Eleonora Micheletti
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Eleonora Micheletti has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Abdul Jabbar Khan
Department of Ophthalmology Lincolnshire United Hospitals NHS Trust Lincoln UK
1 shared publication- Carlo Bruttini
University Eye Clinic, IRCCS, Policlinico San Matteo, Pavia, Italy
1 shared publication - Francesco Oddone
IRCCS-Fondazione Bietti, Rome, Italy
1 shared publication Georgios Kontos
Oxford Eye Hospital, John Radcliffe, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
1 shared publication- Giovanni De Angelis
Department of Surgical & Clinical, Diagnostic and Pediatric Sciences, Section of Ophthalmology, University of Pavia-IRCCS Fondazione Policlinico San Matteo, 27100 Pavia, Italy
1 shared publication - Ivano Riva
IRCCS - Fondazione Bietti, Rome, Italy
1 shared publication
Latest Publications
- Open Access
- 1 December 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 4387-4395
Intraocular Pressure Spikes Following Cataract Extraction: Hydrophobic vs Hydrophilic Acrylic Lenses
Purpose: To investigate the intraocular pressure (IOP) changes after cataract extraction (CE) with an acrylic hydrophobic EyeCee One versus a hydrophilic Akreos MI60 intraocular lens (IOL) implant. Methods: All patients who underwent CE with acrylic EyeCee One IOL implant and Akreos MI60 IOL implants were included. Parameters such as age, sex, history of glaucoma or ocular hypertension (OHT), IOP, axial length (AXL), anterior chamber depth (ACD) and type of IOL implant were measured. Results: A total of 193 eyes of 193 patients were included. Of them, 115 eyes underwent CE with EyeCee One IOL, while 78 eyes underwent CE with Akreos MI60 IOL. Mean age (± SD) was 76.1 (± 9.4). A preoperative diagnosis of open-angle glaucoma (OAG) and ocular hypertension (OHT) was found in 10.9% and 3.6%, respectively. Mean pre-operative IOP was 16.8 ± 4.1. Mean IOP reduction at 2 months follow-up after CE was 2.8 ± 3.7 mmHg in the Akreos group and 0.3 (± 4.3) in the Eye Cee One group (<0.001). Five patients who underwent EyeCee One IOL implant had IOP rise ≥ 10 mmHg at 2 months follow-up, whereas none of the patients in the Akreos MI60 group had IOP spikes. Age and type of IOL implant were associated with greater IOP reduction in both univariable and multivariable analyses. Conclusion: CE with acrylic hydrophobic EyeCee One IOL implant was associated with more IOP spikes compared to the acrylic hydrophilic Akreos MI60 IOL implant. Further studies are warranted to clarify the association between IOP and IOL implants.
- 1 December 2025
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 19, 4387-4395
Open AccessIntraocular Pressure Spikes Following Cataract Extraction: Hydrophobic vs Hydrophilic Acrylic Lenses
Purpose: To investigate the intraocular pressure (IOP) changes after cataract extraction (CE) with an acrylic hydrophobic EyeCee One versus a hydrophilic Akreos MI60 intraocular lens (IOL) implant. Methods: All patients who underwent CE with acrylic EyeCee One IOL implant and Akreos MI60 IOL implants were included. Parameters such as age, sex, history of glaucoma or ocular hypertension (OHT), IOP, axial length (AXL), anterior chamber depth (ACD) and type of IOL implant were measured. Results: A total of 193 eyes of 193 patients were included. Of them, 115 eyes underwent CE with EyeCee One IOL, while 78 eyes underwent CE with Akreos MI60 IOL. Mean age (± SD) was 76.1 (± 9.4). A preoperative diagnosis of open-angle glaucoma (OAG) and ocular hypertension (OHT) was found in 10.9% and 3.6%, respectively. Mean pre-operative IOP was 16.8 ± 4.1. Mean IOP reduction at 2 months follow-up after CE was 2.8 ± 3.7 mmHg in the Akreos group and 0.3 (± 4.3) in the Eye Cee One group (<0.001). Five patients who underwent EyeCee One IOL implant had IOP rise ≥ 10 mmHg at 2 months follow-up, whereas none of the patients in the Akreos MI60 group had IOP spikes. Age and type of IOL implant were associated with greater IOP reduction in both univariable and multivariable analyses. Conclusion: CE with acrylic hydrophobic EyeCee One IOL implant was associated with more IOP spikes compared to the acrylic hydrophilic Akreos MI60 IOL implant. Further studies are warranted to clarify the association between IOP and IOL implants.
- Open Access
- 1 October 2022
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 140 (10) , 1011-1012
A Dome-Shaped Eyelid Nodule in a Young White Man
A 27-year-old White man presented with a recent onset of malaise, chills, night sweats, sore throat with difficulty swallowing, and a skin rash affecting his trunk, limbs, and genitalia. His right eye was red with watery discharge and there was a dome-shaped nodule on his lower eyelid. What would you do next?
- 1 October 2022
- Published by American Medical Association (AMA) in JAMA Ophthalmology
- Vol. 140 (10) , 1011-1012
Open AccessA Dome-Shaped Eyelid Nodule in a Young White Man
A 27-year-old White man presented with a recent onset of malaise, chills, night sweats, sore throat with difficulty swallowing, and a skin rash affecting his trunk, limbs, and genitalia. His right eye was red with watery discharge and there was a dome-shaped nodule on his lower eyelid. What would you do next?
- Open Access
- 25 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 3814
Anterior Chamber Angle Assessment Techniques: A Review
Assessment of the anterior chamber angle (ACA) is an essential part of the ophthalmological examination. It is intrinsically related to the diagnosis and treatment of glaucoma and has a role in its prevention. Although slit-lamp gonioscopy is considered the gold-standard technique for ACA evaluation, its poor reproducibility and the long learning curve are well-known shortcomings. Several new imaging techniques for angle evaluation have been developed in the recent years. However, whether these instruments may replace or not gonioscopy in everyday clinical practice remains unclear. This review summarizes the last findings in ACA evaluation, focusing on new instruments and their application to the clinical practice. Special attention will be given to the comparison between these new techniques and traditional slit-lamp gonioscopy. Whereas ultrasound biomicroscopy and anterior segment optical coherence tomography provide quantitative measurements of the anterior segment’s structures, new gonio-photographic systems allow for a qualitative assessment of angle findings, similarly to gonioscopy. Recently developed deep learning algorithms provide an automated classification of angle images, aiding physicians in taking faster and more efficient decisions. Despite new imaging techniques made analysis of the ACA more objective and practical, the ideal method for ACA evaluation has still to be determined.
- 25 November 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (12) , 3814
Open AccessAnterior Chamber Angle Assessment Techniques: A Review
Assessment of the anterior chamber angle (ACA) is an essential part of the ophthalmological examination. It is intrinsically related to the diagnosis and treatment of glaucoma and has a role in its prevention. Although slit-lamp gonioscopy is considered the gold-standard technique for ACA evaluation, its poor reproducibility and the long learning curve are well-known shortcomings. Several new imaging techniques for angle evaluation have been developed in the recent years. However, whether these instruments may replace or not gonioscopy in everyday clinical practice remains unclear. This review summarizes the last findings in ACA evaluation, focusing on new instruments and their application to the clinical practice. Special attention will be given to the comparison between these new techniques and traditional slit-lamp gonioscopy. Whereas ultrasound biomicroscopy and anterior segment optical coherence tomography provide quantitative measurements of the anterior segment’s structures, new gonio-photographic systems allow for a qualitative assessment of angle findings, similarly to gonioscopy. Recently developed deep learning algorithms provide an automated classification of angle images, aiding physicians in taking faster and more efficient decisions. Despite new imaging techniques made analysis of the ACA more objective and practical, the ideal method for ACA evaluation has still to be determined.