Anna Isabella Pisani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anna Isabella Pisani has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Agnese Tamanti
Department of Neuroscience, Biomedicine and Movement Sciences, University of Verona, Verona, Italy
2 shared publications - Francesca Benedetta Pizzini
Department of Engineering for Innovation Medicine, University of Verona, Verona, Italy
2 shared publications - Francesco Crescenzo
Multiple Sclerosis Centre - Neurology Unit, “Mater Salutis” Hospital, Azienda ULSS 9 Scaligera , Verona
2 shared publications - Marco Castellaro
Department of Information Engineering, University of Padova, Padova, Italy
2 shared publications - Massimiliano Calabrese
Department of Neuroscience, Biomedicine and Movement Sciences, University of Verona, Italy
2 shared publications - Alessandro Brillo
Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, 37134 Verona, Italy
1 shared publication
Latest Publications
- Open Access
- 12 April 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (4) , 686
The Prognostic Value of White-Matter Selective Double Inversion Recovery MRI Sequence in Multiple Sclerosis: An Exploratory Study
Using a white-matter selective double inversion recovery sequence (WM-DIR) that suppresses both grey matter (GM) and cerebrospinal fluid (CSF) signals, some white matter (WM) lesions appear surrounded by a dark rim. These dark rim lesions (DRLs) seem to be specific for multiple sclerosis (MS). They could be of great usefulness in clinical practice, proving to increase the MRI diagnostic criteria specificity. The aims of this study are the identification of DRLs on 1.5 T MRI, the exploration of the relationship between DRLs and disease course, the characterization of DRLs with respect to perilesional normal-appearing WM using magnetization transfer imaging, and the investigation of possible differences in the underlying tissue properties by assessing WM-DIR images obtained at 3.0 T MRI. DRLs are frequent in primary progressive MS (PPMS) patients. Amongst relapsing-remitting MS (RRMS) patients, DRLs are associated with a high risk of the disease worsening and secondary progressive MS (SPMS) conversion after 15 years. The mean magnetization transfer ratio (MTR) of DRLs is significantly different from the lesion without the dark rim, suggesting that DRLs correspond to more destructive lesions.
- 12 April 2021
- Published by MDPI AG in Diagnostics
- Vol. 11 (4) , 686
Open AccessThe Prognostic Value of White-Matter Selective Double Inversion Recovery MRI Sequence in Multiple Sclerosis: An Exploratory Study
Using a white-matter selective double inversion recovery sequence (WM-DIR) that suppresses both grey matter (GM) and cerebrospinal fluid (CSF) signals, some white matter (WM) lesions appear surrounded by a dark rim. These dark rim lesions (DRLs) seem to be specific for multiple sclerosis (MS). They could be of great usefulness in clinical practice, proving to increase the MRI diagnostic criteria specificity. The aims of this study are the identification of DRLs on 1.5 T MRI, the exploration of the relationship between DRLs and disease course, the characterization of DRLs with respect to perilesional normal-appearing WM using magnetization transfer imaging, and the investigation of possible differences in the underlying tissue properties by assessing WM-DIR images obtained at 3.0 T MRI. DRLs are frequent in primary progressive MS (PPMS) patients. Amongst relapsing-remitting MS (RRMS) patients, DRLs are associated with a high risk of the disease worsening and secondary progressive MS (SPMS) conversion after 15 years. The mean magnetization transfer ratio (MTR) of DRLs is significantly different from the lesion without the dark rim, suggesting that DRLs correspond to more destructive lesions.
- Open Access
- 29 November 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (12) , 1025
The Use of the Central Vein Sign in the Diagnosis of Multiple Sclerosis: A Systematic Review and Meta-analysis
Background: The central vein sign (CVS) is a radiological feature proposed as a multiple sclerosis (MS) imaging biomarker able to accurately differentiate MS from other white matter diseases of the central nervous system. In this work, we evaluated the pooled proportion of the CVS in brain MS lesions and to estimate the diagnostic performance of CVS to perform a diagnosis of MS and propose an optimal cut-off value. Methods: A systematic search was performed on publicly available databases (PUBMED/MEDLINE and Web of Science) up to 24 August 2020. Analysis of the proportion of white matter MS lesions with a central vein was performed using bivariate random-effect models. A meta-regression analysis was performed and the impact of using particular sequences (such as 3D echo-planar imaging) and post-processing techniques (such as FLAIR*) was investigated. Pooled sensibility and specificity were estimated using bivariate models and meta-regression was performed to address heterogeneity. Inclusion and publication bias were assessed using asymmetry tests and a funnel plot. A hierarchical summary receiver operating curve (HSROC) was used to estimate the summary accuracy in diagnostic performance. The Youden index was employed to estimate the optimal cut-off value using individual patient data. Results: The pooled proportion of lesions showing a CVS in the MS population was 73%. The use of the CVS showed a remarkable diagnostic performance in MS cases, providing a pooled specificity of 92% and a sensitivity of 95%. The optimal cut-off value obtained from the individual patient data pooled together was 40% with excellent accuracy calculated by the area under the ROC (0.946). The 3D-EPI sequences showed both a higher pooled proportion compared to other sequences and explained heterogeneity in the meta-regression analysis of diagnostic performances. The 1.5 Tesla (T) scanners showed a lower (58%) proportion of MS lesions with a CVS compared to both 3T (74%) and 7T (82%). Conclusions: The meta-analysis we have performed shows that the use of the CVS in differentiating MS from other mimicking diseases is encouraged; moreover, the use of dedicated sequences such as 3D-EPI and the high MRI field is beneficial.
- 29 November 2020
- Published by MDPI AG in Diagnostics
- Vol. 10 (12) , 1025
Open AccessThe Use of the Central Vein Sign in the Diagnosis of Multiple Sclerosis: A Systematic Review and Meta-analysis
Background: The central vein sign (CVS) is a radiological feature proposed as a multiple sclerosis (MS) imaging biomarker able to accurately differentiate MS from other white matter diseases of the central nervous system. In this work, we evaluated the pooled proportion of the CVS in brain MS lesions and to estimate the diagnostic performance of CVS to perform a diagnosis of MS and propose an optimal cut-off value. Methods: A systematic search was performed on publicly available databases (PUBMED/MEDLINE and Web of Science) up to 24 August 2020. Analysis of the proportion of white matter MS lesions with a central vein was performed using bivariate random-effect models. A meta-regression analysis was performed and the impact of using particular sequences (such as 3D echo-planar imaging) and post-processing techniques (such as FLAIR*) was investigated. Pooled sensibility and specificity were estimated using bivariate models and meta-regression was performed to address heterogeneity. Inclusion and publication bias were assessed using asymmetry tests and a funnel plot. A hierarchical summary receiver operating curve (HSROC) was used to estimate the summary accuracy in diagnostic performance. The Youden index was employed to estimate the optimal cut-off value using individual patient data. Results: The pooled proportion of lesions showing a CVS in the MS population was 73%. The use of the CVS showed a remarkable diagnostic performance in MS cases, providing a pooled specificity of 92% and a sensitivity of 95%. The optimal cut-off value obtained from the individual patient data pooled together was 40% with excellent accuracy calculated by the area under the ROC (0.946). The 3D-EPI sequences showed both a higher pooled proportion compared to other sequences and explained heterogeneity in the meta-regression analysis of diagnostic performances. The 1.5 Tesla (T) scanners showed a lower (58%) proportion of MS lesions with a CVS compared to both 3T (74%) and 7T (82%). Conclusions: The meta-analysis we have performed shows that the use of the CVS in differentiating MS from other mimicking diseases is encouraged; moreover, the use of dedicated sequences such as 3D-EPI and the high MRI field is beneficial.