Junhong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Junhong Wang has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Lei Li
1 shared publicationShaoming Sun
Hefei Institutes of Physical Science, University of Science and Technology of China, Hefei, China
1 shared publication- Shaoming Sun
Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
1 shared publication Yining Sun
Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China
1 shared publication- Yining Sun
Institute of Intelligent Machines, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China
1 shared publication Zhangling Duan
1 shared publication
Latest Publications
- 2 February 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 118
Bayesian-optimized filtering and hybrid ViT-LSTM model for knee joint abnormality recognition using sEMG
- 2 February 2026
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 118
Bayesian-optimized filtering and hybrid ViT-LSTM model for knee joint abnormality recognition using sEMG
- Open Access
A Muscle Fatigue Classification Model Based on LSTM and Improved Wavelet Packet Threshold
Previous studies have used the anaerobic threshold (AT) to non-invasively predict muscle fatigue. This study proposes a novel method for the automatic classification of muscle fatigue based on surface electromyography (sEMG). The sEMG data were acquired from 20 participants during an incremental test on a cycle ergometer using sEMG sensors placed on the vastus rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), and gastrocnemius (GA) muscles of the left leg. The ventilation volume (VE), oxygen uptake (VO2), and carbon dioxide production (VCO2) data of each participant were collected during the test. Then, we extracted the time-domain and frequency-domain features of the sEMG signal denoised by the improved wavelet packet threshold denoising algorithm. In this study, we propose a new muscle fatigue recognition model based on the long short-term memory (LSTM) network. The LSTM network was trained to classify muscle fatigue using sEMG signal features. The results showed that the improved wavelet packet threshold function has better performance in denoising sEMG signals than hard threshold and soft threshold functions. The classification performance of the muscle fatigue recognition model proposed in this paper is better than that of CNN (convolutional neural network), SVM (support vector machine), and the classification models proposed by other scholars. The best performance of the LSTM network was achieved with 70% training, 10% validation, and 20% testing rates. Generally, the proposed model can be used to monitor muscle fatigue.
Open AccessA Muscle Fatigue Classification Model Based on LSTM and Improved Wavelet Packet Threshold
Previous studies have used the anaerobic threshold (AT) to non-invasively predict muscle fatigue. This study proposes a novel method for the automatic classification of muscle fatigue based on surface electromyography (sEMG). The sEMG data were acquired from 20 participants during an incremental test on a cycle ergometer using sEMG sensors placed on the vastus rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM), and gastrocnemius (GA) muscles of the left leg. The ventilation volume (VE), oxygen uptake (VO2), and carbon dioxide production (VCO2) data of each participant were collected during the test. Then, we extracted the time-domain and frequency-domain features of the sEMG signal denoised by the improved wavelet packet threshold denoising algorithm. In this study, we propose a new muscle fatigue recognition model based on the long short-term memory (LSTM) network. The LSTM network was trained to classify muscle fatigue using sEMG signal features. The results showed that the improved wavelet packet threshold function has better performance in denoising sEMG signals than hard threshold and soft threshold functions. The classification performance of the muscle fatigue recognition model proposed in this paper is better than that of CNN (convolutional neural network), SVM (support vector machine), and the classification models proposed by other scholars. The best performance of the LSTM network was achieved with 70% training, 10% validation, and 20% testing rates. Generally, the proposed model can be used to monitor muscle fatigue.
- Open Access
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 207914-207922
Recognition of Muscle Fatigue Status Based on Improved Wavelet Threshold and CNN-SVM
This study proposed a muscle fatigue classification method based on surface electromyography (sEMG) signals to achieve accurate muscle fatigue detection and classification. A total of 20 healthy young participants (14 men and 6 women) were recruited for fatigue testing on a cycle ergometer, and sEMG signals and oxygen uptake were recorded during the test. First, the measured sEMG signals were denoised with an improved wavelet threshold method. Second, the V-slope method was used to identify the ventilation threshold (VT) to reflect the muscle fatigue state. The time- and frequency-domain features of the sEMG signals were extracted, including root mean square, integrated electromyography, median frequency, mean power frequency, and band spectral entropy. Third, the time- and frequency-domain features of the sEMG signals were labeled either “normal” or “fatigued” based on the VT. Finally, the statistical features of 16 participants were selected as the training data set of the Convolutional Neural Network–Support Vector Machine (CNN-SVM), Support Vector Machine, Convolutional Neural Network, and Particle Swarm Optimization–Support Vector Machine algorithms. In addition, the statistical features of the four remaining participants were used as the test data set to analyze the classification accuracy of the four aforementioned algorithms. Experimental results indicated that the denoising effect of the improved wavelet threshold algorithm proposed in this study was satisfactory. The CNN-SVM algorithm achieved accurate muscle fatigue classification and 80.33%–86.69% classification accuracy.
- 17 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 207914-207922
Open AccessRecognition of Muscle Fatigue Status Based on Improved Wavelet Threshold and CNN-SVM
This study proposed a muscle fatigue classification method based on surface electromyography (sEMG) signals to achieve accurate muscle fatigue detection and classification. A total of 20 healthy young participants (14 men and 6 women) were recruited for fatigue testing on a cycle ergometer, and sEMG signals and oxygen uptake were recorded during the test. First, the measured sEMG signals were denoised with an improved wavelet threshold method. Second, the V-slope method was used to identify the ventilation threshold (VT) to reflect the muscle fatigue state. The time- and frequency-domain features of the sEMG signals were extracted, including root mean square, integrated electromyography, median frequency, mean power frequency, and band spectral entropy. Third, the time- and frequency-domain features of the sEMG signals were labeled either “normal” or “fatigued” based on the VT. Finally, the statistical features of 16 participants were selected as the training data set of the Convolutional Neural Network–Support Vector Machine (CNN-SVM), Support Vector Machine, Convolutional Neural Network, and Particle Swarm Optimization–Support Vector Machine algorithms. In addition, the statistical features of the four remaining participants were used as the test data set to analyze the classification accuracy of the four aforementioned algorithms. Experimental results indicated that the denoising effect of the improved wavelet threshold algorithm proposed in this study was satisfactory. The CNN-SVM algorithm achieved accurate muscle fatigue classification and 80.33%–86.69% classification accuracy.