Beilei Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Beilei Yang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhang
School of Information Science and Technology, Fudan University, Shanghai 200438, China
3 shared publications - Ke Chen
Jiangnan University
3 shared publications - Min Guo
Shaoxing University
3 shared publications - Zhenfeng Gong
Dalian University of Technology
3 shared publications - Chenyang Li
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, China
2 shared publications - Fengxiang Ma
Electric Power Research Institute of State Grid Anhui Electric Power Company, Ltd., Hefei, China
2 shared publications
Latest Publications
- 5 November 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 473
Compact acoustic-compliance-enhanced fiber-optic photoacoustic dual-gas sensor
- 5 November 2026
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 473
Compact acoustic-compliance-enhanced fiber-optic photoacoustic dual-gas sensor
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Highly Sensitive Optical Fiber Photoacoustic Sensor for In Situ Detection of Dissolved Gas in Oil
A highly sensitive optical fiber photoacoustic (PA) sensor was proposed and demonstrated for in situ detection of dissolved gas in oil. Two optical fibers were used for the transmission of pump light and probe light, respectively. The miniature detection module integrated by optical fiber sensor and oil–gas separation membrane made it passive and anti-electromagnetic interference. The dissolved gas in oil passed through the organic membrane into the micro-chamber of the PA sensor. The PA signal generated by the gas absorption of laser energy was detected by a Fabry–Perot interferometric cantilever. To reduce the equilibrium time of oil–gas separation and improve the PA response, structural parameters of the sensor were optimized. The experimental results showed that the temperature had an influence on the response time and PA response. The response time was ~1.8 h at 50 °C. To realize temperature compensation, the temperature was measured simultaneously by averaging the measured Fabry–Perot cavity length. In addition, the detection limit of dissolved acetylene (C 2 H 2 ) gas reached $0.5~\mu \text{L}$ /L. Since oil pumping was not required and the oil did not contact with the ambient air, the oil was not polluted and consumed to achieve in situ measurement.
- 5 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Highly Sensitive Optical Fiber Photoacoustic Sensor for In Situ Detection of Dissolved Gas in Oil
A highly sensitive optical fiber photoacoustic (PA) sensor was proposed and demonstrated for in situ detection of dissolved gas in oil. Two optical fibers were used for the transmission of pump light and probe light, respectively. The miniature detection module integrated by optical fiber sensor and oil–gas separation membrane made it passive and anti-electromagnetic interference. The dissolved gas in oil passed through the organic membrane into the micro-chamber of the PA sensor. The PA signal generated by the gas absorption of laser energy was detected by a Fabry–Perot interferometric cantilever. To reduce the equilibrium time of oil–gas separation and improve the PA response, structural parameters of the sensor were optimized. The experimental results showed that the temperature had an influence on the response time and PA response. The response time was ~1.8 h at 50 °C. To realize temperature compensation, the temperature was measured simultaneously by averaging the measured Fabry–Perot cavity length. In addition, the detection limit of dissolved acetylene (C 2 H 2 ) gas reached $0.5~\mu \text{L}$ /L. Since oil pumping was not required and the oil did not contact with the ambient air, the oil was not polluted and consumed to achieve in situ measurement.
- 2 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Ultrahigh Sensitivity Fiber-Optic Fabry–Perot Interferometric Acoustic Sensor Based on Silicon Cantilever
Detection of weak acoustic signals is of great significance. To achieve ultrahigh sensitivity acoustic detection, a silicon cantilever-based fiber-optic acoustic sensor (FOAS) formed by a Fabry–Perot interferometric structure is proposed in this work. Theoretical analysis and finite element analysis are used to assist the sensor design. The cantilever is fabricated by the microelectro-mechanical system (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. A white light interference (WLI) demodulation system based on an amplified spontaneous emission (ASE) source is used to demodulate the cavity length of the sensor. The acoustic pressure sensitivity of the sensor was measured to be $1.753~\mu \text{m}$ /Pa at a frequency of 1 kHz and $28.75~\mu \text{m}$ /Pa at the resonance frequency of the cantilever. Experimental results indicated that the minimum detectable pressure (MDP) level of the fabricated sensor was $0.21~\mu $ Pa/Hz 1/2 at 1 kHz, which is the lowest reported value. The silicon-based FOAS proposed in this article demonstrates its ability to detect ultraweak acoustic signals due to its extremely high sensitivity.
- 2 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-8
Ultrahigh Sensitivity Fiber-Optic Fabry–Perot Interferometric Acoustic Sensor Based on Silicon Cantilever
Detection of weak acoustic signals is of great significance. To achieve ultrahigh sensitivity acoustic detection, a silicon cantilever-based fiber-optic acoustic sensor (FOAS) formed by a Fabry–Perot interferometric structure is proposed in this work. Theoretical analysis and finite element analysis are used to assist the sensor design. The cantilever is fabricated by the microelectro-mechanical system (MEMS) processing technology on a silicon-on-insulator (SOI) wafer. A white light interference (WLI) demodulation system based on an amplified spontaneous emission (ASE) source is used to demodulate the cavity length of the sensor. The acoustic pressure sensitivity of the sensor was measured to be $1.753~\mu \text{m}$ /Pa at a frequency of 1 kHz and $28.75~\mu \text{m}$ /Pa at the resonance frequency of the cantilever. Experimental results indicated that the minimum detectable pressure (MDP) level of the fabricated sensor was $0.21~\mu $ Pa/Hz 1/2 at 1 kHz, which is the lowest reported value. The silicon-based FOAS proposed in this article demonstrates its ability to detect ultraweak acoustic signals due to its extremely high sensitivity.
- 8 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (10) , 8486-8493
All-Optical Photoacoustic Multigas Analyzer Using Digital Fiber-Optic Acoustic Detector
We present an all-optical photoacoustic (PA) multi-gas analyzer by using a digital fiber-optic acoustic detector, which consists of a spectrum demodulation based fiber Fabry-Perot (F-P) pressure sensor and a digital virtual lock-in amplifier. The concentration of multi-gas is quantified by using an intensity modulated infrared thermal source and two wavelength modulated laser diodes. Light beams from the three sources are coupled to a single nonresonant PA cell. The generated PA pressure is detected by the fiber F-P pressure sensor, which is demodulated through a near-infrared spectrometer. A lock-in white-light interferometer is developed for detecting first-harmonic (1f) and second-harmonic (2f) signals. The noise equivalent detection limits with a 100-s averaging time are 37 ppb, 9 ppb, 6 ppb, 17 ppb, 4 ppb and 60 ppb for CH4, C2H2, C2H4, C2H6, CO and CO2, respectively.
- 8 May 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (10) , 8486-8493
All-Optical Photoacoustic Multigas Analyzer Using Digital Fiber-Optic Acoustic Detector
We present an all-optical photoacoustic (PA) multi-gas analyzer by using a digital fiber-optic acoustic detector, which consists of a spectrum demodulation based fiber Fabry-Perot (F-P) pressure sensor and a digital virtual lock-in amplifier. The concentration of multi-gas is quantified by using an intensity modulated infrared thermal source and two wavelength modulated laser diodes. Light beams from the three sources are coupled to a single nonresonant PA cell. The generated PA pressure is detected by the fiber F-P pressure sensor, which is demodulated through a near-infrared spectrometer. A lock-in white-light interferometer is developed for detecting first-harmonic (1f) and second-harmonic (2f) signals. The noise equivalent detection limits with a 100-s averaging time are 37 ppb, 9 ppb, 6 ppb, 17 ppb, 4 ppb and 60 ppb for CH4, C2H2, C2H4, C2H6, CO and CO2, respectively.