Kathryn Cooper
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kathryn Cooper has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Saami K. Yazdani
Department of Engineering, Wake Forest University, Winston-Salem, NC, USA
2 shared publications - Alyssa Lloret
Department of Engineering, Wake Forest University, Winston-Salem, NC 27101, USA
1 shared publication Claire V. Cawthon
Mechanical Engineering Department, University of South Alabama, Mobile, AL, United States
1 shared publication- Claire V. Cawthon
Department of Mechanical Engineering, University of South Alabama, Mobile, AL 36688, USA
1 shared publication - Clifton Huett
Department of Mechanical Engineering, University of South Alabama, Mobile, AL 36688, USA
1 shared publication Emily Goel
Mechanical Engineering Department, University of South Alabama, Mobile, AL, United States
1 shared publication
Latest Publications
- Open Access
- 10 June 2021
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 3, 675188
The Development of an ex vivo Flow System to Assess Acute Arterial Drug Retention of Cardiovascular Intravascular Devices
Purpose: The goal of this study was to develop an ex vivo system capable of rapidly evaluating arterial drug levels in living, isolated porcine carotid arteries.Methods: A vascular bioreactor system was developed that housed a native porcine carotid artery under physiological flow conditions. The ex vivo bioreactor system was designed to quantify the acute drug transfer of catheter-based drug delivery devices into explanted carotid arteries. To evaluate our ex vivo system, a paclitaxel-coated balloon and a perfusion catheter device delivering liquid paclitaxel were utilized. At 1-h post-drug delivery, arteries were removed, and paclitaxel drug levels measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Parallel experiments were performed in a pig model to validate ex vivo measurements.Results: LC-MS/MS analysis demonstrated arterial paclitaxel levels of the drug-coated balloon-treated arteries to be 48.49 ± 24.09 ng/mg and the perfusion catheter-treated arteries to be 25.42 ± 9.74 ng/mg at 1 h in the ex vivo system. Similar results were measured in vivo, as arterial paclitaxel concentrations were measured at 59.23 ± 41.27 ng/mg for the drug-coated balloon-treated arteries and 23.43 ± 20.23 ng/mg for the perfusion catheter-treated arteries. Overall, no significant differences were observed between paclitaxel measurements of arteries treated ex vivo vs. in vivo.Conclusion: This system represents the first validated ex vivo pulsatile system to determine pharmacokinetics in a native blood vessel. This work provides proof-of-concept of a quick, inexpensive, preclinical tool to study acute drug tissue concentration kinetics of drug-releasing interventional vascular devices.
- 10 June 2021
- Published by Frontiers Media SA in Frontiers in Medical Technology
- Vol. 3, 675188
Open AccessThe Development of an ex vivo Flow System to Assess Acute Arterial Drug Retention of Cardiovascular Intravascular Devices
Purpose: The goal of this study was to develop an ex vivo system capable of rapidly evaluating arterial drug levels in living, isolated porcine carotid arteries.Methods: A vascular bioreactor system was developed that housed a native porcine carotid artery under physiological flow conditions. The ex vivo bioreactor system was designed to quantify the acute drug transfer of catheter-based drug delivery devices into explanted carotid arteries. To evaluate our ex vivo system, a paclitaxel-coated balloon and a perfusion catheter device delivering liquid paclitaxel were utilized. At 1-h post-drug delivery, arteries were removed, and paclitaxel drug levels measured using liquid chromatography-tandem mass spectrometry (LC-MS/MS). Parallel experiments were performed in a pig model to validate ex vivo measurements.Results: LC-MS/MS analysis demonstrated arterial paclitaxel levels of the drug-coated balloon-treated arteries to be 48.49 ± 24.09 ng/mg and the perfusion catheter-treated arteries to be 25.42 ± 9.74 ng/mg at 1 h in the ex vivo system. Similar results were measured in vivo, as arterial paclitaxel concentrations were measured at 59.23 ± 41.27 ng/mg for the drug-coated balloon-treated arteries and 23.43 ± 20.23 ng/mg for the perfusion catheter-treated arteries. Overall, no significant differences were observed between paclitaxel measurements of arteries treated ex vivo vs. in vivo.Conclusion: This system represents the first validated ex vivo pulsatile system to determine pharmacokinetics in a native blood vessel. This work provides proof-of-concept of a quick, inexpensive, preclinical tool to study acute drug tissue concentration kinetics of drug-releasing interventional vascular devices.
- Open Access
- 28 November 2020
- Published by MDPI AG in Pharmaceuticals
- Vol. 13 (12) , 434
Pre-Clinical Investigation of Liquid Paclitaxel for Local Drug Delivery: A Pilot Study
The purpose of this pilot study was to investigate the feasibility of a perfusion catheter to deliver liquid paclitaxel into arterial segments. A clinically relevant rabbit ilio-femoral injury model was utilized to determine the impact of liquid paclitaxel delivered locally into the vessel wall using a perfusion catheter at 1 h to 14 days. Treatment by two clinically available forms of liquid paclitaxel, a solvent-based (sb) versus an albumin-bound (nab), along with a control (uncoated balloons), were investigated. Pharmacokinetic results demonstrated an increase in the retention of the sb-paclitaxel versus the nab-paclitaxel at 1 h; however, no other differences were observed at days one, three, and seven. Histological findings at 14 days showed significantly less neointimal area in the sb-paclitaxel treated arteries as compared with the nab-paclitaxel and the uncoated balloon-treated arteries. Additionally, percent area stenosis was significantly less in the sb-paclitaxel group. These results support the concept of local liquid delivery of paclitaxel into the arterial segments.
- 28 November 2020
- Published by MDPI AG in Pharmaceuticals
- Vol. 13 (12) , 434
Open AccessPre-Clinical Investigation of Liquid Paclitaxel for Local Drug Delivery: A Pilot Study
The purpose of this pilot study was to investigate the feasibility of a perfusion catheter to deliver liquid paclitaxel into arterial segments. A clinically relevant rabbit ilio-femoral injury model was utilized to determine the impact of liquid paclitaxel delivered locally into the vessel wall using a perfusion catheter at 1 h to 14 days. Treatment by two clinically available forms of liquid paclitaxel, a solvent-based (sb) versus an albumin-bound (nab), along with a control (uncoated balloons), were investigated. Pharmacokinetic results demonstrated an increase in the retention of the sb-paclitaxel versus the nab-paclitaxel at 1 h; however, no other differences were observed at days one, three, and seven. Histological findings at 14 days showed significantly less neointimal area in the sb-paclitaxel treated arteries as compared with the nab-paclitaxel and the uncoated balloon-treated arteries. Additionally, percent area stenosis was significantly less in the sb-paclitaxel group. These results support the concept of local liquid delivery of paclitaxel into the arterial segments.