Sunitha Vaidyanathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sunitha Vaidyanathan has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Kothandam Sivakumar
Department of Pediatric Cardiology, Institute of Cardiovascular Diseases, Madras Medical Mission, Chennai, Tamil Nadu, India
1 shared publication - Monica Rajendran
Department of Pediatric Cardiology, Institute of Cardio Vascular Diseases, Madras Medical Mission, Chennai, India
1 shared publication Shakeel Qureshi
Evelina London Children’s Hospital, Guy’s and St. Thomas’ NHS Foundation Trust, United Kingdom (S.Q.).
1 shared publication- Sreeja Pavithran
Institute of Cardio Vascular Diseases, The Madras Medical Mission
1 shared publication
Latest Publications
- 1 December 2020
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 13 (12) , 334-343
Simple Diagnostic Tools May Guide Transcatheter Closure of Superior Sinus Venosus Defects Without Advanced Imaging Techniques
Background: There is a recent interest in nonsurgical correction of superior sinus venosus defects. Patient selection is currently based on advanced imaging and printing technologies. Simple clinical tools to select patients will expand its applicability in developing countries. Methods: Defects caudally extending toward the oval fossa and right upper pulmonary veins draining beyond the cavoatrial junction on transesophageal echocardiography were excluded. Balloon interrogation of cavoatrial junction confirmed complete occlusion of the defect with unobstructed pulmonary venous drainage to left atrium. Single long covered stents or overlapping covered stents were used to exclude sinus venosus defects. Closure of left-to-right interatrial shunt without causing pulmonary vein occlusion was confirmed on follow-up imaging. Results: Forty-four patients selected after transesophageal echocardiography underwent balloon interrogation with monitoring of right upper pulmonary vein. Eighteen out of 44 patients were ineligible. Twenty-four eligible patients with closure of left-to-right interatrial shunt without pulmonary vein occlusion underwent covered stent exclusion using single long stents in 15 and overlapping stents in the rest, while 2 patients are awaiting the procedure. Four patients aged 6 to 16 years received stents that were 18 mm or larger. Three patients had stent embolization that required surgical correction in 2 but in the last patient was managed nonsurgically with an overlapping covered stent with good final outcomes. Procedure was successful in 22 patients. At a median follow-up of 20 months (range, 3–54 months), there were no adverse events. Follow-up imaging showed trivial left-to-right shunt in 4 and unobstructed pulmonary veins in all patients. Conclusions: Transesophageal echocardiography and balloon interrogation identified 60% of the patients with sinus venosus defects to be eligible for catheter closure. Overlapping stents are an alternative to custom-made long stents. Transesophageal echocardiography confirms procedural success on follow-up. Advanced imaging and printing technologies are not essential for successful outcomes and thus simple tests increase the feasibility in developing countries.
- 1 December 2020
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 13 (12) , 334-343
Simple Diagnostic Tools May Guide Transcatheter Closure of Superior Sinus Venosus Defects Without Advanced Imaging Techniques
Background: There is a recent interest in nonsurgical correction of superior sinus venosus defects. Patient selection is currently based on advanced imaging and printing technologies. Simple clinical tools to select patients will expand its applicability in developing countries. Methods: Defects caudally extending toward the oval fossa and right upper pulmonary veins draining beyond the cavoatrial junction on transesophageal echocardiography were excluded. Balloon interrogation of cavoatrial junction confirmed complete occlusion of the defect with unobstructed pulmonary venous drainage to left atrium. Single long covered stents or overlapping covered stents were used to exclude sinus venosus defects. Closure of left-to-right interatrial shunt without causing pulmonary vein occlusion was confirmed on follow-up imaging. Results: Forty-four patients selected after transesophageal echocardiography underwent balloon interrogation with monitoring of right upper pulmonary vein. Eighteen out of 44 patients were ineligible. Twenty-four eligible patients with closure of left-to-right interatrial shunt without pulmonary vein occlusion underwent covered stent exclusion using single long stents in 15 and overlapping stents in the rest, while 2 patients are awaiting the procedure. Four patients aged 6 to 16 years received stents that were 18 mm or larger. Three patients had stent embolization that required surgical correction in 2 but in the last patient was managed nonsurgically with an overlapping covered stent with good final outcomes. Procedure was successful in 22 patients. At a median follow-up of 20 months (range, 3–54 months), there were no adverse events. Follow-up imaging showed trivial left-to-right shunt in 4 and unobstructed pulmonary veins in all patients. Conclusions: Transesophageal echocardiography and balloon interrogation identified 60% of the patients with sinus venosus defects to be eligible for catheter closure. Overlapping stents are an alternative to custom-made long stents. Transesophageal echocardiography confirms procedural success on follow-up. Advanced imaging and printing technologies are not essential for successful outcomes and thus simple tests increase the feasibility in developing countries.