Jana Starčuková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jana Starčuková has a total of 80 co-authors. Here are the top co-authors by number of shared publications:
- Zenon Starčuk
Institute of Scientific Instruments Czech Academy of Sciences Brno Czechia
14 shared publications - Amirmohammad Shamaei
Electrical and Software Engineering, University of Calgary, Calgary, AB, Canada; Hotchkiss Brain Institute, University of Calgary, Calgary, AB, Canada
3 shared publications Amir M Shamaei
Institute of Scientific Instruments of the Czech Academy of Sciences
2 shared publications- Cristina Cudalbu
CIBM Center for Biomedical Imaging Lausanne Switzerland
2 shared publications Danielle Graveron-Demilly
2 shared publications- Dunja Simicic
The Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
2 shared publications
Latest Publications
- 23 December 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (2) , e5304
Fast High‐Resolution Metabolite Mapping in the rat Brain Using 1H‐FID‐MRSI at 14.1 T
Magnetic resonance spectroscopic imaging (MRSI) enables the simultaneous noninvasive acquisition of MR spectra from multiple spatial locations inside the brain. Although 1H‐MRSI is increasingly used in the human brain, it is not yet widely applied in the preclinical setting, mostly because of difficulties specifically related to very small nominal voxel size in the rat brain and low concentration of brain metabolites, resulting in low signal‐to‐noise ratio (SNR). In this context, we implemented a free induction decay 1H‐MRSI sequence (1H‐FID‐MRSI) in the rat brain at 14.1 T. We combined the advantages of 1H‐FID‐MRSI with the ultra‐high magnetic field to achieve higher SNR, coverage, and spatial resolution in the rat brain and developed a custom dedicated processing pipeline with a graphical user interface for Bruker 1H‐FID‐MRSI: MRS4Brain toolbox. LCModel fit, using the simulated metabolite basis set and in vivo measured MM, provided reliable fits for the data at acquisition delays of 1.30 ms. The resulting Cramér–Rao lower bounds were sufficiently low (< 30%) for eight metabolites of interest (total creatine, N‐acetylaspartate, N‐acetylaspartate + N‐acetylaspartylglutamate, total choline, glutamine, glutamate, myo‐inositol, and taurine), leading to highly reproducible metabolic maps. Similar spectral quality and metabolic maps were obtained with one and two averages, with slightly better contrast and brain coverage due to increased SNR in the latter case. Furthermore, the obtained metabolic maps were accurate enough to confirm the previously known brain regional distribution of some metabolites. The acquisitions proved high reproducibility over time. We demonstrated that the increased SNR and spectral resolution at 14.1 T can be translated into high spatial resolution in 1H‐FID‐MRSI of the rat brain in 13 min using the sequence and processing pipeline described herein. High‐resolution 1H‐FID‐MRSI at 14.1 T provided robust, reproducible, and high‐quality metabolic mapping of brain metabolites with minimal technical limitations.
- 23 December 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (2) , e5304
Fast High‐Resolution Metabolite Mapping in the rat Brain Using 1H‐FID‐MRSI at 14.1 T
Magnetic resonance spectroscopic imaging (MRSI) enables the simultaneous noninvasive acquisition of MR spectra from multiple spatial locations inside the brain. Although 1H‐MRSI is increasingly used in the human brain, it is not yet widely applied in the preclinical setting, mostly because of difficulties specifically related to very small nominal voxel size in the rat brain and low concentration of brain metabolites, resulting in low signal‐to‐noise ratio (SNR). In this context, we implemented a free induction decay 1H‐MRSI sequence (1H‐FID‐MRSI) in the rat brain at 14.1 T. We combined the advantages of 1H‐FID‐MRSI with the ultra‐high magnetic field to achieve higher SNR, coverage, and spatial resolution in the rat brain and developed a custom dedicated processing pipeline with a graphical user interface for Bruker 1H‐FID‐MRSI: MRS4Brain toolbox. LCModel fit, using the simulated metabolite basis set and in vivo measured MM, provided reliable fits for the data at acquisition delays of 1.30 ms. The resulting Cramér–Rao lower bounds were sufficiently low (< 30%) for eight metabolites of interest (total creatine, N‐acetylaspartate, N‐acetylaspartate + N‐acetylaspartylglutamate, total choline, glutamine, glutamate, myo‐inositol, and taurine), leading to highly reproducible metabolic maps. Similar spectral quality and metabolic maps were obtained with one and two averages, with slightly better contrast and brain coverage due to increased SNR in the latter case. Furthermore, the obtained metabolic maps were accurate enough to confirm the previously known brain regional distribution of some metabolites. The acquisitions proved high reproducibility over time. We demonstrated that the increased SNR and spectral resolution at 14.1 T can be translated into high spatial resolution in 1H‐FID‐MRSI of the rat brain in 13 min using the sequence and processing pipeline described herein. High‐resolution 1H‐FID‐MRSI at 14.1 T provided robust, reproducible, and high‐quality metabolic mapping of brain metabolites with minimal technical limitations.
- Open Access
- 15 December 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (1) , e5309
Deuterium Metabolic Imaging Enables the Tracing of Substrate Fluxes Through the Tricarboxylic Acid Cycle in the Liver
Alterations in tricarboxylic acid (TCA) cycle metabolism are associated with hepatic metabolic disorders. Elevated hepatic acetate concentrations, often attributed to high caloric intake, are recognized as a pivotal factor in the etiology of obesity and metabolic syndrome. Therefore, the assessment of acetate breakdown and TCA cycle activity plays a central role in understanding the impact of diet‐induced alterations on liver metabolism. Magnetic resonance‐based deuterium metabolic imaging (DMI) could help to unravel the underlying mechanisms involved in disease development and progression, however, the application of conventional deuterated glucose does not lead to substantial enrichment in hepatic glutamine and glutamate. This study aimed to demonstrate the feasibility of DMI for tracking deuterated acetate breakdown via the TCA cycle in lean and diet‐induced fatty liver (FL) rats using 3D DMI after an intraperitoneal infusion of sodium acetate‐d3 at 9.4T. Localized and nonlocalized liver spectra acquired at 10 time points post‐injection over a 130‐min study revealed similar intrahepatic acetate uptake in both animal groups (AUCFL = 717.9 ± 131.1 mM▯min−1, AUClean = 605.1 ± 119.9 mM▯min−1, p = 0.62). Metabolic breakdown could be observed in both groups with an emerging glutamine/glutamate (Glx) peak as a downstream metabolic product (AUCFL = 113.6 ± 23.8 mM▯min−1, AUClean = 136.7 ± 41.7 mM▯min−1, p = 0.68).This study showed the viability of DMI for tracking substrate flux through the TCA cycle, underscoring its methodological potential for imaging metabolic processes in the body.
- 15 December 2024
- Published by Wiley in NMR in Biomedicine
- Vol. 38 (1) , e5309
Open AccessDeuterium Metabolic Imaging Enables the Tracing of Substrate Fluxes Through the Tricarboxylic Acid Cycle in the Liver
Alterations in tricarboxylic acid (TCA) cycle metabolism are associated with hepatic metabolic disorders. Elevated hepatic acetate concentrations, often attributed to high caloric intake, are recognized as a pivotal factor in the etiology of obesity and metabolic syndrome. Therefore, the assessment of acetate breakdown and TCA cycle activity plays a central role in understanding the impact of diet‐induced alterations on liver metabolism. Magnetic resonance‐based deuterium metabolic imaging (DMI) could help to unravel the underlying mechanisms involved in disease development and progression, however, the application of conventional deuterated glucose does not lead to substantial enrichment in hepatic glutamine and glutamate. This study aimed to demonstrate the feasibility of DMI for tracking deuterated acetate breakdown via the TCA cycle in lean and diet‐induced fatty liver (FL) rats using 3D DMI after an intraperitoneal infusion of sodium acetate‐d3 at 9.4T. Localized and nonlocalized liver spectra acquired at 10 time points post‐injection over a 130‐min study revealed similar intrahepatic acetate uptake in both animal groups (AUCFL = 717.9 ± 131.1 mM▯min−1, AUClean = 605.1 ± 119.9 mM▯min−1, p = 0.62). Metabolic breakdown could be observed in both groups with an emerging glutamine/glutamate (Glx) peak as a downstream metabolic product (AUCFL = 113.6 ± 23.8 mM▯min−1, AUClean = 136.7 ± 41.7 mM▯min−1, p = 0.68).This study showed the viability of DMI for tracking substrate flux through the TCA cycle, underscoring its methodological potential for imaging metabolic processes in the body.
- 4 August 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (11) , e5008
Quantification of short echo time MRS signals with improved version of QUantitation based on quantum ESTimation algorithm
Magnetic resonance spectroscopy offers information about metabolite changes in the organism, which can be used in diagnosis. While short echo time proton spectra exhibit more distinguishable metabolites compared with proton spectra acquired with long echo times, their quantification (and providing estimates of metabolite concentrations) is more challenging. They are hampered by a background signal, which originates mainly from macromolecules (MM) and mobile lipids. An improved version of the quantification algorithm QUantitation based on quantum ESTimation (QUEST), with MM prior knowledge (QUEST‐MM), dedicated to proton signals and invoking appropriate prior knowledge on MM, is proposed and tested. From a single acquisition, it enables better metabolite quantification, automatic estimation of the background, and additional automatic quantification of MM components, thus improving its applicability in the clinic. The proposed algorithm may facilitate studies that involve patients with pathological MM in the brain. QUEST‐MM and three QUEST‐based strategies for quantifying short echo time signals are compared in terms of bias‐variance trade‐off and Cramér–Rao lower bound estimates. The performances of the methods are evaluated through extensive Monte Carlo studies. In particular, the histograms of the metabolite and MM amplitude distributions demonstrate the performances of the estimators. They showed that QUEST‐MM works better than QUEST (Subtract approach) and is a good alternative to QUEST when measured MM signal is unavailable or unsuitable. Quantification with QUEST‐MM is shown for 1H in vivo rat brain signals obtained with the SPECIAL pulse sequence at 9.4 T, and human brain signals obtained, respectively, with STEAM at 4 T and PRESS at 3 T. QUEST‐MM is implemented in jMRUI and will be available for public use from version 7.1.
- 4 August 2023
- Published by Wiley in NMR in Biomedicine
- Vol. 36 (11) , e5008
Quantification of short echo time MRS signals with improved version of QUantitation based on quantum ESTimation algorithm
Magnetic resonance spectroscopy offers information about metabolite changes in the organism, which can be used in diagnosis. While short echo time proton spectra exhibit more distinguishable metabolites compared with proton spectra acquired with long echo times, their quantification (and providing estimates of metabolite concentrations) is more challenging. They are hampered by a background signal, which originates mainly from macromolecules (MM) and mobile lipids. An improved version of the quantification algorithm QUantitation based on quantum ESTimation (QUEST), with MM prior knowledge (QUEST‐MM), dedicated to proton signals and invoking appropriate prior knowledge on MM, is proposed and tested. From a single acquisition, it enables better metabolite quantification, automatic estimation of the background, and additional automatic quantification of MM components, thus improving its applicability in the clinic. The proposed algorithm may facilitate studies that involve patients with pathological MM in the brain. QUEST‐MM and three QUEST‐based strategies for quantifying short echo time signals are compared in terms of bias‐variance trade‐off and Cramér–Rao lower bound estimates. The performances of the methods are evaluated through extensive Monte Carlo studies. In particular, the histograms of the metabolite and MM amplitude distributions demonstrate the performances of the estimators. They showed that QUEST‐MM works better than QUEST (Subtract approach) and is a good alternative to QUEST when measured MM signal is unavailable or unsuitable. Quantification with QUEST‐MM is shown for 1H in vivo rat brain signals obtained with the SPECIAL pulse sequence at 9.4 T, and human brain signals obtained, respectively, with STEAM at 4 T and PRESS at 3 T. QUEST‐MM is implemented in jMRUI and will be available for public use from version 7.1.
- Open Access
- 5 April 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 158, 106837
Physics-informed deep learning approach to quantification of human brain metabolites from magnetic resonance spectroscopy data
- 5 April 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 158, 106837
Open AccessPhysics-informed deep learning approach to quantification of human brain metabolites from magnetic resonance spectroscopy data
- Open Access
- 11 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1221-1236
Model‐informed unsupervised deep learning approaches to frequency and phase correction of MRS signals
Purpose: A supervised deep learning (DL) approach for frequency and phase correction (FPC) of MRS data recently showed encouraging results, but obtaining transients with labels for supervised learning is challenging. This work investigates the feasibility and efficiency of unsupervised deep learning–based FPC.Methods: Two novel deep learning–based FPC methods (deep learning–based Cr referencing and deep learning–based spectral registration), which use a priori physics domain knowledge, are presented. The proposed networks were trained, validated, and evaluated using simulated, phantom, and publicly accessible in vivo MEGA‐edited MRS data. The performance of our proposed FPC methods was compared with other generally used FPC methods, in terms of precision and time efficiency. A new measure was proposed in this study to evaluate the FPC method performance. The ability of each of our methods to carry out FPC at varying SNR levels was evaluated. A Monte Carlo study was carried out to investigate the performance of our proposed methods.Results: The validation using low‐SNR manipulated simulated data demonstrated that the proposed methods could perform FPC comparably with other methods. The evaluation showed that the deep learning–based spectral registration over a limited frequency range method achieved the highest performance in phantom data. The applicability of the proposed method for FPC of GABA‐edited in vivo MRS data was demonstrated. Our proposed networks have the potential to reduce computation time significantly.Conclusions: The proposed physics‐informed deep neural networks trained in an unsupervised manner with complex data can offer efficient FPC of large MRS data in a shorter time.
- 11 November 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (3) , 1221-1236
Open AccessModel‐informed unsupervised deep learning approaches to frequency and phase correction of MRS signals
Purpose: A supervised deep learning (DL) approach for frequency and phase correction (FPC) of MRS data recently showed encouraging results, but obtaining transients with labels for supervised learning is challenging. This work investigates the feasibility and efficiency of unsupervised deep learning–based FPC.Methods: Two novel deep learning–based FPC methods (deep learning–based Cr referencing and deep learning–based spectral registration), which use a priori physics domain knowledge, are presented. The proposed networks were trained, validated, and evaluated using simulated, phantom, and publicly accessible in vivo MEGA‐edited MRS data. The performance of our proposed FPC methods was compared with other generally used FPC methods, in terms of precision and time efficiency. A new measure was proposed in this study to evaluate the FPC method performance. The ability of each of our methods to carry out FPC at varying SNR levels was evaluated. A Monte Carlo study was carried out to investigate the performance of our proposed methods.Results: The validation using low‐SNR manipulated simulated data demonstrated that the proposed methods could perform FPC comparably with other methods. The evaluation showed that the deep learning–based spectral registration over a limited frequency range method achieved the highest performance in phantom data. The applicability of the proposed method for FPC of GABA‐edited in vivo MRS data was demonstrated. Our proposed networks have the potential to reduce computation time significantly.Conclusions: The proposed physics‐informed deep neural networks trained in an unsupervised manner with complex data can offer efficient FPC of large MRS data in a shorter time.
- Open Access
Physics-informed Deep Learning Approach to Quantification of Human Brain Metabolites from Magnetic Resonance Spectroscopy Data
Purpose While the recommended analysis method for magnetic resonance spectroscopy data is linear combination model (LCM) fitting, the supervised deep learning (DL) approach for quantification of MR spectroscopy (MRS) data recently showed encouraging results; however, supervised learning requires ground truth fitted spectra, which is not practical. This work investigates the feasibility and efficiency of the LCM-based self-supervised DL method for the analysis of MRS data. Method We present a novel DL-based method for the quantification of relative metabolite concentrations, using quantum-mechanics simulated metabolite responses and neural networks. We trained, validated, and evaluated the proposed networks with simulated and publicly accessible in-vivo human brain MRS data and compared the performance with traditional methods. A novel adaptive macromolecule fitting algorithm is included. We investigated the performance of the proposed methods in a Monte Carlo (MC) study. Result The validation using low-SNR simulated data demonstrated that the proposed methods could perform quantification comparably to other methods. The applicability of the proposed method for the quantification of in-vivo MRS data was demonstrated. Our proposed networks have the potential to reduce computation time significantly. Conclusion The proposed model-constrained deep neural networks trained in a self-supervised manner with complex data can offer fast and efficient quantification of MRS data. Highlights A novel self-supervised deep learning method for quantifying metabolite concentrations in MR spectroscopy signals. Providing a unique opportunity to quantify complex-valued MRS data in the time domain. Quantifying MR spectroscopy signals with comparable performance to traditional methods in a significantly shorter amount of time. Investigating the impacts of the dataset size and neural network design on our proposed model
Open AccessPhysics-informed Deep Learning Approach to Quantification of Human Brain Metabolites from Magnetic Resonance Spectroscopy Data
Purpose While the recommended analysis method for magnetic resonance spectroscopy data is linear combination model (LCM) fitting, the supervised deep learning (DL) approach for quantification of MR spectroscopy (MRS) data recently showed encouraging results; however, supervised learning requires ground truth fitted spectra, which is not practical. This work investigates the feasibility and efficiency of the LCM-based self-supervised DL method for the analysis of MRS data. Method We present a novel DL-based method for the quantification of relative metabolite concentrations, using quantum-mechanics simulated metabolite responses and neural networks. We trained, validated, and evaluated the proposed networks with simulated and publicly accessible in-vivo human brain MRS data and compared the performance with traditional methods. A novel adaptive macromolecule fitting algorithm is included. We investigated the performance of the proposed methods in a Monte Carlo (MC) study. Result The validation using low-SNR simulated data demonstrated that the proposed methods could perform quantification comparably to other methods. The applicability of the proposed method for the quantification of in-vivo MRS data was demonstrated. Our proposed networks have the potential to reduce computation time significantly. Conclusion The proposed model-constrained deep neural networks trained in a self-supervised manner with complex data can offer fast and efficient quantification of MRS data. Highlights A novel self-supervised deep learning method for quantifying metabolite concentrations in MR spectroscopy signals. Providing a unique opportunity to quantify complex-valued MRS data in the time domain. Quantifying MR spectroscopy signals with comparable performance to traditional methods in a significantly shorter amount of time. Investigating the impacts of the dataset size and neural network design on our proposed model
- 28 September 2022
- Published by Taylor & Francis in The World Journal of Biological Psychiatry
- Vol. 24 (5) , 414-428
Laterality in functional and metabolic state of the bulbectomised rat brain detected by ASL and 1H MRS: A pilot study
Pilot study validating the animal model of depression – the bilateral olfactory bulbectomy in rats – by two nuclear magnetic resonance methods, indirectly detecting the metabolic state of the brain...
- 28 September 2022
- Published by Taylor & Francis in The World Journal of Biological Psychiatry
- Vol. 24 (5) , 414-428
Laterality in functional and metabolic state of the bulbectomised rat brain detected by ASL and 1H MRS: A pilot study
Pilot study validating the animal model of depression – the bilateral olfactory bulbectomy in rats – by two nuclear magnetic resonance methods, indirectly detecting the metabolic state of the brain...
- Open Access
Model-Informed Unsupervised Deep Learning Approaches to Frequency and Phase Correction of MRS Signals
Purpose A supervised deep learning (DL) approach for frequency-and-phase Correction (FPC) of MR spectroscopy (MRS) data recently showed encouraging results, but obtaining transients with labels for supervised learning is challenging. This work investigates the feasibility and efficiency of unsupervised DL-based FPC. Method Two novel DL-based FPC methods (deep learning-based Cr referencing [dCrR] and deep learning-based spectral registration [dSR]) which use a priori physics domain knowledge are presented. The proposed networks were trained, validated, and evaluated using simulated, phantom, and publicly accessible in-vivo MEGA-edited MRS data. The performance of our proposed FPC methods was compared to other generally used FPC methods, in terms of precision and time efficiency. A new measure was proposed in this study to evaluate the FPC method performance. The ability of each of our methods to carry out FPC at varying SNR levels was evaluated. A Monte Carlo (MC) study was carried out to investigate the performance of our proposed methods. Result The validation using low-SNR manipulated simulated data demonstrated that the proposed methods could perform FPC comparably to other methods. The evaluation showed that the dCrR method achieved the highest performance in phantom data. The applicability of the proposed method for FPC of GABA-edited in-vivo MRS data was demonstrated. Our proposed networks have the potential to reduce computation time significantly. Conclusion The proposed physics-informed deep neural networks trained in an unsupervised manner with complex data can offer efficient FPC of MRS data in a shorter time.
Open AccessModel-Informed Unsupervised Deep Learning Approaches to Frequency and Phase Correction of MRS Signals
Purpose A supervised deep learning (DL) approach for frequency-and-phase Correction (FPC) of MR spectroscopy (MRS) data recently showed encouraging results, but obtaining transients with labels for supervised learning is challenging. This work investigates the feasibility and efficiency of unsupervised DL-based FPC. Method Two novel DL-based FPC methods (deep learning-based Cr referencing [dCrR] and deep learning-based spectral registration [dSR]) which use a priori physics domain knowledge are presented. The proposed networks were trained, validated, and evaluated using simulated, phantom, and publicly accessible in-vivo MEGA-edited MRS data. The performance of our proposed FPC methods was compared to other generally used FPC methods, in terms of precision and time efficiency. A new measure was proposed in this study to evaluate the FPC method performance. The ability of each of our methods to carry out FPC at varying SNR levels was evaluated. A Monte Carlo (MC) study was carried out to investigate the performance of our proposed methods. Result The validation using low-SNR manipulated simulated data demonstrated that the proposed methods could perform FPC comparably to other methods. The evaluation showed that the dCrR method achieved the highest performance in phantom data. The applicability of the proposed method for FPC of GABA-edited in-vivo MRS data was demonstrated. Our proposed networks have the potential to reduce computation time significantly. Conclusion The proposed physics-informed deep neural networks trained in an unsupervised manner with complex data can offer efficient FPC of MRS data in a shorter time.
- Open Access
- 15 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2384-2401
In vivo macromolecule signals in rat brain 1H‐MR spectra at 9.4T: Parametrization, spline baseline estimation, and T2 relaxation times
Purpose: Reliable detection and fitting of macromolecules (MM) are crucial for accurate quantification of brain short‐echo time (TE) 1H‐MR spectra. An experimentally acquired single MM spectrum is commonly used. Higher spectral resolution at ultra‐high field (UHF) led to increased interest in using a parametrized MM spectrum together with flexible spline baselines to address unpredicted spectroscopic components. Herein, we aimed to: (1) implement an advanced methodological approach for post‐processing, fitting, and parametrization of 9.4T rat brain MM spectra; (2) assess the concomitant impact of the LCModel baseline and MM model (ie, single vs parametrized); and (3) estimate the apparent T2 relaxation times for seven MM components.Methods: A single inversion recovery sequence combined with advanced AMARES prior knowledge was used to eliminate the metabolite residuals, fit, and parametrize 10 MM components directly from 9.4T rat brain in vivo 1H‐MR spectra at different TEs. Monte Carlo simulations were also used to assess the concomitant influence of parametrized MM and DKNTMN parameter in LCModel.Results: A very stiff baseline (DKNTMN ≥ 1 ppm) in combination with a single MM spectrum led to deviations in metabolite concentrations. For some metabolites the parametrized MM showed deviations from the ground truth for all DKNTMN values. Adding prior knowledge on parametrized MM improved MM and metabolite quantification. The apparent T2 ranged between 12 and 24 ms for seven MM peaks.Conclusion: Moderate flexibility in the spline baseline was required for reliable quantification of real/experimental spectra based on in vivo and Monte Carlo data. Prior knowledge on parametrized MM improved MM and metabolite quantification.
- 15 July 2021
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 86 (5) , 2384-2401
Open AccessIn vivo macromolecule signals in rat brain 1H‐MR spectra at 9.4T: Parametrization, spline baseline estimation, and T2 relaxation times
Purpose: Reliable detection and fitting of macromolecules (MM) are crucial for accurate quantification of brain short‐echo time (TE) 1H‐MR spectra. An experimentally acquired single MM spectrum is commonly used. Higher spectral resolution at ultra‐high field (UHF) led to increased interest in using a parametrized MM spectrum together with flexible spline baselines to address unpredicted spectroscopic components. Herein, we aimed to: (1) implement an advanced methodological approach for post‐processing, fitting, and parametrization of 9.4T rat brain MM spectra; (2) assess the concomitant impact of the LCModel baseline and MM model (ie, single vs parametrized); and (3) estimate the apparent T2 relaxation times for seven MM components.Methods: A single inversion recovery sequence combined with advanced AMARES prior knowledge was used to eliminate the metabolite residuals, fit, and parametrize 10 MM components directly from 9.4T rat brain in vivo 1H‐MR spectra at different TEs. Monte Carlo simulations were also used to assess the concomitant influence of parametrized MM and DKNTMN parameter in LCModel.Results: A very stiff baseline (DKNTMN ≥ 1 ppm) in combination with a single MM spectrum led to deviations in metabolite concentrations. For some metabolites the parametrized MM showed deviations from the ground truth for all DKNTMN values. Adding prior knowledge on parametrized MM improved MM and metabolite quantification. The apparent T2 ranged between 12 and 24 ms for seven MM peaks.Conclusion: Moderate flexibility in the spline baseline was required for reliable quantification of real/experimental spectra based on in vivo and Monte Carlo data. Prior knowledge on parametrized MM improved MM and metabolite quantification.
- Open Access
- 1 January 2021
- Published by INSTICC
- p. 268-275
A Wavelet Scattering Convolutional Network for Magnetic Resonance Spectroscopy Signal Quantitation
- 1 January 2021
- Published by INSTICC
- p. 268-275
Open AccessA Wavelet Scattering Convolutional Network for Magnetic Resonance Spectroscopy Signal Quantitation