SKSupakit Kanitnate

Supakit Kanitnate

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Supakit Kanitnate has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Do we need to restore patellar thickness after total knee arthroplasty with patellar resurfacing?

    by Nattapol Tammachote, Teeramate Kraisin, Supakit Kanitnate

    Purpose The aim of this study was to investigate whether increased patellar thickness after resurfacing decreased knee flexion angle and had any effect on functional outcomes comparing with patellar thickness restoration (patelloplasty) in patients undergoing primary total knee arthroplasty (TKA) or not. Methods We retrospectively reviewed 220 patients undergoing primary TKA: 110 patients undergoing patelloplasty and 110 patients received overstuffed patellar resurfacing using subchondral bone cut at lateral facet technique were recruited. The mean increase in patellar thickness after resurfacing equal to 2 ± 1.2 mm. The outcomes were postoperative knee flexion angle and modified Western Ontario and McMaster University Osteoarthritis Index (WOMAC) score at minimum 2 year after surgery. Results The mean postoperative knee flexion angles were similar between overstuffed resurfacing group and patelloplasty group (132 ± 7° vs. 134 ± 8°, 95% confidence interval [CI] − 6.9–1.8°, p = 0.1). The mean increase in postoperative knee flexion was 13° in both groups (p = 0.94). The mean change of overall modified WOMAC score was also similar between the two groups (42 ± 12 vs. 39 ± 9 points, 95% CI − 1.7–9.4 points, p = 0.17). Conclusion This study demonstrated that increased patellar thickness has no effect on postoperative knee flexion angle and functional outcomes in TKA. The finding clarified the misunderstanding principle of native patellar thickness restoration after resurfacing which had made many surgeons to refrain from resurfacing especially in patient who had thin patella.


  • Synovium removal from the articular side of the quadriceps tendon around the superior pole of patella reduces the crepitus after total knee arthroplasty

    by Sukanis Chumchuen, Supakit Kanitnate, Kittipong Wattanasirisombat, Nattapol Tammachote

    Purpose The purpose of this study was to investigate whether synovium removal from the articular side of the quadriceps tendon around the superior pole of the patella after total knee arthroplasty (TKA) reduced the incidence of patellar crepitus (PC) or not. Methods We retrospectively reviewed 134 consecutive patients who underwent primary posterior stabilized (PS)-TKA by one surgeon from 2010 to 2013. Sixty-seven patients performed without touching synovium at superior pole of patella and 67 patients performed with removing all synovium from superior pole of patella were compared; none had patellar resurfacing. Patients were followed up two and six weeks, three, six and 12 months and annually thereafter. The primary outcome was the incidence of PC, detected during follow-up, and was graded as absent (0), fine (1), or coarse (2). Results At one year of follow-up, the synovial removal (SR) group had a significant lower rate of PC compared to the synovial preserved (SP) group: 15/67 (22%) vs 34/67 (51%), adjusted odds ratio = 0.29, 95% confidence interval (CI) = 0.14 to 0.64, P = 0.002. All PC in SR group were grade 1 while four knees in SP group were grade 2. Mean PC onset was eight months after surgery (range 1.5 to 12, P = 0.78) in both groups. Conclusion Removal of the synovium from the articular side of the quadriceps tendon around the superior pole of patellar reduced the incidence of PC after primary PS-TKA without patellar resurfacing. This is a promising technique and might enlighten surgeons to reduce the noise and improve patient satisfaction after total knee replacement.

  • The effect of immediate post-operative knee range of motion photographs on post-operative range of motion after total knee arthroplasty

    by Piya Pinsornsak, Supakit Kanitnate, Krit Boontanapibul

    Purpose We attempted to determine the effect of immediate post-operative knee range of motion (ROM) photographs on improving ROM after total knee arthroplasty (TKA). Methods Sixty patients, scheduled for unilateral primary TKA, were randomized into two groups. The photo group (n = 30) were immediately shown post-TKA knee ROM photographs as motivation for rehabilitation. The non-photo group (n = 30) received identical post-operative pain control and rehabilitation programs. Post-operative knee ROM and Knee Society Scores (KSS) at day three, six weeks, three months, six months, one year, and two years were evaluated. Outcome assessors were blinded to the groups during the study. Results Patients in the photo group had better knee flexion on day three (99.9° ± 15.3°, 95% confidence interval (CI) 94.1-105.7° vs. 92.3° ± 11.4°, 95% CI 87.9-96.8°; p = 0.038) and at six weeks (120.9° ± 13.4°, 95% CI 115.7-126.0° vs. 112.5° ± 13.6°, 95% CI 107.2-117.8°; p = 0.023); however, there were no differences in range of flexion beyond six weeks post-operatively. Knee extension did not significantly differ throughout. Clinical KSS was significantly higher in the photo group at six weeks (90.7° ± 6.2° vs. 86.6° ± 6.4°, p = 0.017). Functional KSS showed no differences between groups during follow-up. Conclusion Showing knee ROM photographs seemed to result in significant improvement of knee flexion and clinical KSS in the first 6 weeks post-TKA and may be recommended as part of post-TKA rehabilitation.


  • High-dose (3 g) topical tranexamic acid has higher potency in reducing blood loss after total knee arthroplasty compared with low dose (500 mg): a double‐blind randomized controlled trial

    by Nattapol Tammachote, Raphi Raphiphan, Supakit Kanitnate

    BackgroundTopical intra-articular tranexamic acid (IA-TXA) has been proven to be safe and effective in reducing postoperative blood loss after primary total knee arthroplasty (TKA). The objective of this study was to investigate the efficacy of high dose (3 g) compared with low dose (500 mg) of IA-TXA in postoperative blood loss after primary TKA.MethodsA double-blind randomized controlled trial was conducted in 80 patients who had undergone primary TKA. The patients were divided into two groups according to intra-articular TXA doses: high-dose group (3 g IA-TXA) and low-dose group (500 mg IA-TXA). The drug was injected into the joint capsule after fascial closure without suction drainage. The primary outcomes were maximum hemoglobin drop (g/dL) and calculated total blood loss (mL). Postoperative blood transfusions, thromboembolic events and functional outcomes were also recorded.ResultsThe mean maximum hemoglobin drop was 1.3 g/dL lower in 3 g IA-TXA group compared to the 500 mg IA-TXA group [1.7 vs 3.0 g/dL, 95% confidence interval (CI) 0.9-1.7 g/dL, P<0.001]. The 3 g IA-TXA group had 370 mL less calculated total blood loss compared to the 500 mg IA-TXA group (551 vs 921 mL, 95% CI 252-489 mL, P<0.001). One patient in the 500 mg IA-TXA group required transfusion, while no patient in the 3 g IA-TXA group received transfusion (P=0.31). Any thromboembolic event was not found, and functional outcome was similar between the two groups.ConclusionsApplication of high-dose, 3 g topical IA-TXA was 43% more effective in reducing postoperative blood loss compared with low dose of 500 mg in primary TKA. Optimal doses in between the above two doses may be a worthwhile further investigation.


  • Rotational component alignment in patient-specific total knee arthroplasty compared with conventional cutting instrument

    by Nuttawut Chanalithichai, Nattapol Tammachote, Chane Jitapunkul, Supakit Kanitnate

    Although many studies investigated the accuracy of customized cutting block (CCB), the data on rotational alignment are still lacking. The study aimed to assess whether CCB improved the component rotational position compared with conventional cutting instrument (CCI) using computed tomography scanning.


  • Electric cautery does not reduce blood loss in primary total knee arthroplasty compared with scalpel only surgery a double-blinded randomized controlled trial

    by Nattapol Tammachote, Supakit Kanitnate

    The purpose of this study was to systematically compare blood loss between the electric cautery and scalpel used in primary total knee arthroplasty (TKA).