Holger Zagst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Holger Zagst has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hermann Wätzig
Institute of Medicinal and Pharmaceutical Chemistry Technische Universität Braunschweig Braunschweig Germany
2 shared publications - Antonia Wittmann
Institute for Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Beethovenstr. 55, 38106 Braunschweig, Germany
1 shared publication - Dina-Mareike Menges
Institute for Medicinal and Pharmaceutical Chemistry, Technische Universität Braunschweig, Beethovenstr. 55, 38106 Braunschweig, Germany
1 shared publication - Heike Bunjes
Technische Universität Braunschweig, Institut für Pharmazeutische Technologie und Biopharmazie, Mendelssohnstr. 1, 38106 Braunschweig, Germany; Technische Universität Braunschweig, Zentrum für Pharmaverfahrenstechnik - PVZ, Franz-Liszt-Str. 35a, 38106 Braunschweig, Germany
1 shared publication - Judith Kuntsche
University of Southern Denmark
1 shared publication - Julius Sundermann
AbbVie Deutschland GmbH & Co. KG, Knollstrasse 50, 67061 Ludwigshafen, Germany
1 shared publication
Latest Publications
- Open Access
- 21 May 2023
- Published by MDPI AG in Separations
- Vol. 10 (5) , 320
Capillary Zone Electrophoresis with Light-Emitting Diode-Induced Fluorescence Detection for the Analysis of Monoclonal Antibodies: Detector Optimization through Design of Experiments and Comparison to UV Detection
Capillary zone electrophoresis (CZE) is an important technique for the analysis of monoclonal antibodies (mAbs). A recently released light-emitting diode (LED)-induced fluorescence (LEDIF) detector equipped with a 275 nm LED for the detection of proteins through their native fluorescence was used in this study and compared to results obtained using the predominant detection mode, the measurement of the absorption of ultraviolet light (UV detection). This was accomplished using an established CZE method for the analysis of three mAbs: NISTmAb, matuzumab, and Intact Mass Check Standard (Waters). For this purpose, the detector’s settings were first optimized using a design of experiments approach. Three factors, rise time, photomultiplier high voltage supply, and acquisition frequency, were optimized by means of a D-optimal design. The optimal settings were then used for the investigation of signal-to-noise ratios (S/Ns), linearity, and precision. LEDIF detection offered a similar separation quality, up to 12 times higher S/Ns, and lower limits of detection compared to UV detection. Repeatability was excellent, with relative standard deviations (RSDs) of approximately 1% for percentage areas. For intermediate precision, RSDs of n = 3 × 10) were typically achieved. Overall, LEDIF detection was found to be an excellent and easily optimizable alternative to UV detection.
- 21 May 2023
- Published by MDPI AG in Separations
- Vol. 10 (5) , 320
Open AccessCapillary Zone Electrophoresis with Light-Emitting Diode-Induced Fluorescence Detection for the Analysis of Monoclonal Antibodies: Detector Optimization through Design of Experiments and Comparison to UV Detection
Capillary zone electrophoresis (CZE) is an important technique for the analysis of monoclonal antibodies (mAbs). A recently released light-emitting diode (LED)-induced fluorescence (LEDIF) detector equipped with a 275 nm LED for the detection of proteins through their native fluorescence was used in this study and compared to results obtained using the predominant detection mode, the measurement of the absorption of ultraviolet light (UV detection). This was accomplished using an established CZE method for the analysis of three mAbs: NISTmAb, matuzumab, and Intact Mass Check Standard (Waters). For this purpose, the detector’s settings were first optimized using a design of experiments approach. Three factors, rise time, photomultiplier high voltage supply, and acquisition frequency, were optimized by means of a D-optimal design. The optimal settings were then used for the investigation of signal-to-noise ratios (S/Ns), linearity, and precision. LEDIF detection offered a similar separation quality, up to 12 times higher S/Ns, and lower limits of detection compared to UV detection. Repeatability was excellent, with relative standard deviations (RSDs) of approximately 1% for percentage areas. For intermediate precision, RSDs of n = 3 × 10) were typically achieved. Overall, LEDIF detection was found to be an excellent and easily optimizable alternative to UV detection.
- Open Access
- 25 November 2020
- Published by MDPI AG in Pharmaceutics
- Vol. 12 (12) , 1143
Bone Morphogenetic Protein 2 (BMP-2) Aggregates Can be Solubilized by Albumin—Investigation of BMP-2 Aggregation by Light Scattering and Electrophoresis
Bone morphogenetic protein 2 (BMP-2) has a high tendency to aggregate at physiological pH and physiological ionic strength, which can complicate the development of growth factor delivery systems. The aggregation behavior in differently concentrated BMP-2 solutions was investigated using dynamic and static light scattering. It was found that at higher concentrations larger aggregates are formed, whose size decreases again with increasing dilution. A solubilizing effect and therefore less aggregation was observed upon the addition of albumin. Imaged capillary isoelectric focusing and the simulation of the surface charges of BMP-2 were used to find a possible explanation for the unusually low solubility of BMP-2 at physiological pH. In addition to hydrophobic interactions, attractive electrostatic interactions might be decisive in the aggregation of BMP-2 due to the particular distribution of surface charges. These results help to better understand the solubility behavior of BMP-2 and thus support future pharmaceutical research and the development of new strategies for the augmentation of bone healing.
- 25 November 2020
- Published by MDPI AG in Pharmaceutics
- Vol. 12 (12) , 1143
Open AccessBone Morphogenetic Protein 2 (BMP-2) Aggregates Can be Solubilized by Albumin—Investigation of BMP-2 Aggregation by Light Scattering and Electrophoresis
Bone morphogenetic protein 2 (BMP-2) has a high tendency to aggregate at physiological pH and physiological ionic strength, which can complicate the development of growth factor delivery systems. The aggregation behavior in differently concentrated BMP-2 solutions was investigated using dynamic and static light scattering. It was found that at higher concentrations larger aggregates are formed, whose size decreases again with increasing dilution. A solubilizing effect and therefore less aggregation was observed upon the addition of albumin. Imaged capillary isoelectric focusing and the simulation of the surface charges of BMP-2 were used to find a possible explanation for the unusually low solubility of BMP-2 at physiological pH. In addition to hydrophobic interactions, attractive electrostatic interactions might be decisive in the aggregation of BMP-2 due to the particular distribution of surface charges. These results help to better understand the solubility behavior of BMP-2 and thus support future pharmaceutical research and the development of new strategies for the augmentation of bone healing.