectable hydrogels, optimizing for local hemodynamic environment and vascular morphology, is proposed and demonstrated. A shear thinning and photoactivated poly(ethylene glycol diacrylate)‐nanosilicate (PEGDA‐nSi) hydrogel is used to demonstrate multiple extrusion modes which are controlled by photokinetics and device configurations. Real‐time photomodulation of injected hydrogel viscosity and modulus is successfully used for embolization in various vasculatures, including high‐flow large vessels and arterial‐to‐arterial capillary shunts. Furthermore, a generalizable therapeutic delivery platform is proposed by demonstrating a core–shell structured extrusion encapsulating doxorubicin to achieve a more sustained release compared to unencapsulated payload.
- 3 February 2023
- Published by Wiley in Advanced Healthcare Materials
- Vol. 12 (12) , e2202632
Open AccessPhotomodulated Extrusion as a Localized Endovascular Hydrogel Deposition Method
Minimally invasive endovascular embolization is used to treat a wide range of diseases in neurology, oncology, and trauma where the vascular morphologies and corresponding hemodynamics vary greatly. Current techniques based on metallic coils, flow diverters, liquid embolics, and suspended microspheres are limited in their ability to address a wide variety of vasculature and can be plagued by complications including distal migration, compaction, and inappropriate vascular remodeling. Further, these endovascular devices currently offer limited therapeutic functions beyond flow control such as drug delivery. Herein, a novel in situ microcatheter‐based photomodulated extrusion approach capable of dynamically tuning the physical and morphological properties of injectable hydrogels, optimizing for local hemodynamic environment and vascular morphology, is proposed and demonstrated. A shear thinning and photoactivated poly(ethylene glycol diacrylate)‐nanosilicate (PEGDA‐nSi) hydrogel is used to demonstrate multiple extrusion modes which are controlled by photokinetics and device configurations. Real‐time photomodulation of injected hydrogel viscosity and modulus is successfully used for embolization in various vasculatures, including high‐flow large vessels and arterial‐to‐arterial capillary shunts. Furthermore, a generalizable therapeutic delivery platform is proposed by demonstrating a core–shell structured extrusion encapsulating doxorubicin to achieve a more sustained release compared to unencapsulated payload.
- Open Access
- 4 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10024, 37
Optimizing conditions for light delivery for intracranial photodynamic therapy for high grade gliomas: a 3D model study of light dosimetry
SPIE Digital Library Proceedings
- 4 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10024, 37
Open AccessOptimizing conditions for light delivery for intracranial photodynamic therapy for high grade gliomas: a 3D model study of light dosimetry
SPIE Digital Library Proceedings
- 19 November 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (12) , 2292-2297
Endovascular Cerebral Venous Sinus Imaging with Optical Coherence Tomography
BACKGROUND AND PURPOSE: Imaging of the cerebral venous sinuses has evolved Substantially during the past 2 decades, and most recently intravascular sinus imaging with sonography has shed light on the pathophysiology of sinus thrombosis and intracranial hypertension. Optical coherence tomography is the highest resolution intravascular imaging technique available but has not been previously used in cerebral sinus imaging. The purpose of this study was to develop a preclinical animal model of endovascular optical coherence tomography cerebral venous sinus imaging and compare optical coherence tomography findings with histology. MATERIALS AND METHODS: Four consecutive Yorkshire swine were selected. The superior sagittal sinus was first catheterized with a microwire, and the optical coherence tomography catheter was delivered via a monorail technique into the sinus. Luminal blood was cleared with a single arterial injection. After structural and Doppler optical coherence tomography imaging, a craniotomy was performed and the sinus and adjacent dura/veins were resected. Bland-Altman analysis was performed to compare optical coherence tomography and histology. RESULTS: Technically successful optical coherence tomography images were obtained in 3 of 4 swine. The luminal environment and visualization of dural arteries and draining cortical veins were characterized. The average maximum diameters of the sinus, dural arteries, and cortical veins were 3.14 mm, 135 µm, and 260 µm, respectively. Bland-Altman analysis demonstrated good agreement between histology and optical coherence tomography images. CONCLUSIONS: Endovascular optical coherence tomography imaging was feasible in this preclinical animal study. Adoption of this imaging technique in the human cerebral venous sinus could aid in the diagnosis, treatment, and understanding of the pathophysiology of various diseases of the sinus. Human safety and feasibility studies are needed.
- 19 November 2020
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 41 (12) , 2292-2297
Endovascular Cerebral Venous Sinus Imaging with Optical Coherence Tomography
BACKGROUND AND PURPOSE: Imaging of the cerebral venous sinuses has evolved Substantially during the past 2 decades, and most recently intravascular sinus imaging with sonography has shed light on the pathophysiology of sinus thrombosis and intracranial hypertension. Optical coherence tomography is the highest resolution intravascular imaging technique available but has not been previously used in cerebral sinus imaging. The purpose of this study was to develop a preclinical animal model of endovascular optical coherence tomography cerebral venous sinus imaging and compare optical coherence tomography findings with histology. MATERIALS AND METHODS: Four consecutive Yorkshire swine were selected. The superior sagittal sinus was first catheterized with a microwire, and the optical coherence tomography catheter was delivered via a monorail technique into the sinus. Luminal blood was cleared with a single arterial injection. After structural and Doppler optical coherence tomography imaging, a craniotomy was performed and the sinus and adjacent dura/veins were resected. Bland-Altman analysis was performed to compare optical coherence tomography and histology. RESULTS: Technically successful optical coherence tomography images were obtained in 3 of 4 swine. The luminal environment and visualization of dural arteries and draining cortical veins were characterized. The average maximum diameters of the sinus, dural arteries, and cortical veins were 3.14 mm, 135 µm, and 260 µm, respectively. Bland-Altman analysis demonstrated good agreement between histology and optical coherence tomography images. CONCLUSIONS: Endovascular optical coherence tomography imaging was feasible in this preclinical animal study. Adoption of this imaging technique in the human cerebral venous sinus could aid in the diagnosis, treatment, and understanding of the pathophysiology of various diseases of the sinus. Human safety and feasibility studies are needed.
- 17 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11225, 21
Localization and spatially anchoring objects of an augmented reality headset using an onboard fisheye lens
The development of improved Augmented Reality (AR) Head-Mounted Devices (HMDs) have led to increasing use cases for AR applications. In the case of surgery, an HMD can be used as an assistive tool to help surgeons operate. With a triplanar surgical navigation system as an industry standard, the use of an HMD can improve the surgeon’s comfort, and overall experience. An HMD can offer the surgeon a consistent flow of information in front of their eyes with medically relevant images, such as craniospinal computed tomography (CT) data that can be displayed as they operate. This paper aims to bring an HMD-based overlay framework that can be used in the operating room. With a combination of Android Studio, OpenCV, and OpenGL, an inside-out localization method with Aruco Markers is demonstrated. The framework estimates the head pose of the user and subsequently renders a patient specific CT scan that will be spatially anchored to the real world. The CT reconstruction can then be virtually superimposed onto the physical patient. The HMD’s (ODG R9) fisheye lens will also be used to enhance and enable a larger field of view for better object detection. This paper also introduces a “focus mode” that improves the localization accuracy. The framework will be evaluated in each of the 3-axes for translational and rotational movement error. It will be evaluated on the detection accuracy of different numbers of markers and at different distances. It will also be evaluated using an ultra-high definition (UHD) camera.
- 17 February 2020
- Published by SPIE-Intl Soc Optical Eng
- Vol. 11225, 21
Localization and spatially anchoring objects of an augmented reality headset using an onboard fisheye lens
The development of improved Augmented Reality (AR) Head-Mounted Devices (HMDs) have led to increasing use cases for AR applications. In the case of surgery, an HMD can be used as an assistive tool to help surgeons operate. With a triplanar surgical navigation system as an industry standard, the use of an HMD can improve the surgeon’s comfort, and overall experience. An HMD can offer the surgeon a consistent flow of information in front of their eyes with medically relevant images, such as craniospinal computed tomography (CT) data that can be displayed as they operate. This paper aims to bring an HMD-based overlay framework that can be used in the operating room. With a combination of Android Studio, OpenCV, and OpenGL, an inside-out localization method with Aruco Markers is demonstrated. The framework estimates the head pose of the user and subsequently renders a patient specific CT scan that will be spatially anchored to the real world. The CT reconstruction can then be virtually superimposed onto the physical patient. The HMD’s (ODG R9) fisheye lens will also be used to enhance and enable a larger field of view for better object detection. This paper also introduces a “focus mode” that improves the localization accuracy. The framework will be evaluated in each of the 3-axes for translational and rotational movement error. It will be evaluated on the detection accuracy of different numbers of markers and at different distances. It will also be evaluated using an ultra-high definition (UHD) camera.
- 19 April 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 100500D-100500D-1
The characterization of neural tissue ablation rate and corresponding heat affected zone of a 2 micron Tm3+ doped fiber laser (Conference Presentation)
- 19 April 2017
- Published by SPIE-Intl Soc Optical Eng
- p. 100500D-100500D-1
The characterization of neural tissue ablation rate and corresponding heat affected zone of a 2 micron Tm3+ doped fiber laser (Conference Presentation)
- 10 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9305, 93050Q-93050Q-5
Evaluation of hemodynamics changes during interventional stent placement using Doppler optical coherence tomography
- 10 March 2015
- Published by SPIE-Intl Soc Optical Eng
- Vol. 9305, 93050Q-93050Q-5
Evaluation of hemodynamics changes during interventional stent placement using Doppler optical coherence tomography