XZXuechen Zhou

Xuechen Zhou

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuechen Zhou has a total of 37 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Substantially Improved Microbial Electrosynthesis of Methane Achieved by Improving Hydrogen Retention and Flow Distribution through Porous Electrodes

    by Bin Bian, Najiaowa Yu, Nakyeong Yun, Sen Li, Xuechen Zhou, Chenghan Xie, Ruggero Rossi, Bruce E. Logan

    Efficient hydrogen utilization by microorganisms is crucial for improving the energy-to-chemical efficiency in microbial electrosynthesis (MES). We therefore developed a new rectangular zero-gap cell design featuring an extended flow path to improve hydrogen retention and conversion to biomethane. Multiphase flow modeling within porous carbon felt cathodes revealed the new configuration with a trapezoidal inlet substantially reduced flow dead zones and tripled hydrogen retention time versus circular cells. At -1 V vs Ag/AgCl, increasing catholyte flow rate from 0.8 to 2.5 mL/min raised current densities from 19 to 24 A/m2 (30 °C), reaching a peak Coulombic efficiency (CE) of 82% for methane production (7.0 L/L-d). Further increasing the flow rate to 7.5 mL/min or temperature to 37 °C slightly improved methane production (7.2-7.7 L/L-d) but reduced hydrogen retention in cells based on modeling results, lowering CEs and energy efficiencies due to unreacted hydrogen. Matching cathode potential to flow rates and temperatures could balance H2 production and retention, significantly improving CE to 96% toward 7.5 L/L-d methane production with a high energy efficiency of 36% (-0.95 V vs Ag/AgCl, 37 °C). These findings underscore the importance of improving flow distribution and hydrogen retention within zero-gap MES cells to enhance energy and Coulombic efficiencies.


  • Modeling Ion Transport across Thin-Film Composite Membranes During Saltwater Electrolysis

    by Rachel F. Taylor, Xuechen Zhou, Chenghan Xie, Fernan Martinez, Xinran Zhang, Bastiaan Blankert, Cristian Picioreanu, Bruce E. Logan

    Affordable thin-film composite (TFC) membranes are a potential alternative to more expensive ion exchange membranes in saltwater electrolyzers used for hydrogen gas production. We used a solution-friction transport model to study how the induced potential gradient controls ion transport across the polyamide (PA) active layer and support layers of TFC membranes during electrolysis. The set of parameters was simplified by assigning the same size-related partition and friction coefficients for all salt ions through the membrane active layer. The model was fit to experimental ion transport data from saltwater electrolysis with 600 mM electrolytes at a current density of 10 mA cm-2. When the electrolyte concentration and current density were increased, the transport of major charge carriers was successfully predicted by the model. Ion transport calculated using the model only minimally changed when the negative active layer charge density was varied from 0 to 600 mM, indicating active layer charge was not largely responsible for controlling ion crossover during electrolysis. Based on model simulations, a sharp pH gradient was predicted to occur within the supporting layer of the membrane. These results can help guide membrane design and operation conditions in water electrolyzers using TFC membranes.


  • Using a non-precious metal catalyst for long-term enhancement of methane production in a zero-gap microbial electrosynthesis cell

    by Bin Bian, Najiaowa Yu, Amir Akbari, Le Shi, Xuechen Zhou, Chenghan Xie, Pascal E. Saikaly, Bruce E. Logan


  • Thin-Film Composite Membranes for Hydrogen Evolution with a Saline Catholyte Water Feed

    by Le Shi, Xuechen Zhou, Rachel F. Taylor, Chenghan Xie, Bin Bian, Derek M. Hall, Ruggero Rossi, Michael A. Hickner, Christopher A. Gorski, Bruce E. Logan

    Hydrogen gas evolution using an impure or saline water feed is a promising strategy to reduce overall energy consumption and investment costs for on-site, large-scale production using renewable energy sources. The chlorine evolution reaction is one of the biggest concerns in hydrogen evolution with impure water feeds. The "alkaline design criterion" in impure water electrolysis was examined here because water oxidation catalysts can exhibit a larger kinetic overpotential without interfering chlorine chemistry under alkaline conditions. Here, we demonstrated that relatively inexpensive thin-film composite (TFC) membranes, currently used for high-pressure reverse osmosis (RO) desalination applications, can have much higher rejection of Cl- (total crossover of 2.9 +/- 0.9 mmol) than an anion-exchange membrane (AEM) (51.8 +/- 2.3 mmol) with electrolytes of 0.5 M KOH for the anolyte and 0.5 M NaCl for the catholyte with a constant current (100 mA/cm(2) for 20 h). The membrane resistances, which were similar for the TFC membrane and the AEM based on electrochemical impedance spectroscopy (EIS) and Ohm's law methods, could be further reduced by increasing the electrolyte concentration or removal of the structural polyester supporting layer (TFC-no PET). TFC membranes could enable pressurized gas production, as this membrane was demonstrated to be mechanically stable with no change in permeate flux at 35 bar. These results show that TFC membranes provide a novel pathway for producing green hydrogen with a saline water feed at elevated pressures compared to systems using AEMs or porous diaphragms.


  • Rapid, Selective, and Chemical-Free Removal of Dissolved Silica from Water via Electrosorption: Feasibility and Mechanisms

    by Wen Ma, Sohum K. Patel, Mariana Marcos−Hernández, Xiaoxiong Wang, Xuechen Zhou, Weiyi Pan, Yonguk Shin, Dino Villagrán, Menachem Elimelech

    The unavoidable and detrimental formation of silica scale in engineered processes necessitates the urgent development of effective, economic, and sustainable strategies for dissolved silica removal from water. Herein, we demonstrate a rapid, chemical-free, and selective silica removal method using electrosorption. Specifically, we confirm the feasibility of exploiting local pH dynamics at the electrodes in flow-through electrosorption, achieved through a counterintuitive cell configuration design, to induce ionization and concomitant electrosorption of dissolved silica. In addition, to improve the feasibility of silica electrosorption under high-salinity solutions, we developed a silica-selective anode by functionalizing porous activated carbon cloths with aluminum hydroxide nanoparticles (Al(OH)3-p-ACC). The modification markedly enhances silica sorption capacity (2.8 vs 1.1 mgsilica ganode-1) and reduces the specific energy consumption (13.3 vs 19.8 kWh kgsilica-1). Notably, the modified electrode retains remarkable silica sorption capacity even in the presence of high concentrations of co-occurring ions (up to 100 mM NaCl). The mechanisms underlying the superior silica removal stability and selectivity with the Al(OH)3-p-ACC electrode are also elucidated, revealing a synergistic interaction involving outer-sphere and inner-sphere complexation between dissolved silica and Al(OH)3 nanoparticles on the electrodes. Moreover, we find that effective regeneration of the electrodes may be achieved by applying a reverse potential during discharge, although complete regeneration of the modified electrodes may necessitate alternative materials or process optimization. We recommend the adoption of feedwater-specific designs for the development of future silica-selective electrodes in electrosorption capable of meeting silica removal demands across a wide range of engineered systems.


  • Reducing Chloride Ion Permeation during Seawater Electrolysis Using Double-Polyamide Thin-Film Composite Membranes

    by Xuechen Zhou, Rachel F. Taylor, Le Shi, Chenghan Xie, Bin Bian, Bruce E. Logan

    Low-cost polyamide thin-film composite membranes are being explored as alternatives to expensive cation exchange membranes for seawater electrolysis. However, transport of chloride from seawater to the anode chamber must be reduced to minimize the production of chlorine gas. A double-polyamide composite structure was created that reduced the level of chloride transport. Adding five polyamide layers on the back of a conventional polyamide composite membrane reduced the chloride ion transport by 53% and did not increase the applied voltage. Decreased chloride permeation was attributed to enhanced electrostatic and steric repulsion created by the new polyamide layers. Charge was balanced through increased sodium ion transport (52%) from the anolyte to the catholyte rather than through a change in the transport of protons and hydroxides. As a result, the Nernstian loss arising from the pH difference between the anolyte and catholyte remained relatively constant during electrolysis despite membrane modifications. This lack of a change in pH showed that transport of protons and hydroxides during electrolysis was independent of salt ion transport. Therefore, only sodium ion transport could compensate for the reduction of chloride flux to maintain the set current. Overall, these results prove the feasibility of using a double-polyamide structure to control chloride permeation during seawater electrolysis without sacrificing energy consumption.


  • Relative Insignificance of Polyamide Layer Selectivity for Seawater Electrolysis Applications

    by Xuechen Zhou, Le Shi, Rachel F. Taylor, Chenghan Xie, Bin Bian, Cristian Picioreanu, Bruce E. Logan

    Low-cost polyamide thin-film composite (TFC) membranes are being explored as alternatives to cation exchange membranes for seawater electrolysis. An optimal membrane should have a low electrical resistance to minimize applied potentials needed for water electrolysis and be able to block chloride ions present in a seawater catholyte from reaching the anode. The largest energy loss associated with a TFC membrane was the Nernstian overpotential of 0.74 V (equivalent to 37 Ω cm2 at 20 mA cm-2), derived from the pH difference between the anolyte and catholyte and not the membrane ohmic overpotential. Based on analysis using electrochemical impedance spectroscopy, the pristine TFC membrane contributed only 5.00 Ω cm2 to the ohmic resistance. Removing the polyester support layer reduced the resistance by 79% to only 1.04 Ω cm2, without altering the salt ion transport between the electrolytes. Enlarging the pore size (∼5 times) in the polyamide active layer minimally impacted counterion transport across the membrane during electrolysis, but it increased the total concentration of chloride transported by 60%. Overall, this study suggests that TFC membranes with thinner but mechanically strong supporting layers and size-selective active layers should reduce energy consumption and the potential for chlorine generation for seawater electrolyzers.


  • Top Cited Papers
    Open Access

    Intrapore energy barriers govern ion transport and selectivity of desalination membranes

    by Xuechen Zhou, Zhangxin Wang, Razi Epsztein, Cheng Zhan, Wenlu Li, John D. Fortner, Tuan Anh Pham, Jae-Hong Kim, Menachem Elimelech

    A fundamental study elucidates the mechanisms underlying selective ion transport through desalination membranes.