Gökhan Canbolat
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Gökhan Canbolat has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Murat Koru
Department of Mechanical Engineering, Isparta University of Applied Sciences, Isparta, Türkiye
4 shared publicationsOguz Karahan
Department of Cardiovascular Surgery, Alanya Alaaddin Keykubat University, Antalya, Türkiye
3 shared publicationsFatih Darıcık
Alanya Alaaddin Keykubat University
2 shared publications- Murat Koru
Department of Mechanical Engineering, Technology Faculty, Isparta University of Applied Science, Isparta, Turkey
2 shared publications Mustafa Etli
Department of Cardiovascular Surgery, Alanya Alaaddin Keykubat University, Antalya, Turkey
2 shared publications- Alperen Yildizeli
Department of Mechanical Engineering, Istanbul Technical University 1 , Gumussuyu, Istanbul 34437
1 shared publication
Latest Publications
- 11 September 2026
- Published by Springer Nature in Sādhanā
- Vol. 51 (4) , 298
Experimental and numerical investigation of patient-specific hemodynamics in the thoracic aorta using the CFD method with Newtonian blood flow assumption
- 11 September 2026
- Published by Springer Nature in Sādhanā
- Vol. 51 (4) , 298
Experimental and numerical investigation of patient-specific hemodynamics in the thoracic aorta using the CFD method with Newtonian blood flow assumption
- Open Access
- 16 July 2026
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 85
CFD-driven optimization for thermo-electrical performance evaluation of a PV module considering the impact of heat sink on electrical model parameters
- 16 July 2026
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 85
Open AccessCFD-driven optimization for thermo-electrical performance evaluation of a PV module considering the impact of heat sink on electrical model parameters
- Open Access
- 7 June 2026
- Published by Elsevier in Journal of Engineering Research
- Vol. 14 (3) , 3990-4002
Numerical investigation of thermal and hydraulic performance of wavy fin heat sinks for longitudinal flow-wise design using CFD
- 7 June 2026
- Published by Elsevier in Journal of Engineering Research
- Vol. 14 (3) , 3990-4002
Open AccessNumerical investigation of thermal and hydraulic performance of wavy fin heat sinks for longitudinal flow-wise design using CFD
- Open Access
- 1 June 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (12) , 125512
Thermal performance evaluation of air and argon-filled double-glazing units: a comparative study via experimental testing and CFD modeling
Thermal comfort conditions in buildings can be achieved by properly insulating wall and window surfaces. Various studies in the literature have been performed to increase thermal comfort via insulation. The choice of proper glass is important in the design of windows, and one of the methods is double glazing, which is widely used nowadays. In double glazing, the layer of air between the glasses acts as a natural insulator, increasing the thermal resistance and improving its thermal performance. In this study, the thermal conductivity ( k ) of the glass used in the studies is taken directly from the standardized tables, and calculations and analysis are performed with these values. The thermal conductivity values of the glass samples were measured in laboratory for the location of the Isparta Province of Türkiye. Additionally, computational fluid dynamics analyses were performed on the glass samples, and the k -values were obtained numerically. The study investigates the effect of different gas layer thicknesses (12, 16, 19, and 20 mm) for dry air and argon. To study heat transfer, the glass thicknesses in double-glazed systems are specified as 4 mm and 8 mm, respectively. The k values were measured experimentally, and the numerical values were compared in study. The results showed that the experimental results are in good agreement with the numerical results. It is concluded that the optimum air and argon layer thickness for the Isparta province of Türkiye is 4 × 19 × 8 mm, and argon showed better results when the air and argon were compared.
- 1 June 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8 (12) , 125512
Open AccessThermal performance evaluation of air and argon-filled double-glazing units: a comparative study via experimental testing and CFD modeling
Thermal comfort conditions in buildings can be achieved by properly insulating wall and window surfaces. Various studies in the literature have been performed to increase thermal comfort via insulation. The choice of proper glass is important in the design of windows, and one of the methods is double glazing, which is widely used nowadays. In double glazing, the layer of air between the glasses acts as a natural insulator, increasing the thermal resistance and improving its thermal performance. In this study, the thermal conductivity ( k ) of the glass used in the studies is taken directly from the standardized tables, and calculations and analysis are performed with these values. The thermal conductivity values of the glass samples were measured in laboratory for the location of the Isparta Province of Türkiye. Additionally, computational fluid dynamics analyses were performed on the glass samples, and the k -values were obtained numerically. The study investigates the effect of different gas layer thicknesses (12, 16, 19, and 20 mm) for dry air and argon. To study heat transfer, the glass thicknesses in double-glazed systems are specified as 4 mm and 8 mm, respectively. The k values were measured experimentally, and the numerical values were compared in study. The results showed that the experimental results are in good agreement with the numerical results. It is concluded that the optimum air and argon layer thickness for the Isparta province of Türkiye is 4 × 19 × 8 mm, and argon showed better results when the air and argon were compared.
- Open Access
- 27 March 2026
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (19) , 21743-21760
Numerical and Theoretical Investigation of Thermal Performance in Double Pipe Heat Exchanger Using Nanofluids with Integrated CFD and ANN Methods
Recent research has focused significantly on the rising energy demand and advancements in heat exchangers, which are effective in heat transfer. This study examines the counter-flow Double Pipe Heat Exchanger (DPHE) under various flow, geometric, and thermal conditions using water-based nanofluids via Computational Fluid Dynamics (CFD). The objective of this research is to investigate the heat transfer performance in DPHEs, employing the effectiveness-NTU method for theoretical validation. Additionally, this study incorporates widely used water-based nanofluids with Al 2 O 3 , CuO, and hexagonal Boron Nitride (h-BN) nanoparticles at varying volume fractions to improve heat transfer. Several cases are designed to assess and compare thermal performance in heat exchangers using CFD. An Artificial Neural Network (ANN) model is developed in Python, integrating MATLAB to estimate thermal performance using the Overall Heat Transfer Coefficient ( U ). The findings revealed that h-BN nanofluids demonstrated outstanding heat transfer performance in different nanoparticles used in this study. The h-BN showed superior thermal performance compared to water and the other water-based Al 2 O 3 and CuO nanofluids. Comparisons with theoretical calculations validated the precision of the CFD simulation outcomes. Under the same conditions, it was observed that Al 2 O 3 increased U values by up to 20%, CuO by up to 15%, and h-BN by up to two times compared to water samples. The effectiveness method is in good agreement with CFD results. The constructed ANN model predicts heat transfer performance with an accuracy of 98.3% when compared with numerical and theoretical results.
- 27 March 2026
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (19) , 21743-21760
Open AccessNumerical and Theoretical Investigation of Thermal Performance in Double Pipe Heat Exchanger Using Nanofluids with Integrated CFD and ANN Methods
Recent research has focused significantly on the rising energy demand and advancements in heat exchangers, which are effective in heat transfer. This study examines the counter-flow Double Pipe Heat Exchanger (DPHE) under various flow, geometric, and thermal conditions using water-based nanofluids via Computational Fluid Dynamics (CFD). The objective of this research is to investigate the heat transfer performance in DPHEs, employing the effectiveness-NTU method for theoretical validation. Additionally, this study incorporates widely used water-based nanofluids with Al 2 O 3 , CuO, and hexagonal Boron Nitride (h-BN) nanoparticles at varying volume fractions to improve heat transfer. Several cases are designed to assess and compare thermal performance in heat exchangers using CFD. An Artificial Neural Network (ANN) model is developed in Python, integrating MATLAB to estimate thermal performance using the Overall Heat Transfer Coefficient ( U ). The findings revealed that h-BN nanofluids demonstrated outstanding heat transfer performance in different nanoparticles used in this study. The h-BN showed superior thermal performance compared to water and the other water-based Al 2 O 3 and CuO nanofluids. Comparisons with theoretical calculations validated the precision of the CFD simulation outcomes. Under the same conditions, it was observed that Al 2 O 3 increased U values by up to 20%, CuO by up to 15%, and h-BN by up to two times compared to water samples. The effectiveness method is in good agreement with CFD results. The constructed ANN model predicts heat transfer performance with an accuracy of 98.3% when compared with numerical and theoretical results.
- Open Access
- 4 June 2025
- Published by Springer Nature in Research Square
An Experimental Validation Study on Vascular Flow in Thoracic Aorta and Comparison by Computational Fluid Dynamics (CFD) for Newtonian Blood Flow
Numerical studies on aortic flows are highly performed by researchers. Computational Fluid Dynamics (CFD) is one of the methods to guide the blood flow in aortic structures. Multidisciplinary studies are conducted to assess vascular flow in terms of engineering and medicine with a common perspective. In this study, blood flow in the aorta is investigated by MR (Magnetic Resonance) or CT (Computed Tomography) angio images obtained retrospectively from a real and healthy individual, segmented with the support of the surgical team to create 3D models. The segmented 3D aortic model is produced by additive manufacturing. A mixture of glycerin and pure water is prepared for blood under Newtonian blood flow conditions. Viscosity and density are measured in the laboratory in accordance with body temperature. The flow rate and pressure variations at the aortic inlet, descending aorta, and the three main branches of the aorta were obtained by experimental and numerical methods using flow meters and pressure transmitters. The studies were also supported by numerical analyses, and compared with the numerical analyses. The relative error between experimental and numerical results does not exceed 10%, except for some turbulent models used in this study, for the flow rate and pressure along the cardiac cycle specified in this study. Laminar and SST k-w turbulent models are in good agreement with experimental studies. Experimental and numerical studies have provided the opportunity to examine different parameters of the aorta and aortic diseases.
- 4 June 2025
- Published by Springer Nature in Research Square
Open AccessAn Experimental Validation Study on Vascular Flow in Thoracic Aorta and Comparison by Computational Fluid Dynamics (CFD) for Newtonian Blood Flow
Numerical studies on aortic flows are highly performed by researchers. Computational Fluid Dynamics (CFD) is one of the methods to guide the blood flow in aortic structures. Multidisciplinary studies are conducted to assess vascular flow in terms of engineering and medicine with a common perspective. In this study, blood flow in the aorta is investigated by MR (Magnetic Resonance) or CT (Computed Tomography) angio images obtained retrospectively from a real and healthy individual, segmented with the support of the surgical team to create 3D models. The segmented 3D aortic model is produced by additive manufacturing. A mixture of glycerin and pure water is prepared for blood under Newtonian blood flow conditions. Viscosity and density are measured in the laboratory in accordance with body temperature. The flow rate and pressure variations at the aortic inlet, descending aorta, and the three main branches of the aorta were obtained by experimental and numerical methods using flow meters and pressure transmitters. The studies were also supported by numerical analyses, and compared with the numerical analyses. The relative error between experimental and numerical results does not exceed 10%, except for some turbulent models used in this study, for the flow rate and pressure along the cardiac cycle specified in this study. Laminar and SST k-w turbulent models are in good agreement with experimental studies. Experimental and numerical studies have provided the opportunity to examine different parameters of the aorta and aortic diseases.
- Open Access
- 5 March 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (11) , 14787-14802
Investigation of Rupture Risk of Thoracic Aortic Aneurysms via Fluid–Structure Interaction and Artificial Intelligence Method
Patient-specific studies on vascular flows have significantly increased for hemodynamics due to the need for different observation techniques in clinical practice. In this study, we investigate aortic aneurysms in terms of deformation, stress, and rupture risk. The effect of Ascending Aortic Diameter (AAD) was investigated in different aortic arches (19.81 mm, 42.94 mm, and 48.01 mm) via Computational Fluid Dynamics (CFD), Two-way coupling Fluid–Structure Interactions (FSI) and deep learning. The non-newtonian Carreau viscosity model was utilized with patient-specific velocity waveform. Deformations, Wall Shear Stresses (WSSs), von Mises stress, and rupture risk were presented by safety factors. Results show that the WSS distribution is distinctly higher in rigid cases than the elastic cases. Although WSS values rise with the increase in AAD, aneurysm regions indicate low WSS values in both rigid and elastic artery solutions. For the given AADs, the deformations are 2.75 mm, 6. 82 mm, and 8.48 mm and Equivalent von Mises stresses are 0.16 MPa, 0.46 MPa, and 0.53 MPa. When the rupture risk was evaluated for the arteries, the results showed that the aneurysm with AAD of 48.01 mm poses a risk up to three times more than AAD of 19.81 mm. In addition, an Artificial neural network (ANN) method was developed to predict the rupture risk with a 98.6% accurate prediction by numerical data. As a result, FSI could indicate more accurately the level of rupture risk than the rigid artery assumptions to guide the clinical assessments and deep learning methods could decrease the computational costs according to CFD and FSI.
- 5 March 2024
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (11) , 14787-14802
Open AccessInvestigation of Rupture Risk of Thoracic Aortic Aneurysms via Fluid–Structure Interaction and Artificial Intelligence Method
Patient-specific studies on vascular flows have significantly increased for hemodynamics due to the need for different observation techniques in clinical practice. In this study, we investigate aortic aneurysms in terms of deformation, stress, and rupture risk. The effect of Ascending Aortic Diameter (AAD) was investigated in different aortic arches (19.81 mm, 42.94 mm, and 48.01 mm) via Computational Fluid Dynamics (CFD), Two-way coupling Fluid–Structure Interactions (FSI) and deep learning. The non-newtonian Carreau viscosity model was utilized with patient-specific velocity waveform. Deformations, Wall Shear Stresses (WSSs), von Mises stress, and rupture risk were presented by safety factors. Results show that the WSS distribution is distinctly higher in rigid cases than the elastic cases. Although WSS values rise with the increase in AAD, aneurysm regions indicate low WSS values in both rigid and elastic artery solutions. For the given AADs, the deformations are 2.75 mm, 6. 82 mm, and 8.48 mm and Equivalent von Mises stresses are 0.16 MPa, 0.46 MPa, and 0.53 MPa. When the rupture risk was evaluated for the arteries, the results showed that the aneurysm with AAD of 48.01 mm poses a risk up to three times more than AAD of 19.81 mm. In addition, an Artificial neural network (ANN) method was developed to predict the rupture risk with a 98.6% accurate prediction by numerical data. As a result, FSI could indicate more accurately the level of rupture risk than the rigid artery assumptions to guide the clinical assessments and deep learning methods could decrease the computational costs according to CFD and FSI.
- 27 December 2023
- Published by ALKU Fen Bilimleri Dergisi, Alanya Alaaddin Keykubat University in ALKÜ Fen Bilimleri Dergisi
- Vol. 5 (3) , 118-130
A Numerical Study on Cross Flow Heat Exchanger with Different Reynolds (Re) Numbers
Heat exchangers are highly popular in engineering and industrial applications. Numerical studies on heat exchangers to investigate the performance of heat transfer have been carried out widely by Computational Fluid Dynamics (CFD) in recent years. In this study, a circular pipe with hot water in cross flow is investigated in different Reynolds (Re) numbers. Flow is turbulent flow and the Re number varies from 3165 to 4643 in the circular pipe. The air is at a temperature of 303 K and the water is at 333 K. Variation of flow characteristics and thermal performance is observed according to an increase in Re numbers such as Wall Shear Stress (WSS), Skin Friction Coefficient (Cf), Nusselt Number (Nu), heat transfer coefficient (h) and surface temperature of the circular pipe. Results show that there are no significant changes for the WSS and Cf values in the specified range of the Re number. However, when the thermal performance is evaluated, the temperature of the surface of the circular pipe, heat transfer coefficient, and Nu number values are increased by an increase in the Re number. Here, the increase is approximately 2% for the specified range of Re number, and it is shown that it can be increased by the flow conditions. The maximum Nu number is 4482.37 at the Re number of 4643. As a result, the Re number is highly effective in controlling the heat transfer performance of a heat exchanger
- 27 December 2023
- Published by ALKU Fen Bilimleri Dergisi, Alanya Alaaddin Keykubat University in ALKÜ Fen Bilimleri Dergisi
- Vol. 5 (3) , 118-130
A Numerical Study on Cross Flow Heat Exchanger with Different Reynolds (Re) Numbers
Heat exchangers are highly popular in engineering and industrial applications. Numerical studies on heat exchangers to investigate the performance of heat transfer have been carried out widely by Computational Fluid Dynamics (CFD) in recent years. In this study, a circular pipe with hot water in cross flow is investigated in different Reynolds (Re) numbers. Flow is turbulent flow and the Re number varies from 3165 to 4643 in the circular pipe. The air is at a temperature of 303 K and the water is at 333 K. Variation of flow characteristics and thermal performance is observed according to an increase in Re numbers such as Wall Shear Stress (WSS), Skin Friction Coefficient (Cf), Nusselt Number (Nu), heat transfer coefficient (h) and surface temperature of the circular pipe. Results show that there are no significant changes for the WSS and Cf values in the specified range of the Re number. However, when the thermal performance is evaluated, the temperature of the surface of the circular pipe, heat transfer coefficient, and Nu number values are increased by an increase in the Re number. Here, the increase is approximately 2% for the specified range of Re number, and it is shown that it can be increased by the flow conditions. The maximum Nu number is 4482.37 at the Re number of 4643. As a result, the Re number is highly effective in controlling the heat transfer performance of a heat exchanger
- Open Access
- 25 December 2023
- Published by Cukurova Universitesi Muhendislik-Mimarlik Fakultesi Dergisi in Çukurova Üniversitesi Mühendislik Fakültesi Dergisi
- Vol. 38 (4) , 1049-1060
Farklı Isı ve Basınç Koşulları Altında Düz Bir Boru İçin Tek Yönlü Akışkan-Yapı Etkileşimleri Analizi
Numerical studies on stress, deformation, and damages due to fluid flow have been highly carried out using Fluid-Structure Interaction (FSI) in recent years. FSI is highly efficient in investigating a solid domain deformed by the fluid flow. In this study, a one-way fluid-structure interaction study is performed by a straight pipe under different pressure and thermal conditions. Here, the thermophysical properties of the fluid and mechanical properties of the solid domain can be subjected to change during fluid flow. An aluminum straight pipe with a 1 mm wall thickness is operated under 1 Bar, 5 Bar, and 10 Bar with three different surface temperatures -10ºC, 20ºC, and 50ºC. This study aims to investigate the structural variation of aluminum by the temperature and pressure change of operating fluid in the pipe. Variation of thermophysical properties of fluid by heated pipe surface is integrated into the numerical analysis by generated functions. Numerical analysis showed that the variation of temperature in operating fluid highly affects the fluid characteristic and the structural response of the solid domain by different temperatures. An increase in the operating pressure caused maximum deformation to approximately %100 from 1 Bar to 5 Bar, and approximately %120 from 1 Bar to 10 Bar for the adiabatic process as expected but in the heating conditions stress is nearly three times higher than cooling conditions. As a result, one-way FSI solutions are highly effective in investigating the deformed solid domain as a result of flow, thermal, and operating conditions.
- 25 December 2023
- Published by Cukurova Universitesi Muhendislik-Mimarlik Fakultesi Dergisi in Çukurova Üniversitesi Mühendislik Fakültesi Dergisi
- Vol. 38 (4) , 1049-1060
Open AccessFarklı Isı ve Basınç Koşulları Altında Düz Bir Boru İçin Tek Yönlü Akışkan-Yapı Etkileşimleri Analizi
Numerical studies on stress, deformation, and damages due to fluid flow have been highly carried out using Fluid-Structure Interaction (FSI) in recent years. FSI is highly efficient in investigating a solid domain deformed by the fluid flow. In this study, a one-way fluid-structure interaction study is performed by a straight pipe under different pressure and thermal conditions. Here, the thermophysical properties of the fluid and mechanical properties of the solid domain can be subjected to change during fluid flow. An aluminum straight pipe with a 1 mm wall thickness is operated under 1 Bar, 5 Bar, and 10 Bar with three different surface temperatures -10ºC, 20ºC, and 50ºC. This study aims to investigate the structural variation of aluminum by the temperature and pressure change of operating fluid in the pipe. Variation of thermophysical properties of fluid by heated pipe surface is integrated into the numerical analysis by generated functions. Numerical analysis showed that the variation of temperature in operating fluid highly affects the fluid characteristic and the structural response of the solid domain by different temperatures. An increase in the operating pressure caused maximum deformation to approximately %100 from 1 Bar to 5 Bar, and approximately %120 from 1 Bar to 10 Bar for the adiabatic process as expected but in the heating conditions stress is nearly three times higher than cooling conditions. As a result, one-way FSI solutions are highly effective in investigating the deformed solid domain as a result of flow, thermal, and operating conditions.