Yi-Wei Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yi-Wei Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Yuan-Yih Hsu
Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
4 shared publications - Cheng-Han Chuang
Department of Electrical Engineering, National Taiwan University, EE Building 2, No. 1, Sec. 4, Roosevelt Rd., Taipei City 106, Taiwan
1 shared publication Cheng‐Han Chuang
National Taiwan University Taipei Taiwan, Republic of China
1 shared publication- Xuecheng Xu
Zhejiang University, Hangzhou, China
1 shared publication You‐Ning Xu
Taiwan Power Company Taipei Taiwan, Republic of China
1 shared publication- Yu-Chen Huang
Department of Dermatology, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan
1 shared publication
Latest Publications
- Open Access
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 12, 858-869
Torsional Vibration Mitigation in Wind Turbines Using BESS in a Microgrid
The paper introduces a damping control scheme utilizing a battery energy storage system (BESS) to mitigate torsional vibrations for wind turbine generators (WTGs) in a microgrid. As WTGs are tasked with providing frequency regulation in response to the challenges of low system inertia caused by renewable energy integration, the WTG ancillary frequency controllers can induce undesired torsional vibrations in the drivetrain system. Moreover, WTG torsional vibrations can also be electromechanically excited by grid voltages or mechanically induced by changes in wind speed. To address undesired WTG torsional vibrations, this study proposes a hybrid control scheme that combines linear controller and sliding mode controller (SMC) to mitigate torsional vibrations in WTGs using a BESS. The contribution of the paper lies in extending BESS applications and presenting an efficient control scheme for mitigating WTG torsional vibrations when the microgrid is subjected to unplanned islanding and wind speed variations. Time-domain simulations are conducted to validate the analysis and demonstrate the effectiveness of the proposed scheme.
- 5 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Access Journal of Power and Energy
- Vol. 12, 858-869
Open AccessTorsional Vibration Mitigation in Wind Turbines Using BESS in a Microgrid
The paper introduces a damping control scheme utilizing a battery energy storage system (BESS) to mitigate torsional vibrations for wind turbine generators (WTGs) in a microgrid. As WTGs are tasked with providing frequency regulation in response to the challenges of low system inertia caused by renewable energy integration, the WTG ancillary frequency controllers can induce undesired torsional vibrations in the drivetrain system. Moreover, WTG torsional vibrations can also be electromechanically excited by grid voltages or mechanically induced by changes in wind speed. To address undesired WTG torsional vibrations, this study proposes a hybrid control scheme that combines linear controller and sliding mode controller (SMC) to mitigate torsional vibrations in WTGs using a BESS. The contribution of the paper lies in extending BESS applications and presenting an efficient control scheme for mitigating WTG torsional vibrations when the microgrid is subjected to unplanned islanding and wind speed variations. Time-domain simulations are conducted to validate the analysis and demonstrate the effectiveness of the proposed scheme.
- Open Access
- 17 April 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 16 (8) , 1685-1698
A generalized piecewise linear time‐variable droop frequency controller with adaptive parameters for de‐loaded wind turbine generators
This paper proposes a generalized piecewise linear time‐variable droop frequency controller with a ramp‐up period for a de‐loaded wind turbine generator. The authors present an analytical model using a simplified system frequency response (SFR) to explain the need for a ramp‐up period under the conditions of variable wind speed. In order to achieve the highest frequency nadir under different operating conditions, the durations and peak value of the time‐variable droop function must be adapted in real time. This adaptation is achieved using an artificial neural network (ANN) based on current system variables such as wind speed, penetration, pitch angle, wind speed change, and outage capacity. Dynamic frequency responses for a power system subject to generator outages and wind speed changes are simulated using MATLAB/Simulink to demonstrate the effectiveness of the proposed droop controller. These results show that the frequency nadir can be improved by the proposed algorithm through adaption of the durations and peak value.
- 17 April 2022
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 16 (8) , 1685-1698
Open AccessA generalized piecewise linear time‐variable droop frequency controller with adaptive parameters for de‐loaded wind turbine generators
This paper proposes a generalized piecewise linear time‐variable droop frequency controller with a ramp‐up period for a de‐loaded wind turbine generator. The authors present an analytical model using a simplified system frequency response (SFR) to explain the need for a ramp‐up period under the conditions of variable wind speed. In order to achieve the highest frequency nadir under different operating conditions, the durations and peak value of the time‐variable droop function must be adapted in real time. This adaptation is achieved using an artificial neural network (ANN) based on current system variables such as wind speed, penetration, pitch angle, wind speed change, and outage capacity. Dynamic frequency responses for a power system subject to generator outages and wind speed changes are simulated using MATLAB/Simulink to demonstrate the effectiveness of the proposed droop controller. These results show that the frequency nadir can be improved by the proposed algorithm through adaption of the durations and peak value.
- Open Access
- 1 January 2022
- Published by National Library of Serbia in Thermal Science
- Vol. 26 (4 Part B) , 3359-3371
Thermal analysis on natural-convection coupled with radiative heat transfer in a saturated porous cavity
Porous foam is an ideal material for enhancing radiative heat transfer in numerous thermal equipment. The solid skeletons of porous foams can absorb/ release radiative energy and transfer convective energy with the surrounding fluid in the pores. In this paper, the conduction-convection-radiation coupling heat transfer in a porous cavity is investigated. A local thermal nonequilibrium model is used to represent the energy transport during the solid and fluid phases. The heat flux caused by thermal radiation is obtained by solving the radiation transfer equation. The thermal and fluid fields are studied to discern various parameters, including the Planck numbers Pl , the modified Rayleigh numbers Ra , and the interphase heat transfer coefficients H . Our study indicates the following: (1) the effect of radiation can be neglected when Pl > 20; (2) the modified Rayleigh numbers have little influence on the solid temperature when the radiative heat transfer is dominant and the convective heat transfer between the two phases is weak; and (3) the local thermal-equilibrium can be formed when H exhibits high values.
- 1 January 2022
- Published by National Library of Serbia in Thermal Science
- Vol. 26 (4 Part B) , 3359-3371
Open AccessThermal analysis on natural-convection coupled with radiative heat transfer in a saturated porous cavity
Porous foam is an ideal material for enhancing radiative heat transfer in numerous thermal equipment. The solid skeletons of porous foams can absorb/ release radiative energy and transfer convective energy with the surrounding fluid in the pores. In this paper, the conduction-convection-radiation coupling heat transfer in a porous cavity is investigated. A local thermal nonequilibrium model is used to represent the energy transport during the solid and fluid phases. The heat flux caused by thermal radiation is obtained by solving the radiation transfer equation. The thermal and fluid fields are studied to discern various parameters, including the Planck numbers Pl , the modified Rayleigh numbers Ra , and the interphase heat transfer coefficients H . Our study indicates the following: (1) the effect of radiation can be neglected when Pl > 20; (2) the modified Rayleigh numbers have little influence on the solid temperature when the radiative heat transfer is dominant and the convective heat transfer between the two phases is weak; and (3) the local thermal-equilibrium can be formed when H exhibits high values.
- Open Access
PSO Self-Tuning Power Controllers for Low Voltage Improvements of an Offshore Wind Farm in Taiwan
A de-loaded real power control strategy is proposed to decrease the real power output and increase the reactive power output of a grid-connected offshore wind farm in order to improve the voltage profile when the wind farm is subject to a grid fault. A simplified linear model of the wind farm is first derived and a fixed-gain proportional-integral (PI) real power controller is designed based on the pole-zero cancellation method. To improve the dynamic voltage response when the system is subject to a major disturbance such as a three-phase fault in the grid, a self-tuning controller based on particle swarm optimization (PSO) is proposed to adapt the PI controller gains based on the on-line measured system variables. Digital simulations using MATLAB/SIMULINK were performed on an offshore wind farm connected to the power grid in central Taiwan in order to validate the effectiveness of the proposed PSO controller. It is concluded from the simulation results that a better dynamic voltage response can be achieved by the proposed PSO self-tuning controller than the fixed-gain controller when the grid is subject to a three-phase fault. In addition, low voltage ride through (LVRT) requirements of the local utility can be met by the wind farm with the proposed power controller.
Open AccessPSO Self-Tuning Power Controllers for Low Voltage Improvements of an Offshore Wind Farm in Taiwan
A de-loaded real power control strategy is proposed to decrease the real power output and increase the reactive power output of a grid-connected offshore wind farm in order to improve the voltage profile when the wind farm is subject to a grid fault. A simplified linear model of the wind farm is first derived and a fixed-gain proportional-integral (PI) real power controller is designed based on the pole-zero cancellation method. To improve the dynamic voltage response when the system is subject to a major disturbance such as a three-phase fault in the grid, a self-tuning controller based on particle swarm optimization (PSO) is proposed to adapt the PI controller gains based on the on-line measured system variables. Digital simulations using MATLAB/SIMULINK were performed on an offshore wind farm connected to the power grid in central Taiwan in order to validate the effectiveness of the proposed PSO controller. It is concluded from the simulation results that a better dynamic voltage response can be achieved by the proposed PSO self-tuning controller than the fixed-gain controller when the grid is subject to a three-phase fault. In addition, low voltage ride through (LVRT) requirements of the local utility can be met by the wind farm with the proposed power controller.
- Open Access
Flexible Kinetic Energy Release Controllers for a Wind Farm in an Islanding System
To improve frequency nadir following a disturbance and avoid under-frequency load shedding, two types of flexible kinetic energy release controllers for the doubly fed induction generator (DFIG) are proposed. The basic idea is to release only a small amount of kinetic energy stored at the DFIG in the initial transient period (1–3 s after the disturbance). When the frequency dip exceeds a preset threshold, the amount of kinetic energy released is increased to improve the frequency nadir. To achieve the goal of flexible kinetic energy release, a deactivation function based integral controller is first presented. To further improve the dynamic frequency response under parameter uncertainties and external disturbances, a second flexible kinetic energy release controller is designed using a proportional-integral controller, with the gains being adapted in real-time with the particle swarm optimization algorithm. Based on the MATLAB/SIMULINK simulation results for a local power system, it is concluded that the frequency nadir can be maintained around the under-frequency load shedding threshold of 59.6 Hz using the proposed controllers.
Open AccessFlexible Kinetic Energy Release Controllers for a Wind Farm in an Islanding System
To improve frequency nadir following a disturbance and avoid under-frequency load shedding, two types of flexible kinetic energy release controllers for the doubly fed induction generator (DFIG) are proposed. The basic idea is to release only a small amount of kinetic energy stored at the DFIG in the initial transient period (1–3 s after the disturbance). When the frequency dip exceeds a preset threshold, the amount of kinetic energy released is increased to improve the frequency nadir. To achieve the goal of flexible kinetic energy release, a deactivation function based integral controller is first presented. To further improve the dynamic frequency response under parameter uncertainties and external disturbances, a second flexible kinetic energy release controller is designed using a proportional-integral controller, with the gains being adapted in real-time with the particle swarm optimization algorithm. Based on the MATLAB/SIMULINK simulation results for a local power system, it is concluded that the frequency nadir can be maintained around the under-frequency load shedding threshold of 59.6 Hz using the proposed controllers.