Lercan Aslan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lercan Aslan has a total of 105 co-authors. Here are the top co-authors by number of shared publications:
- Cemil Cihad Gedik
Department of Orthopaedics and Traumatology, Koç University School of Medicine, Istanbul, Türkiye
6 shared publications - Kadir Büyükdoğan
Department of Orthopedic Surgery, Güven Hospital, Ankara, Türkiye
6 shared publications - Soheil Ashkani-Esfahani
Foot & Ankle Research and Innovation Lab (FARIL), Department of Orthopaedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA
5 shared publications - Mehmet Ali Deveci
Department of Orthopaedics and Traumatology, Koç University, İstanbul, Türkiye
4 shared publications - Mehmet Demirhan
Koç Üniversitesi Tıp Fakültesi, Ortopedi ve Travmatoloji Ana Bilim Dalı, İstanbul
4 shared publications - Omer Subasi
Foot & Ankle Research and Innovation Laboratory, Department of Orthopaedic Surgery, Mass General Brigham, Harvard Medical School, Boston, MA, USA
4 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 11 (4)
The Influence of Screw Height Placement on Syndesmotic Malreduction: A Cadaveric Study
Background: Syndesmotic malreduction is a well-documented complication impacting ankle fracture outcomes. Although syndesmotic screw fixation remains the most common method for stabilization, optimal screw height placement has not been rigorously evaluated in terms of its impact on reduction accuracy. This cadaveric study aimed to assess the influence of screw height placement on syndesmotic alignment in a simulated pronation–external rotation (PER) ankle fracture model. Methods: Ten knee disarticulated cadaveric specimens underwent simulated PER injuries. Quad-cortical syndesmotic screws were incrementally placed at different levels at 0.6-cm intervals, ranging from 1.5 to 6.3 cm above the plafond. At each level, the syndesmosis was manually open reduced, stabilized, and imaged using computed tomography. Syndesmotic alignment was assessed using standard axial 2-D measurements and 3-D volumetric analysis. For each screw height placement, radiographic parameters were compared to the intact state. Results: Screw height placement significantly influenced syndesmotic alignment across all measured parameters. Fibular rotation and translation both varied significantly with screw level ( P < .01), as did anterior, mid, and posterior diastasis (all P < .01). Three-dimensional volumetric analysis also showed a significant difference between screw levels ( P < .01). A screw placed 2.7 cm above the tibial plafond resulted in alignment measurements closest to native across 2-D and 3-D measurements. With the numbers available, no correlation could be detected between surgeon variability, incisural morphology, and malreduction. Conclusion: This study suggests that screw height placement can influence the quality of syndesmotic reduction in a simulated PER ankle fracture model. A screw placed 2.7 cm above the tibial plafond most closely approximated native syndesmotic alignment and may minimize the risk of malreduction. Clinical Relevance: Given the reported incidence of syndesmotic malreduction and its association with worse outcomes, understanding whether screw height placement is a modifiable risk factor may inform intraoperative technique during syndesmotic fixation.
- 16 October 2026
- Published by SAGE Publications in Foot & Ankle Orthopaedics
- Vol. 11 (4)
Open AccessThe Influence of Screw Height Placement on Syndesmotic Malreduction: A Cadaveric Study
Background: Syndesmotic malreduction is a well-documented complication impacting ankle fracture outcomes. Although syndesmotic screw fixation remains the most common method for stabilization, optimal screw height placement has not been rigorously evaluated in terms of its impact on reduction accuracy. This cadaveric study aimed to assess the influence of screw height placement on syndesmotic alignment in a simulated pronation–external rotation (PER) ankle fracture model. Methods: Ten knee disarticulated cadaveric specimens underwent simulated PER injuries. Quad-cortical syndesmotic screws were incrementally placed at different levels at 0.6-cm intervals, ranging from 1.5 to 6.3 cm above the plafond. At each level, the syndesmosis was manually open reduced, stabilized, and imaged using computed tomography. Syndesmotic alignment was assessed using standard axial 2-D measurements and 3-D volumetric analysis. For each screw height placement, radiographic parameters were compared to the intact state. Results: Screw height placement significantly influenced syndesmotic alignment across all measured parameters. Fibular rotation and translation both varied significantly with screw level ( P < .01), as did anterior, mid, and posterior diastasis (all P < .01). Three-dimensional volumetric analysis also showed a significant difference between screw levels ( P < .01). A screw placed 2.7 cm above the tibial plafond resulted in alignment measurements closest to native across 2-D and 3-D measurements. With the numbers available, no correlation could be detected between surgeon variability, incisural morphology, and malreduction. Conclusion: This study suggests that screw height placement can influence the quality of syndesmotic reduction in a simulated PER ankle fracture model. A screw placed 2.7 cm above the tibial plafond most closely approximated native syndesmotic alignment and may minimize the risk of malreduction. Clinical Relevance: Given the reported incidence of syndesmotic malreduction and its association with worse outcomes, understanding whether screw height placement is a modifiable risk factor may inform intraoperative technique during syndesmotic fixation.
- 11 September 2026
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 60 (5)
Biomechanical Evaluation of Bio-inductive Implant Augmentation for ATFL and CFL Repair in Chronic Lateral Ankle Instability
Objective: This study aimed to compare the biomechanical properties of bio-inductive implant augmentation and suture repair for anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) repair in chronic lateral ankle instability. Methods: This controlled cadaveric biomechanical study included eight fresh-frozen human ankle specimens [median age of 76 years, Interquartile Range (IQR): 70.5–83]; 5 males and 3 females). Using a repeated-measures design, each specimen was tested under three conditions: intact ligaments, suture repair, and bio-inductive implant augmentation (Bio-Aug). Following intact testing, the order of the suture repair and bio-inductive augmentation conditions was randomized. Biomechanical testing consisted of a 500-cycle loading protocol. The primary outcome measures were construct stiffness, primary creep, cyclic loading survival, and load-to-failure. Results: All specimens in the intact and Bio-Aug groups completed the 500-cycle protocol, whereas only three of eight (37.5%) specimens in the suture repair group did so. Both primary and final stiffness were greatest in the intact and Bio-Aug groups and lowest in the suture repair group; however, no significant differences were observed among groups for either primary (Friedman χ.(2)=4.33, P =.11) or final stiffness (Friedman χ.(2)=3.25, P =.20). Primary creep differed significantly across conditions (P=.006). Compared with the intact group, both the suture repair group (4.54% vs. 0.50%, P =.04) and the Bio-Aug group (1.60% vs. 0.50%, P =.02) demonstrated greater creep, although Bio-Aug values were substantially closer to those of the intact ligaments. The median load-to-failure of the Bio-Aug constructs was 330 N (IQR, 300–360 N). Conclusion: Bio-inductive implant augmentation restored construct stiffness comparable to that of the intact ligament complex while demonstrating substantially lower creep than suture repair alone in this time-zero cadaveric model. These findings suggest that bio-inductive augmentation may provide improved early mechanical support while preserving biomechanical characteristics closer to native ligament tissue. Further in vivo and clinical studies are required to determine whether these biomechanical advantages translate into improved clinical outcomes and rehabilitation protocols. Cite this article as: Taseh A, Aslan L, Kord MHC, et al. Biomechanical Evaluation of Bio-inductive Implant Augmentation for ATFL and CFL Repair in Chronic Lateral Ankle Instability. Acta Orthop Traumatol Turc., 2026; 60(5), 0953, doi: 10.5152/j.aott.2026.26953.
- 11 September 2026
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 60 (5)
Biomechanical Evaluation of Bio-inductive Implant Augmentation for ATFL and CFL Repair in Chronic Lateral Ankle Instability
Objective: This study aimed to compare the biomechanical properties of bio-inductive implant augmentation and suture repair for anterior talofibular ligament (ATFL) and calcaneofibular ligament (CFL) repair in chronic lateral ankle instability. Methods: This controlled cadaveric biomechanical study included eight fresh-frozen human ankle specimens [median age of 76 years, Interquartile Range (IQR): 70.5–83]; 5 males and 3 females). Using a repeated-measures design, each specimen was tested under three conditions: intact ligaments, suture repair, and bio-inductive implant augmentation (Bio-Aug). Following intact testing, the order of the suture repair and bio-inductive augmentation conditions was randomized. Biomechanical testing consisted of a 500-cycle loading protocol. The primary outcome measures were construct stiffness, primary creep, cyclic loading survival, and load-to-failure. Results: All specimens in the intact and Bio-Aug groups completed the 500-cycle protocol, whereas only three of eight (37.5%) specimens in the suture repair group did so. Both primary and final stiffness were greatest in the intact and Bio-Aug groups and lowest in the suture repair group; however, no significant differences were observed among groups for either primary (Friedman χ.(2)=4.33, P =.11) or final stiffness (Friedman χ.(2)=3.25, P =.20). Primary creep differed significantly across conditions (P=.006). Compared with the intact group, both the suture repair group (4.54% vs. 0.50%, P =.04) and the Bio-Aug group (1.60% vs. 0.50%, P =.02) demonstrated greater creep, although Bio-Aug values were substantially closer to those of the intact ligaments. The median load-to-failure of the Bio-Aug constructs was 330 N (IQR, 300–360 N). Conclusion: Bio-inductive implant augmentation restored construct stiffness comparable to that of the intact ligament complex while demonstrating substantially lower creep than suture repair alone in this time-zero cadaveric model. These findings suggest that bio-inductive augmentation may provide improved early mechanical support while preserving biomechanical characteristics closer to native ligament tissue. Further in vivo and clinical studies are required to determine whether these biomechanical advantages translate into improved clinical outcomes and rehabilitation protocols. Cite this article as: Taseh A, Aslan L, Kord MHC, et al. Biomechanical Evaluation of Bio-inductive Implant Augmentation for ATFL and CFL Repair in Chronic Lateral Ankle Instability. Acta Orthop Traumatol Turc., 2026; 60(5), 0953, doi: 10.5152/j.aott.2026.26953.
- 27 February 2026
- Published by Bilimsel Tip Publishing House in TOTBİD Derleme Dergisi
- Vol. 25 (2) , 122-129
Ayak ve ayak bileği çevresi tendon biyomekaniği
- 27 February 2026
- Published by Bilimsel Tip Publishing House in TOTBİD Derleme Dergisi
- Vol. 25 (2) , 122-129
Ayak ve ayak bileği çevresi tendon biyomekaniği
- Open Access
- 31 December 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (6) , 337-339
AOTT special issue Editorial
Cite this article as: Ashkani-Esfahani S, Aslan L. AOTT special issue Editorial. Acta Orthop Traumatol Turc., 2025;59(6):337-339.
- 31 December 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (6) , 337-339
Open AccessAOTT special issue Editorial
Cite this article as: Ashkani-Esfahani S, Aslan L. AOTT special issue Editorial. Acta Orthop Traumatol Turc., 2025;59(6):337-339.
- Open Access
- 31 December 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (6) , 361-367
In silico assessment of talus osteochondral lesion size and location on biomechanical load distribution using tilted talar dome planes
Objective: This study aimed to computationally evaluate the effects of lesions of varying sizes and locations on stress distribution and ankle stiffness across the nine-zone grid of the talar dome in three different ankle positions. Methods: An adult ankle geometry was modeled with 1 mm of cartilage on both sides of the tibiotalar contact. Lesions with diameters of 4.5, 6.4, and 9 mm were created on the talar dome at each grid partition, ranging from section 1 (anteromedial) to 9 (posterolateral). Thekey innovation of the study was the use of tilted talar planes to account for the dome’s curvature, enabling more accurate lesion model ing and biomechanical analysis. Percent changes in osteochondral von Mises stress distribution and ankle stiffness parameters were investigated using finite element analysis. Based on the designated design parameters, 81 different cases were modeled and simulated. Results: Zones 7 (posteromedial, −33.2% change in stiffness for a 9 mm defect), 3 (anterolateral, −24.2% change in stiffness for a 9 mmdefect), and 8 (mid-posterior, −48.8% change in stiffness for a 9 mm defect) were found to be the most critical zones, showing evidence of decreased ankle stiffness in neutral, dorsiflexion, and plantarflexion positions, respectively. Zone 9 (posterolateral; neutral −4.7%, dorsi f lexion 5.4%, plantarflexion 0.17% stiffness change for a 9 mm defect) was found to be the least critical zone in terms of biomechanical stiffness. Conclusion: From a clinical standpoint, since lesions in zones 8, 7, and 3 significantly impact joint biomechanics compared to other zones, more aggressive cartilage restoration or augmentation could be required while lesions in less problematic zones like zone 9 can be treated withmicrofracture surgery. Cite this article as: Aslan L, Subasi O, Karaismailoglu B, et al. In silico assessment of talus osteochondral lesion size and location on biomechanical load distribution using tilted talar dome planes. Acta Orthop Traumatol Turc., 2025;59(6):361-367.
- 31 December 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (6) , 361-367
Open AccessIn silico assessment of talus osteochondral lesion size and location on biomechanical load distribution using tilted talar dome planes
Objective: This study aimed to computationally evaluate the effects of lesions of varying sizes and locations on stress distribution and ankle stiffness across the nine-zone grid of the talar dome in three different ankle positions. Methods: An adult ankle geometry was modeled with 1 mm of cartilage on both sides of the tibiotalar contact. Lesions with diameters of 4.5, 6.4, and 9 mm were created on the talar dome at each grid partition, ranging from section 1 (anteromedial) to 9 (posterolateral). Thekey innovation of the study was the use of tilted talar planes to account for the dome’s curvature, enabling more accurate lesion model ing and biomechanical analysis. Percent changes in osteochondral von Mises stress distribution and ankle stiffness parameters were investigated using finite element analysis. Based on the designated design parameters, 81 different cases were modeled and simulated. Results: Zones 7 (posteromedial, −33.2% change in stiffness for a 9 mm defect), 3 (anterolateral, −24.2% change in stiffness for a 9 mmdefect), and 8 (mid-posterior, −48.8% change in stiffness for a 9 mm defect) were found to be the most critical zones, showing evidence of decreased ankle stiffness in neutral, dorsiflexion, and plantarflexion positions, respectively. Zone 9 (posterolateral; neutral −4.7%, dorsi f lexion 5.4%, plantarflexion 0.17% stiffness change for a 9 mm defect) was found to be the least critical zone in terms of biomechanical stiffness. Conclusion: From a clinical standpoint, since lesions in zones 8, 7, and 3 significantly impact joint biomechanics compared to other zones, more aggressive cartilage restoration or augmentation could be required while lesions in less problematic zones like zone 9 can be treated withmicrofracture surgery. Cite this article as: Aslan L, Subasi O, Karaismailoglu B, et al. In silico assessment of talus osteochondral lesion size and location on biomechanical load distribution using tilted talar dome planes. Acta Orthop Traumatol Turc., 2025;59(6):361-367.
- Open Access
- 31 December 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (6) , 349-360
The effect of electrical bone stimulation on bone union in foot and ankle injuries: A scoping review
Objective: This study aimed to evaluate the reported efficacy of electrical bone stimulation (EBS) in promoting union in foot and ankle fractures and arthrodesis by synthesizing the available literature. Methods: A literature review was conducted using PubMed/Medline, EMBASE, ScienceDirect, Web of Science, and CINAHL. Study type, patient demographics, interventions, and outcomes were extracted. The Methodological Index for Non-Randomized Studies assessment tool was used for methodological quality assessment and for evaluating outcomes regarding union rates. Results: Fourteen studies involving 1253 patients met inclusion criteria from a total of 668 screened articles. These studies involved 1253 patients treated with EBS for foot and ankle fracture and fusion surgeries. The majority of investigations reported increased success unionization and reduced time to union using EBS methods including direct current, capacitated coupling, pulsed electromagnetic field (PEMF), low-intensity pulsed ultrasound (LIPUS), and combined magnetic field. Conclusion: Although existing evidence suggests that EBS may enhance union rates, there is no consensus regarding the most effective stimulation modality due to limited comparative data. Emerging modalities such as PEMF and LIPUS demonstrate promising results; however, well-designed comparative studies are needed to clarify their relative efficacy and safety profiles. Cite this article as: Schluter R, McLeod H, Ebrahimi A, et al. The effect of electrical bone stimulation on bone union in foot and ankle injuries: A scoping review. Acta Orthop Traumatol Turc., 2025;59(6):349-360.
- 31 December 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (6) , 349-360
Open AccessThe effect of electrical bone stimulation on bone union in foot and ankle injuries: A scoping review
Objective: This study aimed to evaluate the reported efficacy of electrical bone stimulation (EBS) in promoting union in foot and ankle fractures and arthrodesis by synthesizing the available literature. Methods: A literature review was conducted using PubMed/Medline, EMBASE, ScienceDirect, Web of Science, and CINAHL. Study type, patient demographics, interventions, and outcomes were extracted. The Methodological Index for Non-Randomized Studies assessment tool was used for methodological quality assessment and for evaluating outcomes regarding union rates. Results: Fourteen studies involving 1253 patients met inclusion criteria from a total of 668 screened articles. These studies involved 1253 patients treated with EBS for foot and ankle fracture and fusion surgeries. The majority of investigations reported increased success unionization and reduced time to union using EBS methods including direct current, capacitated coupling, pulsed electromagnetic field (PEMF), low-intensity pulsed ultrasound (LIPUS), and combined magnetic field. Conclusion: Although existing evidence suggests that EBS may enhance union rates, there is no consensus regarding the most effective stimulation modality due to limited comparative data. Emerging modalities such as PEMF and LIPUS demonstrate promising results; however, well-designed comparative studies are needed to clarify their relative efficacy and safety profiles. Cite this article as: Schluter R, McLeod H, Ebrahimi A, et al. The effect of electrical bone stimulation on bone union in foot and ankle injuries: A scoping review. Acta Orthop Traumatol Turc., 2025;59(6):349-360.
- 13 June 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (8) , 880-886
Intraoperative Radiation Exposure with Percutaneous vs Hybrid Hallux Valgus Correction: A Comparative Study
Background: Minimally invasive surgery (MIS) for hallux valgus (HV) deformity have gained popularity over traditional open techniques in recent years. However, MIS techniques pose concerns about increased fluoroscopy use and potential radiation exposure. This study seeks to compare the radiation exposure between percutaneous HV correction and a hybrid technique using a mini C-arm. Methods: In this prospective study, 68 patients underwent HV correction surgery between February 2022 and July 2023. Group 1 consisted of 37 patients who underwent percutaneous chevron and Akin osteotomy whereas group 2 consisted of 31 patients who underwent mini-open metatarsal distal chevron osteotomy + Akin percutaneous osteotomy (hybrid) technique. The patients were nonrandomized and allocated to each group according to their surgeons’ preference. Radiation exposure was measured using dose-area product (DAP), exposure duration, and passive dosimeters for the surgeon’s extremity, lens, and chest, as well as active dosimeters for the surgical team and patients. Results: Group 1 exhibited higher mean DAP (3.02 ± 1.91 cGy/cm 2 ) compared with group 2 (1.56 ± 1.57 cGy/cm 2 , P = .001). Mean radiation exposure duration was also higher in group 1 (56.74 ± 18.40 seconds) than in group 2 (23.54 ± 18.70 seconds, P < .001). Despite higher radiation exposure per case, cumulative doses remained below occupational safety thresholds set by the International Commission on Radiological Protection (ICRP) which are 5 cGy for whole body and lens of the eye, and 50 cGy for hand exposure. Conclusion: Although percutaneous HV correction is associated with greater intraoperative fluoroscopy use, cumulative radiation exposure to patients and surgical teams remains well within ICRP-recommended safety limits when mini C-arm fluoroscopy is used. These findings support the continued use of percutaneous techniques in appropriately selected patients and settings.
- 13 June 2025
- Published by SAGE Publications in Foot & Ankle International
- Vol. 46 (8) , 880-886
Intraoperative Radiation Exposure with Percutaneous vs Hybrid Hallux Valgus Correction: A Comparative Study
Background: Minimally invasive surgery (MIS) for hallux valgus (HV) deformity have gained popularity over traditional open techniques in recent years. However, MIS techniques pose concerns about increased fluoroscopy use and potential radiation exposure. This study seeks to compare the radiation exposure between percutaneous HV correction and a hybrid technique using a mini C-arm. Methods: In this prospective study, 68 patients underwent HV correction surgery between February 2022 and July 2023. Group 1 consisted of 37 patients who underwent percutaneous chevron and Akin osteotomy whereas group 2 consisted of 31 patients who underwent mini-open metatarsal distal chevron osteotomy + Akin percutaneous osteotomy (hybrid) technique. The patients were nonrandomized and allocated to each group according to their surgeons’ preference. Radiation exposure was measured using dose-area product (DAP), exposure duration, and passive dosimeters for the surgeon’s extremity, lens, and chest, as well as active dosimeters for the surgical team and patients. Results: Group 1 exhibited higher mean DAP (3.02 ± 1.91 cGy/cm 2 ) compared with group 2 (1.56 ± 1.57 cGy/cm 2 , P = .001). Mean radiation exposure duration was also higher in group 1 (56.74 ± 18.40 seconds) than in group 2 (23.54 ± 18.70 seconds, P < .001). Despite higher radiation exposure per case, cumulative doses remained below occupational safety thresholds set by the International Commission on Radiological Protection (ICRP) which are 5 cGy for whole body and lens of the eye, and 50 cGy for hand exposure. Conclusion: Although percutaneous HV correction is associated with greater intraoperative fluoroscopy use, cumulative radiation exposure to patients and surgical teams remains well within ICRP-recommended safety limits when mini C-arm fluoroscopy is used. These findings support the continued use of percutaneous techniques in appropriately selected patients and settings.
- Open Access
- 29 April 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (2) , 73-78
Does biceps tenodesis screw with forked eyelet decrease the risk of Popeye deformity when compared to traditional closed eyelet screws?
Objective: While many biomechanical studies have compared various biotenodesis materials for biceps tenodesis, there is a lack ofresearch comparing di!erent types of interference screws. This study aimed to compare the impact of a polyether ether ketone (PEEK) forked eyelet tenodesis screw with the traditional PEEK closed eyelet whipstitching technique. The focus was on evaluating the occurrence of Popeye deformity, which is an objective predictor of a successful arthroscopic suprapectoral long head of biceps tenodesis. Methods: A retrospective analysis was conducted on patients who underwent arthroscopic rotator cu! repair and biceps tenodesis performed by a single surgeon between January 2010 and 2020 at a single center. The follow-up period was at least 1 year. Exclusion criteria included previous shoulder surgery and osteoarthritis. Patients were divided into 2 groups based on the type of tenodesis anchor used: forked eyelet tenodesis screw versus closed eyelet tenodesis screw. The occurrence of Popeye deformity was compared between the 2 groups. Results: A total of 82 patients who underwent arthroscopic rotator cu! repair and biceps tenodesis were evaluated, with a mean follow-up of 24.5 ± 4 months. The patients operated on using forked eyelet tenodesis screw were labeled as Group I (n=72) and those with traditional PEEK closed eyelet screw as Group II (n=10). There were no significant di!erences between the groups in terms of age (Group I: 59.4 ± 5, Group II: 58.4 ± 4, P=.896), gender (both groups predominantly male, P=.886), and body mass index (Group I: 26.7 ± 2, Group II: 27 ± 3; P=.896). The overall rate of popeye deformity in all patients was 8% (n=7). No significant di!erence in popeye deformity occurrence was observed between the 2 groups (Group I: 6/72 (8.3%), Group II: 1/10 (10%); P=.998). Conclusion: The incidence of Popeye deformity after arthroscopic biceps tenodesis in patients undergoing concomitant rotator cu! repair is low. The choice of fixation anchor, whether a forked eyelet or closed eyelet PEEK anchor, does not significantly influence the occurrence of Popeye deformity. Cite this article as: Caliskan E, Buyukdo!an K, Eren I, Birsel O, Aslan L, Demirhan M. Does biceps tenodesis screw with forked eyelet decrease the risk of Popeye deformity when compared to traditional closed eyelet screws? Acta Orthop Traumatol Turc., 2025;59(2):73-78.
- 29 April 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (2) , 73-78
Open AccessDoes biceps tenodesis screw with forked eyelet decrease the risk of Popeye deformity when compared to traditional closed eyelet screws?
Objective: While many biomechanical studies have compared various biotenodesis materials for biceps tenodesis, there is a lack ofresearch comparing di!erent types of interference screws. This study aimed to compare the impact of a polyether ether ketone (PEEK) forked eyelet tenodesis screw with the traditional PEEK closed eyelet whipstitching technique. The focus was on evaluating the occurrence of Popeye deformity, which is an objective predictor of a successful arthroscopic suprapectoral long head of biceps tenodesis. Methods: A retrospective analysis was conducted on patients who underwent arthroscopic rotator cu! repair and biceps tenodesis performed by a single surgeon between January 2010 and 2020 at a single center. The follow-up period was at least 1 year. Exclusion criteria included previous shoulder surgery and osteoarthritis. Patients were divided into 2 groups based on the type of tenodesis anchor used: forked eyelet tenodesis screw versus closed eyelet tenodesis screw. The occurrence of Popeye deformity was compared between the 2 groups. Results: A total of 82 patients who underwent arthroscopic rotator cu! repair and biceps tenodesis were evaluated, with a mean follow-up of 24.5 ± 4 months. The patients operated on using forked eyelet tenodesis screw were labeled as Group I (n=72) and those with traditional PEEK closed eyelet screw as Group II (n=10). There were no significant di!erences between the groups in terms of age (Group I: 59.4 ± 5, Group II: 58.4 ± 4, P=.896), gender (both groups predominantly male, P=.886), and body mass index (Group I: 26.7 ± 2, Group II: 27 ± 3; P=.896). The overall rate of popeye deformity in all patients was 8% (n=7). No significant di!erence in popeye deformity occurrence was observed between the 2 groups (Group I: 6/72 (8.3%), Group II: 1/10 (10%); P=.998). Conclusion: The incidence of Popeye deformity after arthroscopic biceps tenodesis in patients undergoing concomitant rotator cu! repair is low. The choice of fixation anchor, whether a forked eyelet or closed eyelet PEEK anchor, does not significantly influence the occurrence of Popeye deformity. Cite this article as: Caliskan E, Buyukdo!an K, Eren I, Birsel O, Aslan L, Demirhan M. Does biceps tenodesis screw with forked eyelet decrease the risk of Popeye deformity when compared to traditional closed eyelet screws? Acta Orthop Traumatol Turc., 2025;59(2):73-78.
- Open Access
- 19 March 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (4) , 58-62
Routine histopathological examination of femoral heads and incidental metastatic bone disease in hip arthroplasty
Femoral neck fracture,hip arthroplasty,metastasis,pathology
- 19 March 2025
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 59 (4) , 58-62
Open AccessRoutine histopathological examination of femoral heads and incidental metastatic bone disease in hip arthroplasty
Femoral neck fracture,hip arthroplasty,metastasis,pathology